FRANCO G Series Instruction manual

INSTRUCTION MANUAL FOR
USE AND MAINTENANCE
Manual version: 2019-A
G
HOT AIR
GENERATORS
TRANSLATED VERSION FROM ITALIAN TO
E N G L I S H
Before installing or running the unit,
it is obligatory to carefully read and consult this manual.
Franco srl –Via Nazionale, 80 12010 Cervasca (CN), Italy

FRANCO srl Manual of use and maintenance G series
2

FRANCO srl Manual of use and maintenance G series
3
INDEX
INDEX ......................................................................................................................................3
1 - INTRODUCTION.................................................................................................................4
1.1 General warnings............................................................................................................4
1.2 Instructions for proper disposal of the product................................................................4
1.3 Covenants used throughout this manual ........................................................................5
1.4 Conservation of the instruction manual...........................................................................5
1.5 Recipients.......................................................................................................................6
1.6 Glossary and pictographs...............................................................................................6
1.7 Applications .................................................................................................................. 10
1.8 Versions........................................................................................................................10
1.9 Identification and data label of the unit .........................................................................10
1.10 Parts description.........................................................................................................11
1.11 Transport and handling...............................................................................................11
1.12 Warranty..................................................................................................................... 12
1.13 Manufacturer’s identification data ...............................................................................12
1.14 Statements..................................................................................................................12
1.15 Declaration of conformity............................................................................................ 13
2 - INSTALLATION................................................................................................................ 14
2.1 Before installing............................................................................................................ 14
2.2 Positioning....................................................................................................................14
2.3 Electrical connection.....................................................................................................15
2.4 Gas supply connection..................................................................................................15
3 - OPERATION..................................................................................................................... 15
3.1 Getting started..............................................................................................................15
3.2 First start.......................................................................................................................15
3.3 Start and stop ...............................................................................................................16
4 - MAINTENANCE................................................................................................................ 16
4.1 Cleaning........................................................................................................................16
4.2 Replacement or cleaning of the nozzle.........................................................................17
5 –TECHNICAL SPECIFICATIONS...................................................................................... 17
5.1 Technical data ..............................................................................................................17
5.2 Wiring............................................................................................................................18
5.3 WIRING DIAGRAM G36-25 –G45-40..........................................................................18
5.4 WIRING DIAGRAM G56-65 –G56-90..........................................................................19
5.5 THERMOSTATIC SOCKET USAGE ............................................................................19
5.6 Spare parts...................................................................................................................20
6 –PROBLEMS AND SOLUTIONS ...................................................................................... 23

FRANCO srl Manual of use and maintenance G series
4
1 - INTRODUCTION
1.1 General warnings
This device must be used only for the functions for which it was intended "Hot air generator”. Any other use is to
be considered improper and dangerous. Franco srl cannot be held liable for any damages caused by improper,
incorrect or unreasonable use, or if the device is used in systems that do not comply with safety regulations.
- Check the integrity of the device at the opening of the package, paying particular attention to the presence of
damages or deformations that can lead to breakage and / or malfunction during use. In such cases do not
connect the machine to the mains. Carry out these checks before each use.
- Before connecting the unit, make sure that the data shown on the device’s plate matches that of your electricity
distribution network. The data label is located on the side of the device (par.1.9).
- Respect the safety standards set for the electrical equipment and in particular:
oFollow the installation and operation instructions concerning the use of the equipment.
oDo not place objects on the generator.
oAvoid children from using the device, and / or unable subjects without proper supervision.
oDo not touch the generator during operation or until it is completely cooled down.
oNever place water or any other liquids into the device. In the scenario of the device becoming wet,
immediately turn off the electricity by lowering the switch on the electrical panel of your system and
disconnect the power before touching the device.
oDo not insert objects inside the tank as the device may be damaged irreparably.
oDo not use accessories, spare parts and / or components that are not provided or supplied by the
manufacturer.
oAvoid touching the appliance with wet and / or humid hands.
oDo not pull the power cord nor expose it to risk of severing.
oDo not expose the unit to weather (rain, sun, etc...).
oIn case of failure or malfunction, switch off immediately and disconnect the power.
oDo not try to open or tamper the device: contact the technical service offered by
Franco srl.
1.2 Instructions for proper disposal of the product
Under the European Directive 2002/96/EC.
At the end of its useful life the product must not be disposed of as waste.
The device can be taken to special recycling centers provided by local authorities, or at retailers that provide this
service. Disposing the product in separate parts avoids possible negative consequence to the environment and
to human health, which would both be the result of an inappropriate disposal, and allows the retrieval of
materials so that significant savings in energy and resources would be reached. As a reminder of the obligation
to dispose electrical equipment separately, the product is marked with the crossed mobile waste container.
Fig. 1.1

