Flepcher FLP-PMC010 User manual

Portable Sound System Mixer Amp/ Pre Amp/ Power Amp Paging Microphone
& Zone selector Rack mount equipment
The PMC-010 is a one-stop solution in transforming your working space into a powerful setting for all your important
points of communication. With features such as number input keys and LED display, this unit understands your need and
it does its best to fulfil them through its array of reliable physical and software components. Designed to work together
with the ZS-9810, 1 unit of PMC-010 is able to call up to 300 zones when it is connected to 30 paging selectors.
The PMC-010 can be connected up to 16 unit using the RJ45 ports. Additionally each unit can be placed at dierence
place up to a total of 1 kilometre distance. With remote control capabilities, it eliminates any proximity barrier and free up
the space in your working centre, fostering a clean, organized and uncluttered working environment.
FLP-PMC-010
Digital Paging Console
• Capacity of managing 30 paging selector
• Maximum remote control distance of up to 1km
• Microphone volume control
• RCA line input and output
• Built-in chime and chime volume control
Product Features
Input
Output
Frequency Response
S/N Ratio
Controls
Indicators
Protection
Power Supply
Power Consumption
Communication Protocol
Communication Input
Communication Speed
Weight
Dimension (W x D x H)
Material & Finish
Specifications
Mic : 600Ω, 10mV, unbalanced
Line: 10kΩ, 775mV, unbalanced
Balanced
Mic: 100Hz~15kHz; Line: 30Hz~18kHz
Mic input: 60dB; Line input: 80dB
Chime Mic Vol controls, 160 channel selectors,
chime button, power switch
Power LED, 10 paging channel LEDs
AC fuse, 0.5A
DC24V
10W
RS422
RJ45
4800bps
1.25 kg
220mm x 150mm x 50mm
Panel: steel plate, black
Case: steel plate, black
Side board: plastic, black
DC 24V
input
Link to other
unit of PMC-010
Connect to line
input of ZS-9810
Connect to
ZS-9810
18

Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.
OPERATION MANUAL
PUBLIC ADDRESS SYSTEM
PAGING MIC CONSOLE
FLP-PMC010

TABLE OF CONTENTS
2
1. SAFETY PRECAUTIONS .......................................................................................3
2. FEATURES ...............................................................................................................4
3. NOMENCLATURE AND FUNCTIONS
3.1 Front Panel ............................................................................................................. 5
3.2 Rear Panel..............................................................................................................6
4. ..............................................................................................................7
5. APPLICATIONS ..................................................................................................... 11
6.SPECIFICATIONS .................................................................................................12
7.DIMENSIONAL DIAGRAM ...................................................................................13
OPERATION

3
1. SAFETY PRECAUTIONS
Be sure to read the instructions in this section carefully before use.
Make sure to observe the instructions in this manual as the conventions of safety symbols and messages
regarded as very important precautions are included.
We also recommend you keep this instruction manual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety
Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
Do not place cups, bowls, or other containers of
liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a
fire or electric shock.
Do not insert nor drop metallic objects or flammable
materials in the ventilation slots of the unit's cover,
as this may result in fire or electric shock.
When Installing the Unit When Installing the Unit
Should the following irregularity be found during
use, immediately switch off the power, disconnect
the power supply plug from the AC outlet and contact
y our nearest dealer. Make no furtherat-
tempt to operate the unit in this condition as this
may cause fire or electric shock.
If you detect smoke or a strange smell coming
from the unit.
If water or any metallic object gets into the unit
If the unit falls, or the unit case breaks
If the power supply cord is damaged (exposure
of the core, disconnection, etc.)
If it is malfunctioning (no tone sounds.)
To prevent a fire or electric shock, never open nor
remove the unit case as there are high voltage
components inside the unit. Refer all servicing
to your nearest dealer.
FLEPCHER
FLEPCHER
Do not expose the unit to rain or an environment
where it may be splashed by water or other liquids,
as doing so may result in fire or electric shock.
Use the unit only with the voltage specified on
the unit.Using a voltage higher than that which
is specified may result in fire or electric shock.
Do not cut,kink otherwise damage nor modify the
power supply cord. In addition, avoid using the
power cord in close proximity to heaters, and never
place heavy objects - including the unit itself - on
the power cord, as doing so may result in fire or
electric shock.
Be sure to replace the unit's terminal cover after
connection completion. Because high voltage
is applied to the speaker terminals,never touch
these terminals to avoid electric shock.
Be sure to ground to the safety ground (earth)
terminal to avoid electric shock. Never ground
to a gas pipe as a catastrophic disaster mayresult.
Avoid installing or mounting the unit in unstable
locations, such as on a rickety table or a slanted
surface. Doing so may result in theunit falling
down,causing personal injury and / or property
damage.

