F&F KK-01B User manual

User guide
Video door phones
RoHS

Table of contents
2
Description of the door stations .................................................. 3
Description of the symbols in the diagrams (door stations) .......... 7
Description of monitors .............................................................. 12
Description of the symbols in the diagrams (monitors) ................ 21
Installation ................................................................................ 26
27
Wiring diagram of CCTV camera ................................................ 41
Operating the video door phone 42
Warranty card ..................................................................... 45
Programming of the door station with combination lock ............... 8
Programming of the door station with card reader ....................... 10
Operating the monitor with memory............................................ 23
Wiring diagram ..........................................................................
..................................................

Dimensions: 55×135×39 mm
KK-01B, KK-01G, KK-01S
Description of the door stations
1: audio-red
2: ground-blue
3: camera power supply
from the monitor-
4: video-white
5: bolt-black
6: bolt-black
yellow
Bolt
Monitor
6
3
Volume
control
Dimensions: 75×182×60 mm
KK-03
1: audio-red
2: ground-blue
3: camera power supply from the monitor-yellow
4: video-white
5: additional bolt release button
6: DC12-14,5V power supply* (-)/bolt (-) /bolt switch
7:
do not connect
* power supply FF: ZV-14
access block for users 10-20 and 36-40
8: bolt (+)
9: DC12-14,5V power supply* (+)
10:
DC12V
power supply
_+
Monitor
Volume
control
56789 10
red
blue
yellow
white
Bolt
release
button
EXIT
2
3
4
5
6
7
1
10
2
3
4
5
6
7
11
1

KK-04
Dimensions: 150×203×55 mm
Installation box dimensions:
130×183×50 mm
1: audio-red
2: ground-blue
3: camera power supply
from the monitor-yellow
4: video-white
5: bolt-black
6: bolt-black
Bolt
Monitor
6
Volume
control
Dimensions: 120×250×51 mm
Installation box dimensions:
110×240×46 mm
KK-05
1: audio-red
2: ground-blue
3: camera power supply
from the monitor-yellow
4: video-white
5:
: DC12-14,5V power supply* (-) black
* power supply FF: ZV-14
bolt
6: bolt
8: DC12-14,5V power supply* (+) red
9
Bolt
Monitor
6
Volume
control
Power
supply
89
Bolt release
button
EXIT
Access block button
for users 10-20
and 36-40
4
2
3
4
5
6
7
2
3
4
5
6
7
10
11
8

KK-08
Dimensions: 120×250×51 mm
Installation box dimensions:
110×240×46 mm
Please note!
Remove the jumper J3
in all monitors and uniphones
Access block button
for users 10-20 and 36-40
Bolt
Monitor 2
6
Volume
control
Power
supply
8
9
Bolt release
button
EXIT
Monitor 1
1: audio-red
2: ground-blue
3: camera power supply
from the monitor-yellow
4: video-white
5:
: DC12-14,5V power supply* (-) black
* power supply FF: ZV-14
bolt
6: bolt
8: DC12-14,5V power supply* (+) red
9
KK-08K
Dimensions: 120×250×51 mm
Installation box dimensions:
110×240×46 mm
Please note!
Remove the jumper J3
in all monitors and uniphones
1: audio-red
2: ground-blue
3: camera power supply
from the monitor-yellow
4: video-white
5: bolt
: DC12-14,5V power supply* (-) black
* power supply FF: ZV-14
6: bolt
8: DC12-14,5V power supply* (+) red
9
Access block button
for users 10-20 and 36-40
Bolt
Monitor 2
6
Volume
control
Power
supply
8
9
Bolt release
button
EXIT
Monitor 1
5
3
4
5
7
6
8
10
11
2
3
4
5
7
10
12
2
6
8

KK-09
Dimensions: 120×250×51 mm
Installation box dimensions:
110×240×46 mm
Please note!
Remove jumper J3
in all monitors and uniphones
Bolt
6
Volume
control
Power
supply
89
Monitors
1: audio-red
2: ground-blue
3: camera power supply
from the monitor-yellow
4: video-white
5:
: DC12-14,5V * (-) black
* FF: ZV-14
bolt
6: bolt
8: DC12-14,5V power supply* (+) red
9 power supply
power supply
6
2
3
4
5
6
7
8