FRANCO srl Manual of use and maintenance G series
5
1.3 Covenants used throughout this manual
The Manual is divided into autonomous chapters, each of which is addressed to a specific operator’s figure
(installer, operator and maintainer), for which the skills needed to operate the machine safely have been defined.
The sequence of chapters follows the temporal logic life of the machine.
To facilitate the immediate comprehension of the text, throughout the manual are used terms, abbreviations and
pictograms, whose meaning is shown below.
The Instruction Manual consists of a cover, an index and a series of chapters (sections).
The home page lists the identification data of the machine and model, the revision of the manual instructions,
and finally, a picture of the machine described, drawn in order to facilitate the reader in identifying the machine
and its use.
ABBREVIATIONS
Ch. = Chapter
Par. = Paragraph
P. = Page
Fig. = Figure
Tab. = Table
UNITS OF MEASURE
The units of measure used in this manual are those provided by the International System (SI).
1.4 Conservation of the instruction manual
The instruction manual must be carefully stored and must follow and match the device in all the cases of change
of ownership incurred during the life span of the machine itself.
The conservation must be done by handling the manual with care, with clean hands and on clean surfaces. Parts
must not be removed, torn or arbitrarily modified.
The manual must be stored in a secure environment, protected from moisture and heat, and near the referring
device. The manufacturer, if requested by the User, may provide additional copies of the instruction manual of
the machine.
The User can request additional copies of the manual by writing to customer@francosrl.com.
METHODOLOGY FOR UPDATING THE MANUAL
The Manufacturer reserves the right to modify the design or specifications of the machine as part of its policy of
improving and enabling them to comply with the statutory or other requirements or standards applicable in any
territory in which goods are sold, without notifying the Customer and without updating the manuals given to the
user. Moreover, in case of changes (previously agreed between the Customer and the manufacturer) to the
machine installed, which signifies the modification of one or more chapters of the Handbook of Instructions, the
manufacturer will be responsible for sending the modified chapters affected by the structural change (including
the new model of revision) to the User.
The User is responsible, following the directions accompanying the updated documentation, for replacing all the
copies owned, the old chapters with the new chapters, the home page, and the index with the copy updated to
the new revision level.
The manufacturer shall be responsible for the descriptions included in this manual; in case of an inconsistency
being detected in a translated version of the manual (English version), the reader must refer back to the original
Italian version of the handbook and, eventually, contact the sales department, who will make necessary
changes.

FRANCO srl Manual of use and maintenance G series
6
1.5 Recipients
The manual is addressed to: the installer, the operator, and the qualified personnel entitled to the maintenance
of the device.
EXPOSED PERSON:
refers to any person exposed, wholly or partially, to a danger zone;
OPERATOR:
refers to those persons responsible for installing, operating, regulating,
clearing, repairing and moving the machine, and also performing the
maintenance of the device;
QUALIFIED PERSONNEL
QUALIFIED OPERATOR:
refers to the persons who have completed courses of specialization and
training, and that have acquired experience in: installing, starting,
operating, maintaining, repairing and transporting the device, or similar
ones.
The machine is intended for industrial use (professional and not widespread) for which qualified operators are
needed, in particular, workers that:
Have reached the age of majority;
Are physically and mentally appropriate to perform works that include technical difficulties;
Have been properly educated on the use and maintenance of the machinery;
Have been considered suitable to undertake the assigned job by their employer;
Can understand and interpret the operator’s manual and the safety requirements;
Know the emergency procedures and their implementation;
Posses the ability to operate the specific type of equipment;
Are familiar with the specific applicable rules;
Have understood the operating procedures defined by the manufacturer of the machine.
1.6 Glossary and pictographs
In this section we list the non common terms included in the manual. The following also explains the
abbreviations used and the meaning of the pictograms in relation to the qualification of the operator and the state
of the machine; their use can provide quick and unique information, necessary for the proper use of the machine
under safety conditions.
GLOSSARY (Att. I p. 1.1.1 Dir. 2006/42/CE)
HAZARD
A potential source of injury or damage to personal health;
DANGER ZONE
All areas within and/or around the machinery in which the
presence of a person constitutes a risk to the health and safety of
himself/herself;
EXPOSED PERSON
Any person that finds himself/herself entirely or partially in a
hazardous area;
OPERATOR
The person responsible for installing, operating, regulating,
clearing, repairing and moving the machine, and also performing
the maintenance of the machinery;
RISK
The combination of probability and severity of an injury or harm to
health that can arise in a hazardous situation;
GUARD
The part of the machinery used specifically to provide protection by
means of a physical barrier;
PROTECTION DEVICE
The device (other than a shelter) that reduces (alone or in
conjunction with a shelter) the risk of an operation;
INTENDED USE
Use of the machinery according to the information provided in the
instruction manual;
REASONABLY FORESEEABLE
MISURE
Use of the machinery in an indifferent manner from that stated in
the instruction manual, which may result from a foreseeable
human behavior.

