9
Ordernewfilter cartridgesthrough the
dealer where you bought the
refrigerator, or contact the Frigidaire
Consumer Assistance Center at 1-800-
944-9044. It might be good to order
some filters when you first install your
refrigerator. Be sure to ask for the RC-
200 PureSource Plus™ replacement
cartridge.
Automatic Ice and
Water Dispenser(continued)
Changing the Filter:
Waterquality variesthroughouttheworld. Toensure thehighestpossible
water quality, change water filter every 6 months, or 200 gallons. Also, if
filter has been in a refrigerator that has not been in use for awhile (during
moving for example), change filter before reinstalling refrigerator. Note
dispenser system will also operate without filtration (with filter cartridge
removed).
To change filter:
RefertoFigure1asneeded.Itisnotnecessarytoturn the water supply off
to change the filter.
1. Set ice maker lever (wire signal arm) to the OFF (up) position.
2. Hold filter cup firmly, and unscrew counter clockwise (Figure 1). (Some
watercouldleakoutasyou removecup.Thisisnormal.) Filtercartridge
shouldcomedownwithcup. Ifcartridgeremainsinhousing,pulldown
gently, while twisting filter back and forth.
3. Empty cup of any substance.
4. The large o-ring (Figure 1) that seals the filter system sets in the o-ring
groove down inside the cup. Should the o-ring fall out during filter
cartridge replacement, simply place it back in the groove prior to
screwingthecupbackinplace.Iftheo-ringbecomesdamaged,youwill
need to order a new one from the Consumer Assistance Center.
5. Discard old filter cartridge.
6. Remove new filter cartridge from packaging, and install.
7. Place filter cartridge in cup. The end with the small o-ring should be up,
out of the cup.
8. Screw cup, with filter, back onto housing. Do Not Use Wrench To
ReinstallCup.Filtercartridgewillself-alignascupistightened.Besure
cup is completely tightened with PureSource Plus ™ Logo facing
outward.Do Not Tighten Past Stop.
9. Set ice maker level on the ON (down) position.
10.Checkforleaks.Openrefrigeratordoor.Wipeanywaterdropsfromthe
filtercup. Run a glassof water. If there is a leak,unscrew filter cup, and
reinsert the filter cartridge. Check placement of large O-ring (see
Figure1). Reinstall filter cup, making certain it is tightened completely.
11.To condition filter system and purge air from water line, run several
glasses of water through water dispenser. This will also assure that the
purest water possible is stored in water tank.
The PureSource Plus™ RF-200 ice and
waterfiltersystemistestedandcertified
by NSF International, the nationally
recognizedandrespected,notforprofit,
certification organization for public
health safety. The PureSource Plus™
system is tested and certified to ANSI/
NSF Standards 42 and 53. See
performance data sheet for specific
claims.Thissystemshouldnotbeusedon
waterthatis microbiologicallyunsafe or
with water of unknown quality unless
the water has been adequately
disinfected before or after traveling
through the filtration system.
Rated service flow- .37 GPM
Maximum Rated Pressure- 125 PSI
Maximum Operating Temp. - 100°Figure1