Brief Introduction
3PA5015R represents today’s new technology for lead-acid type battery charging.
3PA5015R programmed four auto stages ( Ud-I-Uo-Up) charging process, It is
designed for all kinds of 12V 2-90Ah lead-acid battery, such as SLA, AGM and Gel
battery. Stage “Ud” desulfurating the battery through 20V pulse, when the battery
recovered, stage ‘I’ will give bulk current charging( 0.8A or 3.3A, defined by user, for
2-8Ah 0.8A is prefer, 12-90Ah should select 3.3A). Then “Uo” stage is followed, the
output voltage is fixed on 14.4V (14.7V is for low temperature, <5℃); When the
current declined to 0.4A; stage “Up” will turn on duty. At this stage, the battery is
charged completely and the charger gives some pulse to maintenance the battery.
Specification
Input Voltage 100-249VAC, 50-60Hz
Input Current 1.1A
Back current drain 1) 1.3mA
Charge voltage Rating 12V, Bulk 14.4V/14.7V (14.7V for low temperature)
Ripple 2) Voltage-ripple 50mV rms, Current-ripple 0.13A
Charge current 0.8A(2-8Ah, for motocycle) 3 3A (8-90Ah,for Car batt)
OperateTemperature -20℃-50℃
Cooling Natural convection. Do not cover the charger.
Charge principle Auto 4 stages: Ud-I-Uo-Up
Battery type All types of 12V lead-acid batteries. (SLA,GEL,AGM…..)
Battery capacity 2-90Ah
Size 120*67*41 (L*W*H)
Enclosure Waterproof splash/ rain-proof
Weight 275g
zThe back current drain (reverse current) is the current that the charger uses form
the battery when the wall plug is not connected.
zThe ripple wave describes how many disturbances are exhibited by current and
voltage. A rippled voltage can cause damage to other equipment connected to
the battery.
Display Panel
How to use:
1. Connect positive charger clip (red) to positive battery terminal, the black clip to
negative. (You can use other appendix wires to connectbattery).
2. Connect the AC cord to the socket, the red alarm indication light will indicate a
battery which is connected to reverse polarity.
3. Pressing the “MODE-button” and stepping forward one press at a time until the
required mode is reached, the button is then release.
4. When the “charging finished” led lights up, the battery is fully charged. When
disconnecting charger, disconnect in reverse sequence from connecting
procedure.
The table show the duration of the Bulk step up to about 80% state of charger.
Battery Type (Ah) MODE Timer (hours)
2 2-3
8 8-10
14 3-4
50 12-14
90
23-26
Mode
select