Evolution Aqua Varipump 10000 User manual

INSTRUCTION MANUAL
Evolution Aqua Ltd. - Evolution House - Kellet Close - Wigan - Lancashire - United Kingdom - WN5 0LP
UK
English
VARIPUMP12209221MAN
PLEASE READ ALL OF THE INSTRUCTION MANUAL BEFORE
ATTEMPTING TO INSTALL OR OPERATE THE VARIPUMP.
In the unlikely event the pump is supplied with a plug, this can be cut off
and removed in the UK, as the mains supply cable should be wired into a
safe, compliant, outdoor electrical system, with an RCD cut-off.
Cutting the plug off will not invalidate the warranty.

WARNING: PLEASE READ THE FOLLOWING
SAFETY INFORMATION FIRST.
IMPORTANT SAFETY INFORMATION
- Please read the instruction manual carefully.
- The electrical installation is to be done by a qualified electrician,
in accordance with applicable electrical codes.
- WARNING: Always shut off electrical power before installation and /
or servicing this pump.
- A residual current device (RCD), also known as the residual current
circuit breaker (RCCB), with a tripping current not exceeding 30mA
must be installed in the supply circuit.
- A means of disconnection from the supply having a contact separation
of at least 3mm in all poles must be incorporated in the wiring.
- Check the pumps name plate for the following:
Voltage, Amp draw and Cycle.
- Do not use this power cord if there is any visible damage.
- Do not use this power cord in water or if the motor or electrical
receptacle is in contact with any standing water.
- This power cord should only be plugged into a properly installed RCD.
- Always test cycle a RCD to determine its condition before use.
- Improper installation can create electrical hazards which could result
in property damage, serious injury or death. Improper installation will
void the warranty.
- Do not submerse the controller in water.
- The pump should be operated when permissible temperature is
between 0˚C and 35˚C. The pump should never be operated
outside of these temperatures or damage may occur.
- Do not operate he pump without water.
- Young children must always be supervised near ponds.
Disposal Of Your Old Product
Your product is designed and manufactured with high quality material and components,
which can be recycled and reused. When this crossed-out wheeled bin symbol is attached
to a product, it means the product is covered by the European Directive 2002/96/EC.
Please contact your local authority about correct disposal for electrical and electronic
equipment. Our WEEE Registration Number is WEE/FE1471RR.
Please act according to your local rules and do not dispose of your old products with
your normal household waste. The correct disposal of your old product will help prevent
potential negative consequences for the environment and human health.

3
INTRODUCING THE EVOLUTION AQUA VARIPUMP
Congratulations on purchasing an Evolution Aqua Varipump.
Varipump by Evolution Aqua is a fully controllable pond pump, suitable for large ponds.
Output and energy consumption can be controlled at the push of a button allowing you to
set the flow rate to your needs whilst monitoring the operating wattage. The motor is quiet
and reliable, delivering consistent performance, while being very economical to run.
Available in three sizes, 10,000lph, 20,000lph and 30,000lph, Varipump is powerful
enough to run the largest of ponds and filters, and in the most demanding of situations.
It can be used as a submersible pond pump or it can be installed out of the pond,
drawing water from the pond and through your filtration system.

4
Varipump 10,000 Connectors & Washers
WHAT’S IN THE BOX?
Varipump 10,000
INSTALLATION ADVICE: Instead of using the fittings supplied we recommend purchasing
two 1½” Single Unions (Threaded Female To Plain Female), (EA Code: K82-76-55),
to connect the inlet and outlet of the Varipump 10,000 to 1½” Pressure Pipe.
Fittings and pressure pipe are available from Evolution Aqua stockists.
Varipump 10,000
(Strainer Basket & Base Plate)
Inlet & Outlet Connectors
To 40mm Pipe
Hosetail For
Inlet / Outlet
1 x Washer For Hosetail
2 x O-Rings For Connectors
45mm OD
33mm ID
x 3mm
36.5mm OD
x 2.65mm
36.5mm OD
x 2.65mm
Control
Box

