Evident Vanta GX User manual

10-031736-01EN — Rev. 2
December 2022
Vanta GX
X-Ray Fluorescence Analyzer
User’s Manual
This instruction manual contains essential information on how to use this Evident product safely and effectively.
Before using this product, thoroughly review this instruction manual. Use the product as instructed.
Keep this instruction manual in a safe, accessible location.

EVIDENT SCIENTIFIC, INC.
48 Woerd Avenue, Waltham, MA 02453, USA
Copyright © 2022 by Evident. All rights reserved. No part of this publication may
be reproduced, translated, or distributed without the express written permission of
Evident.
This document was prepared with particular attention to usage to ensure the
accuracy of the information contained therein, and corresponds to the version of
the product manufactured prior to the date appearing on the title page. There
could, however, be some differences between the manual and the product if the
product was modified thereafter.
The information contained in this document is subject to change without notice.
Part number: 10-031736-01EN
Rev. 2
December 2022
Printed in the United States of America
The microSD Logo is a trademark of SD-3C, LLC.
All brands are trademarks or registered trademarks of their respective owners and
third party entities.

10-031736-01EN, Rev. 2, December 2022
Table of Contents 3
Table of Contents
List of Abbreviations ......................................................................................... 7
Important Information — Please Read Before Use ..................................... 9
Intended Use .......................................................................................................................... 9
Instruction Manual ................................................................................................................ 9
Instrument Compatibility ................................................................................................... 10
Repair and Modification ..................................................................................................... 10
Safety Symbols ..................................................................................................................... 11
Safety Signal Words ............................................................................................................ 12
Note Signal Words .............................................................................................................. 12
Safety ..................................................................................................................................... 13
Warnings ............................................................................................................................... 13
Equipment Disposal ............................................................................................................ 15
Electrostatic Discharge Precautions .................................................................................. 16
CE (European Community) ............................................................................................... 16
UKCA (United Kingdom) .................................................................................................. 17
RCM (Australia) ................................................................................................................... 17
WEEE Directive .................................................................................................................... 17
China RoHS .......................................................................................................................... 17
Korea Communications Commission (KCC) ................................................................... 19
KC (South Korea Community) .......................................................................................... 19
EMC Directive Compliance ................................................................................................ 19
FCC (USA) Compliance ...................................................................................................... 19
ICES-001 (Canada) Compliance ........................................................................................ 20
Code de la santé publique (France) ................................................................................... 21
Packing and Return Shipping ............................................................................................ 21
Warranty Information ......................................................................................................... 21
Technical Support ................................................................................................................ 22
Introduction ...................................................................................................... 23

10-031736-01EN, Rev. 2, December 2022
Table of Contents4
Enclosure ............................................................................................................................... 23
Analysis Hardware .............................................................................................................. 24
Computer .............................................................................................................................. 24
Software ................................................................................................................................. 25
1. Analyzer Overview .................................................................................... 27
1.1 Packing List ................................................................................................................ 27
1.2 Standard Accessories ................................................................................................ 29
1.3 Optional Transport Case .......................................................................................... 31
1.4 Physical Planning ...................................................................................................... 31
1.5 Power Supply ............................................................................................................ 34
1.6 Cable Connections .................................................................................................... 35
2. Safety Information ..................................................................................... 37
2.1 Grounding and Power Information ....................................................................... 37
2.2 Radiation Safety Information .................................................................................. 37
2.3 Radiation Safety Program ........................................................................................ 38
2.4 X-Ray Safety ............................................................................................................... 38
2.5 Safety Interlock Structure ........................................................................................ 39
2.6 General Precautions .................................................................................................. 39
2.7 Service Considerations ............................................................................................. 40
2.8 Electrical Precautions ............................................................................................... 40
2.8.1 AC Power Adapter ......................................................................................... 41
2.8.2 Cables and Cords ........................................................................................... 41
2.9 Indicators and Statuses ............................................................................................ 42
2.9.1 Power Button and Chamber Light ............................................................... 42
2.9.2 X-Ray Indicator ............................................................................................... 42
2.9.3 Information Bar .............................................................................................. 42
2.10 Physical Safety ........................................................................................................... 43
2.11 Safety Administration .............................................................................................. 44
2.11.1 Radiation Safety Training Recommendations ........................................... 44
2.11.2 Dosimeters ....................................................................................................... 46
2.11.3 Dosimeter Safety Program ............................................................................ 47
2.11.4 Dosimeter Suppliers ...................................................................................... 48
2.11.5 Radiation Safety FAQ .................................................................................... 49
2.11.6 Registration Requirements ........................................................................... 51
3. Operation ..................................................................................................... 53
3.1 Sample Analysis ........................................................................................................ 53
3.1.1 Starting Up the Analyzer .............................................................................. 53
3.1.2 Conducting a Test ........................................................................................... 54

