Important Notice
If you have any concerns about your health, or experience any pain
while nursing or using any breast pump, stop pumping immediately
and consult your health care or lactation professional immediately.
DAO Health does not give medical advice or lactation advice, make
diagnoses or recommend treatment.
WARNING: Never use your Freemie Closed System Collection Cups in
any location, situation or circumstances that are unsafe for you, your infant
or others.
Product Description
The Freemie Closed System Collection Cups are capable of single and
double pumping. The operating life of the Freemie Collection kit is
dened as 60 days.
Congratulations on your purchase and thank you for choosing
Freemie Closed System Collection Cups. Your Freemie cups are
designed to help make your pumping experience compatible with
your life, allowing you greater exibility to pump whenever and
wherever necessary.
Intended Use
The Freemie Closed System Collection Cups are designed to be used
only with a compatible breast pump to be used by lactating women to
express and collect milk from their breasts. The Freemie Closed System
Collection Cups are intended for use by a single user.
Contraindications For Use
There are no known contraindications for use of this product.

3
Table of Contents
Intended Use...............................................................................2
Contraindications for Use.............................................................2
Product Description......................................................................2
Important Safety Instructions.....................................................4-5
Freemie Closed System Collection Cups......................................6
Pump the Freemie Way................................................................7
Preparing Freemie for First Use....................................................8
Sanitizing......................................................................................8
Cleaning.......................................................................................9
Assembling Freemie Cups.........................................................10
Connecting to Your Freemie Compatible Pump.........................11
Positioning Within Your Bra...................................................12-14
Before Pumping with Freemie....................................................15
Pumping with Freemie................................................................16
Disconnecting and Transferring Your Milk..............................16-17
Proper Storage of Breast Milk...............................................17-18
Troubleshooting Tips...........................................................18-19
Warranty and Specications........................................................20
Spare Parts and Customer Service..............................................21

4
READ ALL INSTRUCTIONS BEFORE USING THIS PRODUCT.
This is a single user product. Use by more than one person may present a
health risk and will void the warranty.
•Do not use solvents or abrasives on any components.
•Do not put any Freemie components in the dishwasher or steam sterilize.
WARNING: To avoid health risk and reduce the risk of injury:
•Never use a damaged device. Replace damaged or worn parts.
•Never use if moisture or liquid is detected in pump’s tubing.
• Always inspect the exible tongue-shaped barrier (page 6) for damage
(cuts, tears, or holes). Use of a damaged barrier will cause milk to ow
into the tubing and pump motor. This can damage the pump motor and
compromise hygiene. Use of a damaged barrier will void your warranty.
•If pumping is uncomfortable or causing pain, turn the unit off and if
necessary break the seal between the breast and breast funnel immediately
with your nger and remove the breast funnel from your breast.
•Do not try to express with vacuum that is too high and uncomfortable
(painful). If all breast pumps are painful for you even on their lowest suction
settings, consider consulting with your lactation or health care professional.
•Always inspect funnels, cups, valve bases, duckbill valves, barriers, and
tubing prior to use for cleanliness.
•Clean, sanitize and dry all parts that come in contact with your breast and
breast milk prior to rst use. See page 8 and 9 for sanitization and
cleaning instructions.
•Disassemble, clean and dry all parts that come into contact with your breast
and breast milk after every use.
•Do not store wet or damp parts where mold may develop.
•Use Freemie Closed System Collection Cups only with Freemie
compatible pumps. Use with non compatible pumps may cause injury to
you or damage your pump. Misuse may void warranty. Visit Freemie.com for
the current compatibility list.
•As a general rule, use Freemie only as often and only as long as you normally
breastfeed your baby. Consult a lactation professional if you have questions
about your milk supply.
•Consult your lactation professional if you have questions about whether
Freemie is appropriate for you or to help determine the correct funnel size
for you.
• Freemie is not recommended if you must watch your milk ejection reex
or aggressively massage your breasts while pumping to ensure that they are
completely emptying.
Important Safety Instructions

5
Important Safety Instructions Continued
•Do not share. Freemie is a personal use item.
•Do not use Freemie for simultaneous breastfeeding and pumping with
compromised infants without rst consulting your healthcare or
lactation professional.
•Do not continue to use Freemie if you experience pain or discomfort in the
breast or nipple while pumping. Do not pump or pump and nurse in
situations or places that may present any risk to you or your infant.
•Keep out of reach of infants and children. Freemie has small parts that can
be choking hazards.
•If you are a mother who is infected with Hepatitis B, Hepatitis C or Human
Immunodeciency Virus (HIV), pumping breast milk will not reduce or remove
the risk of transmitting the virus to your baby through your breast milk.

