FSI BM Series User manual

Monitor User Manual
Updated 5.6.2015
Flanders Scientic, Inc.
6215 Shiloh Crossing
Suite G
Alpharetta, GA. 30005
Phone: +1.678.835.4934
Fax: +1.678.804.1882
E-Mail: Support@FlandersScientic.com
www.FlandersScientic.com
BM Series CM Series
BM090 CM171
BM210 CM172
BM230 CM240
BM240 CM250
CM320TD
CM420TD
CM500TD
This manual is based on rmware version 1.1.00-1973. If you
have an older or newer rmware version some of the functions
mentioned in this manual may not be present or may operate
differently.

© 2015 Flanders Scientic, Inc.
2
Return to Table of Contents
Contents
TOPIC PAGE(S)
Safety Precautions 3-4
Parts & Their Functions 5-6
Menu Navigation / System Status 7
Function Menu 8-19
Marker Menu 20
Video Menu 21-22
Scopes & VU Meters Menu 23-25
System Menu 27-28
Alarm Menu 29-31
OSD Menu 32
GPI Menu 33
Audio Menu 34
Color Management Menu 35
Color Management Menu: DIT LUTs 36-37
Color Management Menu: Custom Calibration LUTs 38-41
Troubleshooting Guide 42-43
Monitor Specications 44-47

© 2015 Flanders Scientic, Inc.
3
Return to Table of Contents
Safety Precautions
• All operating instructions must be read and understood before the product is operated.
• These safety and operating instructions must be kept in a safe place for future reference.
• All warnings on the product and in the instructions must be observed closely.
• All operating instructions must be followed.
• Do not use attachments or accessories not recommended by the manufacturer. Use of inadequate attachments may
result in serious accidents.
• Do not place heavy objects on the power cord. Route power cord to prevent people from stepping on or resting objects
on the cord. Check to ensure that both outlet and product connection points are properly seated and secured.
• This product must be operated on a power source as specied on the specication label or product screening. Always
operate the product within the voltage range specied.
• Do not overload AC outlets or extension cords. Overloading can cause re or serious electric shock.
• Never insert an object into the product through vents or openings as this can cause serious electric shock or damage.
• Do not expose product to water or other liquids as this can lead to electrical shock or permanent damage.
• Do not attempt to service the product yourself. Removing covers can expose you to high voltage and other unsafe
conditions. Please seek the assistance of a qualied service professional for all service needs.
• If any of the following occur, unplug the power cord from the AC outlet and consult a qualied service professional to
perform repairs:
• Power cord or plug becomes damaged.
• When any liquid is spilled on or in the product.
• When the product has been exposed to rain or water.
• When the product does not operate properly as described in the instruction manual.
• When the product has been dropped or damaged.
• If the product requires replacement parts, make sure that the service person uses replacement parts specied by the
manufacturer, or those equivalent parts having the same characteristics and performance specications as the original
parts. Use of unauthorized parts can result in re, electric shock, and/or other damage.
• Upon completion of any service or repair work, request that the service technician perform safety checks to ensure that
the product is in proper working order.
• When mounting the product to a wall, ceiling, or within a rack/enclosure, be sure to install the product according to the
instructions of both the mount and monitor manufacturer.
• Unplug the power cord from the AC outlet before cleaning the product.
• For proper screen maintenance please follow the guidelines below to prevent scratches, discoloration, or other damage
to the panel:
• Avoid striking the screen with any object.
• Do not wipe screen hard. Apply only gentle pressure if cleaning.
• Do not wipe the screen with solvents such as alcohol, paint thinner, or benzene as this can cause permanent
damage to the panel.
• Do not spray detergent or other cleaners directly on the monitor or panel.
• Do not write on the panel with any substance or object.
• Do not paste or stick anything to the screen as any adhesive can cause damage to the panel.
• Screen may be cleaned by gently wiping with lint free cloth to remove dust. For more thorough cleaning use a
lint free cloth that has been very lightly dampened with distilled water. Please dry any excess moisture from the
monitor or panel immediately to prevent damage.