10-031736-01EN, Rev. 2, December 2022
Table of Contents 5
3.2 Shutdown Procedures .............................................................................................. 56
3.2.1 Shutting Down Under Normal Conditions ................................................ 57
3.2.2 Shutting Down Under Emergency Conditions ......................................... 57
4. Maintenance ................................................................................................ 59
4.1 Touch-Screen Care .................................................................................................... 59
4.2 Replacing the Measurement Window ................................................................... 59
5. Vanta GX Radiation Profile ...................................................................... 61
Appendix: Specifications ................................................................................ 63
List of Figures ................................................................................................... 67
List of Tables ..................................................................................................... 69

10-031736-01EN, Rev. 2, December 2022
Table of Contents6

10-031736-01EN, Rev. 2, December 2022
List of Abbreviations 7
List of Abbreviations
AC alternating current
ALARA as low as reasonably achievable
DC direct current
EDXRF energy dispersive X-ray fluorescence
EFUP environment-friendly use period
LED light-emitting diode
mrem millirem
SDD silicon drift detector
Sv sievert

10-031736-01EN, Rev. 2, December 2022
List of Abbreviations8

10-031736-01EN, Rev. 2, December 2022
Important Information — Please Read Before Use 9
Important Information — Please Read Before Use
Intended Use
The Vanta GX analyzer is designed to perform identification and analysis of elements
(from Ti to U) in precious metals.
Do not use the Vanta GX for any purpose other than its intended use. It must never be
used to inspect or examine human or animal body parts.
Instruction Manual
This instruction manual contains essential information on how to use this Evident
product safely and effectively. Before using this product, thoroughly review this
instruction manual. Use the product as instructed.
Keep this instruction manual in a safe, accessible location.
If you have any questions or comments about any information in this manual, please
contact Evident.
WARNING

10-031736-01EN, Rev. 2, December 2022
Important Information — Please Read Before Use10
Some of the details of components illustrated in this manual may differ from the
components installed on your instrument. However, the operating principles remain
the same.
Instrument Compatibility
The Vanta GX analyzer is primarily a self-contained unit. However, it does have USB
ports that enable you to connect compatible peripherals. It also derives its required
DC input power from a standard accessory AC adapter.
Always use accessories and peripherals that meet Evident specifications. Using
incompatible accessories or peripherals could cause equipment malfunction and/or
damage, or human injury.
Repair and Modification
The Vanta GX analyzer does not contain any user-serviceable parts, apart from one
exception: the measurement window. If the measurement window is damaged, the
window assembly should be replaced as soon as possible. See “Maintenance” on
page 59 for the window-assembly removal and reinstallation instructions.
Opening of the instrument housings (lid, base, and control enclosure, including the
touch-screen display) by anyone other than an Evident-trained service person will
void the warranty.
IMPORTANT
CAUTION

10-031736-01EN, Rev. 2, December 2022
Important Information — Please Read Before Use 11
In order to prevent human injury and/or equipment damage, do not disassemble,
modify, or attempt to repair the instrument.
Safety Symbols
The following safety symbols might appear on the instrument and in the instruction
manual:
General warning symbol
This symbol is used to alert the user to potential hazards. All safety messages that
follow this symbol shall be obeyed to avoid possible harm or material damage.
Radiation warning symbol (International)
Radiation warning symbol (Canada)
Radiation warning symbol (China)
These symbols are used to alert the user to the presence of potentially harmful
ionizing radiation generated within the XRF or XRD analyzer. All safety messages
that follow this symbol shall be obeyed to avoid possible harm.
Shock hazard caution symbol
This symbol is used to alert the user to potential electric shock hazards. All safety
messages that follow this symbol shall be obeyed to avoid possible harm.
CAUTION

10-031736-01EN, Rev. 2, December 2022
Important Information — Please Read Before Use12
Safety Signal Words
The following safety signal words might appear in the documentation of the
instrument:
The WARNING signal word indicates a potentially hazardous situation. It calls
attention to a procedure, practice, or the like that if not correctly performed or
adhered to could result in death or serious personal injury. Do not proceed beyond a
WARNING signal word until the indicated conditions are fully understood and met.
The CAUTION signal word indicates a potentially hazardous situation. It calls
attention to a procedure, practice, or the like that if not correctly performed or
adhered to may result in minor or moderate personal injury, material damage,
particularly to the product, destruction of part or all of the product, or loss of data. Do
not proceed beyond a CAUTION signal word until the indicated conditions are fully
understood and met.
Note Signal Words
The following note signal words could appear in the documentation of the
instrument:
The IMPORTANT signal word calls attention to a note that provides information that
is important or essential to the completion of a task.
The NOTE signal word calls attention to an operating procedure, practice, or the like,
that requires special attention. A note also denotes related parenthetical information
that is useful, but not imperative.
WARNING
CAUTION
IMPORTANT
NOTE

