Opus OP-6505H User manual

Digital Window Intercom
User Guide
2023
OP-6505H
1

2

Summary…………………………………………………………………………………………….……. 3
Safety precautions………………………………………………………………………………………… 4
Product introduction……………………………………………………………………………………. 5
Features………………………………………………………………………………………………….…… 5
Hardware interface instruction……………………………………………………………….…… 6
Packing list……………………………………………………………………………………….………….. 7
Wiring………………………………………………………………….………………………….…….…….. 8
Basic function……………………………………………………………………………………….……… 9
Local intercom……………………………………………………………………………….………….…. 9
Remote intercom………………………………………………………………………….……………… 9
Scene mode adjustment…………………………………………………………….…………………
Engineer settings…………..………………………………………………………………………………
9
9
Recording…………………………………………………..………………………………….…………….. 10
Fault exclude………………………………………………………………………………………………… 10
Connect OP-6505B……………………………………………………..…………………………… 11
Connection diagram ………………………………………………………………………………….. 14
Contents
3

Summary
Warning and Reminding
This symbol means there are potential safe troubles, it may cause death or
serious injury with incorrect operation.
This symbol used to remind the user that this device attached the important
operation and maintenance instructions.
Setting and Installation
• Avoid wet by water.
Do not put the machine to be exposed to rain water or other liquid stained environment,
otherwise it may lead to fire or get an electric shock.
• Do not use the other power voltage.
Using the device marked voltage to connect it.
It may lead to fire or electric shock if using the higher voltage.
• Do not scratch the power cord.
Don’t scratch, cut or twist the power cord.
Please keep the power line far away from the heated object and do not put heavy things on it,
otherwise it may lead to fires or electric shock.
Using machine
• In case of the anomalies appears.
Please shut off the power supply immediately when finding the following abnormal phenomena
within using, please contact with supplier. It may cause fires or electric shock if it`s still using it.
When the device with smoking or strange flavor.
The device internal is invaded by water or other things. Device fall off or device shell is damaged.
The power cord is damaged (wire core is exposed or broken etc). Device fault (it can`t connect
network, no sound etc.).
• Do not open the device internal or modify the device Don`t make other things invaded to the
device internal.
Don’t make the metal items or inflammable objects inserting to device internal, otherwise it will
cause fires or electric shock.
• Do not touch when lightning
To avoid electric shock, please do not touch the device and the plug while lightning.
• Do not put the liquid container or metal object on the device
If the container is fall down and make the liquid permeate into the device, it will cause fire or
electric shock.
• Do not open the device internal or modify the device
The device internal contains high voltage parts, once open the cover or modify the device, it may
cause fires or cause shock.
All about device maintenance and modification should be operated by professional personnel.
•The notice for maintenance or long time without using
Please shut down the power and pull out the power line while maintenance or the device won`t
be used for 10 days or more.
It may cause electric shock or fires if do not make it.
4

Internal window intercom Internal window intercom
Features
•Adopt single DSP multi-channel language auto-control technology, avoiding squeaking and
disturb to realize real digital full-duplex intercom.
•Adopt full touchable transparent key design, keep intercom without disturb from key-click
and keep it with the halo light on.
•Recognizing sound source, control environment noise, automatically adjust volume and
restore the original sound.
•Providing three mode scene (quiet, standard, noisy), support one-key adjustment.
•Wiring external and internal intercom adopt one line to connect the desk, better solving
the loosen caused by moving and keeping the desk more clear and beautiful.
•Professional cavity structure design, adopting hard metal cavity to prevent machine
resonance, purify and naturalize the sound to transparent.
•Personalized and customized service language, manual broadcasting “Hello, welcome”,
“Thank you welcome for next time coming”
•Support double recording mode and providing the recording output to HD recording host
and DVR to process the third-party recording storage.
•LED distinguished show the real state of internal window intercom.
•Mic headset function to allow agent to isolate themselves from background noises
Coordinate HD recording host function:
•Realizing remote calling and receive calling, hands-free intercom with central microphone.
•Remote central microphone can real-time monitoring window intercoms.
•Receiving remote one-way network broadcasting.
•Internal window intercom can make real-time recording by the record key and it will be
stored on the HD recording host.
•Remote upgrading the firmware of window intercom in the HD recording host web page.
5

Hardware interface instruction
Internal window intercom
【Front view】
①Working indication light: red light is offline, green light is online
②Loudspeaker: amplify the local intercom audio.
③Recording key: make a recording when press the key at the first time, finish the recording
by press again, the recording key will quickly red flashed in the recording process.
④Intercom key: press the key to intercom with external window intercom, finish the
intercom by press again, the green intercom key will be light on.
⑤Microphone pole socket: plug the microphone pole, collecting local intercom audio.
⑥Voice broadcasting key remote intercom key:
Voice broadcasting: Press voice broadcast key to automatic play voice prompt in the process
of intercom with window external terminal, press shortly to prompt "Hello, welcome", long
press for a while to prompt "Thank you, welcome to come next time.". The broadcasting key
green flashed during the process of broadcasting.
Remote intercom: coordinate with HD recording host to use, click this key to call named
terminal by server in the online condition.
【Side view】
①Scene mode regulating switch:3 scene mode adjustment 【noisy(1)、standard(2)
、quiet(3)】, defaulted as standard mode.
【connection wiring】
②Headset mic connection
6

