This display has been designed primarily for SDR Mastering / Monitoring applications.
HDR monitoring modes are provided as well and may be useful for short term client
review of HDR material. However, this display is not suggested for HDR mastering or
long term HDR monitoring as prolonged use of these modes can reduce the lifespan
of the display as well as have a negative impact on overall display performance.
Display of static content, overlays, OSD menu or scopes, may cause permanent
BURN-IN on the display’s OLED panel.
Length of time required for burn-in to develop varies due to many factors including
content and luminance level.
You should avoid displaying static content, especially in HDR mode for extended
periods of time.
To lessen the potential severity of burn-in the display will start to dim if a static
image is detected for 2 or more minutes. The display will return to normal operating
luminance when the image is refreshed (see Panel Dimming section of manual for
details). Panel dimming can be turned off, but additional caution should be exercised
if panel dimming is disabled.
A Clear Panel Noise capability is provided that can help restore panel performance
to some extent, but when possible care should be taken to avoid conditions that may
cause burn-in .
OLED PANEL BURN-IN WARNING

© 2022 Flanders Scientic, Inc.
4
Return to Table of Contents
Safety Precautions
Safety Precautions
• All operating instructions must be read and understood before the product is operated.
• These safety and operating instructions must be kept in a safe place for future reference.
• All warnings on the product and in the instructions must be observed closely.
• All operating instructions must be followed.
• Do not use attachments or accessories not recommended by the manufacturer. Use of inadequate
attachments may result in serious accidents.
• Do not place heavy objects on the power cord. Route power cord to prevent people from stepping
on or resting objects on the cord. Check to ensure that both outlet and product connection points
are properly seated and secured.
• This product must be operated on a power source as specied on the specication label or product
screening. Always operate the product within the voltage range specied.
• Do not overload AC outlets or extension cords. Overloading can cause re or serious electric shock.
• Never insert an object into the product through vents or openings as this can cause serious electric
shock or damage.
• Do not expose product to water or other liquids as this can lead to electrical shock or permanent
damage.
• Do not attempt to service the product yourself. Removing covers can expose you to high voltage
and other unsafe conditions. Please seek the assistance of a qualied service professional for all
service needs.
• If any of the following occur, unplug the power cord from the AC outlet and consult a qualied service
professional to perform repairs:
• Power cord or plug becomes damaged.
• When any liquid is spilled on or in the product.
• When the product has been exposed to rain or water.
• When the product does not operate properly as described in the instruction manual.
• When the product has been dropped or damaged.
• Keep this product away from heat generating sources such as radiators, heaters, stoves, or other
heat generating products.
Connecting and Disconnecting SDI BNC Cables
To prevent damage to components from electrical discharge follow these steps:
• Connect power rst on all devices.
• Power on all devices.
• Connect BNC cables.
To disconnect:
• Disconnect BNC cables.
• Power down and disconnect power from devices.
If using a wireless video receiver we strongly suggest using an SDI Video Ground Path Isolator
(available at ShopFSI.com and ShopFSI.eu) and powering the receiver from a separate power
source than the monitor. Use of wireless video receivers can cause dangerous ground loop issues
that can damage connected equipment like monitors. Using a ground loop isolator and powering
from a separate power source will help keep downstream equipment protected.