6
Freemie Closed System Collection Cups
The Freemie Closed System Collection Cups include:
Collection Components
Connection Kit, Closed System (FG067)
(4) Breast Funnel,
Closed System
(2) 25mm (FG069)
(2) 28mm (FG070)
(2) Closed
System Barrier
(FG072)
(3) Tubing
(1) Y-Connector
(2) Valve Base,
Closed System
(FG071)
(3) Duckbill Valve,
Closed System
(FG073)
(2) Cup, Closed
System (FG068)

7
Pump the Freemie Way
Pump Efciently
Freemie can be used for single or
double pumping as desired.
Pump and Relax At
Home
You can close your eyes and sit in
the recliner and make baby’s milk
for tomorrow while tonight’s dinner
is in the oven!
Work
Pump discreetly at your work station
without ever undressing. Get your
work done and get home!
Milk contacting components not made with BPA, DEHP or natural
rubber latex.
Freemie® Collection Cup Features Overow Protection to Keep
Milk Out Of The Tubing!
Easy Pour Spout
8 Ounce
(240 mL)
Capacity
per cup
Tubing Connection
Port
Travel
Travel with Freemie to express your milk
on the go. Pump anytime, anywhere.
Pump While Bonding
Freemie can be used to pump milk
while breastfeeding. Place baby on one
breast and Freemie cup on the other.
Sleep in a little longer, and pump that
rst bottle of the day while baby lls up!
Internal Barrier
For Pump
Protection
Spill Guard Flat Base
Spill Guard
Finger Grip

8
Disassemble and clean Freemie Closed System Collection Cups prior to rst
use. Follow the instructions below to sanitize these parts.
Remove cup from funnel Remove barrer and
valve base from funnel
Sanitize Parts
Do not steam sterilize or dishwash any Freemie components. Doing so may
cause the parts to warp or not t securely and will void your warranty. Parts must
be thoroughly dry before use.
• DO NOT boil or steam these parts.
Hand wash only.
• Hand wash valve and barrier using
plenty of hot water and liquid
dishwashing soap, then rinse
clean with hot water for 10 - 15
seconds. Allow parts to cool and
dry completely before use.
Preparing Freemie for First Use
Boil These Parts
DO NOT Boil These Parts
Remove barrier and
valve from valve base
Breast Funnel
Natural Shape Cup
Valve Base
• Boil only these parts for 10 minutes to sanitize
and ensure parts t securely in an uncovered
pot. Covered pots or other systems that
trap steam can generate super heated
steam which may damage parts.
• Do not let parts sit on the bottom
of the boiling pot.
• Parts should oat freely.
• Carefully remove from water and be sure to
wash and dry parts after boiling.
Duckbill Valve
Tubing
Barrier
Y Connector

9
Do not steam or boil tubing, barriers or valves, as it will cause damage. Do
not put any Freemie components in dishwasher or steam sterilizer, as it can
cause parts to warp and leak. Before each use visually inspect the individual
components for cracks, chips, tears, discoloration or deterioration. In the event
that damage to the device is observed, please discontinue use until the parts
have been replaced.
Dry parts completely and leave parts disassembled
1. Disassemble and wash all components that come into contact with breast
milk (Cup, Breast Funnel, Valve, Valve Base, Barrier).
2. Hand wash parts using plenty of warm water and liquid dishwashing soap,
then rinse clean with hot water for 10 to 15 seconds. Allow part to cool and
dry completely before use.
3. Treat all parts with special care. Avoid abrasives and excessive heat.
Inspect the Closed System Barrier for rips or tears prior to each use. Rips or
tears will cause the Closed System Barrier to not function properly, possibly
causing damage to your pump. If the barrier has been compromised replace
prior to pumping.
4. Clean and dry as soon as possible after each use.
5. When not in use, store parts un-assembled and out of reach from infants
and children.
6. Do not store assembled Freemie parts in refrigerator, parts may become
loose or leak.
Regular Cleaning After Each Use

