Page 1
OWNER’S MANUAL
High-Flo
Gold Series
12 Volt
Diaphragm Pump
Model: 5277982/5275088
www.fimcoindustries.com
1000 FIMCO Lane, P.O. Box 1700, North Sioux City, SD 57049
Toll Free Phone: 800-831-0027 : Toll Free Fax: 800-494-0440
[5008371 (04/18)]
Installaon and Service Informaon
Fimco High-Flo Gold Series pumps are designed to pump water and aqueous solutions of common pesticides. They are not
designed to pump petroleum products or other flammable materials. They are not designed to pump bleach solutions. Use of this
pump for petroleum products or bleach solutions will void the warranty. When pumping liquids other than water, the pump
should be flushed out with clean water after each use to prolong pump life.
High-Flo Gold Series pumps are equipped with a demand switch that reacts to outlet pressure and shuts the pump motor off at a
factory set pressure limit of 45 PSI. When the pressure drops below this preset limit the switch allows the pump motor to start again.
High-Flo Gold Series pumps are self-priming. Vertical prime will depend on the viscosity of the liquid and suction line size. Minimum
recommended suction line size is 3/8 inch. All hose connections need to be tight or air leakage will break the prime and disrupt water
flow. The installation of a 50 mesh strainer is recommended to prevent debris or other foreign material from entering the pump and
causing pump failure. The pump should be mounted in a dry and adequately ventilated area. The pump can be mounted horizontally
or vertically. If mounted vertically, the pump head should be down and the motor should be up. Your pump will come with adapters
which will allow you to hook up to various plumbing configurations. These fittings push into the ports of the pump and a slide mecha-
nism ‘locks’ them into place. Use flexible hose or tubing to connect to the inlet and outlet ports on the pump. This minimizes stress on
the pump head. Never use rigid pipe connections. Do not compress the feet. Overtightening will reduce the
ability to isolate vibration & noise.
Your pump is rated at 3.8 GPM @ open flow. If the discharge
plumbing is very restrictive or nozzle tips are undersized, the
back pressure will cause the pump to cycle rapidly. This rapid
cycling will increase the operating temperature of the motor
and the amperage draw on the power supply. Extended use
with this cycling will cause premature failure of the pump.
Your pump is designed to run off of the battery of your ATV,
lawn tractor, or other vehicle with a 12V system. If using a
stand alone battery, use a deep cycle RV or marine battery.
The pump should be winterized before storage, by pumping a
solution of RV antifreeze through it, and the entire plumbing
system.
Warranty:
Your Fimco High-Flo Gold Series pump is warranted for
one year from date of purchase for homeowner use & 90
days for commercial use, against manufacturer or work-
manship defects. Warranty claims will be processed by
Fimco Industries after the item is returned, freight prepaid,
to the Fimco Industries facility.
Pump must be flushed of all chemicals prior to returning to
Fimco. Fimco Industries assumes no liabilities for any
unwarranted equipment. Any unauthorized modifications/
alterations of the returned product will void your warranty.
All items must be returned within 30 days of failure. Ex-
penses, inconveniences, loss of chemicals, or other dam-
ages that occur, are not subject to warranty consideration.
Page 2
DO
 Clean and rinse your pump after each use with Fimco Tank
Neutralizer
 Winterize your pump or sprayer by rinsing, draining and
running RV Antifreeze through it before storing for the winter.
 Use clean water for your spray mixture
 Store inside a building when not in use.
DON’T
 Use to pump bleach.
 Use to pump petroleum products such as diesel fuel,
gasoline or kerosene
 Leave your pump sit with spray mixture in it for extended
periods
 Use dirty or unfiltered water for spraying
Troubleshooting the Pump:
Motor does not run:
 Check for loose wiring connection(s).
 Make sure the 'ON/OFF' switch in the lead wire assembly is
in the 'ON' position. "I" is the 'ON' position and 'O' is the 'OFF'
