Factron QHC24MR User manual

QHC24MR 24Kw Heater Controller
3 channel (Receiver)
Remote & Manual operation
Quick start gui e
Three phase 415v / Three zone / Remote & Manual / Soft star

Quick Start for QHC24MR 24Kw
Heater Controller with Soft start
Remote & Manual Operation.
Service hatch
Isolation
switch 40A
O/P MCBs
40A Type C
Power
control ial
5 settings
Manual &
Remote
Power ON
in icator
Over Temp
in icators Front panel
QHVCR remote Master Controller
Antenna
Power
Power control ials
Blue, Re & Yellow Device ON / Stan by In icator
ON / Stan by Switch
Page 1

1) Start by removing the service hatch. Remove the 4 fixing screws, at the top and in the corners. There
is a Din Rail revealed once the service hatch has been removed.
) Use the cable grommets to bring the cables into and out of the controller base .
3) Connect the Mains IN as follows, Neutral blue wire to terminal #1 – Neutral IN, Live brown wire to
terminal # – L1 IN, Live black wire to terminal #3 – L2 IN, Live grey wire to terminal #4 – L3 IN.
4) There are two methods on how to connect the Infrared Heaters to the controller. a)
Connect the heater or heaters Live to O/P1 terminal #5 switche L1, the O/P has a maximum load
capacity of 8Kw or 40amps. O/P1 can also be referred to as Zone 1. Connect the heater Neutrals to
Neutral Out terminals #8 – 13. The heater Earth is connected to the Earth terminal #14. The remaining
heaters should be distributed across the remaining two outputs O/P & O/P3. Please ensure that the
loa is balance across the output terminals #5 – 7. Do not excee the maximum loa capacity per
output. b) Connect to an
external distribution box. Connect O/P1 to terminals marked 1, O/P to terminals marked 2 and O/P3 to
terminals marked 3. Connect the Neutral OUT to the blue terminals marked N. Connect the Earth to the
green/yellow Earth terminals. Then connect the heaters to the other side of the terminals to the
appropriate connections. Live connections to terminals 1,2&3. Neutral connections to blue terminals N
and Earth connections to the Earth terminals.
5) When all connections are complete and connected correctly, check once again that the wiring is correct as
per 3) & 4). Then replace the service hatch cover and tighten the fixing screws.
6) Turn ON or reconnect the Main Power to the controller. The red neon lamp on the front panel will
illuminate to indicate that the unit is LIVE.
7) There are auxiliary devices such as mains operated PIR motion detectors & timer (lag) switches. These
can be connected to terminals #15 – 17. External push button switches which are voltage clean or free
can be connected to terminals #18 – 0.
8) Remote operation ensure the Power control dial is in position R. Follow the instructions in page 3 for
QHVCR remote Master Controller .
9) Manual operation move the position of the dial through positions M, 1, 2, 3 & 4.
M = 0%, 1 = 33%, 2 = 50%, 3 = 66%, 4 = 100%
Power control Dial
Settings R, M, 1 to 4
Antenna
Over temperature
indicators
Power ON indicator
IMPORTANT
If wire links or external push button switches
are not fitte the unit will not operate.
Remove wire links white, yellow & red.
Page

QHC24MR 24Kw Heater Controller Din Rail & connections
Distribution Box P/No. QHDB-18 4
Terminals 1 – O/P1, Terminals 2 – O/P2, Terminals 3 – O/P3
Blue terminals N – N out, Green/Yellow terminals – Earth
Important ! Only a qualifie electrician shoul install this evice.
Page 3

QHVCR remote Master Controller (transmitter)
1) There are three control dials Blue, Yellow & Red one for each zone. The QHCxxMR units are
preset to operate in one of these zones. The QHCxxMR unit once preset will only operate in that
designated zone. The factory setting is 1, this will be the Blue control dial.
) Turn ON the QHVCR unit by pressing the ON/Standby button on the front panel. The Led
indicator will flash orange – green – orange – green and remain Green to indicate that the unit is
ready.
3) The QHCxxMR unit is preset as a Blue zone (1). Turn the Blue control dial to position 2. The
heaters connected to the QHC06MR units will come ON at the minimum setting 33%. Continue to
turn the Blue control dial through position 3 to 5 until you reach the desired setting. Settings are 1 =
0%, 2 = 33%, 3 = 50%, 4 = 66% & 5 = 100%.
4) QHCxxMR units which are preset to Yellow & Red zones are controlled by the Yellow & Red
control knobs respectively and will operate as above in 10).
5) The QHVCR unit is powered by 3 x AAA battery's. So, the unit will automatically go into standby
mode if the unit is inactive for more than 30 seconds. When the unit goes into standby mode all the
QHCxxMR units will remain unchanged at the settings they were set at. The heaters will remain ON.
6) To change a setting just press the ON/Standby button and proceed as described in 9) & 10).
However, while the QHVCR unit is ON, you can turn OFF all the heaters by pressing the ON/Standby
button. This is indicated by the Led indicator flashing Red.
7) The previous settings will be remembered and will be restored when you press the ON/Stand by
button again.
Please note: The QHVCR remote Master Controller can control any number of
QHCxxMR controllers as long as they are within range, up to 100 meters *
(see specification sheet for the QHVCR unit).
The QHVCR should be wall mounted.
Page 4

