Flepcher FLP-MA120U User manual

The FLP-MA120U and MA240U are the latest addition to the MA Series that are versatile and suitable to be deployed in
various PA system. It comes with 5 zones speaker terminals which can be selected individually. The series comes with three
balance microphone inputs, two aux inputs and one EMC input providing more functionality to the PA system. The EMC
input is capable in overriding BGM and able to mute various channels except Mic 1 when it comes to emergency and crucial
situations. With noticeable function buttons and fluorescent screens, users are able to control and navigate the PA system
much more eciently and eectively.
FLP-MA-120U / MA-240U
5 Zone Mixer Amplifier
• With USB port and fluorescent screen to display the sound number
• Remote control over USB for EQ, volume up, volume down & mute
• 5 zone and all zone speaker terminals
• Mic 1 with VOX priority and VOX level on rear panel
• Mic 2-3 by phone jack rear on rear panel
Product Features
Rated Power Output
Speaker Outputs
Output Sensitivity & Impedance
Tone
Frequency Response
S/N Ratio
THD
Muting Function
Gain Control
Crosstalk
MP3 Support Format
Maximum Support Capacity
Phantom Power
Cooling
Protection
Power Supply
Power Consumption
Weight
Dimensions (W x D x H)
Finish
Specifications
70V, 100V & 4~16Ω
MIX OUT: 1000mV/470Ω, Unbalanced RCA output
Bass: ±10dB at 100Hz, Treble: ±10dB at 10KHz
50Hz~16KHz( +1dB, -3dB)
MIC 1, 2, 3: 66dB, AUX 1, 2: 80dB
Less than 0.1% at 1KHz, 1/3 rated power
MIC 1 overrides other input signals with 0-30dB attenuation
MIC2, 3 XLR, ±2.5mV~±75mV at 30dB
≤50dB
MP3
8GB USB drive
+48V, with LED indicator
Fan automatically start up when temp reaches 55ºC
High temp, overload & short-circuit
~240V/50Hz & 24V DC
Panel: aluminium plate, black
Case: steel plate, black
200W
10 kg
484mm x 300mm x 88mm
FLP-MA120U
120W
400W
17.5 kg
484mm x 300mm x 88mm
FLP-MA240U
240W
Portable Sound System Mixer Amp/ Pre Amp/ Power Amp Paging Microphone
& Zone selector Rack mount equipment
Zone 1 to 5 speaker
output terminal Mic 2 & 3
input
DC 24V input
Emergency
input
Speaker output
terminal Mic 2 & 3
line input
Line output, or
to next amplifier
AUX 1 & 2
input
• Two Aux Inputs and 2 line inputs for spare use
• One EMC priority input
• EMC has priority over all inputs except MIC1
• Support DC 24V power supply
8

Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.
OPERATION MANUAL
TMTM
PROFESSIONAL PUBLIC ADDRESS SYSTEM
MIXER AMPLIFIER
SPEAKER ZONES
POWER
MIC 1
5
0
1
2
3
4 6
7
8
9
10
BASS
0
-5
-4
-3
-2
-1 +1
+2
+3
+4
+5
TREBLE
0
-5
-4
-3
-2
-1 +1
+2
+3
+4
+5
5
0
1
2
3
4 6
7
8
9
10
MIC 3 AUX 1
5
0
1
2
3
4 6
7
8
9
10
AUX 2MIC 2
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
MASTER
5
0
1
2
3
4 6
7
8
9
10
ON
OFF
2
PROTTEMP
46810 12
OUTPUT LEVEL
12 3 4 5ALL
PREV MP3 VOL
PLAY NEXT RPT
MP3 PLAYER
USB
MIC 1
010
FLP-MA120U
MIXER AMPLIFIER
FLP-MA120U
FLP-MA240U

TABLE OF CONTENTS
2
1. SAFETY PRECAUTIONS ......................................................................................3
2. GENERAL DESCRIPTION ...................................................................................5
3. FEATURES ................................................................................................................5
4. NOMENCLATURE AND FUNCTIONS
4.1 Front Panel(2U) .......................................................................................................6
4.2 Rear Panel(2U)....................................................................................................... 7
.............................................................................7
5. CONNECTIONS
5.1. Speaker Connections .............................................................................................8
5.2. ..............................................................................................8
6. ........................................................................................9
7. APPLICATIONS .....................................................................................................10
8.BLOCK DIAGRAM .................................................................................................11
9.SPECIFICATIONS .................................................................................................12
10.DIMENSIONAL DIAGRAM ................................................................................13
4.3 REMOTE CONTROL INSTRUCTIONS
XLR CONNECTIONS
MACHINE OPERATION

