manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. faucet strommen
  6. •
  7. Switch
  8. •
  9. faucet strommen 30576 User manual

faucet strommen 30576 User manual

Suits Models:
30576, 30736, 30958, 30959, 35140
Important requirements:
Cleaning
Clean only with a soft microfiber or similar cloth and warm clean water. Ensure that
the cloth is clean and free of any grit or chemical. Dry tap o with a soft clean cloth.
Ensure that your tap is not subject to any chemicals, building grit or any type of
abrasive of polish. For care of special finishes please visit our website.
Maintenance
Aerators may need to be flushed from time to time if flow diminishes or stream
pattern deteriorates. For Pegasi & Cascade mixers, use the aerator key provided
to unscrew the aerator. You will notice a “castle” pattern around the edge of the
aerator, the key engages with this allowing you to unscrew the insert easily. For Zeos
models, use the aerator key to unscrew the aerator housing, you will then be able to
pop the insert out the top of the housing. Rinse o the upper face of the insert with
running water and gently brush clean with an old toothbrush to remove any debris
before refitting the aerator.
Installation Guide IG 029
Diverter Switches
Products Warranty – Australia
Faucet Australia Pty Limited (ABN 83 683 523 321) warrants its products to the original owner as per the periods in the table below. This
Warranty applies to all product purchased on or after 24 Oct 2017. Our liability under this warranty is limited at our option to the repair or
replacement of the defective product or part, the cost of repair of the defective product or part or the supply of an equivalent product or part,
in each case if we are satisfied the loss or damage was due to a defect in the materials or workmanship of the product or part.
Note: “Residential” refers to normal residential domestic purposes including houses and residential apartments. “Commercial;” refers to all
non-residential purposes including Hotels, Schools, Care homes, Hospitals, clubs etc.
Exceptions
Defects caused by improper use, improper installation, surface damage caused by installation, improper care of the product or failure to
observe any one or more of the following will not be covered by this Warranty:
1. Applicable Health Acts;
2. Installation in accordance with manufacturer’s instructions and specifications (Note: Tapware, mixers and filters must be installed
by qualified plumber);
3. All products to be cleaned with only warm water and a soft clean cloth
4. Tapware and showers to be supplied with only clean potable water
5. Tapware and showers to be subject to no more than 700kpa whether during use or during site testing, and site must be fitted with
500kpa mains pressure limiting valve.
6. Tapware and showers to be subject to water temperatures no hotter than 65 degrees Celsius
7. Tapware and showers to be installed in accordance with AS/NZS 3500 and other standards which govern the water supply and
sewerage plumbing requirements at the location of installation.
Limitations
8. Warranty does not cover fair wear and tear on sealing rings and washers. Depending on usage and conditions these may have to be
replaced within the Warranty period;
9. For finishes, this warranty does not cover damage caused by use of chemicals or detergents or abrasives and is limited to coating
failure by bubbling, cracking or flaking. Note that Organic finishes are expected to change colour, develop patina and verdigris.
10. Does not cover any loss or damage sustained by the consumer (including consequential loss or damage), in respect of the product
or failure or omission on the part of Faucet Australia to comply with its obligations under these conditions.
11. For Baths & Basins, The warranty does not cover damage caused by exposure to direct sunlight or UV, exposure to temperatures
over 60 degrees Celsius, damage caused by dropping sharp or heavy objects.
12. For Baths and basins this warranty does not cover damage caused by Strong Chlorinated solvents, Chloroform, Chlorobenzene,
Nail polish remover, Methylene Chloride, Acetone, Turpentine, Ethyl Acetate, Acids, Ketones, Phenols, Ethers, Drain Cleaner, Toilet
Cleaner, Salts, Oils, Milks and bathwater additives, non-approved liquids or Chemicals.
Lodging a claim
Claims must be lodged immediately or within 3 days of detection. Proof and Date of purchase from a Faucet Strommen dealer along with
site details and contacts will be required to process a claim. All claims must be lodged with Faucet Australia via one of these methods:
Phone: 03 5450 4236
Email: [email protected]om.au
Mail: PO Box 271 Kerang VIC 3579
Your costs in making a claim under this warranty, including all freight, collection and delivery costs are to be borne and paid by you. We also
reserve the right at our cost to inspect any alleged defect in the product wherever it is located or installed or on our premises.
Other Conditions
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or
refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the
goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Faucet Australia Pty Ltd 24 Oct 2017
Product Category Residential Warranty Period Commercial Warranty Period
Tapware, Showers, Accessories 5 Years parts & labour + 10 years parts 2 Years parts & labour + 3 years parts
Intro Tapware 1 Year parts & labour + 4 years parts 1 Year parts & labour
Silkstone Baths & Basins Lifetime 2 Years parts & labour
Special Finishes 5 Years parts & labour 2 Years parts & labour
Faucet Australia Pty Ltd ABN 83683523321 31 Tate Drive, Kerang VIC 3579
www.faucetstrommen.com.au P: +61 3 5450 4236 [email protected]u
Must be fitted in
accordance with
AS/NZS 3500
by qualified
plumber
Mains
500kpa
regulator
must be
fitted
Maximum hot
water temp.
65°C
Water lines
must be
flushed prior
to connection
Only clean
municiple water
supply. No bore,
dam or hard water
without filtration
& treatment
Release Date: 24.02.22
Rough In:
1. Ensure that the in-wall depth is correct. It is advisable to get the depth as accurate as
possible at rough in so that you don’t run out of adjustment at fit o. Position the noggin
such that the front face of the noggin is between 45-70mm max from the front face of the
finished tiled surface. Take into account the thickness of the tiles, tile glue, plasterboard
etc.
2. Fix the mixer body to the stud ensuring correct orientation.
3. Connect the supply to the right side inlet marked “In” and the outlets to the top and
bottom ports marked “Out 1“ and “Out 2”
4. Once plumbing is connected pressure test the system. Do not exceed 500kpa pressure
testing whether dynamic or static. Testing over 500 kpa will void the warranty for this
product.
5. A rubber protector cover is fitted over the mixer body to protect it from damage. Keep this
in place at all times, remove only for testing operation.
6. Once wall sheeting is complete apply waterproofing membrane up to the black plastic
shroud.
7. When tiling, note the size of the flange (55mm min all models) and make sure that tiling is
cut close so that the flange covers the tile hole.
8. Once tiling and grouting are complete remove the rubber protector cover, use a box
cutter or sharp chisel to carefully cut away what is protruding of the black plastic shroud,
then replace the protective cover until fit o stage.
9. Note that the Rough in kit does not contain and decorative components as these are all
in the fit o kit.
Fit O:
Fit o is done after tiling and grouting are complete.
1. Ensure that the area around the tap is clean and free from grout lumps, tile glue or
sealant.
2. Remove the rubber protector cover from the tap and ensure that there is no tile glue or
deposit on the brass cylinder or thread.
3. Wipe the cylinder clean of dust & grit
4. Unwrap the decorative sleeve then slide the sleeve over the wall mixer with the thread to
the back. Screw all the way down.
5. Unwrap the cover flange, moisten the inside o-ring and push this flange over the sleeve
up against the tiles being careful to keep it straight so it does not scratch the sleeve.
6. Fit the handle to the mixer with the pin hole to the top for Pegasi, Zeos and Cascade, and
to the bottom for Zero. Press the handle all the way on, then tighten the grub screw that is
inside the pin hole of the handle using the Allen key provided, tighten firmly.
7. Screw the pin into the pin attachment thread for Pegasi, Zeos and Cascade and fasten on
firmly by hand.
8. If you want pin facing down, remove the splined adaptor, rotate hole to the bottom and fit
handle accordingly.
Run the tap and check all operation is correct. If there are any issues please contact Faucet
Strommen before leaving the site.
Min 45 mm - 70 mm max
Noggin