© 2015 Flanders Scientic, Inc.
4
Return to Table of Contents
Safety Precautions
• For proper chassis maintenance please follow the guidelines below to avoid any potential damage:
• Do not wipe the chassis with solvents such as alcohol, paint thinner, or benzene.
• Do not expose the cabinet to any volatile substances.
• Do not allow prolonged contact with rubber or plastic.
• Apply only gentle pressure to chassis when cleaning.
• To clean use soft, lint free cloth to remove dust. A lightly dampened cloth, as described in the screen maintenance
section, may also be used to clean the chassis.
• Take care in moving this product as serious injury or death can result from the sudden shifting or falling of this object.
• The vents and openings in the product’s chassis are designed for ventilation. Do not cover, block, or otherwise obstruct
these vents and openings as insufcient ventilation can cause overheating and/or shorten the life of the product. Do not
place the object on a bed, sofa, rug, or other similar surface as this can result in serious obstruction of ventilation areas.
If using in enclosed space make sure to provide proper ventilation to maintain allowable operating temperature range.
• The panel used in this product contains glass and can cause serious injury if broken. If the unit is dropped or otherwise
damaged take care to avoid possible injury by glass shards.
• Keep this product away from heat generating sources such as radiators, heaters, stoves, or other heat generating
products.
• Avoid prolonged exposure to direct sunlight as this can cause damage to the panel
FCC (Federal Communications Commission)
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interface when the
equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance
with the instruction manual, may cause harmful interference to radio communications.
Warning: Changes or modications not expressly approved by the manufacturer responsible for compliance void
the user’s authority to operate the equipment.

© 2015 Flanders Scientic, Inc.
5
Return to Table of Contents
Parts & Their Functions
• SDI 1: Used to select SDI Input 1 as the active Input.
• SDI 2: Used to select SDI Input 2 as the active Input.
• YPbPr: Used to select the Component Analog Input as the active Input.
• VIDEO: Used to select the Composite Analog Input as the active Input.
• DVI: Used to select the DVI-I Input as the active Input. DVI-Digital / DVI-Analog toggle is available in the System Menu
(Menu/System/DVI Selection).
• F1: Assignable function key. This key’s function is selectable from the Function Menu.
• F2: Assignable function key. This key’s function is selectable from the Function Menu.
• F3: Assignable function key. This key’s function is selectable from the Function Menu.
• F4: Assignable function key. This key’s function is selectable from the Function Menu.
• F5: Assignable function key. This key’s function is selectable from the Function Menu.
• MENU: Used to enable On Screen Menu.
• UP: Used in combination with DOWN and ENTER Keys to navigate On Screen Menu.
• DOWN: Used in combination with UP and ENTER Keys to navigate On Screen Menu.
• ENTER: Used in combination with UP and DOWN Keys to navigate On Screen Menu. The ENTER button is used to
conrm selections within the On Screen Menu.
• POWER: Used to turn power on/off.
• VOLUME: Used to adjust volume. Press down on this knob to instantly mute or unmute the volume.
• CONTRAST: Used to adjust contrast higher or lower. Pressing down on the center of this button will return the contrast
setting to its default position.
• BRIGHT / F.D. / Ref POS: Used to adjust brightness higher or lower. Pressing down on the center of this button will
return the brightness setting to its default position. The brightness knob should NOT be used increase the overall peak
white luminance of the unit, use the Luminance setting on the System Menu to adjust overall luminance.
• CHROMA / V POS: Used to adjust chroma higher or lower. Pressing down on the center of this button will return the
chroma setting to its default position.
• PHASE / H POS: Used to adjust phase. Pressing down on the center of this button will return the setting to default. Hue
is locked by default on SDI, but can be unlocked by the SDI Hue Adjustment option on the System Menu.
• Tally: Three color tally lamp controlled via remote control.
DVI
VIDEO
YPbPr
SDI 2
SDI 1
F1
F2
F3
F4
F5
ENTER
UP
MENU
DOWN
PHASE / H POS
CHROMA / V POS
BRIGHT / Ref POS
CONTRAST / F Stop
VOLUME / Reset
POWER