Be sure to read the instructions in this section carefully before use.
Make sure to observe the instructions in this manual as the conventions of safety symbols and messages
regarded as very important precautions are included.
We also recommend you keep this instruction manual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety
Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
When Installing the Unit
Do not expose the unit to rain or an environment
where it may be splashed by water or other liquids,
as doing so may result in fire or electric shock.
Use the unit only with the voltage specified on the
unit. Using a voltage higher than that which is
specified may result in fire or electric shock.
Do not cut, kink, otherwise damage nor modify the
power supply cord. In addition, avoid using the
power cord in close proximity to heaters, and never
place heavy objects -- including the unit itself -- on
the power cord, as doing so may result in fire or
electric shock.
Be sure to replace the unit's terminal cover after
connection completion. Because high voltage is
applied to the speaker terminals, never touch these
terminals to avoid electric shock.
Be sure to ground to the safety ground (earth)
terminal to avoid electric shock. Never ground to a
gas pipe as a catastrophic disaster may result.
Avoid installing or mounting the unit in unstable
locations, such as on a rickety table or a slanted
surface. Doing so may result in the unit falling
down, causing personal injury and/or property
damage.
When the Unit is in Use
Should the following irregularity be found during
use, immediately switch off the power, disconnect
the power supply plug from the AC outlet and
contact your nearest FLEPCHER dealer. Make no
further attempt to operate the unit in this condition
as this may cause fire or electric shock.
If you detect smoke or a strange smell coming
from the unit.
If water or any metallic object gets into the unit
If the unit falls, or the unit case breaks
If the power supply cord is damaged (exposure of
the core, disconnection, etc.)
If it is malfunctioning (no tone sounds.)
To prevent a fire or electric shock, never open nor
remove the unit case as there are high voltage
components inside the unit. Refer all servicing to
your nearest FLEPCHER dealer.
Do not place cups, bowls, or other containers of
liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a fire
or electric shock.
Do not insert nor drop metallic objects or
flammable materials in the ventilation slots of the
unit's cover, as this may result in fire or electric
shock.
1. SAFETY PRECAUTIONS
3

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.
When Installing the Unit
Never plug in nor remove the power supply plug
with wet hands, as doing so may cause electric
shock.
When unplugging the power supply cord, be sure
to grasp the power supply plug; never pull on the
cord itself. Operating the unit with a damaged
power supply cord may cause a fire or electric
shock.
When moving the unit, be sure to remove its power
supply cord from the wall outlet. Moving the unit
with the power cord connected to the outlet may
cause damage to the power cord, resulting in fire or
electric shock. When removing the power cord, be
sure to hold its plug to pull.
Do not block the ventilation slots in the unit's cover.
Doing so may cause heat to build up inside the unit
and result in fire.
Avoid installing the unit in humid or dusty locations,
in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock.
When the Unit is in Use
Do not place heavy objects on the unit as this may
cause it to fall or break which may result in
personal injury and/or property damage. In
addition, the object itself may fall off and cause
injury and/or damage.
Make sure that the volume control is set to
minimum position before power is switched on.
Loud noise produced at high volume when power is
switched on can impair hearing.
Do not operate the unit for an extended period of
time with the sound distorting. This is an indication
of a malfunction, which in turn can cause heat to
generate and result in a fire.
Contact your FLEPCHER dealer as to the cleaning.
If dust is allowed to accumulate in the unit over
a long period of time, a fire or damage to the unit
may result.
If dust accumulates on the power supply plug or in
the wall AC outlet, a fire may result. Clean it
periodically. In addition, insert the plug in the wall
outlet securely.
Switch off the power, and unplug the power supply
plug from the AC outlet for safety purposes when
cleaning or leaving the unit unused for 10 days or
more. Doing otherwise may cause a fire or electric
shock.
SAFETY PRECAUTIONS
4