© 2022 Flanders Scientic, Inc.
5
Return to Table of Contents
Safety Precautions
• If the product requires replacement parts, make sure that the service person uses replacement
parts specied by the manufacturer, or those equivalent parts having the same characteristics and
performance specications as the original parts. Use of unauthorized parts can result in re, electric
shock, and/or other damage.
• Upon completion of any service or repair work, request that the service technician perform safety
checks to ensure that the product is in proper working order.
• When mounting the product to a wall, ceiling, or within a rack/enclosure, be sure to install the
product according to the instructions of both the mount and monitor manufacturer.
• Unplug the power cord from the AC outlet before cleaning the product.
• For proper screen maintenance please follow the guidelines below to prevent scratches, discoloration,
or other damage to the panel:
• Avoid striking the screen with any object.
• Do not wipe screen hard. Apply only gentle pressure if cleaning.
• Do not wipe the screen with solvents such as alcohol, paint thinner, or benzene as this can
cause permanent damage to the panel.
• Do not spray detergent or other cleaners directly on the monitor or panel.
• Do not write on the panel with any substance or object.
• Do not paste or stick anything to the screen as any adhesive can cause damage to the panel.
• Screen may be cleaned by gently wiping with lint free cloth to remove dust. For more thorough
cleaning use a lint free cloth that has been very lightly dampened with distilled water. Please
dry any excess moisture from the monitor or panel immediately to prevent damage.
• Take care in moving this product as serious injury or death can result from the sudden shifting or
falling of this object.
• The vents and openings in the product’s chassis are designed for ventilation. Do not cover, block, or
otherwise obstruct these vents and openings as insufcient ventilation can cause overheating and/
or shorten the life of the product. Do not place the object on a bed, sofa, rug, or other similar surface
as this can result in serious obstruction of ventilation areas. If using in enclosed space make sure to
provide proper ventilation to maintain allowable operating temperature range.
• The panel used in this product contains glass and can cause serious injury if broken. If the unit is
dropped or otherwise damaged take care to avoid possible injury by glass shards.
• Avoid prolonged exposure to direct sunlight as this can cause damage to the panel For proper
chassis maintenance please follow the guidelines below to avoid any potential damage:
• Do not wipe the chassis with solvents such as alcohol, paint thinner, or benzene.
• Do not expose the cabinet to any volatile substances.
• Do not allow prolonged contact with rubber or plastic.
• Apply only gentle pressure to chassis when cleaning.
• To clean use soft, lint free cloth to remove dust. A lightly dampened cloth, as described in the
screen maintenance section, may also be used to clean the chassis.

© 2022 Flanders Scientic, Inc.
6
Return to Table of Contents
FCC (Federal Communications Commission)
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interface when the
equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance
with the instruction manual, may cause harmful interference to radio communications.
Warning: Changes or modications not expressly approved by the manufacturer responsible for compliance void
the user’s authority to operate the equipment.
Safety Precautions

© 2022 Flanders Scientic, Inc.
7
Return to Table of Contents
Parts & Their Functions
• SDI 1: Used to select SDI Input 1 as the active Input.
• SDI 2: Used to select SDI Input 2 as the active Input.
• SDI 3: Used to select SDI Input 3 as the active Input.
• SDI 4: Used to select SDI Input 4 as the active Input.
• DP: Reserved for possible future use, currently inactive.
• F1: Assignable function key. This key’s function is selectable from the Function Menu.
• F2: Assignable function key. This key’s function is selectable from the Function Menu.
• F3: Assignable function key. This key’s function is selectable from the Function Menu.
• F4: Assignable function key. This key’s function is selectable from the Function Menu.
• F5: Assignable function key. This key’s function is selectable from the Function Menu.
• MENU / LEFT: Used to toggle and navigate On Screen Menu.
• UP: Used to navigate On Screen Menu.
• DOWN: Used to navigate On Screen Menu.
• RIGHT / ENTER: Used to navigate On Screen Menu and to conrm selections within the On
Screen Menu.
• PHASE / H POS: Used to adjust hue higher or lower. Pressing down on the center of this button
will return the hue setting to its default position.
• CHROMA / V POS: Used to adjust chroma higher or lower. Pressing down on the center of this
button will return the chroma setting to its default position.
• BRIGHT / Ref POS: Used to adjust brightness higher or lower. Pressing down on the center of
this button will return the brightness setting to its default position. The brightness knob should
NOT be used increase the overall peak white luminance of the unit, use the Luminance setting to
adjust overall luminance.
• CONTRAST / F Stop: Used to adjust contrast higher or lower. Pressing down on the center of this
button will return the contrast setting to its default position.
• VOLUME: Used to adjust volume. Press down on this knob to instantly mute or unmute the
volume.
• POWER: Used to turn power ON / OFF.
Keyboard

© 2022 Flanders Scientic, Inc.
8
Return to Table of Contents
Parts & Their Functions
• SDI In: 4 Multi-Format 12G/6G/3G/HD-SDI
Inputs.
• SDI Out: 4 Looped 12G/6G/3G/HD-SDI
Outputs.
• MON Out: Processed output.
Follows Mode Selection.
• DP In: Reserved for possible furture use,
currently inactive.
• Audio In/Out: Analog Stereo Mini-phono Au-
dio Input & Output. Unbalanced, Audio Out
delayed by exact amount of monitor video
processing time to maintain sync.
• USB Type A: USB power, can be used to
power MediaLight Bias Lights.
• RS-485: RS-485 Ports (In/Out) for looping
remote control interface.
• LAN: IP Control via select programs.
Back Panel