© 2015 Flanders Scientic, Inc.
6
Return to Table of Contents
Parts & Their Functions
• LAN: IP Control via select programs. This feature is in beta.
• GPI: General Purpose Interface for Contact Closure Remote Control.
Remote Control Functions can be assigned from the GPI Menu.
• RS-485: RS-485 Ports (In/Out) for looping remote control interface.
• DVI-I: DVI-I Input. Supports both DVI-Analog & DVI-Digital.
Analog / Digital Toggle is found on System Menu.
• Video In/Out: Composite Video Input & Loop Through.
• Component In/Out: Component Video (SD & HD autosensing) Input & Loop
Through.
Supports both YPbPr & RGB signals.
• Ext. Sync. In/Out: External Reference Synchronization Interface.
• SDI In 1 & SDI In 2: Two Autosensing, Autoswitching, Multi-Format 3G/Dual-Link/
HD/SD-SDI Inputs.
• SDI Out 1 & Out 2: Two looped 3G/Dual-Link/HD/SD-SDI Outputs.
• Audio In/Out: Analog Stereo Mini-phono Audio Input & Output. Unbalanced, Audio
Out delayed by exact amount of monitor video procesisng time to maintain sync.
DC Power
AC Power
100mm VESA
LAN
RJ-485
GPI
RS-232
DVI-I
Video
Component
SDI
Ext Sync
Audio

© 2015 Flanders Scientic, Inc.
7
Return to Table of Contents
Menu Navigation / System Status
Main Menu
Pressing the MENU button on the monitor’s keypad will call up the On Screen Menu, as shown below:
Main Menu Function
Function F1 Scopes & Audio Meters 1
Scopes & Audio Meters F2 Scopes & Audio Meters 2
Video F3 Scopes & Audio Meters 3
Audio F4 Marker 1
Marker F5 Measurement (10Bit)
System Function Display On
Alarm
OSD
GPI
Color Management
System Status
Support
Navigating the Main Menu
To navigate the Main Menu simply use the UP and DOWN keys to highlight a category and press the ENTER button to
select the highlighted sub menu. Navigate the sub menu in the same way by using the UP and DOWN keys to highlight a
particular function and press ENTER to toggle between that function’s settings. To exit the menu or back out of a sub menu
simply press the MENU button.
System Status Category
The System Status category does not contain any congurable settings, but does provide important information regarding
your monitor’s serial number, rmware version, & current conguration.
Main Menu System Status
Function Input DVI-D
Scopes & Audio Meters Input Mode 1080p 60hz
Video Overscan Off
Audio Pixel Mapping Off
Marker Volume 16
System Contrast 0
Alarm Brightness 0
OSD Chroma 0
GPI Hue 0
Color Management Model BM210
System Status Version 1.0.00-1969
Support S/N M210A0000
Note that pressing an input button will temporarily call up a secondary system status summary window that will indicate
incoming signal resolution and frame rate, active color space selected on Color Management menu, gamma response
selected on Video Menu, & color matching function selected on Color Management Menu*.
*Color Matching Function toggle only works on OLED units, all other units currently use CIE 1931 CMF only.