3. FEATURES
The USB mixer amplifiers have power ratings from 120W to 240W. They are featured of 3 balanced
microphone inputs, 2 AUX inputs and 2 EMC inputs.
Priority muting is achieved via EMC1-2 for overriding other inputs except Mic1 on front panel.
Individual gain controls are provided for Mic 1-3 and Aux1-2,bass and treble controls and master volume
control are provided for overall tone control.70V,100V,and low impedance 4-16ohms speaker outputs are
provided. Extensive protection from short -circuit, overload and high temp.
2. GENERAL DESCRIPTION
=With USB port and fluorescent to display the sound number.
=Four function buttons: previous, play/stop, next and repeat.
=Remote control over USB for EQ ,volume up volume down &mute.
=Mixer amplifier for paging and background music system.
=In 2U height.
=70V,100V and low impedance 4-16ohm speaker output.
=5 zone and zone speaker terminals.
=Three Mic inputs by phone jack type.
=Mic 1 with VOX priority and VOX level on rear panel.
=Mic 2-3 by phone jack on rear panel.
=Two Aux Inputs and 2 line inputs for spare use.
=One EMC priority inputs.
=EMC 1 has priority over all inputs except MIC1.
=Mic 1-3,Aux1-2 and master volume controls and bass/treble tone control.
=High temp, overload & short-circuit protection.
5

4. NOMENCLATURE AND FUNCTIONS
4.1 FRONT PANEL(2U)
1. USB INTERFACE
MP3 Storage which can be connected
with USB interface
2. MIC1
MIC1 input 6.3 Microphone jack input
3. MIC1 \ MIC2 \ MIC3
MIC volume control
4. AUX1 \ AUX2
Aux volume control
5. BASS
Clockwise rotation to increase the output
of the bass; otherwise decrease.
6. TREBLE
Clockwise rotation to increase the output
of the treble; otherwise decrease.
7. MASTER VOLUME
All the level control of the inputs are
controled by the master volume.
8. POWER SWITCH
On top of the openin g Power
Press the end, power shut down
9
10
13
14
1516 111217
181920
12345678
9. POWER
Power indicator
10.SPEAKER ZONE(1~5)
Speaker zone(1~5) indicator
11.SPEAKER ZONE(1~5)
Speaker zone(1~5) button control
12.LEVEL INDICATORS
Level meters 6 output level indicators
13.PROT
Protection indicator
14.TEMP
Temperature indicator
15.MP3
MP3 volume control
16.Circulation play choice
17.NEXT
18.PLAY/PAUSE
Play/Pause button (Mp3)
19.LAST
20.MP3 Frame
Display the current work state
6
SPEAKER ZONES
POWER
MIC 1
5
0
1
2
3
4 6
7
8
9
10
BASS
0
-5
-4
-3
-2
-1 +1
+2
+3
+4
+5
TREBLE
0
-5
-4
-3
-2
-1 +1
+2
+3
+4
+5
5
0
1
2
3
4 6
7
8
9
10
MIC 3 AUX 1
5
0
1
2
3
4 6
7
8
9
10
AUX 2MIC 2
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
MASTER
5
0
1
2
3
4 6
7
8
9
10
ON
OFF
2
PROTTEMP
46810 12
OUTPUT LEVEL
12 3 4 5ALL
PREV MP3 VOL
PLAY NEXT RPT
MP3 PLAYER
USB
MIC 1
010
FLP-MA120U
MIXER AMPLIFIER

NOMENCLATUREAND FUCTIONSNOMENCLATUREAND FUCTIONS
4.2 REAR PANEL(2U)
21. ~240V 50Hz AC POWER INPUT
22. DC 24V input
23.
24.
25.
26.
27.
Output terminal of the speaker
Connecting 4~16 /70V/100V speaker
EMC
Alarm signal input of EMC
MUTE
Potentiometer of mute
MIC2\MIC3
Unbalanced input of mic
MIC2 LINE1 /MIC3 LINE2
Aux input of MIC2/MIC3, sensitivity:
775mV
28.
29. MIX
30. FAN
31. MIC2 MIC3 PHANTOM SWITCH
32. MIC2 MIC3 GAIN ADJUSTMENT
33.(1~5) ZONE OUTPUT TERMINAL (100V)
Connecting speakers
AUX1/AUX2
Aux input jack, un-balanced signal
connection, sensitivity: 350mV
OUT
Line output, cascade connection,
can be connect with next amplifier
21 23 24 25 26 27 28 29 30
31
33 32
7
4.3 REMOTE CONTROL INSTRUCTIONS
1. Power button
2. Play / Pause / confirm button
3. MODE
4. Number control
5. Last/Next
6. REW/Fast forward key
7. volume(+)
8. Volume(-)
9. Sound Effect Control
EMC INPUT
12
3
12
3
MUTE
COM 100V
CH1 CH2 CH3 CH4 CH5
COM 100V COM 100V
COM 100V
COM 100V
+
MIC 2
XLR
GAIN
MIC 2
+48V
PHANTOM
MIC2 MIC3
MIC 2 MIC 3
MIC 3
+48V
PHANTOM
AUX2
INPUT
MIX
OUT
AUX1
INPUT
MIC2 MIC3
LINE INPUT
MIC 3
XLR
GAIN
~240V 50Hz 200W
T3.15AL 250V
COM 4-16 70V 100V
OUTPUT
BATT SUPPLY
24V 5A
22