FRANCO srl Manual of use and maintenance G series
7
OTHER DEFINITIONS:
HUMAN-MACHINE INTERACTION: Any situation in which an operator interacts with the machine in any of
the operational phases at any time of the life of the machine itself;
OPERATOR’S QUALIFICATION: Minimum level of competence that an operator must have in order to
perform the described operation;
NUMBER OF OPERATORS: The appropriate number of operators needed to optimally perform the
described operation, it is derived from an accurate analysis made by the
manufacture, and for which the use of a different number of operators
may prevent the occurrence of the expected result or endanger the
safety of the personnel involved;
STATE OF THE MACHINE: The state of the machine includes the operating mode, for example:
running in automatic mode, maintained action control (jog), shutdown,
etc… the safety conditions on the machine such as included protectors,
excluded protectors, emergency shutdown, isolation from energy
sources, etc…
RESIDUAL RISK: Risks that remain, despite of the protective measures incorporated in the
design of the machine, the complementary protections, and the
additional protective measures.
SAFETY COMPONENT: Component:
- designed to fulfill a safety function;
- the failure and/or malfunctioning of which endangers the safety of
persons (such as a lifter; a fixed, moving or adjustable protector; an
electrical, electronic, optical, pneumatic or hydraulic device that interlock
a protector; etc…).

FRANCO srl Manual of use and maintenance G series
8
PICTOGRAPHS CONCERNING THE OPERATOR’S QUALIFICATION
Symbol
Description
Generic laborer: operator lacking of specific competences, capable of performing only simple tasks
under the control of qualified technicians.
Lifting and handling vehicles driver: operator qualified for the use of vehicles used in lifting and
handling materials and machines (carefully following the manufacturer’s instructions), in accordance
with the user’s country’s laws.
Mechanic maintainer: qualified technician, able to operate the machine under normal conditions, to
run it with the maintained action control (JOG) with disabled protections, and to intervene on the
mechanical parts in order to make the necessary adjustments, maintenances and repairs. Typically
this operator is not qualified to work on electrical systems while the device is connected to the
mains.
Electrical maintainer: qualified technician, able to operate the machine under normal conditions, to
run it with the maintained action control (JOG) with disabled protections, and enabled to any kind of
operation of electrical adjustment, maintenance and repair. This operator is qualified to work on
electrical systems while the device is connected to the mains.
Manufacturer’s technician: qualified technician offered by the manufacturer to carry out complex or
particular operations or, in any other case agreed with the user. The skills are, as contingently
appropriated, mechanical and/or electrical and/or electronic and/or concerning software.
PICTOGRAPHS CONCERNING THE STATE OF THE DEVICE
The pictographs contained in a square/rectangle provide information.
Symbol
State of the device
Device OFF: with electric and pneumatic power disconnected.
Machine in motion: with automatic function, movable protections closed and relative interlocking
devices activated, and fixed protections closed.
Device ON: in standby and ready to start by functional consent activation (eg. switchboard
consent), movable protections closed with relative safety device included, and fixed protections
closed.

