FS S2805S Series User manual

GIGABIT SFP L2 MANAGED SWITCHES
V1.0
Quick Start Guide
Guide de Démarrage Rapide
Quick Start Anleitung
S2805S Series Switches
SWITCHS MANAGEABLE GIGABIT SFP L2
SFP Gigabit L2 Managed Switches
RESET
Link/Act
Link/Act
PoE
PoE
1 3 5 7 9 11 13 15 17 19 21 23
PWR 2 4 6 8 10 12 14 16 18 20 22 24
25
26
27
28
CONSOLE
21 65 87
43 109 1211 1413 1615 2625 2827
1817 2019 2221 2423
SFP
S2805S-24TF-P PoE+
SYS
SYS 1 3 5 7 9 11 13 15 17 19 21 23
PWR 2 4 6 8 10 12 14 16 18 20 22 24
25 26 27 28
RESET
Link/Act
21 65 87
43 109 1211 1413 1615 1817 2019 2221 2423
CONSOLE
25 26 27 28
SFP
Link/Act
S2805S-24TF

Introduction
M3 Screw x8
EN
Thank you for choosing S2805S Series Managed Switches. This guide is designed to familiarize you
with the layout of the switches and describes how to deploy the switches in your network.
Accessories
S2805S-24TF-P/S2805S-24TF
Rubber Pad x4Power Cord x1 Mounting Bracket x2
S2805S-24TF
SYS 1 3 5 7 9 11 13 15 17 19 21 23
PWR 2 4 6 8 10 12 14 16 18 20 22 24
25 26 27 28
RESET
Link/Act
21 65 8743 109 1211 1413 1615 1817 2019 2221 2423
CONSOLE
25 26 27 28
SFP
Link/Act
S2805S-24TF
S2805S-24TF-P
RESET
Link/Act
Link/Act
PoE
PoE
1 3 5 7 9 11 13 15 17 19 21 23
PWR 2 4 6 8 10 12 14 16 18 20 22 24
25
26
27
28
CONSOLE
21 65 8743 109 1211 1413 1615 2625 28271817 2019 2221 2423
SFP
S2805S-24TF-P PoE+
SYS
1

EN
Front Panel Ports
Port/Button Description
Reset
SFP
CON
RJ45
Press down the button for 5 seconds to restore the switch to its
original factory default settings.
100/1000Mbps SFP port
For monitoring and configuring the switch.
Connect to the device with a bandwidth of 10Mbps, 100Mbps or
1000Mbp.
Hardware Overview
S2805S-24TF-P
S2805S-24TF
RESET
Link/Act
Link/Act
PoE
PoE
1 3 5 7 9 11 13 15 17 19 21 23
PWR 2 4 6 8 10 12 14 16 18 20 22 24
25
26
27
28
CONSOLE
21 65 8743 109 1211 1413 1615 2625 28271817 2019 2221 2423
SFP
S2805S-24TF-P PoE+
SYS
RJ45 SFP
Console
RESET
SYS 1 3 5 7 9 11 13 15 17 19 21 23
PWR 2 4 6 8 10 12 14 16 18 20 22 24
25 26 27 28
RESET
Link/Act
21 65 8743 109 1211 1413 1615 1817 2019 2221 2423
CONSOLE
25 26 27 28
SFP
Link/Act
S2805S-24TF
Console SFPRJ45RESET
2

