Ffeuk 3171MR User manual

Weatherproof Vibration Switch
Types 3171MR and 3171S
Installation and Operating
Man al
EN
1. Introdu tion
The type 3171 is a low-cost, vibration-sensitive, safety switch for the protection of rotating and
reciprocating machinery. It is adjusted to operate above the machine's normal running levels of
vibration, activating machine shut-down circuits and/or alarms and to switch off the machine
before catastrophic failure.
The switch detects vibration in all directions. Unbalanced forces created by failing machinery
contain both the fundamental frequency and harmonics. The switch responds by shutting off the
machine if any components of vibration exceed the set value.
The switch operates as follows:
• Mounted vertically on a vibrating machine, a steel ball is held by a permanent magnet into
a conical seat
• If the vibration of the machine is sufficient to cause the ball to detach from the magnetic
field of the magnet, it trips a latched lever, thus releasing a micro switch plunger so the
machine can be stopped
• In type 3171MR, the ball and lever are latched by pressing the reset button manually
• In type 3171S, the ball and lever are latched by actuating a solenoid remotely, using an
electrical signal or by pressing the reset button manually
• The SET LEVEL of the vibration switch is set by adjusting the gap between permanent
magnet and ball.
Consult the FFE website at www.ffeuk.com for the latest information on applications and any
new warnings that may affect installation or safety.

2
2. Warnings and Cautions
Read all Warnings and Cautions before Installation and Set-up.
2.1 Warnings
2.2 Cautions
WARNING !
• Risk of electric shock
3. Me hani al Installation
3.1 Introdu tion
The following tools will be needed:
• 3mm hexagon key for lid screws
• 4mm hexagon key to adjust SET LEVEL
• Wire strippers and wire cutters
• 3mm flat blade torque screwdriver for terminal block electrical connections
• 5mm flat blade torque screwdriver for internal protective earth terminal
• Adjustable spanner to fit cable gland
• For electrical safety, the vibration switch must be earthed
• For your own safety, disconnect all electrical power to the vibrating machine and ensure the
vibrating machine cannot operate during installation. Follow all safety warnings of the
machine manufacturer
• For 3171S models, if the solenoid circuit is powered from a separate supply that is not
automatically disconnected by the machine isolation device, then regulations require that
the solenoid supply have its own isolation device and also must be identified both at the
isolation device and vibration switch. The solenoid supply must be fused at a maximum of
5A.
• Installation of the vibration switch shall only be carried out by qualified personnel
• Remove vibration switch from carton
• Vibration switch is factory set to 3 g, unless a preset switch has been ordered
• To reduce the risk of damaging internal components and wiring, installation and wiring must
be performed within a temperature range of -10°C to +50°C
• Do not allow moisture or other airborne contaminants inside the switch as they can cause
corrosion
• When closing the lid, ensure the seal is not lost or damaged.
• To avoid corrosion inside the vibration switch keep enclosure sealed before and after
installation
• The Cable Entry Cap is for transport and storage and is not suitable for resisting ingress of
moisture if a vibration switch is installed in the field and not wired. Unless the switch is
immediately wired using a suitable cable gland, replace the Cable Entry Cap with Blanking
Plug 0051-002-01 (see accessories).

3
3.2 Me hani al Installation Details
The vibration switch must be fitted on the machine structure so that good transmission is
ensured from the likely source of excess vibration.
The vibration switch shall be firmly fixed in the vertical orientation shown in figure 1 to a vertical
surface of the vibrating machine using M5 fixings suitably resistant to vibration.
Figure 1: Mechanical in tallation to the urface of the vibrating machine
VERTICAL
124
51
Set Level Cap Transport
Plug
M5 fixings
in the two
places
M5 fixings
in the two
places
Cable
Entry
Cap
Switch
Rating
Label
4. Ele tri al Installation
4.1 Introdu tion
• Do not exceed the switch contact ratings. The primary switching circuit is rated at 5 Amp
maximum and must be fused appropriately in line with the protected machine’s mains
supply and isolation device
• The DC-operated solenoid has a duty cycle of 25%. It is advised that a time limiter or
mono-stable device be fitted in line to automatically disconnect the solenoid supply after 30
seconds
• When connection is by a cord, the Earth wire connection must be longer than the Live and
Neutral wires, such that failure of the strain relief will cause the Earth wire to be the last
conductor interrupted
• To prevent water running down onto the vibration switch, add a ‘drip loop’ in any external
cabling
• For ambient temperatures below –10°C, use external wiring rated for the minimum ambient
temperature expected