© 2022 Flanders Scientic, Inc.
9
Return to Table of Contents
Menu
Navigating the Menu
Pressing the MENU button on the monitor’s keypad will call up the on screen menu. To navigate use
the UP and DOWN buttons and press the ENTER button to select the highlighted sub menu. Navigate
the sub menu in the same way by using the UP and DOWN buttons to highlight a particular function
and press ENTER to change that function’s settings. To exit the menu or back out of a sub menu press
the MENU button.
Menus longer than the Main Menu may not fully display. These menus will scroll. Use the Up and
Down keys to scroll up and down a menu.
Function Menu
Function F1 Luminance Scope
Scope F2 Vector Scope
Video F3 Pixel Mapping
Color F4 LUM Coloring
System F5 Area Marker
OSD Safety Marker
Center Marker
Load Prole 0
Load Prole 1
Load Prole 2
Load Prole 3
Load Prole 4
Load Prole 5
The Function Menu allows you to assign user selectable functions to any of the 5 function buttons (F1,
F2, F3, F4, and F5) on the monitor keypad. To assign a function to a function key, highlight one of the 5
functions and press ENTER. A list of assignable functions will appear. Select the desired function with
the UP and DOWN buttons and press ENTER.
Area Marker
Use the Area Marker function to select what type of marker is displayed when the marker function is
active. The marker selections available from this option include most commonly used markers and
more complex user designed custom markers.
Safety Marker
Use the Safety Marker function to toggle the size, in percentage, of the safety marker displayed. This
option can be used by itself or in conjunction with the Area Marker function.
Center Marker
Toggles whether the center marker (cross-hair) is displayed when the marker is activated.

© 2022 Flanders Scientic, Inc.
10
Return to Table of Contents
Menu - Function Menu
Function Menu
Function F1 Luminance Scope
Scope F2 Vector Scope
Video F3 Pixel Mapping
Color F4 LUM Coloring
System F5 Area Marker
OSD Safety Marker
Center Marker
Load Prole 0
Load Prole 1
Load Prole 2
Load Prole 3
Load Prole 4
Load Prole 5
Load Prole
Saved prole congurations can now be loaded via function button. This acts as a “load” button only
as opposed to a toggle, so pressing a corresponding Function button twice does not revert to previous
pre-load state.
Please note: to avoid circular logic problems, loading prole congurations does NOT change
function button assignments. The function buttons are independent of the prole congurations.

© 2022 Flanders Scientic, Inc.
11
Return to Table of Contents
Menu - Scope Menu
Scope Menu
Function Luminance Off
Scope Lum Position Bottom Right
Video Lum Style IRE
Color Vector Off
System Vec Position Bottom Right
OSD Lum Coloring Off
Lum & Vec Position
Use Lum & Vec Position to select in what area of the screen you would like your Scopes to be displayed.
Lum Style
Select IRE or HDR (PQ) Waveform. Note: HDR Waveform currently only works with YCbCr formats.
Lum Coloring (Customizable Exposure Check)
Generates an articial luminance map of the incoming source that can be particularly useful in identifying
overexposed areas in any given shot. An onscreen scale helps indicate what articial color corresponds
to what luminance from 0 to 100 percent.
You can change the range of these color coded regions to any preferred setting by using the monitor’s
rotary knobs. The H POS rotary knob will adjust the lower limit of the lower color coded region. The V
POS rotary knob will adjust the upper limit of the lower color coded region. The Ref POS rotary knob
will adjust the lower limit of the upper color coded region. The F Stop Rotary knob will adjust the upper
limit of the upper color coded region. These color coded ranges are retained in memory so you can exit
and reenter Lum Coloring Mode without having to reset your desired threshold levels.
Note: Scopes only work in Normal LUT Mode. Scopes will not operate in Advanced LUT Mode.

