376 723
Operating instructions
Proximity switch
Naherungsschalter
Type SMPO-8E
Typ SMPO-8E
Part no. 178 563
Teile-Nr.
178 563
Bedienungsanleitung
What
do you need
to
know when using
Fe&o
equipment?
You must maintain the limit values given for
pres.
sure, speed, mass, lateral forces, temperature and
follow the instructions given as these are the con-
ditions for proper function and therefore must be
absolutely guaranteed by the user.
Make sure that operations are carried out using
correctly prepared compressed air without any ag-
gressive media. In addition, follow the respective
environmental conditions which are valid for the
place of use.
If using Festo equipment in a safety area,
the
re-
spective regulations of trade
associttions
and of
the technical
surveyance
society (TUV) or the cor-
responding national agreements must be followed.
Was
ist
beim
Einsatz
von
Festo
Elementen
zu
beachten?
Die
Einhaltung
der jeweils angegebenen
Grenz-
werte
fiir
Dri.icke,
Geschwindigkeiten,
Massen,
Querkrtifte,
Temperaturen und die Beachtung von
Hinweisen ist Voraussetzung
fiir
die
ordnungs-
gemsBe
Funktion
und daher vom Anwender un-
bedingt
zu
gewahrleisten.
Es ist auf den Betrieb mit
ordnungsgemti8
aufbe-
reiteter
Druckluft
ohne aggressive Medien
zu
ach-
ten.
AuBerdem
sind die jeweiligen
Umweltbedin-
gungen am Einsatzort
zu
berticksichtigen.
Bei
Anwendung von Festo-Elementen im Sicher-
heitsbereich sind stets
such
die jeweiligen
Vor-
schriften der Berufsgenossenschaft und des
Technischen
uberwachungsvereins
bzw.
die ent-
sprechenden nationalen Bestimmungen
zu
be-
achten.
FESTO
PNEUMATKZ
FESTO
AG
&
Co.
.
Postfach
.
D-73726
Esslingen
Telefon 071
l/
347-
0
1. Components and connections
1.
Bedienteile
und
Anschitisse
@
Compressed air connection 1
@
output 2
@
Exhaust 3
@
Through hole for mounting kit
(1
Nm)
@
Output indicator
@
Druckluftanschlul3
1
@
Ausgang 2
@
Entltiftung
3
@
Durchgangsbohrung
for
Bausatzbefestigung (1 Nm)
@
Ausgangsanzeige
2. Technical data
2. Technische Daten
Mountingposition
I
in
the
sensor grooveof
Festo-cyl.
types
DNC,
DGP,
DZF,
ADVU
Einbaulage
inder
Sensornut
der
Festo-Zylinder
DNC,
DGP,
DZF
und
ADVU
Medium
/
Compressed air, filtered non-lubricated
/
Medium
gefiherte,
nicht
ge6ke
Drucklufl
Filter fineness
/
Filterfeinheh
40
urn
maximum Imax. 40
urn
Connection
/
Anschlul3
Pressure range
/
Druckbereich
Reproducible switching accuracy
/
Connections
(I,
2 and 3)
with
M5 thread for screw connectors
tvoe
LCN-M5PK4
or QSML-M5-4
fs
2.5
Nrnj
/
i&chl&se
(I,
2 und 3)
rnit
M5-G&inde
ftir
cerschraubungen
Typ
LCN-M5-PK4
oder
QSML-M5-4
(5
2,5
Nm)
2 to
/
bis max. 8 bar
*
0.008 in
/
*
0.2 mm
Sciakpunkt
Wiederhoigenauigieit
*
0,2
mm
Temperature range
/
Temperaturbereich
Operation I
Setrieb
-
15 to/his
60°C
use dried compressed air for minus
ternperatL
res
/
bei
Minustemperaturen
getrocknete
Druckluft
verwenden,
~~Oragc?/~agertmg
-
20to/bis80°C
Degree of protection
to
EN
6Q
529
IP
65
Schutzarl
nach EN 60 529
IP
65
Materials
/
Housings, caps: PA 6
Threadet
inlet, cover: Al
Pins: brass Sealings:
NSR
Werkstoffe
Gehtiuse,
Kappe: PA 6
Gewindeeinsatz,
Deckel:
Al
Stifte:
Messing Dichtungen:
NBR
3. Installation
3. Montage
l Screw the switch into the clamping part
@
of the mounting kit type SMB-8E (not
0
Naherungsschalter
auf
das
Klemmstijck@
included in delivery). des Befestigungsbausatzes Typ SMB-8E
(nicht
im Lieferumfang enthalten) schrauben
Fixings for Festo cylinder types:
-
DNC-
.
-DZF-...
-
DGP-
-
ADVU
-
.
.
.
Befestigung fur Festo-Zylindertypen:
-
DNC-
.
-
DZF
-
.
-
DGP-
.
-
ADVU
-
A
!
Warning:
Incorrect switching due to ferromagnetic
metal shavings on the proximity switch.
Make sure that all materials (except for
the cylinders to be interrogated) are kept
away from the SMPO-8E (e.g. by
user-
made protective covers or immediate cle-
aning of the dirt).
A
!
Warnung:
Fehlschaltungen durch Ansammlung von
ferromagnetischen
Metallspanen
am
Na-
herungsschalter.
Stellen
Sic
sicher,
da8
samtliche
ferro-
magnetischen Stoffe (mit Ausnahme des
abzufragenden Zylinders) vom
SMPO-8E
ferngehalten werden
(z.B.
durch
selbst-
gefertigte Schutzabdeckungen oder
so-
fortige Reinigung
bei
Verschmutzung).
0
Insert the preassembled unit into the cy-
linder groove and place in the interroga-
tion position.
l Vormontierte Einheit in die Zylindernut
ein-
fi.ihren
und in Abfrage-Position plazieren.
Extension for the
DNC cylinder Anbau an
Festo-Zylinder DNC
0
Sizes
DGP-8-1.
I-28.
.
and
ADVU-/
0
Der Naherungsschalter kann die Zylinder-
AEVU-12-/.
/-20-. can be built over
grof3en
DGP-a-/.
./-20-.
.
und
ADVU-/
the proximity switch.
AEVU-12~/.
.
/-20-.
Liberbauen
4. Startup
1.
Move the cylinder to the end position.
2. Apply compressed air of between 2 bar to
max. 8 bar to port
(iJ
3.
Utilize port
Qfor
further signal proces-
sing. Example: input
“X”,
sequence con-
trol, Festo Quickstepper.
4. Move the proximity switch until it reaches
the switching point (compressed air signal
at port (A) of the amplifier); then a few
millimetres
further in the same direction
until is switches back.
5,
Position the proximity switch with the
threaded pin at the half way point between
the switch-off states.
5.
Operation
a) To minimize interference from adjacent
magnetic fields, a large space must exist
between adjacent cylinder barrels, or
from the proximity switch.
b) The switch must be at a large distance
from any ferromagnetic components.
c) Port
@I
must remain open.
6. Maintenance and care
0
Clean the proximity switch if it gets dirty
(particularly if caused by ferromagnetic
metal shavings) using soapsuds (at
max 60%).
4. lnbetriebnahme
1.
Zylinder in die
Endlage
fahren.
2.
Druckluft
2 bar bis max. 8 bar am
AnschluB
0
anlegen.
3. Ausgang
@fur
weitere
Signalverarbeitung.
Beispiel: Eingang
“X”
Ablaufsteuerung,
Festo Quickstepper.
4. Naherungsschalter verschieben, bis
Schaltpunkt erreicht ist (Druckluftsignal am
AnschluB
(A) des
Verstarkers);
dann einige
Millimeter weiter in die
gleiche
Ftichtung,
bis er
zuruckschaltet.
5.
Neherungsschalter
mit dem Gewindestift
des Befestigungsbausatzes auf der
halben
Strecke zwischen Ein- und Ausschaltpunkt
befestigen.
5. Betrieb
a)
Urn
die Beeinflussung durch ein benach-
bartes Magnetfeldzu
minimieren,
muf3
ein
moglichst
weiter Sicherheitsabstand
zwischen zwei Zylinderrohren oder zum
Naherungsschalter eingehalten
werden.
b) Den Abstand der Schalter zu
ferromagneti-
schen
Gegenstanden
moglichst
grot3
wahlen.
c) Der
Anschluf3
@
darf
nicht
verschlossen
werden.
6. Wartung und Pflege
0
Naherungsschalter
bei
Verschmutzung
(insbesondere durch ferromagnetische
Metallsp&re)
mit Seifenlauge (max.
+6O’C)
reinigen
FESTO
PNEUMAX
FESTO AG 8Co.
.
Postfach
.
D-73726 Esslingen
.
Telefon
0711/347-
0