10
Assembling Freemie Closed System Collection Cups
Always wash hands prior to assembling Freemie Closed System Collection
Cups. All parts must be completely dry, correctly positioned, and pressed
securely together.
Inspect the device before each use for signs of wear or damage and replace
parts if signs of wear are noted.
Place Barrier onto funnel mounting
ridge and against cone surface.
Align Valve Base with Barrier and
Funnel and push together.
Press Breast Funnel and Valve Base
rmly together.
Align Cup arrow with Funnel tubing port,
seat cup rim into outer ring of funnel,
and snap together. You should feel a
crisp ‘snap,’ and then assembly is secure.
Place Valve onto Valve Base.
Step 1
Step 3
Step 5
Step 4
Step 2
Cup arrow
Note: Arrow on cup is difcult
to see but can be felt above
Freemie logo. Locate arrow
with your nger, and align it
to tubing port to assemble.
Align cup arrow
with Funnel tubing
port (circular)
Note: Do not align
arrow with pour
spout (egg-shaped)

11
Connecting to Your Freemie Compatible Pump
Single Pumping
Note: For all tubing connections, press in
rmly until you get a secure connection
Double Pumping
Close unused tubing
port with attached plug
(press all the way in)
AVOID SETUP FRUSTRATION BEFORE PLACING THE FREEMIE CUPS IN YOUR BRA: After the cups are
assembled and connected to the pump, turn on pump, and observe the tongue-shaped barrier inside
each cup. If all parts are assembled securely and correctly, you will be able to observe movement or
compression in the tongue-shaped barrier when the pump is running. At the highest suction settings,
the barrier will collapse and curl with each cycle, similar to the movement of your baby’s tongue while
sucking. If there is no movement in one or both cups, re-check the assembly and all tubing connections.
Freemie-Compatible Pumps
Freemie Liberty and Independence
Philips Twin Electric
Philips Comfort
Ameda Purely Yours
Ameda Purely Yours Ultra
Unimom Forte
Spectra M1
Spectra S1 Plus
Spectra S2 Plus
Spectra S1
Spectra S2
Spectra 9plus
Lucina Melodi Prime
ARDO Calypso
Eveno Advanced
Freemie-Compatible
Pump
Freemie-Compatible
Pump

12
Positioning Within Your Bra
Finding The Ideal Bra Fit For You
When getting started with your new Freemie Closed System Collection Cups,
be aware that bra t is critical to the proper use of this device because your
bra must now do the job that your hands would be required to do with a
traditional pump.
1. Before choosing a bra, pump with your new Freemie cups using your hands
to hold the Cups in place. Consider how much pressure you normally
apply against your breasts to pump and observe the optimal position and
orientation of the cups on each of your breasts. (Note most women are
not perfectly symmetrical, and improper positioning or pressure on one or
both breasts may result in low output. This may happen with any traditional
or hands free pumping systems if you do not spend the necessary time to
gure out how to make the pump work well and effectively for you, on each
of your breasts). This needed pressure may be different when your breasts
are engorged versus when they are empty. To achieve the same pressure
and sensation with the Freemie Cups in your bra, it may be necessary to
adjust your bra or try different bras to get the best t for you.
A sports bra works well for many women.
2. Be sure your bra keeps the Freemie cups in an upright position and does not
allow the device to slip around, sag downward, or tilt off to the side during
use as a loss of suction may occur.
3. Place Freemie inside your bra with the Breast Funnel opening centered over
the nipple.
4. Make sure you achieve a good seal between Freemie’s funnels and your skin.
Correct Nipple Position & Funnel Sizing
Ensure nipple is centered in the Breast Funnel and not bent or pinched off.
If the tip of the nipple hurts while expressing, check that the nipple is in the
center of the funnel.
Correct Position Incorrect Position

13
Positioning Within Your Bra Continued
Check Breast Funnel Fit
Turn on the pump and check the following points:
• Is the nipple rubbing or sticking against the side?
• Does the base of the nipple blanche during the expression session?
• Does it feel painful?
If the answer is ‘yes’ to any of the above, a different size funnel may be needed.
With properly tted breast funnels, the nipple moves in and out of the funnel
freely. The areolar tissue should move only a little and there should be no pain.
See our sizing guides at www.freemie.com. Note you may need a different size
funnel for each breast for an optimal pumping experience.
You need a different size if the provided funnels are too big or too small.
Too Small Too Large Correct Size
DAO Health cannot help you determine your correct funnel size by email or
phone. If you have questions about how to nd the right breast funnel size for
you, please consult with your lactation professional.
Funnel is too small for the
nipple to move freely in
and out of funnel causing
rubbing or chang.
Funnel is too big
allowing too much breast
and areolar tissue to be
drawn into funnel.
Funnel is correct size.
Additionally, enough
pressure needs to be
applied to create a good
seal without compressing
or obstructing milk
ducts. Bra t is critical to
allow comfortable and
effective pumping.
Internal Diameter
is measured across
the opening
25mm
28mm