FRANCO srl Manual of use and maintenance G series
9
PICTOGRAPHS CONCERNING SAFETY
The pictograms contained in a triangle indicate DANGER.
The pictograms contained in a circle impose PROHIBITION / OBLIGATION.
Pictograph
Denomination
Hazardous voltage.
Entanglement.
Dragging.
General danger.
Do not remove safety devices.
Prohibition of cleaning, oiling, greasing, repairing or adjusting by hand when the device is in motion.
Duty to remove power before starting works or repairs.
Protective gloves required.
Safety footwear required.
Safety helmet required.

FRANCO srl Manual of use and maintenance G series
10
1.7 Applications
The G series series hot air generators run on LPG (Liquid petroleum gas) and methane as the combustion fuel.
The G series generators are of direct combustion type. The air is heated by means of the thermal energy
generated during combustion and is transferred to the environment to be heated with the combustion products,
thereby rendering the thermal energy produced 100% available. The environment must be suitably ventilated in
order to ensure sufficient air exchange.
Do not use the generator in basements or below ground level or in premises destined for domestic use.
There are a series of safety devices which come into effect in the event of faulty function. The electronic control
device intervenes in the event of irregular flame or flame which tends to go out, stopping the burner and igniting
the burner block button indicator.
G56-70 and G56-100 stop if there is a fault in ventilation.
The materials used in building the machine ensure reliability and durability in time.
This device must be used only for the functions for which it was intended
- Hot air generator.
Any other use is to be considered improper and dangerous.
1.8 Versions
Hot air generators G series are available in the following versions:
1458200 Generatore G36-25 25kW 3.000m³/h 230V 50Hz 1~+N
1458300 Generatore G45-40 40kW 4.000m³/h 230V 50Hz 1~+N
1458400 Generatore G56-65 65kW 7.000m³/h 230V 50Hz 1~+N
1458500 Generatore G56-90 90kW 8.000m³/h 230V 50Hz 1~+N
1.9 Identification and data label of the unit
Each machine is identified by the CE plate on which, indelibly set, is reference data of the device itself.
In any communication, either with the manufacturer or with the customer service, always cite these references.
Fig.1.2

FRANCO srl Manual of use and maintenance G series
11
1.10 Parts description
Constituent parts of the hot air generator.
Fig.1.3
1.11 Transport and handling
The machine has been properly packaged before being put into strong carton boxes.
Prevent damages to the components of the device by taking care when opening the package.
Verify the integrity of the machine by controlling that there are no visible damaged parts.
Do not dispose the packaging elements in the environment; they must be placed in proper collection
points.
G series generator can be lifted and hung by using the proper brackets.
WARNING!
Before handling the device:
a. stop the machine,
b. disconnect the electricity supply,
c. interrupt the water supply.
d. Wait for the exchanger to cool down
To lift the machine, use a suitable lifting device (consult the weights table).
Lift the machine slowly, being careful not to drop it and move the straps depending on the centre of mass.
Protection grill
Suction side
Protection grill
ventilation side
Burner disk
Burner
Thermostat bulb
Fan motor
Fan
Electrodes
Flame sensing / ignition
n.4 suspension/fixing
screws
Electric box
(flame control device, gas valve,
etc…)
GAS
connection ½”
(in the bottom side
of the electric box)
Reset button
Thermostat reset
Thermostat socket

FRANCO srl Manual of use and maintenance G series
12
1.12 Warranty
This device is guaranteed for 12 months from the date of manufacture for all failures attributed to a proven
manufacturing or material defect.
All the parts damaged by transport, improper maintenance, negligence, inability to use, improper use, tampering
by unauthorized personnel and by any other cause not dependent from the company Franco s.r.l. from Cervasca
(CN), Italy. During the warranty period, the company Franco s.r.l. commits itself to replace or repair free of
charge those parts which result faulty from the origin.
The intervention must be made at Franco s.r.l. with transport charged to the user.
1.13 Manufacturer’s identification data
Manufacturer
FRANCO S.r.l.
Registered office –Administrative headquarters
VIA NAZIONALE, 80 - 12010 CERVASCA (CN) - ITALY
Contacts
Tel.: (0039) 0171 - 61.16.63
Fax: (0039) 0171 - 61.23.37
Email: [email protected]
Web: www.francosrl.com
1.14 Statements
The machine is built in accordance with the EC directives that are relevant and applicable at the time of the
market entry of the machine itself.
The machine is not among those mentioned in the Att. IV of the Directive 2006/42/CE.