5
Varipump 20,000 / 30,000 Connectors & Washers
WHAT’S IN THE BOX?
Varipump 20,000 / 30,000
Varipump 20,000 / 30,000
(Strainer Basket & Base Plate)
Inlet & Outlet Connectors
To 50mm Pipe
Hosetail For
Inlet / Outlet
3 x Washers For
Hosetail And Connectors
Control
Box
INSTALLATION ADVICE: Instead of using the fittings supplied we recommend purchasing
two 2” Single Unions (Threaded Female To Plain Female), (EA Code: K82-76-66),
to connect the inlet and outlet of the Varipump 20,000 / 30,000 to 2” Pressure Pipe.
Fittings and pressure pipe are available from Evolution Aqua stockists.
56mm OD
45mm ID
x 3mm

6
SPECIFICATIONS
INLET OUTLET
MAX.
FLOW
(LITRES
PER HOUR)
MAX.
FLOW
(GALLONS
PER HOUR)
MAX.
FLOW
(US GALLONS
PER HOUR)
MAX.
HEAD DIMENSIONS
Varipump
10000 1½” 1½” 10,000 2,200 2,642 3.1m
267mm (L)
122mm (W)
162mm (H)
Varipump
20000 2” 2” 20,000 4,400 5,283 5.5m
319mm (L)
142mm (W)
181mm (H)
Varipump
30000 2” 2” 30,000 6,600 7,925 5.5m
370mm (L)
155mm (W)
205mm (H)
PUMP CURVES

7
CONNECTION TO THE ELECTRICITY SUPPLY
Electrical installations must be done by a qualified electrician.
In the unlikely event the pump is supplied with a plug,
this can be cut off and removed, as it should be wired into a safe,
compliant, outdoor electrical system, with an RCD cut-off.
Cutting the plug off will not invalidate the warranty.
The power supply must meet the specifications on the product.
The cores in the supply cable are coloured in accordance with the following code:
Brown = Live. Blue = Neutral. Earth = Green/Yellow
(WHERE FITTED).
DO NOT use the supply cable to lift the pump as this may
cause damage.
WARNING - A Residual Current Device (RCD), also known as the Residual Current Circuit
Breaker (RCCB), with a tripping current not exceeding 30mA must be installed in the
supply circuit. A means of disconnection from the supply having a contact separation of at
least 3mm in all poles must be incorporated in the wiring.
Caution: Use in the area of the garden pond only if the installation complies with the
relevant wiring regulations. Please consult a qualified electrician.
Caution: Always disconnect all pond appliances from the mains supply before putting your
hands into the water.
All electrical installations and wiring must be adequately protected to prevent
any damage.
2 metres of electrical cable is supplied to connect the mains power to the control box.
10 metres of cable is provided to connect the control box to the pump.
This unit must be connected to permanent wiring. A switch with 3mm contact separation
must be provided in the fixed wiring to provide disconnection from the electricity supply.
Install this product where it will not come into contact with water or other liquids. Install
this product where it will be weather protected. Electrically ground this product. Failure to
follow these instructions can result in death, fire or electrical shock.
The control box is rated IPX4. It is therefore weather / rain-proof and can be kept outside,
it MUST NOT be submerged in water.
The pump is rated IPX8 and can be fully submerged in water.

8
VARIPUMP 10,000 TO 1½” PRESSURE PIPE
We recommend connecting Varipump 10,000 to 1½” Pressure Pipe.
To do this we recommend screwing a 1½” Single Union, Threaded Female To Plain Female
(EA Code: K82-76-55) onto the inlet and outlet of the Varipump. This also enables easy
access to the pump for maintenance when on a gravity fed set-up.
You can then glue 1½” Pressure Pipe (U15-050) directly into these connectors,
using Solvent Weld Adhesive (EA Code: S79-0-500).
VARIPUMP 20,000 AND 30,000 MODELS TO 2” PRESSURE PIPE
We recommend connecting Varipump 20,000 and 30,000 pumps to 2” Pressure Pipe.
To do this we recommend screwing a 2” Single Union, Threaded Female To Plain Female
(EA Code: K82-76-66) onto the inlet and outlet of the Varipump. This also enables easy
access to the pump for maintenance when on a gravity fed set-up.
You can then glue 2” Pressure Pipe (U15-063) directly into these connectors,
using Solvent Weld Adhesive (EA Code: S79-0-500).
If you want to connect the Varipump 20,000 or 30,000 to 1½” Pressure Pipe, follow steps
above and add a 2” to 1½” Plain Reducing Bush (EA Code: R81-063).
CONNECTING THE VARIPUMP TO PRESSURE PIPE
INLET
OUTLET
Pressure Pipe
Pressure Pipe
Single Union
Threaded Female
To Plain Female
Single Union Threaded
Female To Plain Female

