EVVR SS01 User manual

*Please see separate Smart Relay manual for
complete instructions. The Smart Switch
Sub-Assembly is an accessory part of In-wall
Relay Switch and only functional when
connected with the Smart Relay.
Rev. A-032021 P/N SS01
Instruction
Manual
Smart Switch ×1 Instruction Manual ×1
Caution: Read this manual before attempting to
install the device! Using this product in a manner
other than intended voids your warranty. Further, Evvr
is NOTliable for any damage incurred with the misuse
of this product.
Warning: Turn OFF electrical power from the breaker
box or electrical service panel before installing or
servicing this product. Improper use or installation
can cause SERIOUS INJURY, DEATH, or LOSS/DAM-
AGE OF PROPERTY.
Caution: Use this product in an indoor environment.
Caution: All installations of this device should be
performed by a qualified or licensed electrician!
Caution: Product must be installed on a 10A line.
Installation Instructions
Product Introduction
Smart Switch Sub-Assembly is an optional compo-
nent of the In-Wall Relay Switch when they are used
together. The Smart Switch Sub-Assembly is
designed to allow mechanical switch panels to work
with switch commands from the network. For
example, after turning off the lights with a mechani-
cal switch panel, you can turn on the lights through
network commands.
One Smart Relay can be connected to one or a series
Smart Switch Sub-Assembly (multiple point control).
One Smart Switch Sub-Assembly can be connected
to two circuits of loads, each of which must use one
Smart Relay.
TECHNICAL SPECIFICATIONS
Model number SS01
Input Voltage AC 85V~245V
Max. Load Power AC 110V/300W
AC 220V/600W
Min. Load Power No limit
Supported Switch Type Toggle, Momentary
Operating Temperature 0~40°C
(32°~104°F)
Relative Humidity 5~85% RH
Product Size (L*W*H) 33.5mm * 28.2mm * 17.3mm
(1.32in. x 1.11in. x 0.68in.)
Complete Accessories Include
Panel Connector Wire ×2
Fastening screws
Panel Connection port
Wire Connection port
SW1: External switch control for load
L : Power input for live wire
L1: Power output for live wire
L2: Power output for live wire
SW2: External switch control for load
NOTE: ‘SW1’ controls the ‘L1’
‘SW2’ controls the ‘L2’
With Smart Switch Sub-Assembly you can control Smart
Relay using traditional switch panel.
Smart Switch Sub-Assembly compatible with 1/2 gang
switch panel, and two Smart Switch Sub-Assemblies can
be installed to support 3/4 gang switch panel.
The diagram to the right shows the connection of wires. SW1 SW2
If the Smart Switch Sub-Assembly and Smart Relay are connected correctly, it should look like diagram
below. For more instructions on how to install the Smart Relay, please see the Smart Relay Manual.
In a single switch environment, please choose one of the installation methods to install on the L1
line according to your actual installation environment.
1Connect the wires to the switch panel
2Overall Diagram
Wiring a Single Light Switch
In-Wall Relay Switch
Smart Switch Sub-Assembly
Instruction Manual
N
L
L OUT
L
LOAD
SW1
N
N
L
L OUT
L
LOAD
SW1
Troubleshooting
This product must not be disposed of with your other
household waste. Instead, it is your responsibility to
dispose of your waste equipment by handing it over to
a designated collection point for the recycling of
waste electrical and electronic equipment. The
separate collection and recycling of your waste
equipment at the time of disposal will help to
conserve natural resources and ensure that it is
recycled in a manner that protects human health and
the environment. For more information about where
you can drop off your waste equipment for recycling,
please contact your local city office, your household
waste disposal service or the shop where you
purchased the product.
Disposal Instructions
Rev. A-032021 P/N SS01
Certifications (regional)
Note: All operations require a 5-second wait after the Smart Relay power up before use.
Peel off the paper from the adhesive and affix the Smart Switch
Sub-Assembly to the recommended location on the box.
Turn ON electrical power and check if the light can be turned on.
Caution: Before proceeding with this step, please ensure that wires are
connected correctly and the devices are operational.
Cannot switch lights on and off normally.Q1
The ‘panel connect wire’ from panel to Smart Switch
sub- assembly is not properly connected or the
wiring of the panel is not correct.
1.
2.
3.
4.
5.
Check whether the Smart Relay blue/red LED is
on when the load light is on. If the blue/red LED is
not on, it may be that the ‘live IN wire’ and ‘live OUT
wire’ of the main’s power line are not connected
properly.
If the Smart Relay blue/red LED is on, check
whether the panel terminal is properly connected.
Please refer to the installation instructions section
to check for proper wiring.
If only one load is connected to the Smart Switch
sub- assembly, please check whether the ‘power
output for live’ of the Smart Switch sub-assembly
is connected to ‘L1’.
Mechanical switch panel type identification error
(Please refer to “4 Set the type of switch panel".).
The light turns off automatically after a short
period of time (approximately 2½ minutes
or 150 seconds).
Q2
The power of the light may exceed the maximum
power (AC 110V/ 300W, AC 220V/600W). Please
check whether the power of the light exceeds the
maximum power.
After controlling the light wirelessly, the state
of the mechanical switch panel may be
different from the actual state of the light.
Q3
You need to operate the mechanical switch panel
twice to restore the light and the panel to the
same state.
3Fix Smart Switch Sub-Assembly on a flat, cleaned surface
Wiring a Double Light Switch
Warranty Policy
For warranty information, please visit
https://www.evvr.io/warranty
Note: The Smart Relay will leave the current network.
Quickly toggle the
switch button 10 times.
Quickly click the
switch button 5 times.
Working with
toggle switch button
Working with
momentary switch button
The device will leave the current network and re-enter pairing mode. At the
same time the indicator light will slowly flash blue and wait until pairing is
successful or timeout.
Set the Smart Relay into inclusion/pairing mode with Smart Switch Sub-Assembly
Operating Instructions
Please contact us for any technical issue
[email protected]
Recommended
placement
LOAD 1 (Black) and LOAD2 (White) are installed using two different connection methods. Please
choose the appropriate installation method according to your actual installation environment.
L - live wire
N - neutral wire
L OUT 1
L1 L2
L OUT 2
N
LOAD 2LOAD 1
SW1
SW2