10-031736-01EN, Rev. 2, December 2022
Important Information — Please Read Before Use 13
The TIP signal word calls attention to a type of note that helps you apply the
techniques and procedures described in the manual to your specific needs, or that
provides hints on how to effectively use the capabilities of the product.
Safety
Before turning on the instrument, verify that the correct safety precautions have been
taken (see the following warnings). In addition, note the external markings on the
instrument.
Warnings
General Warnings
• Carefully read the instructions contained in this instruction manual before
turning on the instrument.
• Keep this instruction manual in a safe place for further reference.
• Follow the installation and operation procedures.
• It is imperative to respect the safety warnings on the instrument and in this
instruction manual.
• If the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment could be impaired.
• Do not install substitute parts or perform any unauthorized modification to the
instrument.
• Service instructions, when applicable, are for trained service personnel. To avoid
the risk of electric shock, do not perform any work on the instrument unless
qualified to do so. For any problem or question regarding this instrument, contact
Evident or an authorized Evident representative (see “Technical Support” on
page 22).
• Do not allow metallic or foreign objects to enter the device through connectors or
any other openings. Otherwise, a malfunction or electric shock may result.
TIP
WARNING

10-031736-01EN, Rev. 2, December 2022
Important Information — Please Read Before Use14
Radiation Safety Warnings
• The Vanta GX analyzer is a closed-beam instrument with respect to ionizing
radiation. Therefore, when properly using the analyzer, the operator and near-by
associates will not encounter radiation levels greater than those allowed by local
regulations.
• Do not attempt to bypass or defeat the safety interlock system.
See “Safety Information” on page 37 for more information about safety.
Mechanical Safety Warnings
The Vanta GX analyzer is comprised of three major mechanical assemblies:
• A shielded lid with a bismuth-acrylic viewing window.
• A shielded main body with a test chamber, XRF measurement window, and
failsafe LED array.
• A control enclosure that includes:
— An I/O display with touch-screen panel
—Apowerswitch
— Navigation keys
—USBport
— A mechanical lid latch
The lid and main body are connected by integral hinges assisted by two dampening
closures. The control enclosure is permanently fixed to the front of the shielded body.
NOTE
WARNING

10-031736-01EN, Rev. 2, December 2022
Important Information — Please Read Before Use 15
When closing the analyzer in preparation for relocation, shipment, or storage, refer to
the following guidelines:
• Make sure that you do not pinch your finger(s).
• If you encounter resistance when closing the unit, do not force the assemblies
together.
• Secure the lid using the lid lock.
Electrical Warnings
• Before turning on the instrument, you must connect the standard IEC 3-conductor
power cord of the AC power adapter to a properly grounded AC socket of
appropriate voltage, as marked on the adapter.
• Never negate the protective action by using an extension cord (power cable)
without a protective conductor (grounding).
• If there is any possibility that the ground protection could be impaired, you must
make the instrument inoperative and secure it against any unintended operation.
• The instrument must be connected only to a power source corresponding to the
type indicated on the rating plate label.
• Do not operate the unit in the rain or near standing water.
If an unauthorized power supply cord is used to power the instrument, Evident
cannot guarantee the electrical safety of the equipment.
Equipment Disposal
Before disposing of the Vanta GX, check your local laws, rules, and regulations, and
follow them accordingly.
WARNING
CAUTION

10-031736-01EN, Rev. 2, December 2022
Important Information — Please Read Before Use16
California Battery Disposal
For California (USA) only:
The CR battery contains perchlorate material, and special handling may be required.
Refer to https://www.dtsc.ca.gov/hazardouswaste/perchlorate for details.
Electrostatic Discharge Precautions
The Vanta GX analyzer must never be disassembled by an end user.
If a nonqualified service technician or end user disassembles the instrument:
• The instrument’s warranty will be void.
• The instrument’s internal components could be damaged.
CE (European Community)
This device complies with the requirements of directive 2014/30/EU
concerning electromagnetic compatibility, directive 2014/35/EU
concerning low voltage, and directive 2015/863 which amends
2011/65/EU concerning restriction of hazardous substances (RoHS).
The CE marking is a declaration that this product conforms to all the
applicable directives of the European Community.
CAUTION