© 2015 Flanders Scientic, Inc.
8
Return to Table of Contents
Function Menu
Main Menu Function
Function F1 Scopes & Audio Meters 1
Scopes & Audio Meters F2 Scopes & Audio Meters 2
Video F3 Scopes & Audio Meters 3
Audio F4 Marker
Marker F5 Measurement (10Bit)
System Function Display On
Alarm
OSD
GPI
Color Management
System Status
Support
The Function Menu allows you to assign user selectable functions to any of the 5 function buttons (F1, F2, F3, F4, & F5)
on the monitor keypad. Many monitor features listed as assignable options in the function menu are also selectable via the
embedded menus and are present simply to provide an option for faster, single button press access to the desired function.
Other features listed require a function key for activation, but may have associated customizable settings that can be found
in other menus.
Assigning Function Keys
To assign a function to a function key highlight one of the 5 Function lines and press ENTER. A list of assignable functions
will appear. Select the desired function with the UP and DOWN buttons and press ENTER to assign that function to the
corresponding function key. The Function Display option at the bottom of the Function Menu gives you the option to have
a temporary conrmation window appear on screen after a function key is pressed that will identify the function that was
turned on or off.
Scopes & Audio Meters 1, 2, 3
These functions toggle on/off a Scopes & Audio Meters prole. Three prole slots are available from the Scopes & Audio
Meters Menu and each prole can be set to a specic function key allowing you to instantly toggle between various types of
Scope and/or Audio Level Meter congurations. Please note that if you have set both Scopes Windows to the Off position in
the Scopes & Audio Meters menu nothing will appear on screen when you toggle this function (see Scopes & Audio Meters
Menu section of this manual for more details).
Cross Hatch
The Cross Hatch function toggles on/off the onscreen display of a graphical cross hatch overlay.
Marker 1, 2, 3
These functions activate the onscreen display of the preset Area, Safety, Custom Graticules, or Active Boundary Markers as
set in the Marker Proles. Marker Proles can be customized via the Marker Menu. By utilizing this function you can toggle
on/off your selected markers with a single function key (see Marker Menu section of this manual for more details).
Overscan
The Overscan function can work with 1:1 Pixel mapping mode on or off. With 1:1 Pixel to Pixel mapping mode turned off
the Overscanned image is scaled full screen. With 1:1 Pixel to Pixel mapping mode turned on the image remains unscaled,
but the area lying outside of the active scan area is blacked out. This area represents the same area not visible with Pixel
to Pixel mode off.
WARNING: Changing a function button
assignment does NOT automatically
turn an active function off. Make sure to
disable unwanted active functions before
changing function button assignments.
NOTE: Many features (Waveform,
Vector Scope, Audio Level
Meters, etc.) require a function
key in order to operate. Some
menus (such as the Scopes &
Audio Meters Menu) only set
your display preferences while a
corresponding function key must
be assigned to turn the feature
on and off. If you are having
trouble with a monitor feature
make sure you have assigned
the proper function key and any
corresponding menu settings.

© 2015 Flanders Scientic, Inc.
9
Return to Table of Contents
Function Menu
Details on Overscan Function
With the overscan function off all active lines of video can be displayed on screen. With overscan on a small percentage
of the outermost active video will not be displayed. Additionally, the monitor can scale the overscanned video full screen
or ‘blackout’ the outlying area while maintaining a pixel to pixel display of the video inside the active scan area. To toggle
between these variations of Overscan use the 1:1 Pixel to Pixel mapping function. With both Pixel to Pixel mapping and
Overscan selected the area outside of the active scan will simply be blacked out, but the active video will not be scaled
outside of the 1:1 pixel scan. With Pixel to Pixel mapping off and overscan on the active scan area will be scaled full screen.
To view all active lines in Pixel to Pixel mapping mode make sure to turn Overscan off.
Pixel to Pixel Off
Overscan Off
Pixel to Pixel On
Overscan On
Pixel to Pixel Off
Overscan On
Pixel to Pixel On
Overscan Off
Pixel to Pixel Off
Overscan Off
Pixel to Pixel On
Overscan On
Pixel to Pixel Off
Overscan On
Pixel to Pixel On
Overscan Off
Overscan Examples
(Images represent 720p source on BM230)
More Overscan Examples
(Images represent 1080i source on BM230)

