EXFO IQ-206 User manual

Artisan Technology Group is your source for quality
new and certied-used/pre-owned equipment
• FAST SHIPPING AND
DELIVERY
• TENS OF THOUSANDS OF
IN-STOCK ITEMS
• EQUIPMENT DEMOS
• HUNDREDS OF
MANUFACTURERS
SUPPORTED
• LEASING/MONTHLY
RENTALS
• ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
REMOTE INSPECTION
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specications, manuals, and documentation
Contact us: (888) 88-SOURCE | sales@artisantg.com | www.artisantg.com
SM
View
Instra

IQ-206 ExpansionUnit
InstructionManual
November
1
995
PIN: MAN-057-1.2AN
Second Edition
Software Version 1.0
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

All rights reserved. No part of this publication may be reproduced, stored in
a
retrieval system or transmitted,in any form by any means, electronic,
mechanical,photocopying,recording or otherwise, without the prior written
permission of EXFO E.O. Engineering Inc.(EXFO).
Informationfurnishedby EXFO is believed to be accurate and reliable.
However,no responsibilityis assumed by EXFO for its use nor for any
infringementsof patents or other rights of third parties which may result from
its use. No licenseis granted by implicationor otherwiseunder any patent
-
rights of EXFO.
EXFO's CommerceAnd Government Entities (CAGE)code under the North
Atlantic Treaty Organization(NATO)is OL8C3.
The informationcontainedin this document is subject to change without
notice.
O
1995
EXFO Electro-OpticalEngineeringInc.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

General Safety Information
The following safety precautions must be observed during the operation and
servicing of the unit. Failure to comply with these precautions or with specific
indications elsewhere in this manual violates safety standards of intended use
of the unit. EXFO assumes no liability for the user's failure to comply with
these requirements.
This is a Safety Class
1
instrument manufactured and tested according to
international safety standards.
Safety
Precautions
Before powering ON, we strongly suggest that you read and comply with the
recommendations given in the sections
General Safety Information
and
Module Setup.
These instructions and indications must be followed to ensure
safe operation of the unit.
In addition, please follow the safety precautions listed below:
Unit covers cannot be removed during operation.
Before powering ON the unit, all grounding terminals, extension cords,
and devices connected to it should be connected to a protective ground via
a ground socket. Any interruption of the protective grounding will cause a
potential shock hazard and possible personal injury.
Whenever the ground protection is impaired, the unit must not be used and
be secured against any accidental or unintended operation.
Only fuses with the required rated current and specified type (normal
blow, time delay, etc.) may be used for replacement. Do not use repaired
fuses or short-circuit fuseholders.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Any adjustments, maintenance, and repair of opened units under voltage
-
should be avoided and carried out only by skilled personnel aware of the
hazard involved. Do not attempt internal service or adjustment unless
another person qualified in first aid is present. Do not replace any
components while power cable is connected.
Operation of any electrical instrument around flammable gases or fumes
constitutes a major safety hazard.
Installation of substitute parts or modification of the unit should be carried
out by authorized personnel only.
Capacitors inside the unit may be charged even if the unit has been
disconnected from its electrical supply.
WARNING
Toavoid electrical shock, do not operate the unit
if
there are signs of
damage to any part of the outer surface (covers,panels, etc.).
AC
Requirements
The
IQ-203lIQ-206
can operate from any single-phase
AC
power source
between
100
V and
260
V
for the
IQ-203(47
to
63
Hz), and
100
V
to
120
V
and
200
V to
240
V for the
IQ-206 (50160
Hz).
The maximum power
consumption is
85
VA for the
IQ-203
and
210
VA for the
IQ-206,
with all
options installed.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Power
Cable
This unit uses an international safety standard three-wire power cable. This
cable serves as a ground when connected to an appropriate
AC
power
receptacle. The type of power cable supplied with each unit is determined
according to the country of destination. The figure below illustrates the
different power cables available.
SOUTHAFRICA UNITEDSTATES
Power
Cable
Plug
Identification
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

WARNING
A
Toavoid serious injury, thefollowing precautions must be observed before
powering
ON
the unit.
If
the unit is to bepowered via anauto transformerfor voltage
reduction, the common terminal must be connected to the grounded
power source pole.
Insert thepower cableplug into apower outlet with aprotective ground
contact. Do not use an extension cord without aprotective conductor.
Before powering
ON
the unit, theprotective ground terminal of the unit
mustbe connected to aprotective conductor using the unitpower cord.
Do nottamper with theprotective ground terminal.
The following work should be carried out by a qualified electrician:
The color coding used in the cable depends on the cable. If a new plug is
being connected,it should meet the local safetyrequirements and include
the following features:
1.
Adequate load-carryingcapacity
2.
Ground connection
3.
Cable clamp
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