© 2022 Flanders Scientic, Inc.
12
Return to Table of Contents
Menu - Video Menu
Video Menu
Function Input SDI 1
Scope Mode AUTO
Video SDI Format AUTO
Color Pixel Mapping OFF
System Deinterlace Mode Mode 2
OSD
SDI Format
Select the correct incoming signal format. SDI Format selection overrides payload ID if not set to AUTO.
Mode
The mode selection allows you to set the SDI input conguration as well as the processed monitor
output conguration. Please note that the output conguration only impacts the outputs labeled MON,
the standard OUT connections are always clean loop throughs of whatever is being received by the
display. Note that when using a down-conversion conguration UHD will be down-converted to HD and
4K will be down-converted to 2K. All 2K and HD down-converted signals will be output to all 4 MON
outputs so the down-conversion may be accessed from any of these connections.
Available MODE options
AUTO: attempts to automatically identify signal type, particularly useful if simply switching between
single-link 1.5Gbps, 3Gbps, 6Gbps, and 12Gbps SDI signals formats.
6G_IN: single-link 6Gbps SDI input, single-link 6Gbps SDI output
6G_IN HD_OUT: single-link 6Gbps SDI input, 1.5Gbps HD output
6G_DL_IN: dual-link 6Gbps SDI input, dual-link 6Gbps SDI output
6G_DL_IN 3G_OUT: dual-link 6Gbps SDI input, single-link 3Gbps SDI Level A output
12G_IN: single-link 12Gbps SDI input
12G_IN 3G_OUT: single-link 12Gbps SDI input, single-link 3Gbps SDI Level A output
3G_DL-IN: dual-link 3Gbps SDI Level B input, dual-link 3Gbps SDI Level B output
3G_IN: single-link 3Gbps SDI input scaled full screen
HD_IN: single-link 1.5Gbps SDI input scaled full screen
3G_INx4: quad 3Gbps SDI input from inputs 1,2,3,4 to form UHD/4K signal on screen
HD_INx4: quad 1.5Gbps input from inputs 1,2,3,4 to form UHD/4K signal on screen
4K and UHD over 3G dual-link, 3G quad-link, and 1.5G quad-link should be formatted as Square
Division (SQ). Two Sample Interleave (2SI) support is tentatively planned for a future release.
Deinterlace Mode
Mode1: Combines elds and displays as progressive scan image.
Mode2: Shows on screen as interlaced with correct eld order.

© 2022 Flanders Scientic, Inc.
13
Return to Table of Contents
Menu - Video Menu
Video Menu
Function Input SDI 1
Scope Mode AUTO
Video SDI Format AUTO
Color Pixel Mapping OFF
System Deinterlace Mode Mode 2
OSD
Pixel Mapping
Pixel Mapping toggles between various available pixel mapping options including:
OFF
With Pixel Mapping set to OFF the incoming source is scaled to ll as much of the screen as
possible while preserving aspect ratio. If the incoming source and panel share the same resolution
then there will be no difference between OFF and the other pixel mapping modes.
Center
Maps the signal 1:1 with the center of incoming video in the middle of the screen.
Top Left
Maps the signal 1:1 with the top left incoming video in the top left of the screen.
Top Right
Maps the signal 1:1 with the top right of incoming video in the top right of the screen.
Bottom Left
Maps the signal 1:1 with the bottom left of incoming video in the bottom left of the screen.
Bottom Right
Maps the signal 1:1 with the bottom right of incoming video in the bottom right of the screen.
Note: Using pixel mapping with a 4K source on a native 3840x2160 screen will cause a portion of video
to not be displayed, but these modes can be used to display 4K signals 1:1 and view the Left, Right, or
Center of the video signal.

© 2022 Flanders Scientic, Inc.
15
Return to Table of Contents
Menu - Color Menu
Color Menu
Function ColorSystem User
Scope LUT Mode Normal
Video Range SMPTE Full 4-1019
Color Gamut BT.709
System Temperature Default
OSD EOTF Gamma 2.4
Luminance Mode 100
Luminance Custom 45
ColorSystem
The monitor features 5 Color System selections: DEFAULT, GaiaColor, LightSpace, CalMAN, and
NONE. On the XM652U, XM651U, XM650U, XM552U, and XM551U the factory calibrations are
stored in the DEFAULT Color System. LightSpace and CalMAN Color System options are provided
as additional memory place holders to store custom end-user calibrations using LightIllusion
(LightSpace / ColourSpace) or CalMAN calibration software. The GaiaColor selection is reserved for
future development and should not be used at this time on XM WOLED displays. Please leave the
ColorSystem set to Default unless you have specically saved your own user generated calibration
LUTs to the LightSpace or CalMAN memory banks.
LUT Mode
Does not apply to GaiaColor Color System. In Default, LightSpace, or CalMAN modes select Normal
or Advanced. Normal Mode enables both calibration and look LUT positions. Advanced Mode provides
larger cLUT size support, but limits look LUT and ancillary feature support (e.g. scopes).
In Normal Mode 6 LUT positions are accessible at a time as follows:
Front DIT 1D LUT -> DIT 3D LUT -> Post DIT 1D LUT-> Front Calibration 1D LUT -> Calibration 3D LUT
-> Post Calibration 1D LUT
In Normal Mode all 1D LUTs are 4096 entry point using 12bit values in the Flanders.lut format and all
3D LUTs are 17x17x17.cube format using only the header LUT_3D_SIZE 17.
The DIT LUT positions should be used for technical transforms or look LUTs, calibration LUTs should
normally only be stored in the Calibration LUT positions.
In Advanced Mode 3 LUT positions are accessible at a time as follows:
Front Calibration 1D LUT -> Calibration 3D LUT -> Post Calibration 1D LUT
In Advanced Mode all 1D LUTs are 4096 entry point using 12bit values in the Flanders.lut format and
the 3D LUT is 33x33x33.cube format using only the header LUT_3D_SIZE 33.
LUTs can be saved to the display using the IP Remote Utility.
Application Note: LUTs are applied within the range active on the monitor’s color menu.