70V 100V
COM 4-16 70V 100V
COM 4-16
100V LINE
70V 100V
COM 4-16
70V LINE
5.1 SPEAKER CONNECTIONS
5.2 XLR CONNECTIONS
4-16
5. CONNECTIONS
70V/
(FLP-MA120U)
(FLP-MA240U)
40
20
(FLP-MA120U)
(FLP-MA240U)
83
41
8
Remote control using distance:
Using remote control distance: usually remote control distance is 8 meters, remote control
Angle: horizontal plus or minus 35 degrees, vertical plus or minus 15 degrees are effective.
Attention:
1. When installing the battery, pay attention to the positive and negative polarity of battery;
2. Aim the remote control transmitter host receives the window, please operate; When found the
remote control distance smaller and insensitive, please replace the battery;
3. Don't use the remote control for a long time, please remove the battery;
4. Light to take light put the remote control, take precautions against falling.
NOMENCLATURE AND FUNCTIONS

MIC 1 with the first priority over other inputs,
the adjustment should be kept within 0-30db
with the mute connector, 30db is the original
setting.
MUTE FUNCTION
1 Machine is in protection
condition in case of high
temperature
2 Wrong wire connection
OPERATIONATTENTION
The four output connectors only can choose two
connectors work together. If voltage is 70V/100V,
the speakers must be with transformer and make
sure the total power wattage of speaker is 15%
less than the power wattage of amplifier.
GUIDANCE OF EXCLUDING ERRORS
No voice output in
normal condition
All the wires are
connected well
but no voice output
Cause
1 No power or wrong
plug connection
2 Fuse is burned
3 Volume is town off
4 No input signal
Power on but ala-
rming signal
1 Overloading or short
circuit
2 Voltage is not stable,
too high or low
Phenomena
6. MACHINE OPERATION
9

7. APPLICATIONS
REAR PANEL CONNECTIONS
12
3
INPUTS LINK
COM 4-16 70V 100V
OUTPUT
COM COM
GND
LIFT
MIC 2
MIC 3
AUDIO
OUT
RR
LL
AUDIO
OUT
RR
LL
LOOP ANTENNAFm75
ANTENNA
AM
GND
+ ALARM IN - ALARM OUT MIC IN RECIN
10
EMC INPUT
12
3
12
3
MUTE
COM 100V
CH1 CH2 CH3 CH4 CH5
COM 100V COM 100V
COM 100V
COM 100V
+
MIC 2
XLR
GAIN
MIC 2
+48V
PHANTOM
MIC2 MIC3
MIC 2 MIC 3
MIC 3
+48V
PHANTOM
AUX2
INPUT
MIX
OUT
AUX1
INPUT
MIC2 MIC3
LINE INPUT
MIC 3
XLR
GAIN
~240V 50Hz 200W
T3.15AL 250V
COM 4-16 70V 100V
OUTPUT
BATT SUPPLY
24V 5A
ALARMING SIGNAL GENERATOR
CD PLAYER CD+TUNER PLAYER
500-WATT AMPLIFIER

100V
70V
4~16
TO
PA
BASS/TREBLE
VOLUME
PROTECT
LEVEL INDICATOR
POWER
Z ~240V 50Hz
PT
EB
MIC2
VCC
LINE1
COM
MUTE
EB
MIC3
VCC
LINE2
EB
MIC1
AUX1 EB
AUX2 EB
8. BLOCK DIAGRAM
11

