FLOODLIGHT
FIGURE 1
FIGURE 3
FIGURE 2
MOUNTING INSTRUCTIONS
FIXTURE IS SUITABLE FOR WET LOCATION
MOUNTING INSTRUCTIONS:
1. Mount the U-bracket to desired surface with (2) #5/16-18 screws
(provided) and make wire connections as needed
1. Remove sliptter cover and connect leads (see wiring diagram)
2. Push wires into sliptter and re-attach cover
3. Place slip-tter over 2 3/8 tennon and tighten with (4) set-screws
(provided)
4. To aim, loosen bolt on slip tter and set at desire rotation, then
tighten bolt securely
OPTIONAL COVER INSTALLATION: FIG. 3
1. PC cover, wire guard, and glare shield can be attached with (4)
8-32 screws to door frame
CAUTION: For proper weatherproof function all gaskets must be seated properly and all screws inserted and tightened rmly. Apply
weatherproof silicone sealant (NOT included) around the edge of the Wall Box and/or Junction Box. This is especially important with an uneven
wall surface. Silicone all plugs and unused conduit entries.
IMPORTANT: READ BEFORE REMOVING FIXTURE FROM CARTON. RETAIN FOR FUTURE REFERENCE.
This xture must be wired and installed in accordance with the NATIONAL ELECTRIAL CODE and all state and applicable local codes and
ordinances. These codes and ordinances supersede any and all instruction contained herein. Installation should be performed only by a
licensed and bonded electrician and a person familiar with the construction and operation of the product and the hazards involved in the
installation and operation of this product. Proper grounding is required for safety. Make certain power is OFF before installing or maintaining
xture. Failure to do so may increase the RISK OF PERSONAL INJURY, PROPERTY DAMAGE, FIRE, AND DEATH. The manufacturer takes no
responsibility for the product not installed under those guidelines and those contained in this document. See wiring diagram on back
SLIP-FITTER MOUNT INSTRUCTIONS: FIG.2