This manual suits for next models

4

Popular Switch manuals by other brands

Planet WGSW-24000 user manual

Planet

Planet WGSW-24000 user manual

j5 create JUC400 user manual

j5 create

j5 create JUC400 user manual

System air Fantech RTS-W Installation and owner's manual

System air

System air Fantech RTS-W Installation and owner's manual

AirLive POE-GSH800-120-BT Quick setup guide

AirLive

AirLive POE-GSH800-120-BT Quick setup guide

Connect Pro Master-IT StreamLine SL-18 user guide

Connect Pro

Connect Pro Master-IT StreamLine SL-18 user guide

Black Box ServSelect KV124A-PS2 instruction manual

Black Box

Black Box ServSelect KV124A-PS2 instruction manual

Black Box 26611 datasheet

Black Box

Black Box 26611 datasheet

Kromschroeder DL ET Series operating instructions

Kromschroeder

Kromschroeder DL ET Series operating instructions

Delta LE-764501 user manual

Delta

Delta LE-764501 user manual

I-Tech USB Hub DB-15 IP 2-console KVM user manual

I-Tech

I-Tech USB Hub DB-15 IP 2-console KVM user manual

red lion N-Tron Series Software user manual

red lion

red lion N-Tron Series Software user manual

Silvercrest DZKW 20-A DE Operation and safety notes

Silvercrest

Silvercrest DZKW 20-A DE Operation and safety notes

3One data ICS6420 Series Quick installation guide

3One data

3One data ICS6420 Series Quick installation guide

Planet IGS-6325-8T4X Quick installation guide

Planet

Planet IGS-6325-8T4X Quick installation guide

Guard master Spartan Installation instructions manual

Guard master

Guard master Spartan Installation instructions manual

Watchguard Firebox M370 quick start guide

Watchguard

Watchguard Firebox M370 quick start guide

Black Box LB8422A-US user guide

Black Box

Black Box LB8422A-US user guide

Planet LRP-422CST Quick installation guide

Planet

Planet LRP-422CST Quick installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.