FRÄNKISCHE alpex F50 PROFI User manual

PPSU/Messingverbinder
PPSU/brass connectors
DE/EN.70048/16.07.21 | Cat no. 5000-1281-00 | Subject to change without notice | 03/2021
FRÄNKISCHE Rohrwerke Gebr. Kirchner GmbH & Co. KG
I Hellinger Str.1 I 97486 Königsberg/Germany
Phone +49 9525 88-2200 | Fax +49 9525 88-92200 | marketing@fraenkische.de | www.fraenkische.com
Montageanleitung / Mounting instructions – alpex F50 PROFI PPSU/Messingverbinder / PPSU/brass connectors
alpex F50 PROFI Verbinder – 5 verschiedene Konturen
Pressbacke immer mittig auf der Presshülse ansetzen!
alpex F50 PROFI connectors – 5 dierent contours
Always set the press jaw centrally on the pressing sleeve!
TH-Kontur – Presssysteme diverser Hersteller*
TH-contour – pressing systems from various
manufacturers*
U-Kontur – Presssysteme diverser Hersteller*
U-contour – pressing systems from various
manufacturers*
H-Kontur – Presssysteme diverser Hersteller*
H-contour – pressing systems from various
manufacturers*
TH-Kontur/contour
U-Kontur/contour
H-Kontur/contour
VP-Kontur – Presssysteme diverser Hersteller*
VP-contour – pressing systems from various
manufacturers*
F-Kontur – FRÄNKISCHE Pressbacken
F-contour – FRÄNKISCHE press jaws
F-Kontur/contour
VP-Kontur/contour
* Systemübersicht unter der kostenfreien Technik-Hotline 0 800 / 10 140 79 oder
unter www.fraenkische.com abrufbar.
System overview available at www.fraenkische.com
Montageanleitung / Mounting instructions – alpex F50 PROFI PPSU/Messingverbinder / PPSU/brass connectors Montageanleitung / Mounting instructions – alpex F50 PROFI PPSU/Messingverbinder / PPSU/brass connectors
alpex F50 PROFI®
Montageanleitung / Mounting instructions
Building Technology
www.fraenkische.com
alpex F50 PROFI Verbinder aus PPSU / Messing ...
Achtung: Keine Schmier- oder Gleitmittel auf den O-Ring auftragen!
nsind zu verlegen unter Beachtung der technischen Parameter und
Vorgaben zur Verbindungsherstellung entsprechend unseren Produkt-
beschreibungen sowie der Beipackzettel alpex F50 PROFI.
nsind vor Öl, Fett, Farbe, PU, Lösungsmitteln, Klebstoen, organischen
Reinigungsmitteln sowie vor ammoniak- und chlorhaltigen Verbindungen
zu schützen.
ndürfen nicht als Festpunkt oder zum Biegen eines Rohrbogens verwendet
werden und sind erst am fertigen Rohrbogen anzubringen.
nsind grundsätzlich spannungsfrei zu verarbeiten und ausschließlich mit
alpex F50 PROFI bzw. turatec multi Rohr zu verpressen.
ndürfen nur im Bereich gerader Rohrstrecken eingesetzt werden.
nsind nach dem Befüllen der Anlage mit Wasser im Bereich von 1 bis
6,5bar im unverpressten Zustand sichtbar undicht. Sichtkontrolle erforder-
lich. Siehe Druckprobenprotokoll alpex F50 PROFI.
nmüssen nach der Installation und vor den Verputzarbeiten/Estricharbeiten
usw. nach ZVSHK druckgeprüft und auf Dichtheit kontrolliert werden.
Prüfmedium Wasser: Sanitär nach DIN EN 806-4 (min. 11 bar) und für
Heizung nach DIN 18380 (ca. 4-6 bar). Prüfmedium Druckluft: nach DIN
EN 806-4 (Dichtigkeitsprüfung 150 mbar; Festigkeitsprüfung 3 bar).
Siehe Druckprobenprotokoll alpex F50 PROFI.
nkönnen mit alpex F50 PROFI bzw. turatec multi Rohr unter Beachtung ent-
sprechender Schutzmaßnahmen im Fußbodenaufbau unterhalb von Heiß-
asphalt verlegt werden (siehe Technische Information alpex).
nsind resistent gegen Desinfektions- und Reinigungsmittel nach DVGW-
Arbeitsblatt W 291 und DIN 2000 sowie gegenüber allen natürlichen Trink-
wasserinhaltsstoen gemäß DIN 2000.
nund Formteile sind entsprechend zu installieren um die Anforderungen
nach DIN 4109 – Schallschutz im Hochbau zu erfüllen!
n
sind gemäß den Anforderungen nach DIN 1988 / DIN EN 806 und dem
aktuellen GEG zu dämmen (siehe Technische Information alpex).