7
Technical data
Main power supply,
bolt, keypad or RFID
power supply
DC 12V from monitor KK-01
ZV-14 power supply KK-03
ZV-14 power supply KK-05÷KK-09
Power consumption during operation 1,5 W
Camera angle about 70° (adjustable)
Operating temperature range
Minimum illumination 0,05 Lux
Converter 1/3 CCD
IP 55
Backlight
LED
-25C ÷ +55C
Protection cowl
LED
Camera
Speaker
Call button
Microphone
Camera mounting screw
Signboard for name
Keyboard
Cable ducting
LED indicating operating status of the keypad
Card reader
Function descriptionNo.
Description of the symbols
in the diagrams (door stations)
1
2
3
4
5
6
7
8
9
10
11
12

1. Programming user access code:
a) press , you will hear two short beeps:
b) enter the master code ( – factory settings), you will hear
three short beeps, red LED will begin to flash;
c) enter user number from 01 to 40, you will hear two short beeps (users
with numbers from 31 to 40 can open the door for an indefinite period of
time - the doors remain open until re-entering the code);
d) enter a 4-digit user code, you will hear 3 short beeps;
e) return to step 3 to set more users or press to complete the
programming; after pressing you will hear five beeps.
2. Deleting user code:
a) press , you will hear two short beeps;
b) enter the administrator code, you will hear three short beeps,
red LED will begin to flash;
c) enter user number from 01 to 40 that you want to delete, you will
hear two short beeps;
d) press , you will hear three short beeps;
e) return to step 3 in case of removing more user codes or press to
complete the removal, after pressing you will hear five short
beeps.
3. Programming the lock opening time:
a) press , you will hear two short beeps;
b) enter the administrator code, you will hear three short beeps,
red LED will begin to flash;
c) enter , you will hear two short beeps;
d) enter the required opening time from 01 to 99 seconds (2 digits) you
will hear three short beeps;
e) press to complete programming, you will hear five short beeps.
4. Changing the administrator code:
(factory set master code is: 1234)
a) disconnect the power supply;
b) press and hold the button, connect the power (while holding
the button pressed), door station will generate a long, continuous
sound;
c) when the sound is over, please release the button , you will
hear one short beep and a red LED will flash;
d) enter new, four-digit administrator code.
1234
0
0
Programming of the door station
with combination lock
8

9
5. Opening the door with a code
a) enter a 4-digit user code, the red LED lights, the door will open.
6. Reset all user codes (except the administrator code)
a) press , you will hear two short beeps;
b) enter administrator code, you will hear three short beeps, red LED will begin
to flash;
c) press , you will hear two short beeps, the LED flashes;
d) press , you will hear two short beeps, the LED flashes;
e) press successively six times, you will hear one short beep, the LED
flashes;
f) press , you will hear five short beeps, the LED goes out, the system reset.

1. Adding a user card with the MASTER card:
a) Bring the MASTER card close to the reader, you will hear one short and one
long beep;
b) Then enter the last 6 digits of the card number or move it closer to the
reader, saving your card in the memory will be confirmed with long beep;
c) If you want to add more cards, repeat step 2 as many times as needed;
d) To exit the card adding mode, bring the MASTER card close to the
reader, you will hear three short beeps – the device is ready for
operation.
2. Enter programming mode:
PLEASE NOTE!
The DH 12-R remote control is necessary for programming the door station.
The remote control is not included in the door station package.
a) to enter the programming mode, point the remote control at LED located on the
door station and enter the factory code , you will hear a tone
confirming the change of the operating mode, and the LED located on the
station will change its color from red to orange;
b) exit the programming mode by pressing the , the tone and LED color change
to red will confirm a return to operating mode.
3. Adding user card:
a) Enter the programming mode (see point 1);
b) Press number on the remote control, you will hear a long beep;
c) Enter the last 6 digits of the card number or bring it closer to the
reader – short beep means the card was accepted, the next long
beep confirms card saving;
d) If you want to add more cards, repeat step 3 as many times as needed;
e) If you bring closer a card that is already registered, you will hear four short
beeps;
f) To exit the user card adding mode, press .
4. Removing the card:
a) To remove the registered card the device should be
put in to a programming mode (see point 1);
b) Press number on the remote control, you will hear a long beep;
c) Enter the last 6 digits of the card number you want to delete or bring it
closer to the reader. You will hear one short and one long beep confirming
the removal of the card;
To exit the user card adding mode, press
d) .
2
1
Programming of the door station
with card reader
10
4567