①Power interface: connect with DC12/2A power.
②Communication interface:connect with the network HD recording host.
③Analog audio input interface: output analog audio, connect with DVR or camera.
④External window intercom interface.
【External window intercom】
①Loudspeaker/MIC:
Loudspeaker:amplify the local intercom audio;MIC:pick up the local intercom audio;
②Internal window intercom interface
Packing list
Window intercom system include following accessories, please check following parts, please
contact with distributor if any parts are missing.
(1)Internal window intercom 1 set
(2)External window intercom 1 set
7

(1)Microphone pole 1 pcs
(2)Power adapter 1 pcs
(3)Wiring harness (3*100mm)3 pcs
(4)Cable clamp (HC-100) 3 pcs
(5)Wiring connector (3.81-2P) 1 pcs
(6)Quick installation manual 1 pcs
( 7 ) Headset ( only with the OP-6505HK)
8

Basic function
Local intercom
After connected internal window intercom and external window intercom, then power-on.
Press the intercom key of internal window intercom, it can digital full duplex HD intercom with
external window intercom, press again to stop intercom.
Remote intercom
Used with HD recording host, under the online status, press remote intercom key to call the
server pointed terminal.
9
Wiring
(1)Connect the one port of power adapter to the power interface of internal
window intercom, the other port connect with power socket.
(2)Connect interface of external window intercom with internal window intercom.
(3)Connect the one port of Ethernet to internal window communication interface
and the other port connect to HD recording host (only suitable for online environment).
( 4 ) Connect the headset’s adaptator to the Central Unit

Fault exclude
Why the terminal can not talk with others?
1. To realized talking with other terminals, it must be through HD recording host. Check
whether connect with HD recording host.
2. Check server mapping settings is right or not.
Why recording host can not login to the server?
1. Check whether connect with HD recording host.
2. Check the software server and the main controller is normal opened or not. It is
required to close all firewall before open the software server (including system built-in
firewall and other antivirus software firewall).
3. Check the terminal network cable and switcher whether work normal, damaged, and
disconnect or not etc;
4. Check the HD record host settings, please check the terminal ID...etc parameters.
10
Recording
Analog recording
Window internal intercom can output analog audio, and it is ok for connect with the DVR to
make auto-recording.
Scene mode adjustment
Window intercom provides three scene modes: Noisy (1), Standard (2), Quiet (3) 】; the
default mode is standard mode.
Incoming prompt tone:
Press voice broadcast key to automatic play voice prompt in the process of intercom with
window external terminal, press shortly to prompt "Hello, welcome", long press for a while
to prompt "Thank you, welcome to come next time.". To finish the audio note broadcast by
long press this key or click other keys.
Engineer settings:
First your devise need to be off, then press simultaneously the intercom button and
on the voice broadcasting key remote intercom key for few seconds.
Once the devise turn on, the middle key should flash and the two other keys should be
light on. For adjusting the volume on the agent side, press briefly the key for turning
up or press for a long time for turning down.
For adjusting the volume on the public side, do the same manipulation with key.
For leaving the engineer settings, press the key for five seconds.

Conversion tables
In this manual, SI units are used to expresslengths, masses, temperatures etc.
These can be converted to non-metric units using the following information.
Table 1: lenght units conversion
Table 2: Mass unitsconversion
Table 3: Pressure units conversion
Table 4: temperature unitsconversion
25,40 mm = 25,4 mm 1 mm = 1,00000
25,40 mm = 2,54 cm 1 cm = 0,3937 po
30,48 cm = 0,3048 m1 m = 3,281 pd
1 ml = 1,609 km 1 km = 0,622 ml
1 lb = 0,4536 kg 1 kg = 2,2046 lb
1 psi = 68,95 hPa 1 hPa = 0,0145 psi
Note:
1 hPa = 1 mbar
°F = 9 /5. ( °C + 32 °C = 5 /9. ( ° F 32)
11
Connect DCL20-65 Loop Amplifier (for OP-6505HB Versions)
The DCL20-65 is an induction loop kit that can be used to equip counters or reception
desks.The system allows to meet the restrictions of the law of european equal treatment
directives while respecting the requirements of EN60118-4. The set is designed to offer
accessibility to hearing-impaired equipped with a T-position on their hearing aid.
The amplifier is designed to be discreetly attached under adesk or counter.It is equipped
with two inputs, settings and LEDs indicating the presence of power supply and loop
current.
The device incorporates an audio processing to have an automatic control of the sound
levels, avoiding loud and suddennoises.