FRANCO srl Manual of use and maintenance G series
13
1.15 Declaration of conformity
(All. IIa DIR. 2006/42/CE)
FRANCO S.r.l.
Company
Via Nazionale, 80 12010 CN
Address Postal code Province
Cervasca Italy
City Country
DECLARE THAT THE MACHINE
Hot air generators G36-25; G45-40; G56-65; G56-90
Description Model
1458200; 1458300; 1458400;1458500 2020
Series/Registration number Year of construction
G series - hot air generator
Commercial denomination
Heating device
Intended use
Complies with directives
Harmonized standards reference
2006/42/EC
UE 2016/426
2014/35/EC
2014/30/EC
CE 51CS4822
Machine Directive (MD)
Gas Appliance Regulation (GAR)
Low Voltage Directive (LVD)
Electromagnetic Compatibility Directive (EMC)
EU Type Examination Certificate
EN 525:2009
EN 60335-1:2012 + A11:2014 + A13:2017
EN60335-2-102:2016
EN 61000-3:2013
EN 55014-1:2017
EN 55014-2:2015
AND AUTHORIZES
Marco Fantino
Nominative
Via Nazionale 80 12010 CN
Address Postal code Province
Cervasca Italia
City Country
TO COMPILE THE TECHNICAL FILE ON HIS BEHALF
Place and date of the document
The manufacturer
Cervasca, 01/03/2019
Firma
Function Administrator
DC N-001/2019/145

FRANCO srl Manual of use and maintenance G series
14
2 - INSTALLATION
2.1 Before installing
In order to start the hot air generator G series, the following conditions are required:
• connection to the electric power supply with voltage and frequency suitable for the machine and with grounding
and safety devices;
• connection to the suitable gas supply (see technical details);
The installation must meet the safety requirements
provided by local regulation in force.
Make sure that all the connections necessary to operate the equipment have been properly prepared.
2.2 Positioning
The hot air generator G series must be installed horizontally, with the gas supply connector
heading towards the ground.
Use 4 eyebolts to hang the machine while keeping it in the working position with a suitable
staffing system.
The location of the air heater must be determined by a competent
person and must take both the technical and current legislative
requirements into account, which may entail the obtaining of specific
authorisations (e.g. fire prevention).
The following conditions must be respected in any case:
oAny gas tanks must be used an stored in accordance with law
and regulations currently in force.
oThe location of the equipment must permit easy access for all
normal maintenance and control operations.
oThere must be continuous ventilation in the room where the air
heater is working.
oIt is forbidden to install the equipment near to inflammable
materials.
oIt is forbidden to leave any material less than 2 meters from the
equipment.
oIt is forbidden to reduce the size of the equipment’s Inlets and
outlets.
oIt is forbidden to install the equipment in places where there are
aggressive and/or inflammable atmospheric agents.
oIt is forbidden to install the equipment in corners where dust,
leafs and other such materials get deposited and which may
obstruct the passage of air.
oThe equipment has to be used in the temperature range present
in the chapter “technical data”.
oThe condensate formation within the equipment has to be avoided.
Installation of the machine must be done complying the safety distances
(law UNI EN ISO 13857/2008)

FRANCO srl Manual of use and maintenance G series
15
2.3 Electrical connection
The installation involves the use of a humidistat or a thermostat ON/OFF controlling the power
of the machine; it is still possible to use, alternatively, a switch ON/OFF, in this case the start
and stop of the machine must be done manually.
The choice, however, does not affect the installation procedure described below.
Electrical connections must be undertaken by specialized, experienced and trained
technicians, in accordance with the current legislation.
Ensure that the electricity supply specifications correspond to those indicated in the
in this manual.
It is obligatory that the device is grounded using an efficient ground line.
The installation must foresee a device enabled to disconnect the machine from the electric supply.
2.4 Gas supply connection
The G series generator comes complete with gas valve inside the machine’s electrical box.
The plug for the line connection is 1/2”.
The gas supply line’s pressure must be in compliance with the data indicated in the
following table;
Connect the supply tube to the pressure reducer, and the latter to the cylinder of LPG or
the CNG line;
Use a flexible tube with a maximum length of 2m and make sure that there are no
bottlenecks;
The system must be adapted to the characteristics of the equipment in use and comply
with the current regulations.
3 - OPERATION
3.1 Getting started
Before operating the generator, verify that:
1. All connections, both electrical and hydraulic, are made according to the instructions contained in this
manual;
2. The generator is free and clean;
3. The gas supply tap is open.
3.2 First start
- Check the correct air flow direction (Fig. 3.1);
- Make sure all wires are regularly placed and not caught or pulled by any object;
- Ensure that the gas connections are correct;
- Open the methane supply tap while making sure that there are no leaks along the load circuit
and that the pressure is in compliance with the technical specifications indicated in the tables.
WARNING!
During operation, some
parts of the machine may
reach high temperature!
Air Flow

