Assemble ALL ALARMS as per points 1 & 2 before moving to point 3
Note the 10 SECOND WINDOW at point 3.7. If you miss this 10 second window,
you will need to reset all alarms and start again
If you have diculty connecting your alarms, please watch our interlink video guide or
contact Safelincs’ customer support team.
www.safelincs.co.uk/rehawk-interlink-video-guide
PLEASE read all instructions BEFORE beginning to pair a system!
1.0 Plug alarm into pattress and switch on radio
base, the pattress led will ash green twice
per second. If not please complete step 6.0
2.0 Bring alarm & radio base together then twist/slide to lock into place.
3.1 Place two alarms on the table spaced approximately
20cm APART.
3.2 Press the TEST BUTTON on one alarm and wait
THREE SECONDS.
3.3 Press the TEST BUTTON on the other alarm.
3.4 Watch carefully as both pattresses FLASH GREEN
AND RED
3.5 As soon as one FLASHES GREEN ONLY, move it to one side.
3.6 The other pattress will continue to ash red/green until it BEEPS ,then it will FLASH GREEN
(The CO will BEEP FOUR TIMES) THE TWO ALARMS ARE NOW PAIRED.
3.7 There is now a 10 SECOND WINDOW to allow another device to be added to the system Step 4.0
If no other devices are to be added proceed to Step 5.0
(Repeat steps 1.0 and 2.0 for each alarm)
Wait for smoke or heat alarm to BEEP TWICE Wait for the CO alarm to BEEP FOUR TIMES
1CONNECT
!PLEASE NOTE
2ALARM ASSEMBLY
3PAIRING TWO ALARMS
SMOKE ALARM FHB10W HEAT ALARM FHH10W CO ALARM CO7B (10Y)W
PAIRED
PRESS
& WAIT
FOR 3
SECS.
3.1 3.2 3.3 3.4 3.5
3.2 3.3
PAIRED
20cm
UNPAIRED
ALARM(S)
Pairing Radio Linked Alarms Instructions