Fema Electronica BDF Series User manual

Series BDF
Large Displays for parallel BCD code
Large
Displays
FEMA ELECTRÓNICA
USER’S MANUAL
(1279R01)
IDEAL SOLUTION to display numerical values at long distances,
controlled by parallel BCD signal, in 4 and 6 digits format. Very strong
housing and electrically protected units, designed for all type of industrial
applications.
BDF-xx-BCD Repeater for parallel BCD

User’s Manual BDF-xx-BCD
FEMA ELECTRÓNICA - Page 2
FEMA ELECTRÓNICA - Page 3
Model BCD
Large displays for parallel BCD code
The BDF series of large displays for parallel BCD signal is
available in 4 and 6 digits format with 57mm or 100mm digit
height. Digits are 7 segments in red color (optional green led,
ask for information).
The display value of each digit is controlled by BCD code.
Several parallel lines control all digits (lines ABCD indepen-
dent for each digit). Control to light the decimal point indepen-
dent for each digit, control for «HOLD» function to block the
refresh of each digit, and control for negative sign (polarity)
Function «BLANK» to switch-off all segments and function
«TEST» to light all segments.
The mechanical of the BDF instruments is a very strong and
sturdy aluminium housing anodized in black color, for panel
mount, and for wall mount as an option. The front lens is
antirreexive and is rmly inserted on the aluminium prole
with a rubber gasket around, providing IP65 protection on
the front.
The signal wires are connected to plug-in screw clamps for
higher security of the connections, accessible at the rear side
of the instrument. The power is connected to a 3 terminal plug
(2 power connections and 1 earth) containing an integrated
protection fuse and an additional fuse as spare part.
SIZE BDF-24 - Instrument with 4 digits
digit 57mm height (2,3’’)
SIZE BDF-44 - Instrument with 4 digits
digit 100 mm height (4,0’’)
SIZE BDF-26 .- Instrument with 6 digits
57mm digit height
SIZE BDF-46 .- Instrument with 6 digits
100mm digit height
Sizes
Order reference
BDF BCD
Model
-BCD
--- 0
Power
-0 (230 Vac)
-1 (115 Vac)
-6 (24 Vdc
isolated)
----
Others
-65 (IP65)*
-(empty)
R
Color
-Red
-Green
(check for
availability)
-
24
Size
-24
-44
-26
-46
* the IP65 option uses a completely
different type of housing from the
indicated in this documentation.
Check the BDF IP65 housing docu-
mentation for more information.

FEMA ELECTRÓNICA - Page 2
User’s Manual BDF-xx-BCD
FEMA ELECTRÓNICA - Page 3
DISPLAY 4 or 6 digits in red color
7 segment Led
reading from -9999 to 9999 in 4 digits
reading from -999999 to 999999 in 6 digits
decimal point selectable
digit 57 mm (2,3”) in BDF-24 and BDF-26
digit 100 mm (4,0”) in BDF-44 and BDF-46
antirreexive front lter
IP65 front protection
DATA parallel BCD code
LOGIC positive
logical level «1» >4,3 Vdc (max. 40 Vdc)
logical level «0» <1,1 Vdc.
HOLD «HOLD» active in logical state «1».
independent for each digit
independent for the negative sign
in level «0» reading updates continuously
TEST active in logical state «0».
lights all segments «-8.8.8.8.8.8.»
BLANK active in logical state «0»
lights-off all segments
NEGATIVE negative sign active in logical sate «0»
with independent «HOLD» control
CONSUMPTION BY CHANNEL
4 mA at 24 Vdc
1,5 mA at 12 Vdc
150 µA at 5 Vdc
ENVIRONMENTAL DATA
Working Temp. 0/+50ºC (32/122 ºF)
Storage Temp. -20/+85°C (-4/185ºF)
Rel. Humidity 0 to 85% non condensated
HOUSING extruded aluminium
anodized in black color
for panel mount (optional wall mount)
POWER SUPPLY
standard 230 Vac 50/60 Hz
(optional 115 Vac 50/60 Hz)
(optional 24 Vdc isolated)
CONSUMPTION
6 VA in series BDF-24 and BDF-26
12 VA in series BDF-44 and BDF-46
General specications
Front view
Selectable decimal point
Negative sign
Instruments BDF for parallel BCD code are available in 4 or
6 digits format. Digits are led type 7 segments, with decimal
point and negative sign.
Negative sign Selectable decimal point
Digit 1
Digit 1
Rear view
Power
(includes fuse)
Connector 1
Connector 2