14
Tubing Port Should Be In The 12 O’Clock Position
Positioning Within Your Bra Continued
When connected to a pump,
tubing port and pour spout must
be in the 12 o’clock position.
12
When lling with milk, keep in the
upright position.
Placement at any other position can
cause milk to ow out of cups while
you are pumping.
Tubing in 12
o’clock position.
Milk leaking
from cups.
Correct
Incorrect
Freemie-Compatible
Pump

15
Pump with Freemie Closed System Collection Cups in an upright position,
such as sitting or standing
You may pump in any of these positions. The position of the cups relative
to the horizon is important, as your milk needs to ow downhill in the funnel.
Note: Depending on the shape and orientation of your breasts, you may be
able to comfortably pump in a wide variety of positions.
Before Pumping With Freemie Breast Pump System
Optimal
Okay
May cause milk to spill Incorrect
May cause milk to spill

16
Pumping with Your Freemie Closed System
Collection Cups
As with any new pump, expect a period of adjustment to the hands free
and fully concealed pumping experience. After a few days using your Freemie
Closed System Collection Cups, review the instructions for bra and funnel t
to evaluate any needed adjustments. Consider what items in your wardrobe
work well and make you comfortable while pumping. You may also nd that
other people are more comfortable in your presence while you are pumping
with your clothes on, when compared to alternatives.
Each Freemie Cup holds 8 ounces (240 mL) of breast milk.
NOTE: When the Freemie Cups are full, turn off pump and pull tubing from
Freemie Cups while still wearing Freemie Cups in your bra. (See below, When
You Are Done Pumping)
If you produce more than 8 ounces (240 mL) per breast, stop pumping when
the Freemie Cups are full and empty each cup. If you have a second Freemie
Closed System Collection Set that is compatible with your pump, switch out full
Freemie Cups with empty Freemie Cups to minimize pumping interruptions.
Stop the pump
To stop the pump, shut it off or break the suction by inserting your ngers
between the funnels and your breasts if necessary. If you experience pain in
your breast or nipple, even if you think the pump is not the source of the pain,
consult your health care or lactation specialist.
When you are done pumping
1. Turn off pump.
2. Leave Freemie in your bra and gently pull the tubing from the device.
3. Carefully remove cups from your bra.
4. Freemie cups may be set at on a table until ready to transfer to a
storage container.
Disconnecting and Transferring Milk

17
Pouring Milk into a Container
Practice with water rst to achieve successful transfers without spilling -
it’s easy! Handle a full Freemie cup with care. Milk that has not passed through
the valve and into the cup can spill out of the Breast Funnel.
Use pour spout for transferring
milk into storage containers.
Pour Spout
Fully disassemble and clean immediately
after transferring milk to get ready for
next use. (Refer to page 9)
Proper Storage of Breast Milk
How long can I store breast milk?
Source: Proper Handling and Storage of Human Milk, cdc.gov
Location
Countertop, table
Insulated cooler bag
Refrigerator
Freezer
Freezer compartment
of a refrigerator
Freezer compartment
of a refrigerator with
separate doors
Chest or upright deep
freezer
Temperature
Room temperature
(up to 77°F or 25°C)
5-39°F or -15-4°C
39°F or 4°C
5°F or -15°C
0°F or -18°C
-4°F or -20°C
Duration
6-8 hours
24 hours
5 days
2 weeks
3-6 months
6-12 months
Comments
Containers should be cover and
kept as cool as possible; covering
the container with a cool towel may
keep milk cooler.
Keep ice packs in contact with
milk containers at all times, limit
opening cooler bag.
Store milk in the back of the main
body of the refrigerator.
Store milk toward the back of the
freezer, where temperature is most
constant. Milk store for longer
durations in the ranges listed is
safe, but some of the lipids in the
milk undergo degradation resulting
in lower quality.