FRANCO srl Manual of use and maintenance G series
16
3.3 Start and stop
The machine starts when the consent is given on the thermostatic socket contacts (see diagram sez.5.3) or, if
the thermostat was not used, when the electrical supply is connected to the fan and to the generator.
Close the valve tank or the gas supply in case of prolonged unuse of the machine.
System START sequence
Contact 1-2 of the thermostatic socket
is closed
KO
Wait until it becomes closed
OK
Gas valve test (3”)
KO
Block + light signaling
OK
Pressure switch test –NO contact is
open
KO
Wait until it becomes open
OK
Fan starts (give voltage to the motor)
Pressure switch test
Verify if contact NO is closed (4”)
KO
Block + light signaling
OK
Prepurge (3”)
Verify if flame detector
is not detecting the flame
KO
Block + light signaling
OK
Open gas valve and make spark
Verify the flame
KO
Block + light signaling
Flame –machine is working
During operation:
If for any reasons the pressure switch contact becomes open (no ventilation or insufficient ventilation)
the machine stops and a signaling light turns on.
If the flame is not detected, the machine makes 3 attempt to lit the burner, after that the machines stops
and a signaling light turns on.
If the thermostatic socket contact (1-2) becomes open, the machine stops, without signaling. When the
contact turns closed again the machine restart after doing the check sequence.
In order to reset the state of the machine, it is needed to hold the reset button for 2,5”, verify the malfunction
causes before (ventilation problems, no gas…).
The signaling light turns off and the start sequence is executed.
4 - MAINTENANCE
Before undertaking any maintenance,
disconnect the device from the
electricity and gas supply!
Periodically check the efficiency of the heating system and the correct functioning of the fan. Keep the machine
clean and prevent the accumulation of dirt. Periodically clean the internal grill and the generators’ body.
4.1 Cleaning
Periodically perform the following operations by ensuring that the machine is disconnected from the mains and
the gas supply is interrupted. Make sure the device is cold before cleaning.
To clean the internal parts remove the sefety nets of the generator by removing #4 screws M4.
Keep the body of the device and engine clean, by regularly using a soft mild cloth and a non-toxic and solvent-
free detergent. Do not rub too tightly and do not spill water on the components.
Do not use solvents.
In the presence of unusual noises and vibrations, check the tightness of screws and bolts.
Use only original spare parts by FRANCO s.r.l.

FRANCO srl Manual of use and maintenance G series
17
4.2 Replacement or cleaning of the nozzle
After making sure that the machine is stopped and cold, disconnect the electrical
and gas supplies. Remove with a hex wrench #7, the 4 screws holding the safety
net on the generator’s aspiration inlet.
With a 13mm hex wrench, unscrew the nozzle (fig.4.1), being careful not to drop
it into de burner or the machine (eventually, cover the hole temporarily).
Replace the old nozzle with a new one. Replace the safety net.
Verify the gas pressure before restarting the device.
NOZZLES
MODEL
GPL - G30 (28…30mbar)
Metano - G20 (20mbar)
codice
Ømm
Codice
Ømm
G36-25
8101510
2,4
8101643
4,3
G45-40
8101515
3,0
8101551
5,5
G56-65
8101525
4,2
- -
- -
G56-90
8101559
4,7
- -
- -
5 –TECHNICAL SPECIFICATIONS
5.1 Technical data
G36-25
G45-40
G56-65
G56-90
HEATING POWER
kW
25
40
65
90
kcal/h
21.496
34.394
55.890
77.386
AIR FLOW
m³/h
3.000
4.000
7.000
8.000
cfm
1.766
2.354
4.120
4.709
GAS CONSUMPTION
@ 1013 mbar/15°C
GPL
kg/h
1,82
2,91
5,09
6,55
Metano
m³/h
2,38
3,81
5,91
8,58
GAS PRESSURE
GPL
mbar
30 (G30)
37 (G31)
Metano
20 (G20)
ELECTRICAL DATA
Tensione
V
230 / 1~
230 / 1~
230 / 1~
230 / 1~
Frequenza
Hz
50
50
50
50
Corrente
A
1,2
1,3
1,8
4,0
ELECTRIC POWER
W
180
180
370
550
NOISE LEVEL ad 1m
dBA
73
71
71
71
FIELD OF WORKING
Temperature
°C
-15/+35
R.H.*
%
95
DIMENSIONS
A
mm
360
450
560
560
B
800
800
930
930
C
520
630
750
750
WEIGHT
kg
15
17
25
27
PACKAGE DIMENSIONS
L
mm
800
800
1200
1200
B
600
600
800
800
C
400
400
650
650
*@30°C not condensing
Nozzle
Nozzle-holder
13
Burner’s main
body