© 2015 Flanders Scientic, Inc.
10
Return to Table of Contents
Function Menu
Sub Window
Largely deprecated for use on CFE2 equipped units. For side by side viewing on CFE2 units please use the dedicated PIP
function instead. The Sub Window function enables a Picture by Picture mode. After assigning the Sub Window function
to a function key the rst key press will result in a picture by picture display of your active input. Once sub window mode is
active you can press down on the H POS rotary knob to freeze the image on the right while the image on the left will continue
to show your live source. Once frozen you can also switch to any other input provided that the resolution of that input is the
same as the frozen source. To exit sub window simply press the assigned function key again.
Pixel Mapping
The Pixel Mapping function toggles between various available pixel mapping options. Options vary depending on the
incoming source, but may include the following:
1:1 Pixel Mapping: 1 pixel of incoming source is displayed as 1 pixel onscreen. If the incoming source resolution is less
than the total pixel count of the monitor your source will not ll the screen. This is often referred to as a postage stamp
representation of the source. If the incoming source resolution is greater than the total pixel count of the monitor then only
a portion of the incoming source will be shown onscreen, but the pixel position function (controlled by the H POS rotary
knob) may be used to view different sections of the 1:1 pixel representation. The monitor’s tally light will ash to remind
you that you are in 1:1 pixel mapping mode if any portion of the image is not shown on screen when in 1:1. This pixel
mapping mode can be combined with the SD Aspect Function (Anamorphic toggle) to activate a PAL SD FHA viewing
mode on the monitor. Once pixel mapping is active pressing down on the H POS knob will move the source to a different
onscreen position when pressed. Please note that if the incoming source is the same resolution as the panel the image
will not move. On monitors with lower than 1920x1080 resolution this feature can be used to view any section of a 1080
source in a native 1:1, unscaled format. Similarly, on all native 1920x1080 or 1920x1200 resolution monitors this mode
will allow you to view any portion of an incoming 2K source in an unscaled 1:1 onscreen representation.
2:1 Pixel Mapping (SD sources only): Every individual pixel of the incoming source is represented by four pixels onscreen.
This scaling algorithm is simple and allows for a largely artifact free double size version of the 1:1 Pixel Mapping Mode for
SD sources. While 2:1 scaling will still not ll the entire screen on a 1920x1080 resolution monitor, it does use a majority
of the vertical screen height and provides an excellent quality large scale representation of the SD source.
Full Screen Mapping: The full screen mode will scale the incoming source to ll as much of the screen as
possible while preserving the incoming source’s native aspect ratio. If the incoming source and panel share
the same resolution then there will be no difference between 1:1 pixel mapping and full screen pixel mapping.
Please note that the Overscan function will be represented differently based on the pixel mapping selection that you select.
Pixel Position
This feature is a part of the Pixel Mapping function and provides a toggle for positioning a 1:1 Pixel to Pixel mapped
representation of an incoming source on different areas of the screen. Once pixel mapping is active the H POS knob
will move the source to a different onscreen position when pressed. Please note that if the incoming source is the same
resolution as the LCD panel the image will not move. The pixel position feature does not work unless the 1:1 Pixel to Pixel
mapping mode function is turned On. On 7”, 9”, and 17” monitors this feature can be used with the Pixel to Pixel Mode
to view any section of a 1080 source in a native 1:1, unscaled format. Similarly, on all native 1920x1080 or 1920x1200
resolution monitors this mode will allow you to view any portion of an incoming 2K source in an unscaled 1:1 onscreen
representation.
H/V Delay Mode
This mode activates the Horizontal and Vertical Delay function to highlight the horizontal and vertical blanking portions of the
incoming signal. This can be used in conjunction with the Video Data feature for specic analysis of Horizontal and Vertical
Blanking data.
Mono Mode
This mode activates the Monochrome function. Press once to turn on and again to turn off.

© 2015 Flanders Scientic, Inc.
11
Return to Table of Contents
Function Menu
SD Aspect Ratio
Toggles between 4:3 and Anamorphic display of Standard Denition source. This function should be set to match the SD
source being viewed. The default setting is 4:3. If used in conjunction with 1:1 pixel mapping this function can also activate
a PAL SD FHA viewing mode.
Full Screen
This function simply stretches any incoming source to ll the entire screen. Unlike the Zoom feature this full screen stretch
does not preserve aspect ratio, but it does keep all of the active video signal present. Though the full screen mode has
many potential uses it was designed primarily for use with rasterizers that generate a 16:10 or 16:9 aspect 1024x768 output.
Enabling Full Screen mode allows the monitor to stretch the image as intended by the rasterizer.
Pixel Zoom
The Pixel Zoom function will generate a positionable and resizable rectangle on screen. The rectangle may be moved left or
right using the H POS rotary knob and up or down using the V POS rotary knob. The Ref POS rotary knob may be used to
change the size of the onscreen rectangle. Using these three rotary knobs you can select any area on screen and then press
down on the F Stop rotary knob to zoom to the selected area. This pixel zoom feature is designed to work with any HD signal
formats. A ashing tally light will be activated on your monitor whenever you are in a zoomed mode as a reminder/warning
that the entire incoming signal is not being shown on the monitor. To exit the zoomed mode simply press down on the F
Stop rotary knob once more. To exit the Pixel Zoom feature entirely simply press the function button assigned to this feature
once more. The Pixel Zoom function allows for an essentially artifact free, high quality zoom on any portion of an HD signal.
LUM Coloring
The F Stop Rotary knob will adjust the upper limit of the upper color coded region. These color coded ranges are retained in
memory so you can exit and reenter LUM Coloring Mode without having to reset your desired threshold levels.
Blue/Red/Green Only
This function activates the monitor’s Blue Only, Red Only, and Green Only modes. The respective channels can be shown
as just that color (Red, Green, Blue) or as monochrome.
LUM Coloring with Custom Range LUM Coloring with All Legal Levels Shown in Greyscale
Underexposed Areas in Blue
Overexposed Areas in Red
LUM Coloring in Default Mode
Overexposed Areas in White
Underexposed Areas in Black
LUM Coloring with Custom Range
This function generates an articial luminance
map of the incoming source that can be
particularly useful in identifying overexposed
areas in any given shot. An onscreen scale
helps indicate what articial color corresponds
to what luminance level. The scale will follow
the selected Waveform Scale set in the Scopes
& VU Meters Prole 1: you can choose from
IRE, Digital Levels, or Voltage. In its default
conguration the LUM Coloring feature will
highlight all levels above 100IRE as white and
all levels below 0 IRE as black. In default mode
levels between 0 and 100 IRE will be color
coded. However, you can change the range of
these color coded regions to any preferred
setting by using the monitor’s rotary knobs.
The H POS rotary knob will adjust the lower
limit of the lower color coded region. The
V POS rotary knob will adjust the upper limit
of the lower color coded region. The Ref
POS rotary knob will adjust the lower
limit of the upper color coded region.

