Factor IR-KIT-36K User manual

IR-KIT-36/56K Repeater System
Thank you for purchasing the Factor Electronics IR-KIT-36/56K which can be
used to controlling up to 8 IR-controllable A/V devices behind using your
existing IR remote controls.
SYSTEM CONTENTS:
(1) IR-CONN-BLK
IR CONNECTION BOX …………….…………………………………………………….1PC
(2)IR-REP-36/56K
Dual-band IR RECEIVER……………………………………………………………..…1PC
(3) IR-2-FLASH
DUAL IR blinking emitter …………………………………..…………………….……2PCS
(4) IR-PWR-12V/500
12V/500mA switching power ……….……………….…….…………………….….1PC
INSTALLATION DIAGRAM & MOUNTING INSTRUCTIONS:
MOUNTING INSTRUCTION
(Refer to the installation diagram):
Mount the IR-CONN-BLK IR connecting box behind AV devices and near an AC
outlet.
Connect the IR receiver IR-REP-36/56K to the IR-CONN-BLK connecting box.
Position the IR receivers in a location which is “line of sight” to your IR remote
controls.
Plug the IR-2-FLASH emitters into the IR-CONN-BLK connecting box and
attach the emitter directly on top of the component’s IR sensors.
The IR-PWR-12V/500 power DC adaptor plugs into a voltage compliant AC
outlet and connects to the “POWER”receptacle of the IR-CONN-BLK
connecting box. Make sure the POWER LED indicator is “ON green” to confirm
The unit is ready for operation.
INSTALLATION DIAGRAM
CD PLAYER 1 CD PLAYER 2 DVD PLAYER1
L
R
123
IR RECEIVER
SPEAKERS
TERMINAL BLOCK
IR
V+
G
RPT
PWS
1
2
4
REMOTE
DC 12V
Power Am plifier
V+ :With SOLID STRIPE
MARKING in GREY
G:No any marking
IR:With DASH
MARKING in GREY
V+ :With SOLID STRIPE
MARKINGin GREY
G:No any marking
IR:With DASH
MARKING in GREY
BACK VIEW
FOR THE CODING & DEFINITION
EMITTER_Dual
3
3
EMITTER_Dual
IR WINDOW
NOTE:
If a power supply is not connected to the status power receptacle on the
IR-CONN-BLK connecting box, the status LED’s will not function. The status
power adaptor is not included in this kit. However the IR will function.

(1) IR-CONN-BLK IR CONNECTING BOX
Features and Characteristics
Four emitter output connections
Status power receptacle with LED indicator
Power receptacle with LED indicator
Removable connector for quick connections
Includes mounting/adhesive for wall mounting
Installation
Power:
Connect a 12V DC 500mA power supply to the power jack.
2.1mm + Tip –sleeve. The green LED will be illuminated when powered. This will
power all of the IR components connected to the system.
Status Power:
12VDC 200mA 2.1mm + tip –sleeve. Connecting a power supply
to this connection will power the status connection. The green LED will
illuminate when powered. This can be from a 12 volt trigger output or from a wall
type power supply plugged into a switched outlet of a stereo receiver.
System Connection:
Connect the IR repeaters to the detachable connector
printed V+ (12VDC), G(Ground), and IR (Signal).
Emitter Outputs:
Choosing compatible parts such as IR-1-FLASH or IR-2-FLASH (single or dual IR
emitter), connect up to 4 emitters to the emitter jacks marked 1-4. Place the
emitters directly onto the source equipment’s IR sensors (up to 8 units).
Mounting:
Mount /adhere IR-CONN-BLK near the source equipment that the emitters are
attached to.
(2)IR-REP-36/56K IR RECEIVER
The dual-band 38 KHz & 56 KHz IR employs a DSP circuit that is designed
specifically for installation near Plasma, CFL or EMI devises and eliminates
inferences.
Specifications & Features:
Carrier Frequency: 38K + 2K and 56K + 2K Hz.
The standard version of 3 –conductor color-coded cable leads accommodating
the connections of V+, G & IR with a DSP circuit is designed to block plasma,
EMI noise sources.
2M of cable length from main module to bare lead are provided
Typical Control Range: 38 KHz up to 50 feet and 56 KHz up to 30 feet indoor
on axis, depending on remote strength and ambient interference and 15 to 20
feet in direct sunlight.
Reception Angle: Up to 20 foot distance for + / –45 degree off axis.
LED display:
Activity LED: When the IR signal is received the from remote controller the
Blue LED lights to confirm the IR signal completed the circuit with a
terminator or an Emitter.
IR Lens: rejects visible light interference.
Preinstalled with the black frame 1 extra pc of each white and silver
frames have been included to match the surround of the TV or display.
Dimension: 63(L) x 11(W) x 10(H) mm
Power Requirement: DC 12V, (500~1200mA), Using a regulated adaptor is
recommended
CODE COMPATIBILITY:
38KHz (BR) - CODE 56KHz(DX) - CODE
NEC Code
◆
NEC Code
◆◆
RC5 Code
◆
RC5 Code
◆◆
RC6 Code
◆
RC6 Code
◆◆
RCMM Code
◆
RCMM Code
◆◆
r-step code
◆
r-step code
◆◆
RCS-80 Code
◆
RCS-80 Code
◆◆
R-2000 Code
◆
R-2000 Code
◆◆
RCA Code
◆
RCA Code
◆◆
Sharp Code
◆
Sharp Code
◆◆
Sony 12-bit Code
◆
Sony 12-bit Code
◆◆
Sony 15-bit Code
◆
Sony 15-bit Code
◆◆
Sony 20-bit Code
◆
Sony 20-bit Code
◆◆
Zenith Code
◆
Zenith Code
◆◆
High Data Rate Code
◆
High Data Rate Code
◆◆
XMP code
◆
Disturbance Suppression
◆◆
Grundig code
◆
XMP code
◆◆
NOTE:
◆
Suitable for this IR code
◆◆
Best for this application
(3) IR-2-FLASH DUAL BLINKING EMITTER
SPECIFICATION & FEATURES:
Oval shape & ultra-compact size
Infrared is built in a transparent housing
Includes 10’cable length / With 3.5mm mono standard plug
Includes self-adhesive tape for quick and easy mounting to any hard, clean &
dry surface / Status indicator
NOTE:
Make sure mounting surface is clean and dry for best results.
Connections of IR emitters directly to power supply’s or battery’s is not
recommended!

This manual suits for next models