User’s Manual BDF-xx-BCD
FEMA ELECTRÓNICA - Page 4
FEMA ELECTRÓNICA - Page 5
Signal connections
Signal connections at male SUB-D connector available at
the rear of the instrument.
Each digit has 4 connection lines (ABCD) for its BCD code,
1 «Hold» line controlling the display update, and 1 control
for the decimal point.
The negative sign has 1 control line and 1 line for «Hold».
Connection lines identied as «+5Vdc» can be used as xed
controls with logical state «1».
Connection lines identied with «GND» can be used as xed
controls with logical state «0».
The «Digit 1» is the Least Signicant Digit.
Digit X BCD Value Display
D C B A
0 0 0 0 0 0
0 0 0 1 1 1
0 0 1 0 2 2
0 0 1 1 3 3
0 1 0 0 4 4
0 1 0 1 5 5
0 1 1 0 6 6
0 1 1 1 7 7
1 0 0 0 8 8
1 0 0 1 9 9
1 0 1 0 10 A
1 0 1 1 11 b
1 1 0 0 12 C
1 1 0 1 13 d
1 1 1 0 14 E
1 1 1 1 15 «BLANK»
Digit 3-A
Gnd
Hold 2
Digit 2-D
Digit 2-C
Digit 2-B
Digit 2-A
Gnd
Hold 1
Digit 1-D
Digit 1-C
Digit 1-B
Digit 1-A
Blank
Test
Hold 4
Digit 4-D
Digit 4-C
Digit 4-B
Digit 4-A
Gnd
Hold 3
Digit 3-D
Digit 3-C
Digit 3-B
13
12
11
10
9
8
7
6
5
4
3
2
1
25
24
23
22
21
20
19
18
17
16
15
14
Not connected
+5 Vdc
+5 Vdc
Decimal 1 point
Decimal point 2
Decimal point 3
Decimal point 4
Decimal point 5
Decimal point 6
GND
Hold Negative sign
Negative sign
Gnd
Not connected
Hold 6
Digit 6-D
Digit 6-C
Digit 6-B
Digit 6-A
Gnd
Hold 5
Digit 5-D
Digit 5-C
Digit 5-B
Digit 5-A
13
12
11
10
9
8
7
6
5
4
3
2
1
25
24
23
22
21
20
19
18
17
16
15
14
Connector 2 Connector 1

FEMA ELECTRÓNICA - Page 4
User’s Manual BDF-xx-BCD
FEMA ELECTRÓNICA - Page 5
SECTION BLANK
Power supply connections
The power connector allows one terminal for earth and two
power terminals. Internal fuse is integrated on the connector
and an additional fuse is available as a spare part. The value
of the fuses depends on the power supply, and is according
to rule IEC127/2
230 Vac - 200 mA fuse time-lag
115 Vac - 400 mA fuse time-lag
24 Vdc - 350 mA fuse fast
Powered
230 Vac (115 Vac optional)
Powered
24 Vdc Isolated
+ -
Fuse

User’s Manual BDF-xx-BCD
FEMA ELECTRÓNICA - Page 6
FEMA ELECTRÓNICA - Page 7
Introduce instrument «1» into the panel cut-out and place the
xation piece «3» on each side. Place screw «2» through xa-
tion piece «3» until it presses the panel «4» and is rmly xed.
Note - The front of the instrument is sealed IP65. To have the
same level of protection between the panel and the instru-
ment, place a rubber prole (squared or round) as indicated
«5».
Panel installation
1- Instrument BDF
2- Screw
3- Fixation tool
4- Panel
5- Rubber prole
Antirreexive lter
Rear cover
A
B
C
Note .- add 27mm to the «C» dimension for the power supply plug
4 digits 57mm 264mm 120mm 112mm
(2’’) (10,40’’) (4,75’’) (4,41’’)
Size 24 A B C
4 digits 100mm 480mm 180mm 112mm
(4’’) (18,90’’) (7,09’’) (4,41’’)
Size 44 A B C
Mechanical dimensions
PANEL CUT-OUT
Panel width
Max. 14 mm (0,55’’)
Min. 2,5 mm (0,10’’)
D
E
4 digits 100mm 472mm 172mm 5.0 Kg
(4’’) (18,58’’) (6,77’’) (11 lbs)
Size 44 D E weight
4 digits 57mm 256mm 112mm 2.3 Kg
(2’’) (10,07’’) (4,40’’) (5 lbs)
Size 24 D E weight
Panel cut-out and weights
6 digits 57mm 384mm 120mm 112mm
(2’’) (15,12’’) (4,75’’) (4,41’’)
Size 26 A B C
6 digits 100mm 668mm 180mm 112mm
(4’’) (27,10’’) (7,09’’) (4,41’’)
Size 46 A B C
6 digits 100mm 680mm 172mm 5.7 Kg
(4’’) (36,77’’) (6,77’’) (12,5 lbs)
Size 46 D E weight
6 digits 57mm 376mm 112mm 2.7 Kg
(2’’) (14,80’’) (4,40’’) (6 lbs)
Size 26 D E weight