© 2022 Flanders Scientic, Inc.
16
Return to Table of Contents
Menu - Color Menu
Color Menu
Function ColorSystem User
Scope LUT Mode Normal
Video Range SMPTE Full 4-1019
Color Gamut BT.709
System Temperature Default
OSD EOTF Gamma 2.4
Luminance Mode 100
Luminance Custom 45
Gamut
Select from available options to instantly change the active color space. This will enable both the 3D
Calibration LUT and 1D Calibration LUT positions stored to the corresponding memory bank.
Luminance Custom
Allows for custom peak luminance selection in 5nit increments when Luminance Mode is set to
CUSTOM. If Luminance Mode is not set to CUSTOM this menu item will simply reect the Luminance
Mode selected.
Luminance Mode
Select from CUSTOM or the 100, 200, 400, 800, or HDR quick access selections. When set to CUSTOM
the Luminance menu item above Luminance Mode will allow you to specify your preferred custom peak
luminance setting. For HDR use you must select the HDR luminance setting, which enable the panel’s
HDR boost mode.
Please note that when set to LUM 800, only the 3D Calibration LUT position will remain active,
the 1D LUT will revert to Unity in this selection.
Range
Video Range 64-940
Extended Video Range 64-1019
SMPTE Full Range 4-1019
Full Range 0-1023
Temperature - Only applies in GaiaColor mode / Reserved for Future Use.
EOTF - Only applies in GaiaColor mode/ Reserved for Future Use.

© 2022 Flanders Scientic, Inc.
17
Return to Table of Contents
Menu - Color Menu
Color Menu
Function ColorSystem User
Scope LUT Mode Normal
Video Range SMPTE Full 4-1019
Color Gamut BT.709
System Temperature Default
OSD EOTF Gamma 2.4
Luminance Mode 100
Luminance Custom 45
Red / Green / Blue Gain and Bias settings
White balance may be adjusted / customized from one of the Temperature selection presets using the
custom Red, Green, Blue Gain and Bias settings.
Factory Alignment Reset
This setting deletes the Factory AWB calibration. Do not use this setting unless you have the proper
equipment to redo the factory AWB calibration.
Basic settings for the most commonly used conguration on the XM652U, XM552U, XM551U,
XM650U, and XM651U are provided below:
For Rec709 2.4 SDR
Color System: Default
LUT Mode: Normal
Range: Video Range 64-940
Gamut: BT.709
Luminance Mode: 100
For P3-ST2084
Color System: Default
LUT Mode: Normal
Range: Video Range 0-1023
Gamut: P3-ST2084
Luminance Mode: HDR
Please note that in the DEFAULT Color System if factory LUTs have not been overridden the gamut
option DCI P3 will target a DCI white balance of x=0.314, y=0.351 while the P3-ST2084 option will
target a white balance of x=0.3127, y=0.3290.

