FLOTTWERK H.J. DAMES GMBH & CO. KG
8.) Maintenance
INSTALLING THE ROUND-HOLE PEELING DEVICE
With the door open, insert the peeling basket with the foot cam into the guide rails of the machine
vat so that the basket opening is aligned with the door section.
The basket must sit firmly on the edge of the cast section.
Place the support disk (arch downwards) on the square support piece, press the round-hole peeling
disk into the arch of the support disk. Screw the cap nuts on, insert the socket wrench in the
transverse borehole of the cap nuts and tighten them firmly.
REMOVING THE ROUND-HOLE PEELING DEVICE
Insert the socket wrench in the transverse borehole of the cap nuts and unscrew them.
Remove the support and peeling disk as well as, lastly, the peeling basket by pulling upwards.
When changing potato sorts please keep in mind the change of peeling time as well as, additionally,
the choice of different peeling disks:
peeling disk no. 1 = for new potatoes
peeling disk no. 2 = for medium potatoes
peeling disk no. 3 = for old potatoes
Only one side of the round-hole peeling disk is for peeling, so heed the indication ”up”.
INSTALLING THE CARBORUNDUM PEELING DEVICE
With the door open, insert the peeling basket with the foot cam into the guide rails of the machine
vat so that the basket opening is aligned with the door section.
The basket must sit firmly on the edge of the cast section.
Place the plate disks on the square support piece. Screw on the cap nuts, insert the socket wrench
in the transverse borehole of the cap nuts and tighten them firmly.
REMOVING THE CARBORUNDUM PEELING DEVICE
Insert the socket wrench in the transverse borehole of the cap nuts and unscrew them. Remove the
plate disks and the peeling basket by pulling upwards.
INSTALLING THE SUPER PEELING DEVICE with double-edged blades
With the door open, insert the bladed peeling basket with the foot cam into the guide rails of the
machine vat so that the basket opening is aligned with the door section.
The basket must sit firmly on the edge of the cast section. If the inlet lid cannot be shut, the basket
has not properly snapped into place at the bottom. The inlet lid should press against the black
rubber section of the basket and arrest it by closing the outer sealing bracket.
Place the blade disk on the square support piece and screw the cap nut on. Insert the socket
wrench in the transverse borehole of the cap nuts and tighten them firmly.
REMOVING THE BLADED PEELING DEVICE
Insert the socket wrench in the transverse borehole of the cap nuts and unscrew them. Unscrew the
cap nuts and remove the base disk. Remove the peeling basket by taking hold of the handles on the
upper edge.
THE SENSE OF ROTATION OF THE BASE DISK
can be changed by reversing the phase in the indentation of the Cekon plug.
WHEN INSTALLING AND REMOVING THE PEELING DEVICE gloves are to be worn.
AFTER INSTALLING OR REMOVING THE PEELING DEVICE remove the socket wrench from the
cap nut and peeling area.
SERVICE TASKS may only be done when the device is turned off and the mains plug pulled.
Conformity
The machines meets the requirements of the EG Machinery Directive 2006/42/EG