4
SAFETY PRECAUTIONS
An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.
Never plug in nor remove the power supply plug
with wet hands, as doing so may cause electric
shock.
When unplugging the power supply cord, be sure
to grasp the power supply plug; never pull on the
cord itself. Operating the unit with a damaged
power supply cord may cause a fire or electric
shock.
When moving the unit, be sure to remove its power
supply cord from the wall outlet. Moving the unit
with the power cord connected to the outlet may
cause damage to the power cord, resulting in fire or
electric shock. When removing the power cord, be
sure to hold its plug to pull.
Do not block the ventilation slots in the unit's cover.
Doing so may cause heat to build up inside the unit
and result in fire.
Avoid installing the unit in humid or dusty locations,
in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock.
Do not place heavy objects on the unit as this may
cause it to fall or break which may result in personal
injury and/or property damage. In addition, the object
itself may fall off and cause injury and/or damage.
Make sure that the volume ontrol is set to minimum
position before power is switched on. Loud noise
produced at high volume when power is switched
on can impair hearing.
Do not operate the unit for an extended period of
time with the sound distorting. Thisis an indication
of a malfunction, which in turn can cause heat to
generate and result in a fire.
Contact your dealer as to the cleaning.
If dust is allowed to accumulate in the unit over a
long period of time, a fire or damage to the unit
may result.
FLEPCHER
If dust accumulates on the power supply plug or in
the wall AC outlet, a fire may result. Clean it peri-
odically. Inaddition, insert the plug in the wall outlet
securely.
Switch off the power, and unplugthe power supply
plug from the AC outlet for safety purposes when
cleaning or leaving the unit unused for 10 days or
more. Doing otherwise may cause a fire or electric
shock.
Due to product upgrades, while some of the
features and specification in the user manual
does not match the actual functions, sorry for
any inconvenience and thanks for your kind
understanding!
When Installing the Unit When Installing the Unit
2. FEATURES
=All/ten zones.
=1 LINE output , 1 LINE input.
=Chime & MIC function.
=Remote-control available.

FLP-PMC010
PAGING MIC CONSOLE
CH1 CH2 CH3 CH4 CH5
CH6 CH7 CH8 CH9 CH10
ADDRESS
MIC ON/OFF CHIME ON TEN ZONES ALL ZONES
MIC
12
3
PUSH
3. NOMENCLATURE AND FUNCTIONS
3.1 FRONT PANEL
12346
58
710
9
111213
8. TEN ZONES
Ten zones switch button
9. ALL ZONES
All zones switch indicator
10. TEN ZONES
All zones switch button
11. (CH1~CH10)
Zone switch button
12. (CH1~CH10)
Zone switch indicator
13. MIC
MIC balance input
1. UP/DOWN
Up select button/Down select button
2. MIC ON/OFF
MIC SWITCH indicator
3. MIC ON/OFF
MIC SWITCH button
4. ADDRESS
LED screen
5. CHIME ON
Chime state indicator
6. CHIME ON
Chime triggering button
7. TEN ZONES
Ten zones SWITCH indicator
5

POWER
COM OUTPUT LINE IN CHIME
VOL
MIC
VOL
MIN MAXMIN MAX
POWER
24V 2A
RISQUE DE CHOC ELECTRIQUE
-NE PAS OUVRIR
AVIS:
RISK OF ELECTRIC SHOCK
DO NOT OPEN
NOMENCLATURE AND FUNCTIONS
14. POWER SWITCH
On top of the opening Power
Press the end, power shut down
15. DC 24V POWER INPUT
16. COM
Network Communication Port
17. OUTPUT
Line output, Non-equilibrium type,
the output of all input signals.
18. LINE IN
Line Balanced inputs
19. MIC VOL
MIC volume control
20. CHIME VOL
Chime volume control
3.2 REAR PANEL
14 15 16 17 18 19 20
6

