4 - Unpacking and Installation Instructions
The following instructions should be read and fully understood prior to installing the equipment to
ensure that the correct procedures are followed and all safety precautions are observed.
Note: If the equipment has been in storage for a considerable amount of time, it is advisable
to conduct a routine maintenance check on all parts before installation.
Safety Precautions
This equipment should not be connected to an electrical supply before being installed. Installation
procedures should be adhered to in order to ensure a safe working environment and reduce the
risk of damage or personal injury.
Preparing the Mounting Position
Mark out and drill the fixing holes through the deck. If anti-vibration mounts are to be fitted, the
fixing holes for the mounts should also be marked out and drilled. Prior to manoeuvring the
searchlight into its’ fixing position, the AV mounts should be fitted to the base. When in the desired
position, bolt the searchlight firmly down.
5 - Electrical Installation
For safety purposes, only competent personnel should perform the electrical installation. All
equipment should be installed to current Electrical Regulations and Standards.
In order to obtain the maximum light output from the searchlight, it is essential that the full
operating voltage of the LED fitted be applied to the LED contacts.
Method of Electrical Connection
1) Disconnect the supply before working on the electrical system;
2) The searchlight must be connected to a fused electrical supply, using suitably sized cable;
3) If the searchlight is located a considerable distance from the supply, provision must be made in
the cable size in order to overcome the voltage drop.
4) Whenever possible cable terminations should be made below deck and with approved terminal
devices;
5) If a spare auxiliary fuse or circuit breaker is not available, one of the correct type and rating
should be fitted and connected to a positive supply. It is advisable to locate a bus bar or main
connection and avoid any direct connection to the supply:
6) For 110/220v AC products, the following colour coding system should be used for the customer
supply cable:
Brown - Live
Blue - Negative
Green/Yellow - Earth