4
x4 3mm hex
4.2 Ele tri al Installation - Details
• To avoid breaking the lid hinge, DO NOT push on the lid when fully open.
Figure 3: Electrical In tallation
Tie-wrap wires to protect against vibration and using cable ties rated for expected ambient
temperature.
Figure 2: Before In tallation

5
Figure 4: Wiring Configuration
Swit hes are shown in their reset state.
x4
3mm hex
1Nm max.
Check lever moves freely up and down.
Figure 5

6
Remove SET
LEVEL CAP.
With machine running,
reset switch.
Tripped ?
Tripped ?
Is an increase in
sensitivity required ?
Switch is set.
Retract SET LEVEL SCREW
steadily until tripped, then
advance 1/2 turn.
Y
Y
Y
N
N
N
Advance SET LEVEL SCREW
steadily 1/2 turn.
Reset switch.
Reset Machine.
5. Set-up Sequen e
No adjustment is needed if the vibration switch has been ordered preset for your application.
Otherwise, the vibration switch is factory set accurately to 3g. For set up in the field, adjust SET
LEVEL so that the switch no longer trips in normal running with reasonable sensitivity to
excesssive vibration as follows:

7
The SET LEVEL can be estimated by referring to the calibration curve in figure 6 and counting
the number of turns from the factory setting.
If the factory setting is lost, it can be approximated as 11.5 turns from flush.
Figure 6: Vibration Switch Calibration Curve.
FLUSH

8
8. A essories
Part Number Des ription Pi ture
1000-026 LID ASSEMBLY - TYPE MR
1000-028 LID ASSEMBLY - TYPE S
G003 GLAND M20 TRS C I P
S171 SEAL 400-024449041
1000-027 4MM HEX DRIVER LONG
0051-002-01 BLAN ING PLUG IP66/67
23640-083 ADAPTOR 20mm MALE
Document Number: 0044-060-02-EN
6. Fun tional Test
To check correct set-up of the vibration switch, repeat set-up sequence section 5.
7. Maintenan e
There are no user serviceable parts inside the vibration switch. Maintenance is not required
except for periodic external visual inspection of the following:
• Confirm lid screws and vibration switch M5 fixings to machine are tight
• Confirm cable gland is tight to the enclosure and adequately secures the cable
• Confirm security of wires to external earth stud, where used
• Visually check vibration switch supply cable is installed as per local regulations and
undamaged
This manual suits for next models
1
Table of contents
Popular Switch manuals by other brands

LQ GROUP
LQ GROUP 1162723-00000 instruction manual

ZyXEL Communications
ZyXEL Communications Dimension ES-3124 brochure

Atlona
Atlona AT-DRC444 user manual

Microsemi
Microsemi PDS-104G user guide

ADTRAN
ADTRAN NETVANTA 1224 POWER OVER ETHERNET Series quick start guide

Brocade Communications Systems
Brocade Communications Systems SilkWorm 3800 Brochure & specs

Genie
Genie IP24GESP2 user manual

Omnitron Systems
Omnitron Systems RuggedNet 10GPoE+/Mi quick start guide

Steren
Steren V0310 instruction manual

Brocade Communications Systems
Brocade Communications Systems X6-4 Hardware installation guide

Wise
Wise P980 Series manual

Patton electronics
Patton electronics 360 user manual