nmüssen, wenn sie mit Wasser gefüllt sind, durch entsprechende Maß-
nahmen vor Frost geschützt werden (z.B. Beheizung, Frostschutzmittel,
mit Druckluft ausblasen).
nund alpex F50 PROFI bzw. turatec multi Rohre sind grundsätzlich von
anerkannten Fachbetrieben zu verlegen.
nsind mit alpex-Werkzeugen sowie freigegebenen Werkzeugen gemäß
Kompatibilitätsliste zu verarbeiten.
nsind vor UV-Strahlung zu schützen.
Please note: Do NOT apply any lubricants to the O-ring!
alpex F50 PROFI connectors made of PPSU / brass ...
Guidelines for use
nmust be installed in compliance with the technical parameters and specifi-
cations for connection in accordance with our product descriptions and the
alpex F50 PROFI mounting instructions.
nmust be protected against oils, greases, paint, PU, solvents, adhesives,
organic cleaning agents, and against ammonia or chloride compounds.
nmust not be used as a fixed point or for pipe bending, and must only be
installed on the finished pipe bend.
nmust generally be installed stress-free and may only be crimped with the
alpex F50 PROFI or turatec multi pipe.
nmay only be used in straight pipe sections.
nare visibly leaking if left uncrimped after the system has been filled with
water in the range of 1 to 6.5bar. Visual inspection required. See pressure
test report alpex F50 PROFI.*
nmust be pressure-tested according to ZVSHK and checked for leak-tightness
after installation and before plastering, screed work or the like.
Water as a test medium: sanitary according to DIN EN 806-4 (at least 11bar)
and for heating according to DIN 18380 (approx.4 to 6bar). Compressed air
as a test medium: according to DIN EN 806-4 (leak-tightness test 150mbar;
strength test 3bar). See pressure test report alpex F50 PROFI.*
ncan be installed in the floor structure under hot asphalt with an alpex
F50PROFI pipe or turatec multi pipe taking into account the respective
protection measures (seeTechnical Information).
nare resistant to disinfectants and detergents according to DVGW work-sheet
W 291 and DIN 2000 and to all natural ingredients of drinking water accord-
ing to DIN 2000.
nfittings must be installed appropriately in order to meet the requirements
according to DIN 4109 –Sound insulation in buildings.
nmust be insulated according to the requirements of DIN 1988 / DIN EN 806
and the applicable German Building Energy Act (GEG) (seeTechnical Infor-
mation).
nmust be protected against frost by adequate means if filled with water
(e.g. heating, antifreeze agents, blowing out with compressed air).
nalpex F50 PROFI pipes or turatec multi pipes must generally be installed by
recognised experts.
nmust be processed with alpex tools and tools approved according to the
compatibility list.
nmust be protected from UV radiation.
Anwendungsrichtlinien
alpex F50 PROFI PPSU/Messing Formteile – PPSU/brass fittings
Montageanleitung / Mounting instructions – alpex F50 PROFI PPSU/Messingverbinder / PPSU/brass connectors Montageanleitung / Mounting instructions – alpex F50 PROFI PPSU/Messingverbinder / PPSU/brass connectors
Montageanleitung / Mounting instructions – alpex F50 PROFI PPSU/Messingverbinder / PPSU/brass connectors Montageanleitung / Mounting instructions – alpex F50 PROFI PPSU/Messingverbinder / PPSU/brass connectors
Ablängen / Cutting to the length
CU
Dim.
14 – 40 79000225
14 – 75 79000228
1
alpex Montagehelfer / alpex installation aid
5 cm
Dim.
16/20/26/32 79002213
Dim.
16/20/26/32 79002250
Dim.
14 – 75 79002208
5 cm
Entgraten / Deburring
2a
Optional Kalibrieren / Optional calibration
2b
Zusammenfügen / Connecting
3Verpressen / Pressing
4
Dim.
12 – 20 mm 79400220
3
2
3
6
0
°
Verarbeitungsrichtlinien / Installation guidelines