10-031736-01EN, Rev. 2, December 2022
Important Information — Please Read Before Use 17
UKCA (United Kingdom)
RCM (Australia)
WEEE Directive
China RoHS
China RoHS is the term used by industry generally to describe legislation
implemented by the Ministry of Information Industry (MII) in the People’s Republic
of China for the control of pollution by electronic information products (EIP).
This device complies with the requirements of the Electromagnetic
Compatibility Regulations 2016, the Electrical Equipment (Safety)
Regulations 2016, and the Restriction of the Use of Certain Hazardous
Substances in Electrical and Electronic Equipment Regulations 2012.
The UKCA marking indicates compliance with the above regulations.
The regulatory compliance mark (RCM) indicates that the product
complies with all applicable standards, and has been registered with
the Australian Communications and Media Authority (ACMA) for
placement on the Australian market.
In accordance with European Directive 2012/19/EU on Waste Electrical
and Electronic Equipment (WEEE), this symbol indicates that the
product must not be disposed of as unsorted municipal waste, but
should be collected separately. Refer to your local Evident distributor
for return and/or collection systems available in your country.

10-031736-01EN, Rev. 2, December 2022
Important Information — Please Read Before Use18
“中国 RoHS” 是一个工业术语,一般用于描述中华人民共和国信息工业部 (MII)针
对控制电子信息产品 (EIP)的污染所实行的法令。
The China RoHS mark indicates the product’s Environment-
Friendly Use Period (EFUP). The EFUP is defined as the number of
years for which listed controlled substances will not leak or
chemically deteriorate while in the product. The EFUP for the
Vanta GX has been determined to be 15 years.
Note: The Environment-Friendly Use Period (EFUP) is not meant
to be interpreted as the period assuring functionality and product
performance.
电气电子产品
有害物质
限制使用标识
中国 RoHS 标识是根据 “电器电子产品有害物质限制使用管理办
法”以及 “电子电气产品有害物质限制使用标识要求 ”的规定,适
用于在中国销售的电气电子产品上的电气电子产品有害物质限制使
用标识。
注意:电气电子产品有害物质限制使用标识内的数字为在正常的使
用条件下有害物质不会泄漏的年限,不是保证产品功能性的年限。
产品中有害物质的名称及含量
有害物质
部件名称 铅及其
化合物
汞及其
化合物
镉及其
化合物
六价铬及
其化合物
多溴联苯 多溴
二苯醚
(Pb) (Hg) (Cd) (Cr( Ⅵ)) (PBB) (PBDE)
机构部件 ×○○○○○
主体 光学部件 ×○○○○○
电气部件 ×○○○○○
附件 ×○○○○○
本表格依据 SJ/T 11364 的规定编制。
○:表示该有害物质在该部件所有均质材料中的含量均在 GB/T26572 规定的限量要求以下。
×:表示该有害物质至少在该部件的某一均质材料中的含量超出 GB/T26572 规定的限量要求。

10-031736-01EN, Rev. 2, December 2022
Important Information — Please Read Before Use 19
Korea Communications Commission (KCC)
KC (South Korea Community)
This device complies with the requirements of KS C 9610-6-2 and KS C 9610-6-4
concerning electromagnetic compatibility. The KCC marking indicates compliance
with the above standards. The MSIP registration number for the Vanta GX is the
following: R-R-OYN-VANTA-GX.
EMC Directive Compliance
This equipment generates and uses radio-frequency energy and, if not installed and
used properly (that is, in strict accordance with the manufacturer’s instructions), may
cause interference. The Vanta GX has been tested and found to comply with the limits
for an industrial device in accordance with the specifications of the EMC directive.
FCC (USA) Compliance
This product has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the product is operated in a
commercial environment. This product generates, uses, and can radiate radio
frequency energy, and if not installed and used in accordance with the instruction
manual, might cause harmful interference to radio communications. Operation of this
product in a residential area may cause harmful interference, in which case you will
be required to correct the interference at your own expense.
이 기기는 업무용 환경에서 사용할 목적으로 적합성평가를 받은 기
기로서 가정용 환경에서 사용하는 경우 전파간섭의 우려가 있습니
다.
NOTE

10-031736-01EN, Rev. 2, December 2022
Important Information — Please Read Before Use20
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the product.
FCC Supplier’s Declaration of Conformity
Hereby declares that the product,
Product name: Vanta GX
Model: VGP/VGS
Conforms to the following specifications:
FCC Part 15, Subpart B, Section 15.107 and Section 15.109.
Supplementary information:
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference
that may cause undesired operation.
Responsible party name:
EVIDENT SCIENTIFIC, INC.
Address:
48 Woerd Avenue, Waltham, MA 02453, USA
Phone number:
+1 781-419-3900
ICES-001 (Canada) Compliance
This Class A digital apparatus complies with Canadian ICES-001.
Cet appareil numérique de la classe A est conforme à la norme NMB-001 du Canada.
IMPORTANT
Table of contents