4
Quick Start Installation Manual EVAstream V21.2
Piezo Print | Settings
Slave mode: external master (EVO) control
Rotary = dmx adress 1-511
PPM output 1-2 to EVAstream motor control
Piezo 1 + 3 is pauze
Piezo 1 = dmx value +
Piezo 3 = dmx value -
Piezo 2 = on/off funtion or place a bridge over sw/sw
Master mode: piezo control
DMX in/out goes to EVAstream / UWL (underwater lighting) DMX input
Piezo/switch 4 = stop (reset) outside pool
Rotary (dmx) address 518 = 1 x piezo (1) control in 10% steps + (0, 30, 40, 50, 60, 70, 80, 90, 100)
Rotary (dmx) address 601 = 2 x piezo (1+3) piezo 1 = speed +, piezo 3 = speed -, piezo 1+3 = on/standby. In standby piezo 3 = off
Rotary (dmx) address 901 = 3 x piezo (1+2+3) piezo 1 = speed +, piezo 2 = on/standby, piezo 3 = speed -. In standby piezo 3 = off
Rotary (dmx) address 931 = 3 x piezo (1+2+3). Step 1 = select user (piezo 1 or 2 or 3). Step 2 = select training (piezo 1 or 2 or 3 -->
make selection within 5 seconds otherwise step 2 is skipped, automatic proceeding to step 3)
* In training mode (step 2) piezo 1 = speed +, piezo 2 = standby, piezo 3 = speed -. In standy piezo 3 = off
* In stap 3 (stap 2 skipped) piezo 1 = speed +, piezo 2 = standby, piezo 3 = speed -. In standby piezo 3 = off
When using rotary (dmx) address 901/931, connect underwater lighting (UWL) to DMX in/out. Control UWL, see below:
UWL control: piezo 1+3 = switch color, piezo 1+2 = light intensity -, piezo 2+3 = light intensity +
DMX start address (UWL and EVAstream) in master mode: UWL= dmx channel 1, EVAstream= dmx channel 5