9
CONNECTING VARIPUMP 10,000
TO FLEXIBLE HOSE
The stepped hosetail supplied allows connections
to 38mm (1½”), 32mm, 26mm Flexible Hose.
When fitting the hosetail, ensure the flat washer
provided is seated correctly inside the thread
before screwing to the outlet of the pump.
We advise using the largest connection therefore
the smaller sections of the hosetail must be cut off
to ensure sufficient water flow. Once the hosetails
have been trimmed, secure the flexible hose to
using a stainless steel hose clip (not provided).
CONNECTING VARIPUMP 20,000 & 30,000
TO FLEXIBLE HOSE
The stepped hosetail supplied allows connections
to 50mm (2”), 40mm, 32mm Flexible Hose.
When fitting the hosetail, ensure the flat washer
provided is seated correctly inside the thread
before screwing to the outlet of the pump.
We advise using the largest connection therefore
the smaller sections of the hosetail must be cut off
to ensure sufficient water flow. Once the hosetails
have been trimmed, secure the flexible hose to
using a stainless steel hose clip (not provided).
CONNECTING THE VARIPUMP TO FLEXIBLE HOSE

10
POND
Water Level Return to pond
UV
Alternative return via waterfall / blade
Alternative
return
Varipump
4” Pipe
Gravity fed filter installation example shown
INSTALLATION ADVICE - GRAVITY FED SET-UP
1. The pump suction line should be not smaller than 1½” (40mm imperial)
or 50mm true metric.
2. We recommend using Single Unions, Threaded Female To Plain Female,
to connect to Pressure Pipe (see page 8 for advice).
3. The suction line is to have as few bends or elbows as possible. There must not
be an air trap on the suction line.
4. Tighten the pump fittings only as much as is required to ensure a tight connection.
Excessive torque is unnecessary and may cause damage to the pump.
5. All wiring (electrical) work must be carried out by a qualified electrician and must
be installed in accordance to the local codes.
6. The motor must be earthed.
7. The weight of the plumbing and fittings is to be independently supported and not
carried by the pump.
8. The pump is not self-priming. Therefore, if the water level is below the pump,
a non-return valve must be installed below water level. The pump and inlet line
must be primed prior to start up. For non-flooded installations a check valve
(non-return valve) is recommended.
9. The controller must not be submerged in water.
10. Do not operate the pump without water.

11
POND
UV
Varipump
1½” or 2” Pipe
4” Pipe
Return to pond
Pump fed filter installation example shown
INSTALLATION ADVICE - PUMP FED SET-UP
Varipump can be submersed in water, as part of a pump fed system. When installing
on pump fed systems we recommend using the hosetails provided to connect up to
flexible hose (not supplied).
1. Flexible hose (not supplied) should be the widest possible diameter.
2. Extra steps on hosetails should always be sawn off and removed.
3. A hoseclip (not supplied) must always be used to hold the hose in place on
the hosetail.
4. Ensure sealing rings are fitted properly.
5. If using pressure pipe, use the appropriate Single Unions, Threaded Female To
Plain Female as shown on page 8.
6. All wiring (electrical) work must be carried out by qualified electricians and must be
installed in accordance to the local codes.
7. The motor must be earthed.
8. The controller must not be submerged in water.
9. Do not operate the pump without water.

12
Before installing the Varipump, it is important to consider its location in relation to the mains
power supply and control box. There is 10 metres of cable from the control box to the pump,
and there is 2 metres of cable to connect the control box to the mains supply.
The control box is rated IPX4, therefore it is weather / rain-proof and can be kept outside,
but it MUST NOT be submerged in water.
We recommend securing the control box to a wall in a location you can easily access at all
times. Use the four slots around the edge of the control box to help mount the box, using
appropriately sized screws and wall fixing plugs.
In the unlikely event the pump is supplied with a plug, this can be cut off and removed, as
the mains supply cable should be wired into a safe, compliant, outdoor electrical system,
with an RCD cut-off. Cutting the plug off will not invalidate the warranty.
The cable from the pump has a weatherproof 4 pin connector that should be inserted into
the control box connector. Then slide the sleeve over the connectors and tighten up.
SETTING UP THE VARIPUMP CONTROL BOX
MAINS
POWER
CABLE
MAINS
POWER
CABLE
PUMP
CABLE
PUSH-FIT SCREW
PUMP
CABLE