EN
LED State Description
PWR
SYS
Link/Act
(1-24)
Link/Act
(25-28)
PoE
(1-24)
Off
Off
Off
Solid green
Solid orange
Blinking
Off
Off
No PD is connected to the corresponding port,
or no power is supplied according to the power
limits of the port.
A Powered Device is connected to the port,
which supply power successfully.
Solid yellow
The port is NOT connected.
The port is connected at 1000Mbps.
The port is transmitting or receiving data.
Solid green
Blinking
Blinking green System is starting or the system starts
successfully.
Power Off
Power On
System not started.
The port is NOT connected.
The port is connected at 1000Mbps.
The port is connected at 100/10Mbps.
The port is transmitting or receiving data.
Solid green
Front Panel LEDs
S2805S-24TF-P
S2805S-24TF
Blinking The PoE power circuit may be in short or the
power current may be overloaded.
3
SYS 1 3 5 7 9 11 13 15 17 19 21 23
PWR 2 4 6 8 10 12 14 16 18 20 22 24
25 26 27 28
RESET
Link/Act
21 65 8743 109 1211 1413 1615 1817 2019 2221 2423
CONSOLE
25 26 27 28
SFP
Link/Act
S2805S-24TF
PWR
SYS Link/Act
SYS
RESET
Link/Act
Link/Act
PoE
PoE
1 3 5 7 9 11 13 15 17 19 21 23
2 4 6 8 10 12 14 16 18 20 22 24
25
26
27
28
CONSOLE
21 65 8743 109 1211 1413 1615 2625 28271817 2019 2221 2423
SFP
S2805S-24TF-P PoE+
PWR
PoE
SYS Link/Act
Link/Act
PWR
SYS

EN
Phillips screwdriver.
Standard-sized, 19" wide rack with a minimum of 1U height available.
Category 5e or higher RJ-45 Ethernet cables, fiber optical cables, and console cable for connecting
network devices.
Back Panel
S2805S-24TF-P
S2805S-24TF
Installation Requirements
Before you begin the installation, make sure that you have the followings:
Grounding Terminal
AC Power Connector
50/60Hz
100-240V AC
Grounding Terminal
50/60Hz
100-240V AC
AC Power Connector
4
Note: Only S2805S-24TF-P has PoE status indicators.

EN
1. Attach four rubber pads to the bottom.
2. Gently place the switch on a desk.
Mounting the Switch
Site Environment:
Do not operate it in an area that exceeds an ambient temperature of 50°C.
The installation site must be well ventilated. Ensure that there is adequate air flow around
the switch.
Be sure that the switch is level and stable to avoid any hazardous conditions.
Do not install the equipment in a dusty environment.
The installation site must be free from leaking or dripping water, heavy dew, and humidity.
Ensure rack and working platforms are well earthed.
Desk Mounting
RESET
Link/Act
Link/Act
PoE
PoE
1 3 5 7 9 11 13 15 17 19 21 23
PWR 2 4 6 8 10 12 14 16 18 20 22 24
25
26
27
28
CONSOLE
21 65 87
43 1091211 1413 1615 2625 2827
1817 2019 2221 2423
SFP
S2805S-24TF-P
PoE+
SYS
Po
P E
Link/Act
Link/Act
E
o
25
26
27
28
5

EN
Rack Mounting
1. Fix the mounting brackets to the two sides of the switch with supplied M3 screws.
2. Attach the switch to the rack with four M6 screws and cage nuts.
RESET
CONSOLE
21 65 87
43 109 1211 1413 1615 2625 2827
1817 2019 2221 2423
SFP
6
Po
P E
RESET
Link/Act
Link/Act
E
o
25
26
27
28
CONSOLE
21 65 8743 109 12
11 1413 1615 2625 28271817 2019 2221 2423
SFP
24
23
21 22
19 20
15
11 12 13 14 16 17 18 25 26 27 28
SFP
CONSOLE

1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which the
switch is mounted.
2. Fix the grounding lug to the grounding point on the back panel of the switch with the washers and
screws.
CAUTION: The earth connection cannot be removed unless all supply connections have
been disconnected.
EN
Grounding the Switch
7
100-240V AC50/60Hz

1. Plug the AC power cord into the power port on the back panel of the switch.
2. Connect the other end of the power cord to an AC power source.
WARNING: Do not connect power cable while the power is on.
EN
Connecting the Power
Link/Act
Link/Act
E
o
1 3 5 7 9 1 25
26
27
28
SYS
8
100-240V AC50/60Hz