FRANCO srl Manual of use and maintenance G series
18
5.2 Wiring
All the wires used must be suitable to carry the current intensity (A) of the motor (par. 5.1).
Terminal’s screws must be accurately tightened.
Make sure that the electricity supply characteristics are exactly as shown in the table (par. 5.1).
Install a differential magnetic switch upstream of the device.
Protect with a suitable motor overload protection (par 5.1).
Make sure all connections are stuck on the box, the box cover is secured and that the screws
are tightened to ensure the necessary level of protection.
5.3 WIRING DIAGRAM G36-25 –G45-40

FRANCO srl Manual of use and maintenance G series
19
5.4 WIRING DIAGRAM G56-65 –G56-90
5.5 THERMOSTATIC SOCKET USAGE
G series hot air generators are provided of a thermostatic socket to control the ignition of the appliance.
The special cap (when inserted), enables the ignition of the generator.
Is it possible to start the ignition from remote, by closing a contact between pin 1 and 2 of the provided plug (e.g.
an ambient thermostat).
On the G56-65 and G56-90 versions is possible to enable just the ventilation by closing a contact between pin 1
and 3.
Thermostatic socket
VENTILATION
COMMON
HEATING

FRANCO srl Manual of use and maintenance G series
20
5.6 Spare parts
It is highly recommended to use only original spare parts.
Orders must be made by specifying what follows:
- Device model
- Reference of the piece (as indicated as follows)
- Quantity of items to be ordered
- Address of the client
Item
G36-25
code
G45-40
code
Qty.
Description
1
1201006
1301006
1
PROTECTION GRID
1.1
1203004
1203004
1
PROTECTION GRID FIXING KIT
2
1451500
1452500
1
BURNER COMPLETE WITH DISK
2.1
1203005
1203005
1
BURNER FIXING KIT
3
7302003
7302003
1
ELECTRODES
3.1
1257500
1257500
1
kit fissaggio ELECTRODES
4
8101510
8101515
1
NOZZLE LPG
8101643
8101551
1
NOZZLE NATURAL GAS
5
1404000
1404000
1
NOZZLE HOLDER with FLAT NUT
6
1451001
1452001
1
GENERATOR BODY
7
--
--
1
ELECTRIC BOX
(see the exploded view)
7.1
1203008
1303008
1
ELECTRIC BOX FIXING KIT
8
1451004
1452003
1
MOTOR BRACKET
8.1
1203006
1203006
1
fixing kit for motor bracket
9
5002001
5002001
1
VENTILATOR MOTOR
9.1
1203007
1203007
Motor fixing kit
10
5102011
5102012
1
FAN
10.1
1203009
1203009
1
Fan fixing kit
11
6002010
6002010
4
Eye bolt
This manual suits for next models
4
Table of contents
Other FRANCO Portable Generator manuals
Popular Portable Generator manuals by other brands

North American Tool
North American Tool 1250 XLT Important operating instructions

Benchmark
Benchmark BG Series user guide

SDMO
SDMO Kohler HX 3000 C Instruction and maintenance manual

Ryobi
Ryobi RYi6522 Operator's manual

Briggs & Stratton
Briggs & Stratton PRO4000 Operator's manual

Kusam-meco
Kusam-meco KM 2001 Operation manual