position.
 Check for defective pressure switch. Make sure you are con-
nected to a good 12 volt power source. Make sure any on/
off switches are in the 'on' position. Remove the cap to the
pressure switch. Pull both red wires off of their terminals, and
touch the two ends together. If your pump runs when you do
this, your pressure switch will need to be replaced.
 Check the fuse.
 Check for low voltage at the power supply.
Pump does not prime:
 Check for air leaks in supply line.
 Check for debris in the check valve assembly.
 Check for defective check valve.
 Check for clogged strainer/filter.
 Check for cracks in the pump housing.
 Check for empty product supply.
Pulsating flow (surging):
 Check for defective pressure switch.
 Check for leaks in the discharge line.
 Check for restriction in the discharge line.
 Check for debris in nozzle orifice.
 Discharge hose may be too long.
 Check for clogged strainer.
Motor continues to run after discharge is shut off:
 Check for empty product supply.
 Check for open bypass valve. (if equipped)
 Check for low voltage.
 Check for leak in discharge line.
 Check for defective or dirty check valve.
 Check for defective pressure switch.
GPM=Gallons Per Minute
PSI=Pounds per Square Inch
DC=Direct Current
Wetted Parts Housing:
Polypropylene
Diaphragm:
Santoprene
Liquid Temperature:
130° F max.
Pump Specifications
Current:
7.4 Amps @ 40 PSI
Check Valve:
Viton
Pump Model: 5277982
Available Replacement Parts
Replacement Pump: 5275088
Includes: 1/2” MNPT Port Kit Fitting #5168832
1/2” Hose Barb Port Kit Fitting #5168833
Page 3
Checking the Pressure Switch:
If your motor is not running and you’ve checked the following: for loose wiring connections, fuse, the
switch on the lead wire was “ON” and made sure you were connected to a fully charged battery and
everything is fine, but the motor won’t run, then it’s time to check to see if the pressure switch is bad.
 Remove the cover off the 1” square box (pressure switch) on the head of the pump, the cover is
held on by one phillips-head screw. This will expose the two red wires.
 With the pump connected to a good 12 volt power source and everything on.
 Slip the two red wires off the terminals and touch them together.
If the motor runs, it means the pressure switch is bad and needs to be replaced.
If it still doesn’t run, try bypassing the switch in the lead wire or using another lead wire. Even if a
tester shows power to the pressure switch, it still could be the switch in the wire that is causing the
problem. If still not responsive, use a voltmeter or electrical tester to make sure you are getting power
to the head of the pump, as it could possibly be something in one of the wires or even the lead wire
assembly may need to be replaced.
Warning: It is NOT recommended to run the pump this way, as the pump will continue to run and not
shut off.
This could result in blown hoses when all discharges are closed. Also, this could result in premature
failure of the pump completely.
Cleaning the Check Valve:
If you’re experiencing little to no pressure or the pump is not priming and you’ve checked your filter
screen and it’s clean, you may need to clean the check valve.
 Remove the head of the pump, which is held on by about 6-7 screws.
 The first piece inside the head of the pump is called a check valve, it’s the part responsible for building up pressure and
pumping water/solution through the lines.
 Clean the check valve under hot, soapy water (such as a good grade dish soap).
 Give it a very light scrubbing with something like an old toothbrush, something with soft bristles.
 Then let it soak for about an hour or so in the hot soapy solution and replace in the pump and reassemble the
pump.
Most times this will restore most, if not all of the prime of a pump.
Try another 12-Volt battery
Quarter turn at a time clockwise until surging stops
Check that shut-off valve on inlet (if applicable) is open
Troubleshooting
Pump will not run:
Check for loose wiring
Make sure the ON/OFF switch is on
Check the fuse
Check for defective pressure switch
Low Pressure/Low Flow:
Check for a clogged strainer
