Y8846S/Y8846D
Instruction Sheet
2
Installing a Single Rack Mount
Kit
The Y8846S Single Rack Mount Kit allows for the
mounting of the Meter on either the left or right side
of a standard 19-inch rack. The following steps
describe mounting the Meter on the left side of the
rack.
1. Using one #8-32 x ½" panhead screw, attach the
right angle filler plate bracket on the right front
side of the Meter, keeping the smooth face with
two holes of the bracket facing the front as shown
in Figure 2.
2. With the tray flat on a desk with the rack screw
ears toward you, place the Meter so the left side
of the front frame is against the left wall of the
tray.
3. Attach the Meter to the tray by inserting one (two
for Hydra series) #8-32 x ½" panhead screw
through the left-hand forward holes in the tray
and into the side of the Meter as shown in
Figure 2.
4. Insert a #6-32 x ½" flathead screw through the
hole in the back of the tray and into the back of
the Meter as shown in Figure 2.
5. Attach the filler plate bracket on the right side of
the Meter to the bottom of the tray with a #6-32 x
¼" flathead screw as shown in Figure 2.
6. Install the 9½" painted filler panel to the right
front of the tray by inserting the attached screws
through the holes in the right-angle bracket and
locking it in with lock washers and lock nuts as
shown in Figure 2.
7. Install the assembled rack mount kit in the rack
using the four rack screws with the painted 1"
wide plate under the screws on the left-hand side
of the rack mount tray as shown in Figure 2.
8. Complete the installation by installing the Meter’s
power cord and other IO accessories through the
rear of the rack.
Figure 4 shows the dimensions.
Rack mount tray
#6-32 x 1/4” Flathead
Large filler plate
Small
filler plate
4x #10-32 x 3/4”
rack screws
Large filler bracket
#8-32 x 1/2” Panhead
#6-32 x 1/2” Panhead
2x #6-32 Hex nut with
lock washer
Single Rack Mount
1
5
4
6
2
3
7
caw502f.eps
Figure 2. Single Rack Mount