Fiilex Q500 User manual


What Is In The Box
Specifications
Basic Operation
Rear Panel Interface Operation
Accessories Overview
Specifications
For Your Safety
1
2
3
4
5
6
6
Table of Contents

What Is In The Box
•
Cable Tie
•
4 Leaf Barndoor
•
5-Inch Fresnel Lens
•Q500 Light
1
•
PowerCon Cable

2
Parts Diagram
Vent Holes
Top Latch
Size 3 Accessory Holder
Magnetic Mount
Light Source
Focusing Knob
Junior Pin Reciever
Stand Locking Pin
Yoke
Tilt Lock Lever
Handles
DMX Address Knob
LCD Display
Yoke Bolt
CCT Tuning Knob
HUE Tuning Knob
DMX Output
(XLR Female 5-Pin)-
USB Port (Mini USB)
PowerCon Connection Port
On/Off Button
DMX Input (XLR Male 5-Pin)-
Intensity Contro l K nob
R 45J Ports (DMX In/Out)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
2
3
1
11
4
5
6
7
10
9
8
1213
14
15
18
23
16
17
19
20
21
22

Basic Operation
3
•
Turning The Light On
•
•
Adjusting Beam Angle
Adjust the beam angle by turning the Focusing Knob (6). The lens tube will extrude
back and forth from the lamphead housing.
•
•
•
USB Interface
Insert the PowerCon cable into the PowerCon Connection Port (19) and rotate
clockwise to lock in place.
Plug the light in to an appropriate outlet. The On/Off Button (20) will light red to
signify it is in stand-by mode.
Press the On/Off Button (20) to turn on the light.
The On/Off Button (20) will light green to signify it is in working mode
Positioning The Q500
To adjust the Q500, grasp the Handles (11) then loosen the Tilt Lock Lever (10).
Adjust the angle to the desired position then tighten the Tilt Lock Lever (10) to
secure.
Mounting The Q500
In order to mount the light, insert the stud of the C-Stand into the Junior Pin
Receiver (7) and secure by tightening the Stand LockingPin (8).
When mounting in a hanging position, secure the
light with a Safety Cable (Not Included).
DMX Interface
The Q500 is equipped with two DMX interfaces. RJ45 (23) or XLR ports (21 &17)
are used to send the DMX signal to the lamphead. Both interfaces include in/out
ports for the purpose of daisy-chaining the DMX line through to the next lamphead.
The Q500 is equipped with a mini USB port for updating the Q500's firmware.
Please register your product at www.fiilex.com to be informed when firmware
updates are available.
The Q500 can be mounted in a standing or hanging position with the Junior Pin
Receiver (7).

Rear Panel Interface Operation
4
KNOB
CCT
PWR
HUE
DMX
RANGE
2 00K~6500K8
100%-5%
± .25 Magenta / Green
0 ~ 512
FUNCTION
Set color temperature
Set intensity
Set HUE value
Set DMX address
HOW TO ASSIGN DMX ADDRESS:
1. Double click the DMX Address Knob (12) to activate the DMX Address Section of the LCD
Display. Once activated, a blinking line will appear below the DMX Display Area.
2. Rotate the DMX Address Knob (12) until desired address appears.
3. Once desired address is selected, click the DMX Address Knob to set the address. The new
selected address will automatically be set after 3 seconds of inactivity.
5.
4. When a DMX Address is set, the line will stop blinking.
Flashing underscore
Once a DMX address is selected the Q500 will automatically assign the next two
addresses.The Q500 assigns the addresses in this order:
(1) Intensity (2) CCT (3) Hue

Accessories Overview
5
The Q500 is equipped with two ways of attaching accessories: Magnetic Mount (4) and
Size 3 Accessory Holder (3).
See website for additional accessories. www.fiilex.com
MAGNETIC MOUNT (4)
SIZE 3 ACCESSORY HOLDER (3)
Size 3 accessories are designed to attach to the Q500 by sliding into the Size3
Accessory Holder (3) from the top side and then secured with the Top Latch (2).
Two magnets are located on the outer diameter of
the Light Source (5). Fiilex Magnetic Accessories
will mount onto the Q500 when the 5-inch Fresnel
Lens has been removed. Not all accessories are
designed to handle the intense output of the Q500.
Do Not use the Magnetic Gel Holder with the Q500.

Beam Angle
Lens Diameter
Mounting
Tilt Angle
Control
Mini USB Interface
Housing Colors
Protection Class
Estimated LED Lifetime (L70)
Certifications
50,000 hours
IP20
Black
For firmware upgrades
130mm / 5 inch
27°-50° (With Fresnel Lens)
DMX, 512 Addresses, XLR5, RJ45
+/- 90°
Baby Stud 5/8" Female (16mm) and Junior Stud 1-1/8" Male (28mm)
CE, UL, FCC
Size (without Barndoor)
Weight (Includes Yoke)
LED
Thermal Design
CCT Range
CRI
Power Consumption
Power Connection
Input Voltage
Operating Temperature 32-104ºF / 0-40º C (over temperature protection)
Dense Matrix LED
2800-6500K Continuous Tuning
>93 (3000-5600k)
185W Max
Detachable PowerCon Cable
AC Power: 100-240 VAC, 50~60Hz, Max 185W
Advanced Vapor Cooling
12 lbs / 5.5 kg
305mm X 325mm x 380mm With yoke( )
6
Specifications
For Your Safety
•CAUTION! High Beam Intensity! - Do not look into the Light Source (5) of the fixture.
•Do NOT point the light at combustable or flammable materials.
•Do NOT attempt to disassemble the body of Q500. Doing so will void the warranty.
•Do NOT install Q500 in a damp or wet area.
•Do NOT cover/block the side and back air vents.
•Use only the included power supply. Failure to do so may cause damage to the light.
•Use only a soft, dry towel to gently clean the exterior of the light.
•Do NOT lift or suspend the light by the power cable.
•Do NOT use the Q500 or accessories if they display any physical damage.
•Before first use, make sure to remove all protective membranes.
•Do NOT use the gel holder designed for the P series of lights with the Q500.
•Do NOT mount the Q500 in a hanging position without a separate safety cable.
A safety cable is NOT included with the Q500.

7
Any product, unit, or part returned to Fiilex must be packaged ina suitable
manner to ensure the protection of such product, unit, or part. The package must
be clearly and prominently marked with a Return Authorization Number (RA#) to
indicate that the package contains returned products, units, or parts. All returned
products, units, or parts must be accompanied by a written explanation of the
alleged problem or malfunction.
Information and Specifications in this document are subject to change without notice. DiCon Lightin g, Inc. assumes no responsibility or liability
for any error or inaccuracies that may appear in this manual. Unlawful reproduction or distribution in any manner without the written
permission of DiCon Lighting, is strictly prohibited.
© DiCon Lighting 1996-2014 All Rights Reserved
Fiilex.com
1689 Regatta Blvd., Richmond, CA 94804
(510)-620-5155 | fiilex@fiilex.com

Other manuals for Q500
2
Table of contents
Other Fiilex Floodlight manuals
Popular Floodlight manuals by other brands

mbt Lighting
mbt Lighting PARDL56RGBAW user manual

Blizzard Lighting
Blizzard Lighting puck Q12 user guide

Elinchrom
Elinchrom ScanLight Halogen - 20998 user manual

Colorlight
Colorlight CL20 Series user manual

Eterna
Eterna LEDFL3062 Safety and installation instructions

STARVILLE
STARVILLE LED Flood Panel 150 user manual