18
How do I thaw and use stored breast milk?
• Always make sure to check the date on the milk’s container before using.
Do not use undated milk, or milk that has been stored too long.
• Thaw frozen milk in the refrigerator or under cool, running water.
• Heat the milk under warm, running water and gently swirl the container to
mix the milk.
• If warm water is not available, heat a pan of water on the stove. Once the
water is warm, not boiling, remove the pan from the stove and place the milk
container in the pan. Never warm the milk container directly on the stove.
• Never microwave breast milk because microwaves can cause dangerous hot
spots that could burn you or a baby.
• Always test the temperature of the milk on the inside of your wrist before
feeding it to a baby. The milk should feel warm, not hot.
• After thawing, milk should be stored in the refrigerator for no more than
24 hours.
• Never refreeze thawed milk. Throw away previously frozen milk that is not
used within 24 hours.
Breasts Not Emptying - Review Positioning Within Your
Bra, Page 12-14
• Always center Breast Funnel over nipple. If the Breast Funnel is off the
center of the nipple you may impede milk release, experience loss of suction,
or prevent the complete emptying of the breast.
• Try adjusting the position of Freemie cups. Comfortably position your
body to help create the best seal between Freemie cups and your skin.
Experiment with your body position by sitting up straighter, leaning forward
a little, or pulling your shoulders back.
• The Breast Funnels come in the standard 25mm and 28mm. Visit www.
Freemie.com for the latest in sizing options and accessories.
Note: If you require a funnel diameter or depth that we do not currently offer,
then unfortunately we do not recommend the Freemie system as your full
time pump.
• If problems emptying your breasts persist, consult your
lactation professional.
Troubleshooting Tips

19
Loss of Suction - Review Assembling Freemie Closed
System Collection Cups, Pages 10-11
• Make sure pump is turned on, motor is running, and suction level is turned up
to your regular setting.
• Make sure that parts are correctly assembled and t together as snugly as
possible, and that connection to the pump is secure. (see pages 9 and 10)
• If the t between the valve base and funnel is loose, try replacing the valve
base with a new valve base.
• If suction is diminished, try replacing the duckbill valve with a new
duckbill valve.
• Make sure tubing is not kinked or pinched. Make sure tubing is pushed
securely into its port on the breast funnel. (see page 11)
• Make sure Breast Funnel is securely pressed against breast creating a seal
around nipple, and is properly seated in bra. Check that no bra material or
tubing is between the device and your skin. The device should not be tilting
upward, downward, or to the side. (see pages 14 and 15)
• Make sure nipple is not bent or pinched inside the Breast Funnel. (see page 12)
• Try a tighter tting bra to ensure that the bra is able to support and maintain
an adequate seal and hold Freemie in an upright position. Consider trying a
sports bra. (see page 12)
• When single pumping, be sure Y-connector plug is on securely inserted into
open port. (see page 11)
• Ensure barrier is properly assembled.
• If pump is on, but no vibration is detected from pump even at highest
suction settings, contact pump manufacturer for customer service.
Milk in Tubing
• Ensure that all parts are rmly assembled and that barrier is not damaged.
Troubleshooting Tips Continued

20
Warnings
Note: The Freemie Closed System Collection Cups are Personal Use Items, and cannot be
returned once opened.
The Freemie Closed System Collection Cups are guaranteed against defects in materials
and workmanship for a period of 60 days. Warranty can only be claimed in the country of
purchase through authorized Freemie distributors. Warranty does not cover misuse, abuse
or excessive wear and tear. Spare parts are available at www.freemie.com. Plastic parts do
wear out with regular use, so plan ahead to avoid disruptions to your pumping routine. In
the event of a veriable defect that is not the result of misuse, abuse, excessive wear and tear
or alteration, Dao Health will replace or repair this product at Dao Health’s discretion. Returns
will not be accepted without a return merchandise authorization, which must be obtained
from Dao Health’s customer service. All shipping costs are the responsibility of the shipper.
Note: Failure to use and maintain the Barrier in good condition may cause damage to your
pump and will void your warranty. If milk ows into the tubing, turn off the pump immediately.
Refer to the user manual for instructions on cleaning or replacing tubing, replace Barrier.
Failure to turn off the pump when milk gets in the tubing will cause damage to your pump.
Warranty & Specications