© 2015 Flanders Scientic, Inc.
12
Return to Table of Contents
Function Menu
Measurement (10bit & 8bit)
This function allows you to get precise real time YRGB measurements of any point or area within your incoming signal.
With the Measurement function on you can use the H POS and V POS rotary knobs to position your crosshair over the point
within your source that you would like to measure. To reset the vertical or horizontal position of your crosshair back to center
simply press down on the corresponding rotary knob. You may also use the Ref POS rotary knob to select the size of the
sampling area for the measurement data (from a single pixel to a much larger area where the values will be an average of
all pixels within your dened sample area). As you move the crosshair your Measurement data will update in real time. The
Measurement function is available in a 10 bit mode or 8 bit mode and will provide you with the following data in real time:
• Line and Sample (Identies position of your crosshair)
• Y (Luminance as an absolute value between 0-255 for 8 bit and 0-1023 for 10 bit)
• Y% (Luminance level expressed as percentage)
• R% (Red level expressed as percentage)
• G% (Green level expressed as percentage)
• B% (Blue level expressed as percentage)
• R (Red level as an absolute value between 0-255 for 8 bit and 0-1023 for 10 bit)
• G (Green level as an absolute value between 0-255 for 8 bit and 0-1023 for 10 bit)
• B (Blue level as an absolute value between 0-255 for 8 bit and 0-1023 for 10 bit)
You can also press the Ref POS rotary knob to set a reference position onscreen. Once your reference position is set
it will be indicated on screen by a separate crosshair and you will be able to move the active crosshair to obtain a real
time readout of your current and reference positions as well as a separate readout of the precise difference between
current and reference locations. Please note that your reference position is both a spatial and temporal reference meaning
that the values indicated on screen for the reference are for that point on screen at the moment you set the reference.
Pressing the F Stop rotary knob button allows you to set your current crosshair position as an F-Stop Reference
and view differences between this current position and your reference position as an F-Stop value. The F-Stop
reference feature is independent of the Ref POS feature. The F-Stop reference value will always be based on
the levels of your current active crosshair position at the precise moment when the F-Stop knob is pressed.
The crosshair color will follow the color selected for markers from the Marker Menu. To change the color of the Measurement
function’s crosshair change the Marker color.
Measure Line Sample Y1024 R1024 G1024 B1024 Y% R% G% B% F/stop
Current 293 944 249 246 251 217 21.1 20.8 21.3 17.5 -0.0
Ref_Pos 316 994 240 240 241 219 20.1 20.1 20.2 17.7 -0.1
Diff -24 -51 9610 -2 1.0 0.7 1.1 -0.2 0.1