Other FRÄNKISCHE Plumbing Product manuals

FRÄNKISCHE FIPLOCK BHPA User manual

FRÄNKISCHE

FRÄNKISCHE FIPLOCK BHPA User manual

FRÄNKISCHE profi-air Filterset G4/G4 User manual

FRÄNKISCHE

FRÄNKISCHE profi-air Filterset G4/G4 User manual

FRÄNKISCHE AquaDock User manual

FRÄNKISCHE

FRÄNKISCHE AquaDock User manual

FRÄNKISCHE Quadro Lift User manual

FRÄNKISCHE

FRÄNKISCHE Quadro Lift User manual

FRÄNKISCHE alpex-duo XS Instruction Manual

FRÄNKISCHE

FRÄNKISCHE alpex-duo XS Instruction Manual

Popular Plumbing Product manuals by other brands

Sentiotec wave.com4 11 kW Instructions for installation and use

Sentiotec

Sentiotec wave.com4 11 kW Instructions for installation and use

Aqualisa Visage installation guide

Aqualisa

Aqualisa Visage installation guide

Sanela SLUN 07EB Instructions for use

Sanela

Sanela SLUN 07EB Instructions for use

Spectrum Pfister Brea LF-042-BR Maintenance & Care Guide

Spectrum

Spectrum Pfister Brea LF-042-BR Maintenance & Care Guide

Clou mini wash me CL/03.03135 installation instructions

Clou

Clou mini wash me CL/03.03135 installation instructions

Zurich RS-II installation manual

Zurich

Zurich RS-II installation manual

Signature Hardware SHWE2020 quick start guide

Signature Hardware

Signature Hardware SHWE2020 quick start guide

Toto WASHLET A100 installation guide

Toto

Toto WASHLET A100 installation guide

Sanela SLU 60 Instructions for use

Sanela

Sanela SLU 60 Instructions for use

Toto GE TBG07201U Installation and owner's manual

Toto

Toto GE TBG07201U Installation and owner's manual

Franke CRYSTAL SEMI-PRO FFPD4600 installation manual

Franke

Franke CRYSTAL SEMI-PRO FFPD4600 installation manual

Symmons SPP-3510 instructions

Symmons

Symmons SPP-3510 instructions

Heritage Bathrooms Dartmouth SDABL01 Installation instructions & user guide

Heritage Bathrooms

Heritage Bathrooms Dartmouth SDABL01 Installation instructions & user guide

Sapho KU211 user manual

Sapho

Sapho KU211 user manual

Lippert Flow Max 719323 Installation and owner's manual

Lippert

Lippert Flow Max 719323 Installation and owner's manual

American Standard Silhouette 7179.011 Specification sheet

American Standard

American Standard Silhouette 7179.011 Specification sheet

Saunavita KYRA Assembling Instruction

Saunavita

Saunavita KYRA Assembling Instruction

Watts AERCO ADMS Series User guide/instruction manual

Watts

Watts AERCO ADMS Series User guide/instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.