FEMA ELECTRÓNICA - Page 6
User’s Manual BDF-xx-BCD
FEMA ELECTRÓNICA - Page 7
damages may result on both instruments.
POWER SUPPLY .- Connect the Power Supply to the terminals indicated in
this manual. Verify that the voltage and frequency of the
power supply is according to the voltage and frequency
values indicated in the label attached to the unit. DO
NOT connect the instrument to power lines which are
overloaded, or power lines with loads working in ON/OFF cycles, or with
inductive loads.
SIGNAL WIRING .- Information to consider relating the wiring of the sen-
sors, probes, transducers, etc. The wires can act as antennas and introduce
electrical noise from the environment into the signal wires, specially if the
wires are close to noise sources or electromagnetic sources. There are
several rules generally known which should be taken into consideration
for the wiring :
a.- DO NOT install impulse, control or signal wires together in the same
conduits as the wires connected to power lines, connected to CC or AC
engines, electromagnets, ...
b.- When using shielded wires, connect the shield to the common of the
instrument, and leave not-connected the probe side
c.- The wires of impulse, control and signal should be placed in places
far away from switches, transformers, control relays, etc...
IN CASE OF FIRE
1.- Disconnect the unit from the power supply.
2.- Give the alarm according to the local rules.
3.- Switch off all the air conditioning devices.
4.- Attack the re with carbonic snow, do not use water
in any case.
WARNING : In closed areas do not use systems with vaporized liquids.
Warranty
All instruments are warranted against all manufacturing
defects for a period of 24 MONTHS from the shipment date.
This warranty does not apply in case of misuse, accident or
manipulation by non-authorized personnel. In case of mal-
function get in contact with your local provider to arrange for
repair. Within the warranty period and after examination by
the manufacturer, the unit will be repaired or substituted when
found to be defective. The scope of this warranty is limited to
the repair cost of the instrument, not being the manufacturer
eligible for responsibility on additional damages or costs.
Manufacturer FEMA ELECTRÓNICA, S.A.
Altimira 14 - Pol. Ind. Santiga
E08210 - Barberà del Vallès
BARCELONA - SPAIN
www.fema.es - [email protected]
Series- BDF-24 y BDF-44
Models BCD
The manufacturer declares that the instruments indicated
comply with the directives and rules indicated below.
Directive of electromagnetic compatibility 2004/108/CEE
Directive of low voltage 73/23/CEE
Security rules 61010-1
Emission rules 50081-2
Immunity rules 50082-1
NOTE .- During an electromagnetic disturbance (10V/m) it is permitted a worst case error of 1% of
the A/D range. The instrument will recover automatically its functionality when the disturbance stops,
without need of the operator to reset or restart.
Barberà del Vallès October 2009
Daniel Juncà - Quality Manager
CE Declaration of conformity
INSTALLATION PRECAUTIONS.- The installation and
operation of this instrument must be done by qualied
operators. This instrument DOES NOT have power switch
and will start to operate as soon as the power supply is
connected. The instrument has an internal protection fuse, according to
IEC-127/2, and is located inside the power-supply connector. The values are
Fuse 200 mA Time Lag (for 230 Vac power)
Fuse 400 mA Time Lag (for 115 Vac power)
Fuse 350 mA Fast (for 24 Vdc power)
When the instrument is used to control machines or processes where the
personnel or the process can be damaged, the appropriate security ele-
ments must be added to the system in order to protect the operator and /
or the system.
SAFETY PRESCRIPTIONS.- This instrument has been designed and veri-
ed according to the UNE-20553 rules and is delivered in perfect
conditions of operation. This manual contains the adequate infor-
mation for the electrical installation. Before starting operations for
connections, readjustment, substitution, maintenance, repair, etc,
the instrument must be unplugged from the power supply. The instrument
must be installed in places with good ventilation to avoid excessive heating,
and far from sources of electrical noise or magnetic eld generators, such as
power relays, electrical motors, speed controls, etc... The instrument can not
be installed in open places. Do not use until the installation is nished. The
instrument is designed to be mounted on a metallic panel with the adequate
protections. DO NOT clean the front lens with abrasive products (such as
solvents, alcohol, etc) use a clean and water humid rag. Do not expose the
instrument to excessive moisture. DO NOT operate the unit in the presence
of ammable gases or fumes.
EXCITATION VOLTAGE Vexc.-
Instruments BDF-xx-32 and BDF-xx-36 supply an excitation voltage of 10 to
24 Vdc (50mA) to power transducers, available between terminals A and C.
Do NOT connect these terminals to an external power supply, permanent
Precautions on installation

Large Displays
60 & 100 mm digit
Signal Converters
& Isolators
Panel Meters
Standard 96x48mm
other products
ELECTRONIC INSTRUMENTATION FOR INDUSTRY
www.fema.es
FEMA ELECTRÓNICA, S.A.
Altimira 14 - Pol. Ind. Santiga
E08210 Barberà del Vallès
BARCELONA - SPAIN
Tel. (+34) 93.729.6004 - www.fema.es
Fax (+34) 93.729.6003 - [email protected]