Installation & Maintenance
H572D / H570D / H566D / H566S
CLASS I, IP65
EL-IM004.00 Page 1 of 2
Installation
The Eye Lighting H572D, H570D and H566 series’ are
floodlights for outdoor (permanent) use, designed to be
operated in conjunction with remote control gear appropriate
for the lamp type and wattage in use.
The floodlight is designed to be securely mounted on a suitably
solid horizontal surface using 2x M16 bolts.
Screw the lamp in to its full extent, ensuring that it’s secure,
but not over tightened.
Ensuring the gasket and joining surfaces are clean, secure the
lamp carrier to the main body by pivoting the three screws and
tightening the wing nuts evenly. Ensure the chain is attached.
Incoming supply cables from the control gear are terminated in
the termination box via the 20mm threaded entry.
To maintain the integrity of the enclosure’s protection against
dust and moisture ingress, cable glands or conduit fittings
rated at least IP65 must be used.
Check that the cable glands are tightened correctly.
Floodlights must be installed within the maximum
recommended distance to the control gear, as applicable to
the type used.
These instructions should be retained by the floodlight owner
for reference, and made available as necessary, to ensure
future maintenance is carried out correctly.
Aiming
Adjust the horizontal aiming of the floodlight by loosening the
anchor and swivel screws (not supplied) fixing the base to the
mounting surface. Using the markings on the base plate as a
guide, adjust to the required angle and tighten the screws.
Adjust the tilt by loosening the screws at the pivot point and
releasing the locking lever. Using the markings on the pivot
plate, adjust the floodlight to the required tilt angle and hold in
place by tightening the lever. Check the tilt angle is correct
and tighten the screws.
As an alternative to using the markings on the base and pivot
plates, the included aiming device may be used during this
process to aim at a specific point.
General Operation and Maintenance
Failed lamps are to be replaced promptly, or the circuit
isolated, to avoid possible control gear damage. Continual
operation on supply voltage above that nominated on the
control gear will reduce expected lamp and component life.
Clean excessive build up of foreign material from outer
surfaces of the body. Clean the lens as required with warm
water and mild detergent.
Screws requiring loosening for future service and lamp
replacement should be greased for ease of maintenance. Use
silicone base grease only as oil base grease may damage
some components.
Luminaires with damaged or cracked glass shall be removed
from service immediately.
Continuously operated lamps should be turned off at least
once a week for 1 hour.
Lamp Replacement
The floodlight is to be wiped clean of all dust and debris prior
to disassembly.
Loosen the three wing nuts and pivot the fixing screws away
from the lamp carrier. Carefully withdraw the lamp carrier.
Replace the lamp only with a type and wattage suitable for the
control gear in use. Screw the lamp in to its full extent,
ensuring that it’s secure, but not over tightened.
Ensure gasket and joining surfaces are clean, return the lamp
carrier to its position and evenly tighten the wing nuts.
All manuals and user guides at all-guides.com
all-guides.com
EL-IM004.00 Page 2 of 2
Important – Safety
Before carrying out any servicing on this luminaire, ensure
that the mains supply is fully isolated. High voltages,
greater than mains voltage, can be present during
operation
LAMP TABLE
Type Wattage Lamp
M1000LE/BUH
MF1000LE/BUH
Metal
Halide 1000W M1000B X/U
MF1000B X/U
940W NH940LX
NH940FLX
High
Pressure
Sodium 1000W NH1000
NH1000F
Mercury 1000W HF1000PD
For further enquiries, please contact:
Eye Lighting
15 Industrial Ave, Wacol QLD Australia 4076
Tel: (617) 3335 3588 Fax: (617) 3335 3533
Email: [email protected].au
H572D / H570D
Max weight = 9.2 kg
Projected Area = 0.23 m2
H566D / H566S
Max weight = 8.8 kg
Projected Area = 0.27 m2
All manuals and user guides at all-guides.com

This manual suits for next models

4

Other Eye Lighting Floodlight manuals

Eye Lighting H573D Maintenance and service guide

Eye Lighting

Eye Lighting H573D Maintenance and service guide

Eye Lighting FHD Series User manual

Eye Lighting

Eye Lighting FHD Series User manual

Eye Lighting H373 Series Maintenance and service guide

Eye Lighting

Eye Lighting H373 Series Maintenance and service guide

Eye Lighting Turbo.Mini User manual

Eye Lighting

Eye Lighting Turbo.Mini User manual

Eye Lighting EYELITE PF*-L17-7**-W-***-*-DB Series Service manual

Eye Lighting

Eye Lighting EYELITE PF*-L17-7**-W-***-*-DB Series Service manual

Eye Lighting H572D Maintenance and service guide

Eye Lighting

Eye Lighting H572D Maintenance and service guide

Eye Lighting HOF201 Maintenance and service guide

Eye Lighting

Eye Lighting HOF201 Maintenance and service guide

Eye Lighting HOF103 Maintenance and service guide

Eye Lighting

Eye Lighting HOF103 Maintenance and service guide

Eye Lighting HOF401 Maintenance and service guide

Eye Lighting

Eye Lighting HOF401 Maintenance and service guide

Eye Lighting FGY-30L-408-W-UNV-DB Service manual

Eye Lighting

Eye Lighting FGY-30L-408-W-UNV-DB Service manual

Popular Floodlight manuals by other brands

BGS technic 85332 instruction manual

BGS technic

BGS technic 85332 instruction manual

Leviton JCC JC090001 installation guide

Leviton

Leviton JCC JC090001 installation guide

LF Utilitech MT125WUT quick start guide

LF

LF Utilitech MT125WUT quick start guide

ACR Electronics RCL-600A - SCHEMA REV A Product support manual

ACR Electronics

ACR Electronics RCL-600A - SCHEMA REV A Product support manual

UNILITE CRI-700R quick start guide

UNILITE

UNILITE CRI-700R quick start guide

YELLOWRIVER YR-668B-II Instruction book

YELLOWRIVER

YELLOWRIVER YR-668B-II Instruction book

Clarke CL6PIR Installation & operating instructions

Clarke

Clarke CL6PIR Installation & operating instructions

Clas Ohlson CO/TECH ECLC-HALO-0203D-UK quick start guide

Clas Ohlson

Clas Ohlson CO/TECH ECLC-HALO-0203D-UK quick start guide

BEGA 70 755 Instructions for use

BEGA

BEGA 70 755 Instructions for use

Skil LH5534-00 owner's manual

Skil

Skil LH5534-00 owner's manual

Philips HADCO WAMT14-H installation instructions

Philips

Philips HADCO WAMT14-H installation instructions

BOSS ILLUMINATION CASTLE II product manual

BOSS ILLUMINATION

BOSS ILLUMINATION CASTLE II product manual

Hoftronic 4404987 user manual

Hoftronic

Hoftronic 4404987 user manual

Ignition Co9Z LED Flood IP65 540W RGBW user manual

Ignition

Ignition Co9Z LED Flood IP65 540W RGBW user manual

ADJ 1223200091 user manual

ADJ

ADJ 1223200091 user manual

B.E.G. LUXOMAT AL5-RC-plus next Mounting instructions

B.E.G.

B.E.G. LUXOMAT AL5-RC-plus next Mounting instructions

PATHFINDER PsT 900 installation instructions

PATHFINDER

PATHFINDER PsT 900 installation instructions

OMEZ LIGHTING TitanBeam 2R user manual

OMEZ LIGHTING

OMEZ LIGHTING TitanBeam 2R user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.