Finsecur CAP 200 A User manual

Installation and operation manual
01_DETAD_NT005 rév A1
CAP 200 A
Adressable heat detector
FINSÉCUR
52 rue Paul Lescop
92000 NANTERRE
T. +33 01 41 37 91 91
F. +33 01 41 37 92 91
finsecur@finsecur.com
www.finsecur.com
CAP 200 A
52, rue Paul Lescop
92000 NANTERRE
t. +33 (0)1 41 37 91 91
f. +33 (0)1 41 37 92 01
finsecur@finsecur.com
www.finsecur.com
.
0333
Finsecur
52, Rue Paul lescop
92000 Nanterre
08
0333-CPR-075133
DOP : 0333-CPR-075133
Item code : DETAD200
EN 54-5
CAP200A A1 R
Adressable heat detector
Specifications : See 01.DETAD.NT005
www.marque-nf.com
Installation and operating manual
01-DETAD-NT005 rev A1
CAP 200 A
Adressable heat detector 200A
→Presentation
How the heat detector works ?
The heat detection is carried out by a thermal probe which permanently
measures the room temperature. The detector analyses the temperature
in 2 simultaneous ways :
→Comparison of the room temperature at a pre-determined thres-
hold and if this threshold is overtake, the detector moves to the
alarm mode, whatever the temperature rise’s speed. This is the
thermostatic mode.
→Computation of the temperature rise’s speed and when the tem-
perature rises according to a predetermined speed, the detector
moves to the alarm mode. This is the rate-of-rise (ROR) mode.
The temperature probe is composed of a negative temperature coef-
ficient (NTC) thermistor at low thermal inertia.
→installation
Mount the base of the detector by fixing it firmly. Connect according
the enclosed wiring diagram, respecting the polarities.
In case you lay a coating such as paint near to the detector, make sure
to protect it against any possible pollution.
Put the control panel into service and proceed to the recommended
tests in the panel user manual. In particular, operate a detection test
with an adequate device (such as a heat detector tester).
→oPeration
In case of detection, the red indicator of the detector turns on and a
signal is sent to the control panel by mean of an overconsumption of
current. The red indicator is on until the reset of the panel.
Proceed to periodical tests on the detector (at least twice a year). These
operations must be performed by a qualified company.
Terminal Name Connection
1 -IA - remote indicator
2 + S + line output
3 + E + line input
4 0 V
5 Not used
→technical characteristics
Material : moulded white ABS
Wiring base : reference S100 (item number ACCDE001)
Remote indicator output : maximum 10 mA at 24 V
Compliant EN 54-5
Supply voltage + 15 V to + 30 V continuous
Quiescent current 670 µA ± 10 µA at 24 V
Alarm current 13 mA ± 2 mA at 24 V
Remote indicator output voltage (limited at 10 mA) 15 to 30 V continuous voltage
Thermal characteristics
Rating (according to EN 54-5 : 2000) A1R
Typical implementation temperature 25°C
Maximum implementation temperature 50°C
Static temperature response 60°C
Stabilization time (until the detector is operational in ROR
mode)
3 min 20 s for the temperature rise’s speed equal or superior to 10°C per min.
40 min for the temperature rise’s speed inferior to 10°C per min.

Popular Security Sensor manuals by other brands

Bradley S19-210B Installation

Bradley

Bradley S19-210B Installation

RLE SeaHawk LDRA6 user guide

RLE

RLE SeaHawk LDRA6 user guide

Bentel FireClass FC400H manual

Bentel

Bentel FireClass FC400H manual

Niko 351-25032 manual

Niko

Niko 351-25032 manual

urmet domus 1033/013 manual

urmet domus

urmet domus 1033/013 manual

GE Choice Alert user manual

GE

GE Choice Alert user manual

Carrier HyperSense 7C-HS-C1W-X installation guide

Carrier

Carrier HyperSense 7C-HS-C1W-X installation guide

Siemens Cerberus CS1140 Planning

Siemens

Siemens Cerberus CS1140 Planning

Nivetec BULLETIN 824A Installation & operation

Nivetec

Nivetec BULLETIN 824A Installation & operation

Cisco Meraki MT12 installation guide

Cisco

Cisco Meraki MT12 installation guide

Leuze electronic CU411-RS4 Supplement to original operating instructions

Leuze electronic

Leuze electronic CU411-RS4 Supplement to original operating instructions

Sonoff SNZB-04P user manual

Sonoff

Sonoff SNZB-04P user manual

Vaxcel T0173 Assembly and installation instructions

Vaxcel

Vaxcel T0173 Assembly and installation instructions

UTC Fire and Security Interlogix DDV1016 Installation sheet

UTC Fire and Security

UTC Fire and Security Interlogix DDV1016 Installation sheet

Triplett ET30 user manual

Triplett

Triplett ET30 user manual

Eaton xComfort CBMA-02/01 Instruction leaflet

Eaton

Eaton xComfort CBMA-02/01 Instruction leaflet

AVE AF974R-DB manual

AVE

AVE AF974R-DB manual

LEGRAND Mallia Senses with Netatmo 2 815 02DS/MB/MW Quick installation instructions

LEGRAND

LEGRAND Mallia Senses with Netatmo 2 815 02DS/MB/MW Quick installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.