5. Removing all cards:
1) Enter the programming mode (see point 1);
2) Press number on the remote control, you will hear a long beep.
Wait for the audio signal to end, it will confirm the deletion of all cards from
the door station memory;
3) Return to operation after pressing .
6. Administrator code change:
1) Enter the programming mode (see point 1);
2) Press number on the remote control, you will hear a long beep;
3) Enter the new four-digit code and confirm by pressing , re-enter the
new code and confirm it by pressing . You will hear a long beep
confirming the change of the code administrator;
4) Return to operation after pressing .
7. Programming the MASTER card:
1) Enter the programming mode (see point 1);
2) Press number on the remote control, you will hear a long beep and the LED
will change its color to orange;
3) Enter the last 6 digits of the card number that is to be the MASTER card or bring it
closer to the reader, you will hear one short and one long beep confirming your card
has been saved in the memory;
4) To exit card adding mode, press , you will hear a long beep and the LED
will change its color to red – the device is ready to work;
5) MASTER cards cannot be removed, only new card can be programmed in place
of damaged or lost card.
8. Restoring the forgotten administrator code:
1) Turn off power supply for at least 10 seconds;
2) Connect the power supply and when the LED is flashing (six times),
press the on the remote control, you will hear the beep confirming
the restoration of the MASTER code to default value: 4567.
9. Programming the lock opening time:
1) Enter the programming mode (see point 1);
2) Press number on the remote control, you will hear long beep;
3) Enter the desired time of electric lock opening from 01 to 99 seconds
(two-digits);
4) You will hear a long beep confirming the change in lock time opening;
5) Exit the programming mode by pressing .
10. Opening the lock with the card:
1) Bring the card to the reader at a distance of 5 cm;
2) Opening the lock is indicated by the green LED on the door station.
07
8
99
11
4

12
Description of monitors
Dimensions: 241×161×23 mm
MK-03G (black), MK-03W (white)
1) audio-red
2) ground-blue
3) camera power supply-yellow
4) video-white
8) (+) of power supply-red
9) (-) of power supply-black
10) connection to the control input of the door
automaton, it is a closing contact
of the NO relay (dry contact).
Do not connect voltages greater than 24 V,
the current should not exceed 150 mA.
J1, J2, J3 jumper configuration:
J1: switching on or off the chime in the door station
a) jumper put on – audible chime
b) jumper removed – chime off
J2: fit the cable in the video line
a) jumper put on – coaxial cable, if the system has more than one monitor installed,
leave only the jumper in the last monitor and remove it in all the other monitors
b) jumper removed – other cable
J3: switching on or off the backlight of the call button and the signboard in KK-04 door
station:
a) jumper put on – backlight on
b) jumper removed – backlight off
In case of door stations other than KK-04, the jumper must be removed.
10 10 1
2
3
4
1
2
3
4
8
9
J3
J2
J1
POW
connection
of the door
station 2
connection
of the DC 14.5 V
power supply
connection
to the control input
of the door automaton
10 10 12
3
4
12
3
4
89
J3
J2
J1
POW
connection
of the door
station 1
1
2345
15
14
8 9
10
11

13
MK-04B, MK-04W
Dimensions: 245×160×18 mm
J1, J2, J3 jumper configuration:
J1: switching on or off the chime in the door station
a) jumper put on – audible chime
b) jumper removed – chime off
J2: fit the cable in the video line
a) jumper put on – coaxial cable, if the system has more than one monitor installed,
leave only the jumper in the last monitor and remove it in all the other monitors
b) jumper removed – other cable
J3: switching on or off the backlight of the call button and the signboard in KK-04
door station:
a) jumper put on – backlight on
b) jumper removed – backlight off
In case of door stations other than KK-04, the jumper must be removed.
1) audio-red
2) ground-blue
3) camera power supply-yellow
4) video-white
8) (+) of power supply-red
9) (-) of power supply-black
10) connection to the control input of the door
automaton, it is a closing contact
of the NO relay (dry contact).
Do not connect voltages greater than 24 V,
the current should not exceed 150 mA.
- jumper open
- jumper closed
connection
of the DC 14.5 V
power supply
connection
to the control input
of the door automaton
10 10
12
3
4
1234
89
J3
J2
J1
POW
connection
of the door
station 2
connection
of the door
station 1
6
7
1
2
3
4
5
14
8 9 10

