One Year Limited Warranty
is product is warranted to be free of defects in material and
workmanship for one year from the date of original purchase.
is warranty does not cover damages from misuse, abuse,
unauthorized adjustments/repairs or from commercial use. If the
product requires servicing, contact Forestry Suppliers, Inc. for
support.
Forestry Suppliers, Inc.
205 West Rankin Street
P.O. Box 8397
Jackson, MS 39284-8397
Phone: 800-647-5368
SN 89212
Digital Dual Sensor Thermometer
RESET
C˚/F˚
Quality products for environmental science since 1949
Key Features
• 2 Probes to capture independent data.
• Water resistant design for use outdoors.
• Large LCD displays readings from both sensors, low battery
indicator and ˚F/˚C.
• Full length cover protects the LCD, operation buttons and
battery compartment from exposure to environmental elements.
• Measurement range from -40/120˚F or -40/50˚C.
• Accuracy +/- 1.8˚F or +/- 1˚C.
• Reset button to restart data collection sequence.
• On/off, MIN and MAX buttons for each sensor.
• LCD auto-off function to save battery life.
• Uses 2 AA batteries.
65.5˚F
32.3˚F
MIN
MAX
D.2
D.2
Thermometer Overview
e product is a durable, data collecting, environmental thermometer. e water
resistant plastic housing incorporates a cover and rubber gaskets. ere are two
temperature probes with 3 meters of cable that capture data independently of one
another. e digital thermometer collects and stores current day, plus six days of
MAX/MIN data from each sensor. Smart circuitry collects data regardless if the
LCD display is on or off. Collected data is easily and clearly displayed on the large
LCD panel in either ˚F or ˚C.
How to use the thermometer
1. Install AA batteries: Battery compartment is located on the front side. When
closing the compartment, make sure gasket is properly seated to prevent
moisture from entering.
2.
Choose ˚F or ˚C: Press the ˚F/˚C button. Each press switches between ˚F or
˚C.
3.
Install thermometer: Determine where to place the thermometer (it can be
used indoors or outdoors). Use the 2 mounting holes to hang thermometer
onto a surface.
4.
Placing the Probes: Each sensor has approximately 3 meters of cable. Extend
the cables and place the probes where you would like to take the readings. For
example, one probe could be in the ground soil while the other probe is in the
air.
5. Reset the thermometer: Press the “Reset” button to begin a new collection
sequence.
6.
View the temperature reading: Temperatures from each sensor are collected
for the current 24 hour period and up to six previous 24 hour periods. e
left and right sensors each have their own On/Off, MAX and MIN Buttons.
Pressing the “On/Off” button activates the LCD display. e first press of the
MAX or MIN button will show the current reading (up to previous 24 hours).
With each subsequent press of the MAX or MIN button displays the previous
24 hour period temperatures. 24 hour periods are indicated as D1 (for day 1),
D2 (for day 2), etc... up to D6.
Special Notes to remember:
• e LCD display will turn-off automatically within 10 minutes. e
thermometer is always collecting data even while the LCD display is on or off.
• Only the six previous days of data are collected and stored.
• Always keep the rubber gaskets in place when closing the battery compartment.
• Close the cover whenever possible to protect the LCD display and operation
buttons.
• If using the thermometer in very low temperatures, it is recommended to use
lithium AA batteries.
THERMOMETER DIAGRAM
RESET
C˚/F˚
Protective cover
Left sensor display area
Right sensor display area
LCD panel
Battery indicator
Right sensor buttons
Reset button
Left sensor buttons
AA Battery compartment
Right sensor cableLeft sensor cable
˚F/˚C button
Holes for
mounting
65.5˚F
32.3˚F
MIN
MAX
D.2
D.2
Right sensor
Left sensor

Popular Thermometer manuals by other brands

Berrcom JXB-182 user manual

Berrcom

Berrcom JXB-182 user manual

Govee H5183 user manual

Govee

Govee H5183 user manual

GREISINGER G 1700 operating manual

GREISINGER

GREISINGER G 1700 operating manual

bbluv Krab manual

bbluv

bbluv Krab manual

Philips SBCSC550 Specifications

Philips

Philips SBCSC550 Specifications

Yudian AI-5500 manual

Yudian

Yudian AI-5500 manual

Extech Instruments IR267 user manual

Extech Instruments

Extech Instruments IR267 user manual

Extech Instruments 42545 user manual

Extech Instruments

Extech Instruments 42545 user manual

Mastech MS6540A user manual

Mastech

Mastech MS6540A user manual

Labom FA series operating instructions

Labom

Labom FA series operating instructions

Summer Ear Thermometer instruction manual

Summer

Summer Ear Thermometer instruction manual

Denver TRC-1460 instruction manual

Denver

Denver TRC-1460 instruction manual

Stanley STHT0-77365 user manual

Stanley

Stanley STHT0-77365 user manual

Microlife VT 1831 manual

Microlife

Microlife VT 1831 manual

Omron E5L-C Series instruction manual

Omron

Omron E5L-C Series instruction manual

DAY 73361 instruction manual

DAY

DAY 73361 instruction manual

TEL-TRU QT4242L operating instructions

TEL-TRU

TEL-TRU QT4242L operating instructions

Renkforce 1267652 operating instructions

Renkforce

Renkforce 1267652 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.