9. SPECIFICATIONS
MODEL
RATED POWER OUTPUT
SPEAKER OUTPUTS
PROTECTION
TONE
INPUT
FREQUENCY RESPONSE
S/N RATIO
T.H.D
CROSSTALK
MUTING FUNCTION
CONTROLS
INDICATORS
MIXER AMPLIFIER(2U)MIXER AMPLIFIER(2U)
DIMENSION(mm)
NET WEIGHT
GROSS WEIGHT
POWER CONSUMPTION
POWER REQUIREMENTS
PHANTOM
MIC 1,2,3: 66dB;AUX 1,2:80dB
Less than 1% at 1KHz,1/3 rated power
MIC1 over other input signals with 0~30dB
attenuation
EMC 1 over all inputs except MIC 1
Individual gain controls, power switch
Power LED, LED level meter, protect
AC fuse, short-circuit and high temperature
FLP-MA120U
120W
4~16 ,70V/100V
Bass: 10dB at 100Hz
Treble: 10dB at 10KHz
50Hz~15KHz
MIC : 80dB;AUX 85dB
484X300X88
~240V 50Hz,DC 24V
10.4Kg
10Kg
200W
48V
FLP-MA240U
240W
400W
17.5Kg
18.9Kg
12
MIC 1:5mV/600 Ohms Unbalanced TRS input
MIC 2.3:5mV/600 Ohms Unbalanced TRS/XLR input
MIC2.3:LINE:775mV/10KOhms,Unbalanced RCA input
AUX 1. 2:350mV/10KOhms, Unbalanced RCA input
EMC:775mV/10KOhms, Unbalanced EMC input

100
Over
100
Over
Over
100
10. DIMENSIONAL DIAGRAM
UNIT:mm
6
84
84
25
329
321
88
94
436
484
UNIT:mm
13
SPEAKER ZONES
POWER
MIC 1
5
0
1
2
3
4 6
7
8
9
10
BASS
0
-5
-4
-3
-2
-1 +1
+2
+3
+4
+5
TREBLE
0
-5
-4
-3
-2
-1 +1
+2
+3
+4
+5
5
0
1
2
3
4 6
7
8
9
10
MIC 3 AUX 1
5
0
1
2
3
4 6
7
8
9
10
AUX 2MIC 2
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
MASTER
5
0
1
2
3
4 6
7
8
9
10
ON
OFF
2
PROTTEMP
46810 12
OUTPUT LEVEL
12 3 4 5ALL
PREV MP3 VOL
PLAY NEXT RPT
MP3 PLAYER
USB
MIC 1
010
FLP-MA120U
MIXER AMPLIFIER
EMC INPUT
12
3
12
3
MUTE
COM 100V
CH1 CH2 CH3 CH4 CH5
COM 100V COM 100V
COM 100V
COM 100V
+
MIC 2
XLR
GAIN
MIC 2
+48V
PHANTOM
MIC2 MIC3
MIC 2 MIC 3
MIC 3
+48V
PHANTOM
AUX2
INPUT
MIX
OUT
AUX1
INPUT
MIC2 MIC3
LINE INPUT
MIC 3
XLR
GAIN
~240V 50Hz 200W
T3.15AL 250V
COM 4-16 70V 100V
OUTPUT
BATT SUPPLY
24V 5A
SPEAKER ZONES
POWER
MIC 1
5
0
1
2
3
4 6
7
8
9
10
BASS
0
-5
-4
-3
-2
-1 +1
+2
+3
+4
+5
TREBLE
0
-5
-4
-3
-2
-1 +1
+2
+3
+4
+5
5
0
1
2
3
4 6
7
8
9
10
MIC 3 AUX 1
5
0
1
2
3
4 6
7
8
9
10
AUX 2MIC 2
5
0
1
2
3
4 6
7
8
9
10
5
0
1
2
3
4 6
7
8
9
10
MASTER
5
0
1
2
3
4 6
7
8
9
10
ON
OFF
2
PROTTEMP
46810 12
OUTPUT LEVEL
12 3 4 5ALL
PREV MP3 VOL
PLAY NEXT RPT
MP3 PLAYER
USB
MIC 1
010
FLP-MA120U
MIXER AMPLIFIER

Version0.1
TMTM
This manual suits for next models
1
Table of contents
Other Flepcher Amplifier manuals
Popular Amplifier manuals by other brands

Sphere
Sphere MP-1 Mk.3.3 owner's manual

Crown
Crown D-75 Service manual

Rotel
Rotel Six Channel Power Amplifier RB-956AX owner's manual

Altec Lansing
Altec Lansing 1407A POWER AMPLIFIER manual

Amperes Electronics
Amperes Electronics MB2106 instruction manual

Channel Vision
Channel Vision CVT-2/8WB instructions