Popular Switch manuals by other brands

Jasco ZW4008 manual

Jasco

Jasco ZW4008 manual

Longshine LCS-883R-SW802 user manual

Longshine

Longshine LCS-883R-SW802 user manual

Seebo MAXX Setup guide

Seebo

Seebo MAXX Setup guide

ZKTeco AP100 Series quick start guide

ZKTeco

ZKTeco AP100 Series quick start guide

Gefen DVI-4X1 user manual

Gefen

Gefen DVI-4X1 user manual

Vimar NEVE UP 09592 manual

Vimar

Vimar NEVE UP 09592 manual

LevelOne OfficeCon GSW-2440 user manual

LevelOne

LevelOne OfficeCon GSW-2440 user manual

Nat ASM73 Installation and operation manual

Nat

Nat ASM73 Installation and operation manual

Simon 82 Nature Series quick start guide

Simon

Simon 82 Nature Series quick start guide

Graco 557752 instructions

Graco

Graco 557752 instructions

Network Technologies ST-nXm-U Installation and operation manual

Network Technologies

Network Technologies ST-nXm-U Installation and operation manual

Nortel 5399 quick start guide

Nortel

Nortel 5399 quick start guide

3Com Switch 7754 installation guide

3Com

3Com Switch 7754 installation guide

Vimar Eikon TACTIL 21134 manual

Vimar

Vimar Eikon TACTIL 21134 manual

Primewire 302523/20191008SZ114 user manual

Primewire

Primewire 302523/20191008SZ114 user manual

MMT 230 Series instruction manual

MMT

MMT 230 Series instruction manual

StarTech.com 5G4AINDRM-USB-A-HUB quick start guide

StarTech.com

StarTech.com 5G4AINDRM-USB-A-HUB quick start guide

Vemmio DS-100 owner's manual

Vemmio

Vemmio DS-100 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.