.
Table of Contents
Page
..........................................................................................................
1 INTRODUCTION 1-1
.............................................................................................
1.1 IQ-200ProductLine 1-1
............................................................................................
1.2 Listof Abbreviations 1-2
...................................................................................
1.3 Unpackingand Inspection 1-2
..............................................................................................
1.4Safety Conventions 1-3
.......................................................................................................
.
15 Getting Help 1-4
................................................................................................
2
PRODUCTOVERVIEW 2-1
............................................................
2.1 Description of the IQ-206Expansion Unit 2-1
.......................................................................................
2.2 Front Panel Description 2-2
........................................................................................
2.3 Back Panel Description 2-3
3 INSTALLATION
...........................................................................................................
3-1
.
................................................................................................
3.1 IQ-206Installation 3-1
...........................................................................
3.2 IQ-203 Positioningand Cooling 3-2
.............................................................................
3.3 IQ Series ModuleInstallation 3-3
4 OPERATION
................................................................................................................
4-1
.............................................................................................................
4.1 Activation 4-1
....................................................................................................................
5 MODULES 5-1
...............................................................................................
5.1 IQ Series Modules 5-1
6 MAINTENANCE AND TROUBLESHOOTING
.............................................................
6-1
6.1 Maintenance
........................................................................................................
6-1
6.2 Fuse Replacement
...............................................................................................
6-1
6.3 Troubleshooting
...................................................................................................
6-2
......................................................................
7
IQ-206TECHNICAL SPECIFICATIONS
7-1
7.1 SpecificationsPage
.............................................................................................
7-1
\
8 GENERAL INFORMATION
....................................................................................
8-1
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Page
...............................................................................................................
8.1
Warranty 8.1
8.2 Liability
.................................................................................................................
8-2
............................................................................................................
8.3
Exclusions 8-2
8.4
Certification
..........................................................................................................
8-3
8.5
Serviceand Repairs(UnderWarranty
or
Other)
..................................................
8-3
8.6
Transportation and Storage
..................................................................................
8-4
9
CUSTOMER COMMENTS
............................................................................................
9-1
9.1
IQ
Comments
.......................................................................................................
9-1
10INDEX
.......................................................................................................................
10-1
viii
Expansion
Unit
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Page
Figure
2-1
.
ProductNameplate
........................................................................................
2-1
Figure2-2. IQ-206 Front Panel
.......................................................................................
2-2
Figure2-3. IQ-206Back Panel
........................................................................................
2-3
Figure
3-1.
IQ-206Positioningand Cooling
.....................................................................
3-2
Figure
3-2.
IQ-206Cover Plate Bottom Groove
..............................................................
3-3
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

IQ-200
Product
Line
1.1
10-200
Product
Line
EXFO E.O. Engineering Inc. (EXFO) is pleased to introduce the IQ-206
Expansion Unit as part of the Optical Test System IQ-200 Integrated
PC/WINDOWSTMmodular test system family. The 14-200 product line
consists of the IQ-203 Optical Test System mainframe, the IQ-206 Expansion
Unit, and the IQ Series modules.
Refer to the IQ-206 and IQ Series modules instruction manuals for specific
operatinginstructions on these products.
EXFO's commitmentto superior design in all its fiber-optic instrumentation is
respected throughoutthe industry and is based on four goals:
1.
Simple operation.
2. Extensivefeatures.
3.
Reliable performance.
4.
Dedicated interest in customer needs.
The IQ-206 Expansion Unit will provide many years of reliable operation.
In order to benefit fully from the many features offered
by
the IQ-206, it is
important to read the contents of this instruction manual carefully.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