Other EVVR Switch manuals

EVVR SRHW01 User manual

EVVR

EVVR SRHW01 User manual

EVVR SRB01 User manual

EVVR

EVVR SRB01 User manual

EVVR SRB01 User manual

EVVR

EVVR SRB01 User manual

Popular Switch manuals by other brands

Edge-Core ECS1100-5P quick start guide

Edge-Core

Edge-Core ECS1100-5P quick start guide

ABB E-Hub 2.0 user manual

ABB

ABB E-Hub 2.0 user manual

VoiSmart NT-3010-01-16POE Quick installation guide

VoiSmart

VoiSmart NT-3010-01-16POE Quick installation guide

LANGPAI HRY-260 user guide

LANGPAI

LANGPAI HRY-260 user guide

Sierra Monitor Corporation ISE30 Series Technical specification

Sierra Monitor Corporation

Sierra Monitor Corporation ISE30 Series Technical specification

Linksys SR216 user guide

Linksys

Linksys SR216 user guide

StarTech.com ICUSB23208FD manual

StarTech.com

StarTech.com ICUSB23208FD manual

Matrix Switch Corporation MSC-HD161DES product manual

Matrix Switch Corporation

Matrix Switch Corporation MSC-HD161DES product manual

GE RAK204 installation instructions

GE

GE RAK204 installation instructions

CAMBRIONIX PowerPad15s user manual

CAMBRIONIX

CAMBRIONIX PowerPad15s user manual

ENFORCER VA-1102B-WQ Manual guide

ENFORCER

ENFORCER VA-1102B-WQ Manual guide

Brigade CQS-100C owner's guide

Brigade

Brigade CQS-100C owner's guide

HP 263924-002 user guide

HP

HP 263924-002 user guide

Brocade Communications Systems ICX 7250-24G Hardware installation guide

Brocade Communications Systems

Brocade Communications Systems ICX 7250-24G Hardware installation guide

FS S2805S Series quick start guide

FS

FS S2805S Series quick start guide

UWT RFnivo RF 8000 Series Technical Information/Instruction manual

UWT

UWT RFnivo RF 8000 Series Technical Information/Instruction manual

Dahua DH-PFS3206-4P-96 user manual

Dahua

Dahua DH-PFS3206-4P-96 user manual

Vetus BPSPE installation instructions

Vetus

Vetus BPSPE installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.