14
J1, J2, J3 jumper configuration:
J1: switching on or off the chime in the door station
a) jumper put on – audible chime
b) jumper removed – chime off
J2: fit the cable in the video line
a) jumper put on – coaxial cable, if the system has more than one monitor installed,
leave only the jumper in the last monitor and remove it in all the other monitors
b) jumper removed – other cable
J3: switching on or off the backlight of the call button and the signboard in KK-04
door station:
a) jumper put on – backlight on
b) jumper removed – backlight off
In case of door stations other than KK-04, the jumper must be removed.
MK-06B
1) audio-red
2) ground-blue
3) camera power supply-yellow
4) video-white
8) (+) of power supply-red
9) (-) of power supply-black
10) connection to the control input of the door
automaton, it is a closing contact
of the NO relay (dry contact).
Do not connect voltages greater than 24 V,
the current should not exceed 150 mA.
Dimensions: 282×135×23 mm
Door automaton control
connection
of the DC 14.5 V
power supply
connection
to the control input
of the door automaton
1010
1
2
3
4
12
3
4
89
J3
J2
J1 POW
connection
of the door
station 2
connection
of the door
station 1
12
2
3
4
5
6
11 89
10

15
J1, J2, J3 jumper configuration:
J1: switching on or off the chime in the door station
a) jumper put on – audible chime
b) jumper removed – chime off
J2: fit the cable in the video line depending on the number of monitors in the system:
a) 1 monitor: jumper put on + resistor
on the cables between video and ground
b) 2 monitors: jumpers in two monitors put on
c) 3 monitors: jumper removed in first monitor,
put on in monitors 2 and 3
d) 4 monitors: jumper removed in first
and second monitor, put on in 3 and 4
J3: switching on or off the backlight of the call button
and the signboard in KK-04 door station:
a) jumper put on – backlight on
b) jumper removed – backlight off
In case of door stations other than KK-04, the jumper must be removed.
1) audio-red
2) ground-blue
3) camera power supply-yellow
4) video-white
8) (+) of power supply-red
9) (-) of power supply-black
10) connection to the control input of the door
automaton, it is a closing contact
of the NO relay (dry contact).
Do not connect voltages greater than 24 V,
the current should not exceed 150 mA.
Dimensions: 282×135×23 mm
MK-06WF
Cursors
Menu exit
Menu
Door automaton control
connection
of the DC 14.5 V
power supply
connection
to the control input
of the door automaton
1010
1
2
3
4
12
3
4
89
J3
J2
J1 POW
connection
of the door
station 2
connection
of the door
station 1
white
yellow
blue
red
Resistor
50÷120 Ω
Camera
2
3
4
5
6
12
11 8

16
MK-07WB
Dimensions: 240×170×23 mm
1) audio-red
2) ground-blue
3) camera power supply-yellow
4) video-white
8) (+) of power supply-red
9) (-) of power supply-black
10) connection to the control input of the door
automaton, it is a closing contact
of the NO relay (dry contact).
Do not connect voltages greater than 24 V,
the current should not exceed 150 mA.
J1, J2, J3 jumper configuration:
J1: switching on or off the chime in the door station
a) jumper put on – audible chime
b) jumper removed – chime off
J2: fit the cable in the video line
a) jumper put on – coaxial cable, if the system has more than one monitor installed,
leave only the jumper in the last monitor and remove it in all the other monitors
b) jumper removed – other cable
J3: switching on or off the backlight of the call button and the signboard in KK-04
door station:
a) jumper put on – backlight on
b) jumper removed – backlight off
In case of door stations other than KK-04, the jumper must be removed.
1
2
3
4
1
2
3
4
8
9
J3
J2
J1
POW
connection
of the DC 14.5 V
power supply
12
3
4
12
3
4
89
J3
J2
J1
POW
connection
of the door
station 2
connection
of the door
station 1
8910
14
1
2
3
4
5