© 2022 Flanders Scientic, Inc.
18
Return to Table of Contents
Menu - System Menu
System Menu
Function Update Firmware Allow
Scope Current IP 192.168.1.100
Video Version 2.1.20
Color Serial Number XM310A0000
System Payload ID 0000
OSD Prole Load
Prole Save
Set Static IP 192.168.1.100 192.168.1.100
IP Reset DHCP 255.255.255.0
Clear Panel Noise Off 192.168.1.1
Panel Dimming On Apply Settings
Update Firmware
When left to Allow (default) allows rmware to be remotely updated using the FSI IP Remote Utility.
When set to Block prevents rmware from being remotely updated.
Current IP
Shows monitor’s current IP address.
Version
Displays the current rmware version.
Serial Number
Displays the unit’s serial number.
Prole Load
Load a saved conguration by selecting it from the list. Congurations 1 through 5 are user adjustable
using the the Prole Save menu item. The Default Conguration returns settings to factory default of:
Color System: Default
LUT Mode: Normal
Range: Video 64-940
Gamut: BT.709
Luminance: 100
Gain/Bias Adjustments: 0 (neutral)
Prole Save
Select a conguration position to save all current monitor settings to that conguration slot.

© 2022 Flanders Scientic, Inc.
19
Return to Table of Contents
Menu - System Menu
System Menu
Function Update Firmware Allow
Scope Current IP 192.168.1.100
Video Version 2.1.20
Color Serial Number XM310A0000
System Payload ID 0000
OSD Prole Load
Prole Save
Set Static IP 192.168.1.100 192.168.1.100
IP Reset DHCP 255.255.255.0
Clear Panel Noise Off 192.168.1.1
Panel Dimming On Apply Settings
Set Static IP
Allows you to set a static IP address, subnet mask, and gateway address.
While setting an IP using the on-screen keyboard, use the monitor’s Up, Down, Menu, and Enter keys
to navigate the keyboard. You can also use the H Pos and V Pos rotary knobs. Pressing the H Pos or
V Pos rotary knobs will make a selection of the highlighted on-screen key.
IP Reset
Re-enable DHCP after a static IP address has been used.
Clear Panel Noise
The Clear Panel Noise feature may help to alleviate various panel noise conditions, particularly severe
burn-in conditions caused by displaying static, high contrast, content for extended periods of time.
Select On
Panel will display black and remain on for approximately 8 minutes.
After 8 minutes the monitor will automatically shut down.
After unit shuts down please leave the monitor turned Off for 1 hour.
After 1 hour press the power button to turn the monitor back on.
The display will remain black for 15 seconds after boot up, then a white line will appear on screen
and slowly scan down the panel.*
Once the scan is complete the monitor will automatically be ready for use.
*this step may vary slightly depending on specic model in use
Panel Dimming
When panel dimming is set to On the panel will automatically begin to dim after 2 mins of static color
and/or shape is detected to help protect the panel from image retention. Panel dimming can be set
to Off to disable this behavior and this may be particularly useful during calibration routines, but care
should be taken to avoid long term display of static images.

© 2022 Flanders Scientic, Inc.
20
Return to Table of Contents
Menu - OSD Menu
OSD Menu
Function Time Code Off
Scope Status Position Top Left
Video Status Set 5s
Color Menu Position Top Left
System Menu Set 5s
OSD Area Marker Off
Safety Marker Off
Center Marker Off
Time Code
Allows you to select whether to display Time Code on screen pulled from an SDI signal. Reserved for
future use, currently inactive.
Menu & Status Position
Changes position of on-screen menu and signal status display.
Menu Set
Set menu to automatically disappear after 5s, 10s, or to stay On until manually cleared.
Status Set - Signal Status ID window
Select from On, Off, or 5 second display. When set to 5 second display the monitor will display signal
status ID window for 5 seconds whenever an input button is pressed or signal format is changed.
The rst line of the signal status ID window shows the user selected primary input and video mode
(default is Auto).
The second line shows the primary input’s detected bandwidth (e.g. 12G), resolution (e.g. 3840x2160),
and scan type (e.g PsF). Please note that if your video mode is set to something besides a single wire
format (e.g. Quad Link SDI) this second line will only show the detected bandwidth and resolution of
the primary (selected) input. A quad link SDI UHD signal will therefore only indicate the resolution of the
primary quadrant (HD) whereas a single 12G-SDI UHD signal will show 3840x2160 resolution.
The third line indicates the frame rate, whether the signal is RGB or YCbCr, and the signal bit depth.
Please note that this information is based on received VPID. If VPID is incorrect or missing you may
manually override using the Video Menu’s SDI format selection, but this line will continue to reect
signal type as indicated by VPID.
This manual suits for next models
4
Other FSI Monitor manuals