List of Abbreviations
1.2
List
of
Abbreviations
--
The following abbreviations
are
used throughout this manual:
AC
AlternatingCurrent
FOA Fiber-optic Adapter
GPIB General Purpose Interface Bus
LED Light EmittingDiode
VA Voltampere
VAC Volt per Alternating Current
1.3
Unpackingand Inspection
The IQ-206 is delivered with the following standard items:
IQ-206 Expansion Unit
IQ-206 Instruction Manual
Interface (expansion)cable
Two IQ User's Guidebinders with dividers
AC power cord
The IQ-206 Expansion Unit has been thoroughly inspected before shipment. If
any damage has occurredduring transportation or if any item is missing, please
notify EXFO immediately.
The following items are optional (please verify invoice):
IQ Series modules with their respective FOAs and test jumpers
IQ-203 OpticalTest System
1-2
Expansion
Unit
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Safety Conventions
'I
1.4
Safety Conventions
WARNING, CAUTION,
and
IMPORTANT
The followingconventions should be clearly understood before operating
the
unit:
WARNING
Refers to a potential personal hazard. It requires a procedure
which, if not correctlyfollowed, may result in bodily
harm
or
injury. Do not proceed beyond a
WARNING
unless the
required conditions are fully understood and met.
CAUTION
Refers to a potential product hazard. It requires a procedure
which, if not correctly followed, may result in irreparable
component damage. Do not proceed beyond a
CAUTION
unless the required conditions are fully understood and met.
IMPORTANT
Refers to any informationregarding the operation of the
product which should not be overlooked.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Getting
Help
1.5
Getting
Help
If any difficulty is encountered while operating the unit, please call
EXFO
at
one of the officeslisted below. The Product Support Group is available from
7:30 a.m. to 8:00 p.m.
EST,
Monday to Friday.
Product Support Group
USA and Canada
Tel.: 1-800-663-EXFO
Fax: 1-418-683-2170
International
Tei.: 418-683-0211
Fax: 418-683-2170
EXFO
Europe
Tel.: 33-1-34.63.00.20
Fax: 33-1-34.65.90.93
1-4
Expansion
Unit
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Description
of
the
IQ-206
Expansion Unit
2.1
Descriptionof the
IQ-206
Expansion Unit
The
IQ-206
Expansion Unit can integrate six
IQ
series modules. Up to four
IQ-206
Expansion Units can be linked to an
IQ-203
Optical Test System. The
IQ-206
Expansion Unit is dependent on the
IQ-203
and cannot function
without it.
The product nameplate, shown in Figure
2-
1,
is located on the rear panel of the
IQ-206.
The nameplate provides:
the detailed part number
(PM)
identifying configuration and options
the serial number
(SIN)
the date of manufacture
(Mfg.
date)
the
product version
(Ver.)
Figure
2-
1.
Product Nameplate
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

PRODUCTOVERVIEW
Front Panel Description
2.2
Front Panel Description
Figure
2-2
illustrates the
IQ-206
front panel characteristics.
MODULES
Figure2-2. IQ-206 Front Panel
FrontPanel Items
ONIOFF
Button
IQ-206
Sequential
2-2 ExpansionUnit
Description
Press this button to power the unit
ONIOFF.
Indicates the sequential position
of
the unit
Position Display within a complete
IQ-203
+
IQ-206
system
(position from
1
to
4).
Refer to
IQ-203
instruction manual.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

PRODUCTOVERVIEW
Back Panel Description
--
-
2.3
Back Panel Description
Figure
2-3
illustrates the
IQ-206
back panel.
Fuse
AC
Outlet
I
+
--
u
Expansion
\,
Unit Ports:
In
Power ~ub~l~Selector
Figure
2-3.
10-206
Back
Panel
Use the power supply selector shown in Figure
2-3
to choose the
appropriate power supply:
110
V
or
220
V,
as indicated.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

IQ-206 Installation
3.1
IQ-206
Installation
CAUTION
NEVER INSERT ORREMOVE ANY MODULE WHEN THEIQ-203/
12-206IS POWEREDON. THIS WILLRESULT IN ZMMEDIATE
IRREPARABLE DAMAGE TO THEMODULE AND THE
IQ-203/1Q-206.
To
install
the
IQ-206:
1.
Connect the
IQ-206
AC
power cords
2.
Connect interface cables to
IQ-203
Optical Test System and other (if any)
IQ-206
Expansion Unit:
Connect interface cable from
IQ-203
into
IQ-206 "IN"
port.
Connect interface cable for next
IQ-206
unit to
"OUT"
port of first
IQ-206
unit and to
"IN"
port of second
IQ-206
unit. Repeat for
additional
IQ-206
ExpansionUnits.
3.
Keep
IQ-206
and
IQ-203
powered OFF.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Table of contents
Other EXFO Control Unit manuals
Popular Control Unit manuals by other brands

Frequency Central
Frequency Central State 700 Build documentation

Graco
Graco 24L096 instructions

Comunello
Comunello CU-230V-1M Installation and user manual

EVSE
EVSE 3727 Series User manual and installation guide

YOKOGAWA
YOKOGAWA FN310 user manual

Rockwell Automation
Rockwell Automation 1794-OB8 installation instructions

Automationdirect.com
Automationdirect.com Productivity 2000 P2-08DA-2 manual

VIPA
VIPA SPEED7 CPU 313SCDPM manual

Wiznet
Wiznet WIZ107SR user manual

BIFFI
BIFFI ICON3000 Series Installation, operation and maintenance manual

ABB
ABB Symphony Harmony Series Instruction

Helios
Helios AIR1-ULM Installation and operating instructions