17
MK-08F
Dimensions: 241×161×23 mm
Menu
Menu exit
Navigation
cursors
1) audio-red
2) ground-blue
3) camera power supply-yellow
4) video-white
8) (+) of power supply-red
9) (-) of power supply-black
10) connection to the control input
of the door automaton, it is a closing
contact of the NO relay (dry contact).
Do not connect voltages greater than 24 V,
the current should not exceed 150 mA.
J1, J2, J3 jumper configuration:
J1: switching on or off the chime in the door station
a) jumper put on – audible chime
b) jumper removed – chime off
J2: fit the cable in the video line depending on the number of monitors in the system:
a) 1 monitor: jumper put on + resistor
on the cables between video and ground
b) 2 monitors: jumpers in two monitors put on
c) 3 monitors: jumper removed in first monitor,
put on in monitors 2 and 3
d) 4 monitors: jumper removed in first
and second monitor, put on in 3 and 4
J3: switching on or off the backlight of the call button
and the signboard in KK-04 door station:
a) jumper put on – backlight on
b) jumper removed – backlight off
In case of door stations other than KK-04, the jumper must be removed.
connection
of the DC 14.5 V
power supply
connection
to the control input
of the door automaton
10 10 12
3
4
12
3
4
89
J3
J2
J1
POW
10 10 1
2
3
4
1
2
3
4
8
9
J3
J2
J1
POW
connection
of the door
station 2
connection
of the door
station 1
white
yellow
blue
red
Resistor
50÷120 Ω
Camera
1
2345
15
14
8
11

18
MK-09W
Dimensions: 218×167×33 mm
1) audio-red
2) ground-blue
3) camera power supply-yellow
4) video-white
8) (+) of power supply-red
9) (-) of power supply-black
J1, J2, J3 jumper configuration:
J1: switching on or off the chime in the door station
a) jumper put on – audible chime
b) jumper removed – chime off
J2: fit the cable in the video line
a) jumper put on – coaxial cable, if the system has more than one monitor installed,
leave only the jumper in the last monitor and remove it in all the other monitors
b) jumper removed – other cable
J3: switching on or off the backlight of the call button and the signboard in KK-04
door station:
a) jumper put on – backlight on
b) jumper removed – backlight off
In case of door stations other than KK-04, the jumper must be removed.
connection
of the DC 14.5 V
power supply
12
3
4
12
3
4
89
J3
J2
J1
POW
10 10 1
2
3
4
1
2
3
4
8
9
J3
J2
J1
POW
connection
of the door
station 2
connection
of the door
station 1
1
245
8 9
10
11
14

19
MK-10F
Dimensions: 241×161×23 mm
J1, J2, J3 jumper configuration:
J1: switching on or off the chime in the door station
a) jumper put on – audible chime
b) jumper removed – chime off
J2: fit the cable in the video line
a) jumper put on – coaxial cable, if the system has more than one monitor installed,
leave only the jumper in the last monitor and remove it in all the other monitors
b) jumper removed – other cable
J3: switching on or off the backlight of the call button and the signboard in KK-04
door station:
a) jumper put on – backlight on
b) jumper removed – backlight off
In case of door stations other than KK-04, the jumper must be removed.
Save photo button
Preview photo button
Navigation cursors
1) audio-red
2) ground-blue
3) camera power supply-yellow
4) video-white
8) (+) of power supply-red
9) (-) of power supply-black
10) connection to the control input
of the door automaton, it is a closing
contact of the NO relay (dry contact).
Do not connect voltages greater than 24 V,
the current should not exceed 150 mA.
10 10 1
2
3
4
1
2
3
4
8
9
J3
J2
J1
POW
connection
of the DC 14.5 V
power supply
connection
to the control input
of the door automaton
10 10 12
3
4
12
3
4
89
J3
J2
J1
POW
connection
of the door
station 2
connection
of the door
station 1
15
1
2345
14
8 9
10
11

20
MU-01
Dimensions: 100×200×45 mm
connection
of the DC 14.5 V
power supply
1234
1234
8 9
J3
J2 J1
POW
MU-02
Dimensions: 160×120×42 mm
J1, J2, J3 jumper configuration:
J1: switching on or off the chime in the door station
a) jumper put on – audible chime
b) jumper removed – chime off
J2: fit the cable in the video line
a) jumper put on – coaxial cable, if the system has more than one monitor installed,
leave only the jumper in the last monitor and remove it in all the other monitors
b) jumper removed – other cable
J3: switching on or off the backlight of the call button and the signboard in KK-04
door station:
a) jumper put on – backlight on
b) jumper removed – backlight off
In case of door stations other than KK-04, the jumper must be removed.
1) audio-red
2) ground-blue
3) camera power supply-yellow
4) video-white
8) (+) of power supply-red
9) (-) of power supply-black
earphone
connection
1 2 34
1234
connection
of the DC 14.5 V
power supply
8 9
POW
J3
J1
connection
of the door
station 2
connection
of the door
station 1
connection
of the door
station 2
connection
of the door
station 1
7
1
3
4
12
8
9
10
1
2
7
4
5
This manual suits for next models
8
Table of contents