1. Plug the compatible SFP transceiver into the SFP port.
2. Connect a fiber optic cable to the fiber transceiver. Then connect the other end of the cable to
another fiber device.
1. Connect an Ethernet cable to a RJ45 port of IP cameras, IP telephone, Access Points (AP), or other
network devices.
2. Connect the other end of the Ethernet cable to the RJ45 port of the switch.
EN
Connecting the RJ45 Ports
Connecting the SFP Ports
RESET
CONSOLE
21 65 87
43 109 1211 1413 1615 2625 28271817 2019 2221 2423
SFP
Po
P E
1
PWR
13 15 17 19 21 23
2 4 6 8 10 12 14 16 18 20 22 24
S2805S-24TF-P PoE+ RESET
Link/Act
Link/Act
E
o
1 3 5 7 9 1 25
26
27
28
CONSOLE
21 65 87
43 109 1211 1413 1615 2625 2827
1817 2019 2221 2423
SFP
SYS
9

Step 1: Connect the computer to any RJ45 port of the switch with the network cable.
Step 2: Set the IP address of the computer to 192.168.1.x. (“x”is any number from 2 to 254.)
Step 3: Open a browser, type http://192.168.1.1, and enter the default username and password,
admin/admin.
Configuring the Switch via the Web-based Interface
Internet Protocol Version 4 (TCP/IPv4) Properties
Cancel
Advanced...
OK
x
General
You can get IP settings assigned automatically if your network
supports this capability. Otherwise, you need to ask your network
a dministrator for the appropriate IP settings
Obtain an IP address automatically
Use the following IP address:
IP address:
Subnet mask:
Default gateway
Obtain DNS server address automatically
Use the following DNS server address:
Validate settings upon exit
192 . 168 . 1 . 2
225 . 225 . 225 . 0
. . .
Preferred DNS server . . .
Alternate DNS server . . .
?
admin
English
Remember Password
Login
EN
Configuring the Switch
Step 4: Click Login to display the web-based configuration page.
10

Troubleshooting
With compatible cables and transceivers, the port still cannot work, please try to modify the port
mode to adapt.
SFP Port is not Working.
1. Test network connectivity through ping.
2. If the network is reachable, try restarting the switch.
3. Check if the corresponding service is enabled.
The Switch fails in remote connection.
1. Ensure all switch ports are in normal state.
2. Check whether the switch can read the DDM information.
3. Check whether the port speed setting is correct.
4. Try to loop the switch cable.
The Port is not Working, the LED Indicator is Off.
1. Replace the twisted pair cable.
2. Check that whether the port configuration has the common working mode with the connected
switch.
RJ45 port doesn’t connect or it is erroneous in receiving/transmitting data.
Online Resources
Download
Help Center
Contact Us
https://www.fs.com/products_support.html
https://www.fs.com/service/fs_support.html
https://www.fs.com/contact_us.html
EN
11

FS ensures our customers that if there are any damage or faulty items due to our workmanship, we
will offer a free return within 1 month from the day you receive your goods. This excludes any custom
made items or tailored solutions.
Return: If you want to return item(s), information on how to return can be found at
https://www.fs.com/policies/day_return_policy.html
Warranty: This product enjoys 2 years limited warranty against defect in materials or
workmanship. For more details about warranty, please check at
https://www.fs.com/policies/warranty.html
2
EN
Product Warranty
12

DE
Einführung
M3-Schraube x8
Vielen Dank, dass Sie sich für Managed Switches der S2805S-Serie entschieden haben. Diese
Anleitung soll Sie mit dem Aufbau der Switches vertraut machen und beschreibt, wie Sie die Switches
in Ihrem Netzwerk einsetzen.
Zubehör
S2805S-24TF-P/S2805S-24TF
Gummiunterlage x4Netzkabel x1 Montagebügel x2
13
S2805S-24TF
SYS 1 3 5 7 9 11 13 15 17 19 21 23
PWR 2 4 6 8 10 12 14 16 18 20 22 24
25 26 27 28
RESET
Link/Act
21 65 8743 109 1211 1413 1615 1817 2019 2221 2423
CONSOLE
25 26 27 28
SFP
Link/Act
S2805S-24TF
S2805S-24TF-P
RESET
Link/Act
Link/Act
PoE
PoE
1 3 5 7 9 11 13 15 17 19 21 23
PWR 2 4 6 8 10 12 14 16 18 20 22 24
25
26
27
28
CONSOLE
21 65 8743 109 1211 1413 1615 2625 28271817 2019 2221 2423
SFP
S2805S-24TF-P PoE+
SYS