Check for proper voltage
Check for worn or dirty check valve
Pump surges:
Low flow may cause pump to surge
Spray wand is adjusted for a small or fine spray pattern
Slightly open bypass (if applicable) to overcome
If needed, pressure switch may need to be adjusted
Pump continues to run:
Bypass (if applicable) is not completely closed
System has leaks
Check for worn or dirty check valve
Fuse blows:
Excessive voltage
Improper adjustment of pressure switch
Damaged or defective wiring harness
Defective pressure switch
Page 4
LIMITED WARRANTY FOR NEW FIMCO, IND. EQUIPMENT
WHO MAY USE THIS LIMITED WARRANTY. This limited warranty (the “Limited Warranty”) is provided by Fimco, Ind. to the original purchaser
(“you”) of the Equipment (as dened below) from Fimco, Ind. or one of Fimco, Ind.’s authorized dealers. This Limited Warranty does not apply to
any subsequent owner or other transferee of the Equipment. THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO
HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
WHAT THIS LIMITED WARRANTY COVERS AND FOR HOW LONG. Fimco, Ind. warrants that any new Equipment will be free from defects in
material and workmanship for a period of one (1) year (homeowner), 90 days (commercial user), aer delivery of the Equipment to you (the
“Warranty Period”). The Warranty Period is not extended if Fimco, Ind. repairs or replaces the Equipment.
WHAT IS NOT COVERED BY THIS LIMITED WARRANTY. This Limited Warranty does not apply to: (1) used Equipment; (2) any Equipment that has
been altered, changed, repaired or treated since its delivery to you, other than by Fimco, Ind. or its authorized dealers; (3) damage or deprecia-
on due to normal wear and tear; (4) defects or damage due to failure to follow Fimco, Ind.’s operator’s manual, specicaons or other wrien
instrucons, or improper storage, operaon, maintenance, applicaon or installaon of parts; (5) defects or damage due to misuse, accident or
neglect, “acts of God” or other events beyond Fimco, Ind.’s reasonable control; (6) accessories, aachments, tools or parts that were not manu-
factured by Fimco, Ind., whether or not sold or operated with the Equipment; or (7) rubber parts, such as res, hoses and grommets.
HOW TO OBTAIN WARRANTY SERVICE. To obtain warranty service under this Limited Warranty, you must (1) provide wrien noce to Fimco,
Ind. of the defect during the Warranty Period and within thirty (30) days aer the defect becomes apparent or the repair becomes necessary, at
the following address: Fimco, Ind., 800 Stevens Port Drive, Suite DD836, Dakota Dunes,SD 57049; and (2) make the Equipment available to Fimco,
Ind. or an authorized dealer within a reasonable period of me. For more informaon about this Limited Warranty, please call: 800-831-0027.
WHAT REMEDIES ARE AVAILABLE UNDER THIS LIMITED WARRANTY. If the condions set forth above are fullled and the Equipment or any part
thereof is found to be defecve, Fimco, Ind. shall, at its own cost, and at its opon, either repair or replace the defecve Equipment or part.
Fimco, Ind. will pay for shipping and handling fees to return the repaired or replacement Equipment or part to you.
LIMITATION OF IMPLIED WARRANTIES AND OTHER REMEDIES. THE REMEDIES DESCRIBED ABOVE ARE YOUR SOLE AND EXCLUSIVE REMEDIES,
AND FIMCO, IND.’S SOLE LIABILITY, FOR ANY BREACH OF THIS LIMITED WARRANTY. TO THE EXTENT APPLICABLE, ANY IMPLIED WARRANTIES,
INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL BE LIM-
ITED IN DURATION TO THE WARRANTY PERIOD, AND THE REMEDIES AVAILABLE FOR BREACH THEREOF SHALL BE LIMITED TO THE REMEDIES
AVAILABLE UNDER THIS EXPRESS LIMITED WARRANTY. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY
LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. IN NO EVENT SHALL FIMCO, IND.’S LIABILITY UNDER THIS LIMITED WARRANTY EX-
CEED THE ACTUAL AMOUNT PAID BY YOU FOR THE DEFECTIVE EQUIPMENT, NOR SHALL FIMCO, IND. BE LIABLE, UNDER ANY CIRCUMSTANCES,
FOR ANY CONSEQUENTIAL, INCIDENTAL, SPECIAL OR PUNITIVE DAMAGES OR LOSSES, WHETHER DIRECT OR INDIRECT. SOME STATES DO NOT
ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT
APPLY TO YOU.
Warranty

