manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Eye Lighting
  6. •
  7. Floodlight
  8. •
  9. Eye Lighting H566 Series Maintenance and service guide

Eye Lighting H566 Series Maintenance and service guide

This manual suits for next models

4

Other Eye Lighting Floodlight manuals

Eye Lighting EYELITE PF*-L17-7**-W-***-*-DB Series Service manual

Eye Lighting

Eye Lighting EYELITE PF*-L17-7**-W-***-*-DB Series Service manual

Eye Lighting HOF103 Maintenance and service guide

Eye Lighting

Eye Lighting HOF103 Maintenance and service guide

Eye Lighting H573D Maintenance and service guide

Eye Lighting

Eye Lighting H573D Maintenance and service guide

Eye Lighting FGY-30L-408-W-UNV-DB Service manual

Eye Lighting

Eye Lighting FGY-30L-408-W-UNV-DB Service manual

Eye Lighting H373 Series Maintenance and service guide

Eye Lighting

Eye Lighting H373 Series Maintenance and service guide

Eye Lighting HOF401 Maintenance and service guide

Eye Lighting

Eye Lighting HOF401 Maintenance and service guide

Eye Lighting H572D Maintenance and service guide

Eye Lighting

Eye Lighting H572D Maintenance and service guide

Eye Lighting FHD Series User manual

Eye Lighting

Eye Lighting FHD Series User manual

Eye Lighting Turbo.Mini User manual

Eye Lighting

Eye Lighting Turbo.Mini User manual

Eye Lighting HOF201 Maintenance and service guide

Eye Lighting

Eye Lighting HOF201 Maintenance and service guide

Popular Floodlight manuals by other brands

V-TAC VT-5192S installation instructions

V-TAC

V-TAC VT-5192S installation instructions

Major tech HLF30CW instruction manual

Major tech

Major tech HLF30CW instruction manual

EuroLite LED Cube user manual

EuroLite

EuroLite LED Cube user manual

EuroLite LED IP FL-100 SMD user manual

EuroLite

EuroLite LED IP FL-100 SMD user manual

Cooper Wheelock XB12 specification

Cooper Wheelock

Cooper Wheelock XB12 specification

Allen + Roth 17624-000 user manual

Allen + Roth

Allen + Roth 17624-000 user manual

ADJ 4 STAGE PAK User instructions

ADJ

ADJ 4 STAGE PAK User instructions

Cooper Lighting EGL91SW233 Specification sheet

Cooper Lighting

Cooper Lighting EGL91SW233 Specification sheet

Max 37496 instruction manual

Max

Max 37496 instruction manual

BEGA 85 143 Instructions for use

BEGA

BEGA 85 143 Instructions for use

Cameo CLPST64Q8W user manual

Cameo

Cameo CLPST64Q8W user manual

Beamz 151.226 user manual

Beamz

Beamz 151.226 user manual

EuroLite LED IP FL-8 user manual

EuroLite

EuroLite LED IP FL-8 user manual

Ledj PERFORMER 36 RGB user manual

Ledj

Ledj PERFORMER 36 RGB user manual

Perel ELS3 user manual

Perel

Perel ELS3 user manual

Perel ELS3WD user manual

Perel

Perel ELS3WD user manual

Xtricity 4-80053 instructions

Xtricity

Xtricity 4-80053 instructions

Stahl 6521/4 Series operating instructions

Stahl

Stahl 6521/4 Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Installation & Maintenance
H572D / H570D / H566D / H566S
CLASS I, IP65
EL-IM004.00 Page 1 of 2
Installation
The Eye Lighting H572D, H570D and H566 series’ are
floodlights for outdoor (permanent) use, designed to be
operated in conjunction with remote control gear appropriate
for the lamp type and wattage in use.
The floodlight is designed to be securely mounted on a suitably
solid horizontal surface using 2x M16 bolts.
Screw the lamp in to its full extent, ensuring that it’s secure,
but not over tightened.
Ensuring the gasket and joining surfaces are clean, secure the
lamp carrier to the main body by pivoting the three screws and
tightening the wing nuts evenly. Ensure the chain is attached.
Incoming supply cables from the control gear are terminated in
the termination box via the 20mm threaded entry.
To maintain the integrity of the enclosure’s protection against
dust and moisture ingress, cable glands or conduit fittings
rated at least IP65 must be used.
Check that the cable glands are tightened correctly.
Floodlights must be installed within the maximum
recommended distance to the control gear, as applicable to
the type used.
These instructions should be retained by the floodlight owner
for reference, and made available as necessary, to ensure
future maintenance is carried out correctly.
Aiming
Adjust the horizontal aiming of the floodlight by loosening the
anchor and swivel screws (not supplied) fixing the base to the
mounting surface. Using the markings on the base plate as a
guide, adjust to the required angle and tighten the screws.
Adjust the tilt by loosening the screws at the pivot point and
releasing the locking lever. Using the markings on the pivot
plate, adjust the floodlight to the required tilt angle and hold in
place by tightening the lever. Check the tilt angle is correct
and tighten the screws.
As an alternative to using the markings on the base and pivot
plates, the included aiming device may be used during this
process to aim at a specific point.
General Operation and Maintenance
Failed lamps are to be replaced promptly, or the circuit
isolated, to avoid possible control gear damage. Continual
operation on supply voltage above that nominated on the
control gear will reduce expected lamp and component life.
Clean excessive build up of foreign material from outer
surfaces of the body. Clean the lens as required with warm
water and mild detergent.
Screws requiring loosening for future service and lamp
replacement should be greased for ease of maintenance. Use
silicone base grease only as oil base grease may damage
some components.
Luminaires with damaged or cracked glass shall be removed
from service immediately.
Continuously operated lamps should be turned off at least
once a week for 1 hour.
Lamp Replacement
The floodlight is to be wiped clean of all dust and debris prior
to disassembly.
Loosen the three wing nuts and pivot the fixing screws away
from the lamp carrier. Carefully withdraw the lamp carrier.
Replace the lamp only with a type and wattage suitable for the
control gear in use. Screw the lamp in to its full extent,
ensuring that it’s secure, but not over tightened.
Ensure gasket and joining surfaces are clean, return the lamp
carrier to its position and evenly tighten the wing nuts.
All manuals and user guides at all-guides.com
all-guides.com
EL-IM004.00 Page 2 of 2
Important – Safety
Before carrying out any servicing on this luminaire, ensure
that the mains supply is fully isolated. High voltages,
greater than mains voltage, can be present during
operation
LAMP TABLE
Type Wattage Lamp
M1000LE/BUH
MF1000LE/BUH
Metal
Halide 1000W M1000B X/U
MF1000B X/U
940W NH940LX
NH940FLX
High
Pressure
Sodium 1000W NH1000
NH1000F
Mercury 1000W HF1000PD
For further enquiries, please contact:
Eye Lighting
15 Industrial Ave, Wacol QLD Australia 4076
Tel: (617) 3335 3588 Fax: (617) 3335 3533
Email: [email protected].au
H572D / H570D
Max weight = 9.2 kg
Projected Area = 0.23 m2
H566D / H566S
Max weight = 8.8 kg
Projected Area = 0.27 m2
All manuals and user guides at all-guides.com