DE
Anschlüsse an der Vorderseite
Port/Taste Beschreibung
Reset
SFP
CON
RJ45
Halten Sie die Taste 5 Sekunden lang gedrückt, um den Switch auf
seine ursprünglichen Werkseinstellungen zurückzusetzen.
100/1000Mbps SFP Port
Zum Überwachen und Konfigurieren des Switches.
Verbindung zum Gerät mit einer Bandbreite von 10Mbps, 100Mbps
oder 1000Mbp.
Hardware-Übersicht
S2805S-24TF-P
S2805S-24TF
14
RESET
Link/Act
Link/Act
PoE
PoE
1 3 5 7 9 11 13 15 17 19 21 23
PWR 2 4 6 8 10 12 14 16 18 20 22 24
25
26
27
28
CONSOLE
21 65 8743 109 1211 1413 1615 2625 28271817 2019 2221 2423
SFP
S2805S-24TF-P PoE+
SYS
SFP
Console
SYS 1 3 5 7 9 11 13 15 17 19 21 23
PWR 2 4 6 8 10 12 14 16 18 20 22 24
25 26 27 28
RESET
Link/Act
21 65 8743 109 1211 1413 1615 1817 2019 2221 2423
CONSOLE
25 26 27 28
SFP
Link/Act
S2805S-24TF
Console
RJ45 SFP
RESET
RJ45RESET

DE
LED Status Beschreibung
PWR
SYS
Link/Act
(1-24)
Link/Act
(25-28)
PoE
(1-24)
Aus
Aus
Aus
Durchgehend Grün
Durchgehend Orange
Blinkt
Aus
Aus
An den entsprechenden Anschluss ist kein PD
angeschlossen, oder es wird entsprechend den
Leistungsgrenzen des Ports kein Strom geliefert.
Ein eingeschaltetes Gerät ist mit dem Port
verbunden, der erfolgreich Strom liefert.
Durchgehend Gelb
Der Port ist NICHT verbunden.
Der Port ist mit 1000Mbps angeschlossen.
Der Port sendet oder empfängt gerade Daten.
Durchgehend Grün
Blinkt
Blinkt Grün Das System wird gestartet oder das System
startet erfolgreich.
Ausschalten.
Einschalten.
System ist nicht gestartet.
Der Port ist NICHT verbunden.
Der Port ist mit 1000Mbps angeschlossen.
Der Port ist mit 100/10Mbps angeschlossen.
Der Port sendet oder empfängt Daten.
Durchgehend Grün
LEDs an der Vorderseite
Blinkt
Der PoE-Stromkreis hat möglicherweise einen
Kurzschluss oder die Stromversorgung ist
überlastet.
S2805S-24TF-P
S2805S-24TF
15
SYS
RESET
Link/Act
Link/Act
PoE
PoE
1 3 5 7 9 11 13 15 17 19 21 23
2 4 6 8 10 12 14 16 18 20 22 24
25
26
27
28
CONSOLE
21 65 8743 109 1211 1413 1615 2625 28271817 2019 2221 2423
SFP
S2805S-24TF-P PoE+
PWR
PoE
SYS Link/Act
Link/Act
PWR
SYS
SYS 1 3 5 7 9 11 13 15 17 19 21 23
PWR 2 4 6 8 10 12 14 16 18 20 22 24
25 26 27 28
RESET
Link/Act
21 65 8743 109 1211 1413 1615 1817 2019 2221 2423
CONSOLE
25 26 27 28
SFP
Link/Act
S2805S-24TF
PWR
SYS Link/Act