13
OPERATING THE VARIPUMP
GENERAL OPERATING ADVICE
Once connected, use the button to turn the Varipump on or off. The display shows the
operating wattage that the Varipump is running at. When you press the or buttons to
increase or decrease the flow rate, a number between 0 and 100 appears on the screen.
This indicates the percentage of power that the pump is running at. ZERO means no flow
and 100 means maximum flow (100%). After a few seconds the display reverts back to
display the current wattage.
It may be possible that the operating wattage displayed fluctuates at different times of
the day, this is perfectly normal.
If the display shows letters and numbers, this is a fault code, see TROUBLESHOOTING.
Do not operate the Varipump without water.
Do not use when temperatures are less then 0°C and 35°C. If there is a chance that the
water will freeze over and restrict the flow, then you should take it out of the pond and
dry it out. Store it over Winter in a dry place, then reconnect the pump again in Spring.
The Varipump is not self-priming, therefore, if the water level is below the pump,
a non-return valve must be installed below the water level. The pump and inlet line
must be primed prior to start up. For non-flooded installations a check valve (non-return
valve) is recommended.
Percentage of power displays briefly when
pressing or
Wattage displays when Varipump is on.
Press power button to Varipump off.

14
CLEANING THE VARIPUMP - SCAN QR CODE FOR CLEANING VIDEO
ALWAYS DISCONNECT THE PUMP FROM THE MAINS POWER BEFORE MAINTENANCE.
It is good practice to inspect the Varipump regularly and to clean it
once or twice per year. Scan the QR code to watch a cleaning video.
Always turn off the power before removing the pump.
On gravity fed installs, unscrew the collar on the unions to remove the
inlet and outlet pipework.
On pump fed installs, use the handle to pull the pump out of the pond,
do not pull on the cable.
Step 1: Disconnect the pump from the
pipework or flexi-hose connections.
Step 2: Remove the pump strainer basket
(if applicable).
Step 3: Remove the plate from underneath
the pump.
Step 4: Unscrew all four screws around
the blue plastic impeller housing.
Step 5: Unscrew the screw that is
attached to the handle.
Step 6: Remove the handle.

15
CLEANING THE VARIPUMP
Step 9: Wipe clean to remove any excess
dirt.
Step 10: Re-fit the impeller housing.
This can be positioned at multiple angles.
Step 11: Re-fit the handle and tighten up
the screw.
Step 12: Re-fit all four screws around the
impeller housing and tighten up.
Step 13: Re-fit the base plate. Step 14: Clip on the strainer basket
(if applicable).
Step 7: Carefully pull away the impeller
housing.
Step 8: Use a brush to clean inside and
around the impeller.
RE-CONNECT THE INLET / OUTLET PIPEWORK AND TURN THE POWER BACK ON

16
TROUBLESHOOTING - CONTROL BOX FAULT CODES
In the unlikely event of an issue developing
with the Varipump, a 3 digit fault code may be
displayed on the control box screen.
Use the table below to understand what these
codes mean.
If the controller displays digits but the pump is
not working - pull out the power cord and re-start.
Fault
Code Fault Resolution
E01 Pump is
out of water The pump is working without water.
E02 Over current Abnormal load over current protection.
Please pull out the power plug and re-plug again.
E03 Default phase Bad contact or loose connection in the motor.
E04
Issue with power
cable connecting
pump to the
control box
E05 Impeller stuck
Rotation clogging protection, if the pump still not working
after restart for three times, please re-plug the power.
Or clean the impeller (refer to manual)
E06 Over voltage Over voltage protection when the working voltage is
higher than the rated voltage.
E07 Under voltage Low voltage protection when the working voltage is
lower than the rated voltage.
Check the cable for signs
of visible damage. Or there
maybe a loose connection
inside the control box.
Disconnect the pump from
the mains, unscrew the
control box and check the
connections (see photos).
If connections are fitted
and the pump still does
not, the control box may
be faulty and needs
changing.

