Eyelite FD Series User manual

FD Series
Deluxe Floodlight
1
IMPORTANT SAFETY INSTRUCTIONS: This equipment is intended to be installed by qualified personnel. The installation
must be made in accordance with the current edition of the National Electric Code, and all applicable state and local building codes.
The final installation must be approved by the appropriate, qualified, electrical/building inspector(s). Improper Installation may
result in a risk of fire or electrical shock hazard. The instructions provided herein are made available for reference when installing
the PF Series Heavy Duty Floodlight. If any portion of these installation instructions is unclear then do not proceed with the
installation and contact an EYE Lighting Representative at 1-888-665-2677.
X= Mount Type (Y=Yoke or S= Slipfitter) XXX= UNV-120-277V or UNH-347/480V Y = (N-Non-Dimming or D-Dimmable)
READ AND FOLLOW ALL SAFETY INSTRUCTIONS BEFORE STARTING INSTALLATION
CAUTION
DANGER –RISK OF SHOCK- DISCONNECT POWER BEFORE INSTALLING or SERVICING LUMINAIRE.
Luminaire installation and servicing shall only be performed by qualified personnel.
This product uses an input 120-277v AC driver with universal wide range voltage.
Make sure the supply voltage is the same as the rated luminaire voltage.
Mounting surface must be specified to properly support the weight of the luminaire
Do not install in hazardous environment.
Do not operate in ambient temperatures above those indicated on the luminaire label.
Use UL listed wire rated for at least 90°C for supply connections.
Allow sufficient cool-down time prior to handling and/or servicing luminaire.
Failure to provide proper luminaire grounding may result in serious personal injury.
DO NOT OPPERATE
IF CRACKED OR BROKEN
40W & 78W YOKE 40W & 78W KNUCKLE 100W YOKE 100W SLIPFITTER 135W YOKE 135W SLIPFITTER
(sm) (lg) (sm) (lg)
Item
Base Model
Input Voltage
Power
Factor
Watt
Input Current
(@120 Vac)
Weight
A
FDX-L5-740-W-XXX-Y-DB
UNV = 120-277Vac
UNH = 347/480Vac
(via transformer)
≥0.98
40W
.337A
8.81 b /3.9 kg
B
FDX-L8-740-W-XXX-Y-DB
78W
.643A
17.62 lb/8 kg
C
FDX-L11-740-W-XXX-Y-DB
100W
.853A
26.43 lb/12 kg
D
FDX-L15-740-W-XXX-Y-DB
135W
1.135A
26.43 lb/12 kg
IF GLASS IS CRACKED OR BROKEN DO NOT OPPERATE - CONTACT MANUFACTURER

FLOODLIGHT
FIGURE 1
FIGURE 3
FIGURE 2
MOUNTING INSTRUCTIONS
FIXTURE IS SUITABLE FOR WET LOCATION
MOUNTING INSTRUCTIONS:
1. Mount the U-bracket to desired surface with (2) #5/16-18 screws
(provided) and make wire connections as needed
1. Remove sliptter cover and connect leads (see wiring diagram)
2. Push wires into sliptter and re-attach cover
3. Place slip-tter over 2 3/8 tennon and tighten with (4) set-screws
(provided)
4. To aim, loosen bolt on slip tter and set at desire rotation, then
tighten bolt securely
OPTIONAL COVER INSTALLATION: FIG. 3
1. PC cover, wire guard, and glare shield can be attached with (4)
8-32 screws to door frame
CAUTION: For proper weatherproof function all gaskets must be seated properly and all screws inserted and tightened rmly. Apply
weatherproof silicone sealant (NOT included) around the edge of the Wall Box and/or Junction Box. This is especially important with an uneven
wall surface. Silicone all plugs and unused conduit entries.
IMPORTANT: READ BEFORE REMOVING FIXTURE FROM CARTON. RETAIN FOR FUTURE REFERENCE.
This xture must be wired and installed in accordance with the NATIONAL ELECTRIAL CODE and all state and applicable local codes and
ordinances. These codes and ordinances supersede any and all instruction contained herein. Installation should be performed only by a
licensed and bonded electrician and a person familiar with the construction and operation of the product and the hazards involved in the
installation and operation of this product. Proper grounding is required for safety. Make certain power is OFF before installing or maintaining
xture. Failure to do so may increase the RISK OF PERSONAL INJURY, PROPERTY DAMAGE, FIRE, AND DEATH. The manufacturer takes no
responsibility for the product not installed under those guidelines and those contained in this document. See wiring diagram on back
SLIP-FITTER MOUNT INSTRUCTIONS: FIG.2
KNUCKLE-MOUNT INSTRUCTION: FIG2A
YOKE U-BRACKET INSTRUCTION: (FIG1)
1. Wire fixture in j-box (not provided)
2. Thread knuckle into j-box and secure at desired rotation
3. To aim flood vertically, loosen bolt on knuckle to desired position then re-tighten.
B
B
A

MOUNTING INSTRUCTIONS
ON-OFF WIRING METHOD:
Universal voltage driver permits operation at 120V through 277V, 50 or
60 Hz. Units ordered with (480V) sufx are 480V, 60Hz. For Non-Dimming,
follow the wiring directions as in FIG. 1
1. Connect the GROUND wire from xture to supply ground
2. Connect the white xture lead to the (-) COMMON supply lead
3. Connect the black xture lead to the (+) LINE supply lead
0-10V DIMMABLE WIRING METHOD:
Universal voltage driver permits operation at 120V through 277V, 50 or 60
Hz. For 0-10V Dimming, follow the wiring directions as in gure 2
1. Connect the GROUND wire from xture to supply ground
2. Connect the white xture lead to the (-) COMMON supply lead
3. Connect the black xture lead to the (+) LINE supply lead
4. Connect the purple xture lead to the (V+) DIM lead
5. Connect the gray xture lead to the (V-) DIM lead
5. Cap the yellow xture lead, if present. DO NOT connect
FIGURE 1
FIGURE 2
TROUBLESHOOTING:
1. Check that the line voltage at xture is correct
2. Is there voltage at the lamp xture wires? If there is no voltage, check
all connections
3. Ensure that the xture is grounded properly
LIGHTING
FIXTURE
(+) LINE
(-) COMMON
GROUND
BLACK
WHITE
GROUND
LIGHTING
FIXTURE
(+) LINE
(-) COMMON
(+)DIM V+
BLACK
WHITE
PURPLE
GROUND
GRAY
YELLOW
GROUND
(-)DIM V-
FLOODLIGHT
Do not install damaged luminaire equipment. Contact EYE Lighting, and return for inspection and repair.
Modifications to the device or changes of its design are not permitted.
The equipment must be operated according to the intended purpose in an undamaged condition.
EYE Lighting will not be responsible for claims arising from improper or careless installation or handling of luminaires.
**Retain a copy of these instructions**
EQS3771 05_2016
GR(E1
GR(E1
Table of contents
Popular Floodlight manuals by other brands

GARANT
GARANT 081445 3000 user guide

Chauvet
Chauvet Swarm 4 user manual

Good Earth Lighting
Good Earth Lighting SE1091-BP2-01LF0-G manual

Golight
Golight Stryker Instruction guide

Beamz professional
Beamz professional PAR 64 36x3W RGBW LED's IR DMX instruction manual

Thorn
Thorn CHAMPION installation instructions