Pairing (programming) evices
QHVCR & QHC24MR
Pairing (programming) evices QHVCR (transmitter) an QHC24MR (receivers).
1) The Left Hand Side rotary switches (TEN) on both boards must be set the same.
The LHS switch (TEN) is used to set the RF frequency the setting must match on both
boards. There are 10 possible frequencies that can be selected 0-9. If the settings on the LHS
switch (TEN) do not match the devices will fail to operate.
Designating the transmitter and receiver. Both the left rotary switches are set at 0,
this ensures that the transmitter marked 0 will communicate with the receiver marked 0.
Setting the left rotary switch to 1, so the transmitter marked 1 will communicate with a
receiver also marked 1.
If the transmitter and receiver are not paired correctly they will not communicate and
therefore will not operate; transmitter marked 0 will not communicate with a
receiver marked 1.
Remember a transmitter can be set at any number between 0-9 & the receiver must be
matched correctly.
) The Right Hand Side rotary switches (UNIT) are for setting the devise to operate in a set
zone. There are 3 possible zones that the controller can be set to. The RHS switch (UNIT)
should be set to 1, or 3.
Blue Zone 1 operation set RHS switch (UNIT) to 1
Yellow Zone operation set RHS switch (UNIT) to 2
Re Zone 3 operation set RHS switch (UNIT) to 3
Page 5

Page 6

CE RoHS Technical Data
Supply voltage : Three phase 415V AC 50/60 Hz All O/P's with Soft start
Max. Loa capacity: 24 Kilo Watts * (Loa must be balance across all 3 outputs max 8Kw each)
Over Temperature Protection: On each O/P - Le in icators 1,2 & 3
Mains I/P : Neutral (Blue) terminal #1
Live 1 (Brown) terminal #2
Live 2 (Black) terminal #3
Live 3 (Grey) terminal #4
Mains O/P : Switche Live 1 (Brown) terminal #5
Soft start Switche Live 2 (Black) terminal #6
Switche Live 3 (Grey) terminal #7
Neutral return out (Blue) terminal #8-13
Earth out (Green/Yellow) terminal #14
PIR I/P : Live trigger input Zone 1 terminal #15
Auxiliary Live trigger input Zone 2 terminal #16
Device Live trigger input Zone 3 terminal #17
Ext. Sw. I/P : Ext. SW1 Zone 1 terminal #18 a+b
Auxiliary Ext. SW2 Zone 2 terminal #19 a+b
Device Ext. SW3 Zone 3 terminal #20 a+b
QHVC-S I/P : 0V terminal #21
Auxiliary Zone 1 terminal #22
Device Zone 2 terminal #23
Optional Zone 3 terminal #24
5V terminal #25
IP Rating: IP53
Dimensions : 350mm x 330mm x 150mm Note : Terminal connections are the same
Weights : QHC18M – 10 Kg for both the QHC24M
QHC24M – 12 Kg & QHC24MR controllers.
Tel. 00 353 1 8352718 Email: [email protected] dave@factron.ie
Website: .factron.ie
Factron Ltd. Unit 12 Ashbourne Ind. Park, Ashbourne, Co.Meath , A84 HY 4, Ireland
Other Factron Controllers manuals
Popular Controllers manuals by other brands

Emerson
Emerson YARWAY Series Instruction, Operation and Maintenance Manual

PRECISION DIGITAL
PRECISION DIGITAL PROVU PD6210 instruction manual

Honeywell
Honeywell Pressuretrol L404 Series manual

Scotts
Scotts Gro 7 Zone Controller quick start guide

Elsner
Elsner KNX eTR 208 Light/Sunblind Installation and adjustment

socorex
socorex PROFILLER 435 operating instructions