First determine the scope to control the partition, and then press the " MIC ON / OFF ,
open the remote paging microphone, and then partition
Or region (10 districts) key, is called the partition ( ) or a response to allow
the region after the partition of paging radio
To carry out normal open or closed.
PAGING SELECTOR
4.OPERATION
Connect all lines, and is set correctly paging device address code area.
Boot display the address of the remote paging microphone code, as follows:
And so on.
The third Broadcasting operating region
0 1
0 2
0 3
After 0.3 seconds, showing two figures show the following:
Figures show that the control of the current partition.
Press the Select button, you can change the current partition control.
Shown as 1, said control section 1 to 10 partitions;
Shown as 2 when the control 11 to 20 partitions;
Shown as 3 when the control 21 to 30 partitions;
The second :Partition broadcasting operations
Zoning control whether any value displayed, press the remote paging microphone button
region, the region can be broadcast paging
Open or close operations.
Note:
The Fourth, broadcast music
When the partition is opened, the line input of music will be sent.
Press the bell button, built-in bell tone can be sent.
Press the microphone button, open the microphone, you can use the microphone to
broadcast.
1.When the bell or the microphone was opened, the line input of the music automatically
muted.
2.When the remote paging microphone is not turned on their own partition, a remote paging
microphone open for other partitions and simultaneously displayed, if
This time to the music player, then you need to open a microphone or a bell, the music can be
sent.
The first Operation
7

4.Status lights are areas
If the current partition the range of ten branch have all been opened, the status lamp is
automatically lit area, or out automatically. When the very area the state is lit, press the key
areas that are currently ten branch off, or that the ten minutes to open the current Area.
5.State region
If all the partitions have all been opened, the region's status light will turn on
automatically, or automatically switch off
6. the operation note
Remote paging microphone comes with an internal microprocessor, the switch-up time
must be spaced at least 10 seconds;
Remote paging microphone connected to equipment changes, please restart the computer,
or may not work;
Remote paging microphone with the PAGING SELECTOR connector systems. The number
of allowed two or more devices simultaneously access the same address.
At the same time, allowing only a remote call station at the same time PAGING SELECTOR
to make a call.
PAGING SELECTOR receives the current call FLP-PMC010 non-closure of the region data,
the data is not clear;
PAGING SELECTOR when the manual paging, paging will clear all the remote data;
PAGING SELECTOR short-circuit alarm, will clear all the remote paging, paging data
manually;
PAGING SELECTOR in manual paging or short-circuit alarm, remote paging microphone
FLP-PMC010 can not make any calls.
The seventh Note connections
UTP cable must be shielded twisted pair with a double, RJ45 connector joints must be
shielded
Cable shield must be two nine-pin D-shaped metal shell interface connection, making RJ45
connector, RJ45 shield must be Connector shield connection, otherwise you may burn
equipment
Remote paging microphone connector end of the first row of the last two pins short-circuit
must be connected, or may not function properly Paging control.
OPERATION
3.Partition status lights.
1.MIC status lights
Light: that the microphone is turned on
off: that the microphone is turned off
2.CHIME status lights
Light: that bell music is sent
Off: that the microphone is turned on
Bell lights can be manually opened, automatically shut down after the bell can not be
Manually closed.
Off: that this partition has been closed
Light: that this partition has been opened
Slow (0.5 seconds) flashes: waiting to be paging device, said response, slow flash to stop
That did not receive responses
Fast (interval 0.1 seconds) flash: that is paging device is in busy state, such as: the other
is paging equipment, radio or are in the local paging radio, or are in the alarm state. The end
of the state will know all the flash lights.
The fifth, the status light
8

OPERATION
Address code
drawing
Address code
drawing
The first
from 1~10
The ninth
from 81~90
from 11~20
The tenth
from 91~100
The third
from 21~30
The eleventh
from 101~110
The fourth
from 31~40
The twevle
from 111~120
The fifth
from41~50
The thirteenth
from 121~130
The sixth
from 51~60
The fourteenth
from 131~140
The seventh
from 61~70
The fifteenth
from 141~150
The Eighth
from 71~80
The sixteenth
from 151~160
The second
Definition Definition
1234
1234
1234
1234
1234
1234
1234
1234
1234
1234
1234
1234
1234
1234
1234
1234
PAGING SELECTOR ADDRESS CODE SETTING
9