DE
Rückseite
S2805S-24TF-P
S2805S-24T4F
Installationsvoraussetzungen
Bevor Sie mit der Installation beginnen, vergewissern Sie sich, dass Sie
über die folgenden Dinge verfügen:
Kreuzschlitzschraubendreher.
Ein 19"-Rack in Standardgröße mit einer Mindesthöhe von 1 HE.
RJ-45-Ethernet-Kabel der Kategorie 5e oder höher, Glasfaserkabel und Konsolenkabel für den
Anschluss von Netzwerkgeräten.
HINWEIS: Nur S2805S-24TF-P verfügt über PoE-Statusanzeigen.
Erdungsklemme
AC-Netzanschluss
50/60Hz
100-240V AC
Erdungsklemme
50/60Hz
100-240V AC
AC-Netzanschluss
16

DE
1. Bringen Sie vier Gummipads an der Unterseite an.
2. Legen Sie den Switch vorsichtig auf einen Tisch.
Montage des Switches
Standortumgebung:
Betreiben Sie das Gerät nicht in einem Bereich, in dem die Umgebungstemperatur 50°C übersteigt.
Der Installationsort muss gut belüftet sein. Stellen Sie sicher, dass um den Switch herum ein
ausreichender Luftstrom herrscht.
Achten Sie darauf, dass der Switch eben und stabil steht, um gefährliche Bedingungen zu
vermeiden.
Installieren Sie das Gerät nicht in einer staubigen Umgebung.
Der Installationsort muss frei von austretendem oder tropfendem Wasser, starkem Tau und
Feuchtigkeit sein.
Stellen Sie sicher, dass Gestell und Arbeitsbühnen gut geerdet sind.
Montage auf dem Tisch
RESET
Link/Act
Link/Act
PoE
PoE
1 3 5 7 9 11 13 15 17 19 21 23
PWR 2 4 6 8 10 12 14 16 18 20 22 24
25
26
27
28
CONSOLE
21 65 87
43 1091211 1413 1615 2625 2827
1817 2019 2221 2423
SFP
S2805S-24TF-P
PoE+
SYS
17
Po
P E
Link/Act
Link/Act
E
o
25
26
27
28

DE
Rack-Montage
1. Befestigen Sie die Montagehalterungen mit den mitgelieferten M3-Schrauben an den beiden Seiten
des Switches.
2. Befestigen Sie den Switch mit vier M6-Schrauben und Käfigmuttern am Rack.
18
RESET
CONSOLE
21 65 87
43 109 1211 1413 1615 2625 2827
1817 2019 2221 2423
SFP
Po
P E
RESET
Link/Act
Link/Act
E
o
25
26
27
28
CONSOLE
21 65 8743 109 12
11 1413 1615 2625 28271817 2019 2221 2423
SFP
24
23
21 22
19 20
15
11 12 13 14 16 17 18 25 26 27 28
SFP
CONSOLE

DE
1. Schließen Sie ein Ende des Erdungskabels an eine geeignete Erdung an, z. B. an das Rack, in dem der
Switch montiert ist.
2. Befestigen Sie die Erdungslasche mit den Unterle gscheiben und Schrauben an dem Erdungspunkt
auf der Rückseite des Switches.
Erdung des Switches
ACHTUNG: Der Erdungsanschluss kann nur entfernt werden, wenn alle
Versorgungsanschlüsse getrennt wurden.
19
100-240V AC50/60Hz
Table of contents
Languages:
Other FS Switch manuals

FS
FS S1900-5T User manual

FS
FS S5900-24S4T2Q User manual

FS
FS S5800-48F4SR-DC User manual

FS
FS S5500-48T8SP User manual

FS
FS IES3110 Series User manual

FS
FS PoE+ Series User manual

FS
FS S5500-48T8SP Operating instructions

FS
FS PoE+ Series Operating instructions

FS
FS S1900-16TP User manual

FS
FS SC9405 Series User manual
Popular Switch manuals by other brands

ZyXEL Communications
ZyXEL Communications GS1915-8 quick start guide

Generac Power Systems
Generac Power Systems HTS owner's manual

Edge-Core
Edge-Core ECS4510-52P installation guide

Kathrein
Kathrein EXD 1524 manual

Versitron
Versitron S72450 installation guide

Ex-Tech
Ex-Tech XPEW Series operating instructions