© 2015 Flanders Scientic, Inc.
13
Return to Table of Contents
Function Menu
Video Data
The Video Data function is a sophisticated signal data analyzer providing realtime decimal or hexadecimal readout of
video data at the pixel level. Data is represented in a 18 x 10 pixel grid where each pixel’s corresponding color is used as
the background color for that position within the grid. A small green rectangle on screen shows what area of the image is
currenlty being analyzed. The grid position as well as the data readout can be manipulated with the rotary knobs as outlined
below:
•
H POS rotary knob moves the selected analysis point horizontally on screen. Pressing down on this knob returns you
to the horizontal center of the screen.
•
V POS rotary knob moves the selected analysis point veritically on screen. Pressing down on this knob returns you to
the vertical center of the screen.
•
Pressing down on the REF POS rotary knob toggles you between YCbCr and RGB data readouts.
•
Turing the REF POS rotary knob toggles between decimal and hexadecimal data readouts.
•
Turn the F STOP rotary knob to toggle between 8 bit and 10 bit data readouts.
•
Pressing down on the F STOP rotary knob will cause the green position rectangle to ash white on screen to make it
easier to locate.
The Video Data function can also be used in conjunction wtih the H/V Delay function. When you enable H/V Delay with
Video Data active you will see a Full Raster position indication appear at the bottom of the Video Data window. This provides
your curosr position in the order Line then Sample relative to the full raster instead of just the active picture data. This can
be useful for nding and analyzing specic Horizontal and Vertical blanking data. If analyzing an interlaced source putting
the monitor in Noise Reduction processing mode will make the data easier to read.

© 2015 Flanders Scientic, Inc.
14
Return to Table of Contents
Function Menu
CIE Measurement
This function allows you to get precise real time chromaticty measurements of any point or area within your
incoming signal as well as a real time plot of the measured position on a CIE color space diagram. With the CIE
Measurement function on you can use the H POS and V POS rotary knobs to position your crosshair over the point
within your source that you would like to measure. To reset the vertical or horizontal position of your crosshair back
to center simply press down on the corresponding rotary knob. You may also use the Ref POS rotary knob to select
the size of the sampling area for the measurement data (from a single pixel to a much larger area where the values
will be an average of all pixels within your dened sample area). As you move the crosshair your Measurement data
and plot will update in real time. The CIE Measurement function will provide you with the following data in real time:
• Line and Sample (Identies position of your crosshair)
• R’ (Red signal level percentage normalized to 10 bit data range)
• G’ (Green signal level percentage normalized to 10 bit data range)
• B’ (Blue signal level percentage normalized to 10 bit data range)
• Y% (Luminance level as percentage)
• x (CIE 1931 x chromaticty coordinate)
• y (CIE 1931 y chromaticty coordinate)
• u’ (CIE 1976 u’ chromaticty coordinate)
• v’ (CIE1976 v’ chromaticty coordinate)
• dE2000 (difference between current & reference expressed as dE2000 value)
You can press the Ref POS rotary knob to dene a reference position on screen. Once your reference position is set
it will be indicated on screen by a separate crosshair and you will be able to move the active crosshair to obtain a real
time readout of your current and reference positions as well as a separate readout of the precise difference between
current and reference locations. Please note that your reference position is both a spatial and temporal reference meaning
that the values indicated on screen for the reference are for that point on screen at the moment you set the reference.
Pressing the F Stop rotary knob button allows you to toggle the CIE color space diagram between CIE 1931 and CIE 1976
views. Your chromaticty plots are calculated using signal input data relative to your active Color Space selection on the Color
Management menu. Since your reference color gamut for chromaticty calculation follows this selection it allows you to have
Rec709, DCIP3, EBU, or SMPTE C as your reference color gamut. Please note that if you have the Color Space selection set
to Wide Gamut or a custom USER position the reference gamut used for the CIE Measurement feature will default to Rec709.
The crosshair color will follow the color selected for markers from the Marker Menu. To change the color of the CIE
Measurement function’s crosshair change the Marker color.
CIE Line Sample R’ G’ B’ Y% x y u’ v’ dE2000
Current 542 960 971 0 118.93 0.6400 0.3300 0.4507 0.5229
Ref_Pos 541 961 1023 1023 1023 100 0.3127 0.3290 0.1978 0.4683
Diff 1 -1 -52 -1023 -1022 -81.7 0.3273 0.0010 0.2529 0.0546 47.678