This manual suits for next models

2

Other Fimco Water Pump manuals

Fimco HIGH-FLO HFP-12060-111 User manual

Fimco

Fimco HIGH-FLO HFP-12060-111 User manual

Fimco HIGH-FLO PRO Series User manual

Fimco

Fimco HIGH-FLO PRO Series User manual

Fimco LAWN GUARD 7772105 User manual

Fimco

Fimco LAWN GUARD 7772105 User manual

Fimco HIGH-FLO HFP-24060-113 User manual

Fimco

Fimco HIGH-FLO HFP-24060-113 User manual

Fimco 300-3PT-1PC-TSC User manual

Fimco

Fimco 300-3PT-1PC-TSC User manual

Fimco High-Flo HFP-45060-113 User manual

Fimco

Fimco High-Flo HFP-45060-113 User manual

Fimco HIGH-FLO HFP-24000-214 User manual

Fimco

Fimco HIGH-FLO HFP-24000-214 User manual

Popular Water Pump manuals by other brands

Watershed Innovations HYDRAPUMP SMART FLEX Instructional manual

Watershed Innovations

Watershed Innovations HYDRAPUMP SMART FLEX Instructional manual

Graco Modu-Flo AL-5M instructions

Graco

Graco Modu-Flo AL-5M instructions

Messner MultiSystem MPF 3000 operating instructions

Messner

Messner MultiSystem MPF 3000 operating instructions

Xylem Bell & Gossett WEHT0311M Installation, operation and maintenance instructions

Xylem

Xylem Bell & Gossett WEHT0311M Installation, operation and maintenance instructions

WilTec 50739 Operation manual

WilTec

WilTec 50739 Operation manual

Franklin Electric Little Giant 555702 HRK-360S instruction sheet

Franklin Electric

Franklin Electric Little Giant 555702 HRK-360S instruction sheet

Ingersoll-Rand PD02P Series Operator's manual

Ingersoll-Rand

Ingersoll-Rand PD02P Series Operator's manual

VS ZJ Series Operating	 instruction

VS

VS ZJ Series Operating instruction

Flotec FPZS50RP owner's manual

Flotec

Flotec FPZS50RP owner's manual

SKF Lincoln FlowMaster II User and maintenance instructions

SKF

SKF Lincoln FlowMaster II User and maintenance instructions

Xylem Lowara LSB Series Installation, operation and maintenance instructions

Xylem

Xylem Lowara LSB Series Installation, operation and maintenance instructions

Water Duro Pumps DCJ500 Operating & installation instructions

Water

Water Duro Pumps DCJ500 Operating & installation instructions

Action P490 Operating instructions & parts manual

Action

Action P490 Operating instructions & parts manual

Flo King Permacore Reusable Carbon Bag Disassembly. & Cleaning Instructions

Flo King

Flo King Permacore Reusable Carbon Bag Disassembly. & Cleaning Instructions

ARO ARO PD15P-X Operator's manual

ARO

ARO ARO PD15P-X Operator's manual

Pumptec 112V Series Operating instructions and parts manual

Pumptec

Pumptec 112V Series Operating instructions and parts manual

Virax 262070 user manual

Virax

Virax 262070 user manual

Neptun NPHW 5500 operating instructions

Neptun

Neptun NPHW 5500 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.