17
TROUBLESHOOTING
Symptom Problem Resolution
No Flow
Insufficient Prime Prime system with water and purge all air from suction
piping.
No Power
Wired incorrectly or an RCD has tripped.
Pump has been switched off at the controller.
Flow
Restriction
Ensure valves are open.
Ensure plumbing is clear, including suction strainers,
check valves, etc.
Verify non return valve orientation and direction of permitted
flow.
Clean out leaves or other debris from basket strainer (if
applicable).
Air leak Fix air leaks at fittings, connections, strainer basket etc.
This typically occurs on the intake side.
System
Incompatibility
Verify hydraulic compatibility: i.e. pump & pipe are sized
for the system.
Excessive
Noise
Cavitation
Verify airtight plumbing on the suction plumbing especially
fittings!
Clean out leaves or other debris from basket strainer (if
applicable).
Increase pipe size where possible.
Decrease suction pipe length, reduce the number of elbows, etc.
Verify hydraulic compatibility: i.e. pump and pipe are sized for
the system.
No Power
Wired incorrectly or an RCD has tripped.
Pump has been switched off at the controller.
Flow Restriction
Ensure valves are open.
Ensure plumbing is clear, including suction strainers,
check valves, etc.
Verify non return valve orientation and direction of permitted flow.

18
GUARANTEE
This product is guaranteed against defects in material and
workmanship for two years from the date of purchase, under normal
usage. The guarantee DOES NOT APPLY in case of improper use,
negligence, lack of maintenance or accidental damage to the pump.
If the pump fails due to a manufacturing fault within this period it will
be either repaired or replaced free of charge. Moving parts or wearable
parts including the impeller and any washers or sealing rings are not covered by the
guarantee and are available to order from your Evolution Aqua retailer.
Should your Evolution Aqua product stop working refer first to trouble shooting and
if this does not help, return the product to the place of purchase.
Liability is limited to replacement of the faulty product only. No other costs will
be reimbursed. This guarantee is not transferable and does not affect your
statutory rights.
Do not attempt to tamper with or access electrical components inside the pump
body. Doing so will invalidate the warranty.
The manufacturer or supplier shall not be responsible, or held liable for any
damages caused by defective components or materials of this product, or for loss
incurred by interruption of service, or any consequential/incidental damages and
expenses arising from the production, sale use or misuse of this product or any other
consequential loss.
Any warranty claim must be accompanied by a valid, dated proof of purchase.
Evolution Aqua, its distributors and dealers shall not be held liable for any loss of
fish, plants or any other livestock as a result of any failure or defect of this product.
The installation and use of your product outside of our recommendations as printed
in this manual may also void the warranty.
Evolution Aqua Ltd.
Evolution House, Kellet Close, Wigan, Lancashire, United Kingdom, WN5 0LP

19

Evolution Aqua Ltd
Kellet Close
Wigan
Lancashire
United Kingdom
WN5 0LP
www.evolutionaqua.com
Download instruction manuals for
all Evolution Aqua products
INSTRUCTION MANUALS
Find spare parts and accessories
for Evolution Aqua products
PARTS STORE
Locate your nearest Evolution Aqua
product stockist
STOCKISTS
Search Evolution Aqua Pond Owners Club
on Facebook to join the community
EA POND OWNERS CLUB
Keep updated with our latest news
at facebook.com/evolutionaqua
FACEBOOK
Read frequently asked questions
about Evolution Aqua products
FAQS
VISIT OUR WEBSITE
AND FOLLOW US
ON SOCIAL MEDIA
For all the latest Evolution Aqua news sign up to our email newsletter to have
the newest info delivered direct to your inbox. Keep up to date by following us on
social media, join our Pond Owners Club on Facebook or check out our website for
technical information and product advice at www.evolutionaqua.com.
Follow us on Instagram for updates
at instagram.com/evolution_aqua
INSTAGRAM
Watch our YouTube channel at
youtube.com/evolutionaqua
YOUTUBE
Other manuals for Varipump 10000
1
This manual suits for next models
2
Table of contents
Other Evolution Aqua Water Pump manuals
Popular Water Pump manuals by other brands

ALFRA
ALFRA 02120 operating instructions

Franklin Electric
Franklin Electric BT4 Series owner's manual

EBARA
EBARA 4WN Series Original instruction manual

EINHELL
EINHELL GC-DW 900 N Original operating instructions

Pressol
Pressol Pneumatic Oilpump 3:1 operating instructions

iPower
iPower AWP80C quick start guide