OPERATION
PAGING SELECTOR ADDRESS CODE SETTING
1
1
2
2
3
3
4
4
1
1
2
2
3
3
4
4
1
1
2
2
3
3
4
4
1
1
2
2
3
3
4
4
1
1
2
2
3
3
4
4
1
1
2
2
3
3
4
4
1234
1234
5
5
5
5
5
5
5
5
5
5
5
5
5
55
Address code
drawing
Address code
drawing
Definition Definition
from 161~170
from 171~180
from 181~190
from 191~200
from 201~210
from 211~220
from 221~230
from 231~240
from 291~300
from 281~290
from 271~280
from 261~270
from 251~260
from 241~250
The seventeenth
The eighteenth
The nineteenth
The twentieth
twenty first
Twenty secondt
Twenty third
Twenty fourth
Twenty fifth
Twenty sixth
Twenty seventh
Twenty eighth
Twenty ninth
Thirtieth
10

The first
FLP-PMC010
The sixteentg
FLP-PMC010
The second
FLP-PMC010
The first
PAGING SELECTOR
The second
PAGING SELECTOR
The sxteentg
PAGING SELECTOR
MIC 2
IN
CHIME
VOL
LINE1
IN
LINE2
IN
AUDIO
OUT
+ - + - + - + -
ALARM IN ALARM OUT
+ A - + B- + A - + B -
ADDRESS COM
------------------------------
CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10
+ + + + + + + + + + + + + + + + + + + + + + + + + + + + + +
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10
MIC 2
IN
CHIME
VOL
LINE1
IN
LINE2
IN
AUDIO
OUT
+ - + - + - + -
ALARM IN ALARM OUT
+ A - + B- + A - + B -
ADDRESS COM
------------------------------
CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10
+ + + + + + + + + + + + + + + + + + + + + + + + + + + + + +
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10
MIC 2
IN
CHIME
VOL
LINE1
IN
LINE2
IN
AUDIO
OUT
+ - + - + - + -
ALARM IN ALARM OUT
+ A - + B- + A - + B -
ADDRESS COM
------------------------------
CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10
+ + + + + + + + + + + + + + + + + + + + + + + + + + + + + +
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
MUSIC IN
ALARM IN
OUTPUT
CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10
5. APPLICATIONS
REAR PANEL CONNECTIONS(1)
11
POWER COM OUTPUT LINE IN CHIME
VOL
MIC
VOL
MIN MAXMIN MAX
POWER COM OUTPUT LINE IN CHIME
VOL
MIC
VOL
MIN MAXMIN MAX
POWER COM OUTPUT LINE IN CHIME
VOL
MIC
VOL
MIN MAXMIN MAX
POWER
24V 2A
POWER
24V 2A
POWER
24V 2A

6.SPECIFICATIONS
MODEL
PROTECTION
OUTPUT
INPUT
FREQUENCY RESPONSE
CROSSTALK
CONTROLS
INDICATORS
PAGING MIC CONSOLEPAGING MIC CONSOLE
DIMENSION(mm)
NET WEIGHT
POWER CONSUMPTION
POWER REQUIREMENTS
GROSS WEIGHT
MIC 600 Ohms,10mV,Unbalanced
LINE 10KOhms, 400mV,Unbalanced
MIC:100Hz~15KHz;LINE: 20Hz~18KHz
MIC input : 80dB;Line input: 90dB
Chime MIC vol controls,160 channel selectors,
Chime button, powe switch
Power LED,10 paging channel LEDs
~240V 50Hz
AC fuse, 0.5A
484X360X88
FLP-PMC010
10W
Balanced
2.2Kg
2.6Kg
12

POWER
COM OUTPUT LINE IN CHIME
VOL
MIC
VOL
MIN MAXMIN MAX
POWER
24V 2A
RISQUE DE CHOC ELECTRIQUE
-NE PASOUVRIR
AVIS:
RISK OF ELECTRIC SHOCK
DO NOT OPEN
FLP-PMC010
PAGING MIC CONSOLE
CH1 CH2 CH3 CH4 CH5
CH6 CH7 CH8 CH9 CH10
ADDRESS
MIC ON/OFF CHIME ON TEN ZONES ALL ZONES
MIC
12
3
PUSH
7. DIMENSIONAL DIAGRAM
50
Over
50
Over
Over
50
UNIT:mm
UNIT:mm
176
144
19
19
144
144
13
POWER
COM OUTPUT LINE IN CHIME
VOL
MIC
VOL
MIN MAXMIN MAX
POWER
24V 2A
RISQUE DE CHOC ELECTRIQUE
-NE PASOUVRIR
AVIS:
RISK OF ELECTRIC SHOCK
DO NOT OPEN

PUBLIC ADDRESS SYSTEM
Version V0.3
Table of contents
Other Flepcher Microphone manuals