© 2015 Flanders Scientic, Inc.
15
Return to Table of Contents
Function Menu
CIE Scope
This function maps out full frame signal data on a CIE diagram.
Signal levels are mapped out relative to your active color space
selection on the Color Management menu. Your active color
space selection is represented by a black trinagle on the CIE
diagram.
If you have one of the custom User Color Space selections active
then this reference gamut will default to Rec709. In addition
to the primary color gamut indication (black triangle) you can
press down on the V POS rotary knob to generate a secondary
color gamut overlay as a grey triangle. This secondary color
gamut overlay is purely for comparative reference and does not
inuence how signal levles are mapped relative to the primary
color gamut selection.
The CIE diagram may be toggled between CIE 1931 and
CIE 1976 views by pressing down on the H POS rotary knob.
Please note that this is a very processor power intensive feature and video quality, specically video sharpness, will
be degraded while active. For this reason we suggest using the CIE Scope feature as needed for specic color gamut
analysis, but we do not reccomend leaving the feature enabled at all times.
4K Display (CFE2 Units Only)
This feature is currently in limited beta testing only. Further support & documentation may be offered in conjunction with
future rmware releases.
3D Disparity
This feature only works when SDI 1 and SDI 2 are the same frame rate / resolution and are genlocked. When active a
disparity view will be shown on screen highlighting the difference between SDI 1 and SDI 2.

© 2015 Flanders Scientic, Inc.
16
Return to Table of Contents
Function Menu
Focus Assist
The focus assist feature is comprised of two main parts: a numerical focus meter and a graphical focus highlight.
The numerical focus meter is shown on screen as your current focus value over your reference focus value (i.e.
560/300). When the focus assist feature is activated the rotary knob labeled Ref POS allows you to adjust the
reference focus value. The reference focus value represents the in-focus threshold for the focus highlight portion
of the focus assist feature. Adjusting the focus reference value higher means that the threshold at which the focus
highlight begins to trace in-focus items with a red boundary will be higher. In other words a greater degree of focus
will need to be achieved before the focus highlight feature is visible on screen as a red trace around in-focus objects.
Variable Wipe
When monitoring a Level B 3Gbps SDI signal (monitor must have 3Gbps SDI Input) comprised of two multiplexed 1.5Gbps
HD-SDI signals the monitor will allow you to view these signals in a vertical or horizontal split screen mode. By activating the
Level B Variable Split function while in split screen mode the positioning of the split can be adjusted using the H POS rotary
knob. To quickly reset the split screen positioning to the default center position simply press down on the H POS rotary knob
while the Variable Wipe function is active. Once your desired split screen wipe position is set you can turn the Variable Wipe
function off to remove the guide line between the two signals. This feature can also be used with the Horizontal and Vertical
Split PIP modes using two distinct signals fed to SDI and SDI 2 on the monitor.
Still Frame
This function allows you to freeze a video source at anytime. To unfreeze simply press the function key assigned to Still
Frame a second time.
Zoom
This function zooms in on the incoming source until the entire screen is lled. This is strictly a zooming function and does
not alter the native aspect ratio of the source to ll the screen. When viewing a 4:3 source in Zoom mode on a 16:9 display
the aspect ratio of the visible video will remain 4:3 though the entire 16:9 screen will be lled. Essentially the Zoom mode
results in viewing a 16:9 section of the 4:3 source and is most useful when viewing a letterboxed SD source on a widescreen
display so that the letterboxing is not shown and only the video within the letterboxing is present.
DSLR Zoom
This function is designed to be used with many popular DSLR cameras that have preview/record monitoring output in 1080
& 480 resolutions. When DSLR Zoom is active the 16:9 area that will be recorded is scaled to ll the screen. On DSLR
cameras that switch from 1080 to 480 while recording the DSLR Zoom can be left on and the same correct aspect zoom will
be maintained regardless of whether the DSLR is in preview or recording mode. While DSLR Zoom is active the markers
may also be turned on and will be correct relative to the 16:9 video that will be captured to the camera’s memory card. Please
note it may be necessary to toggle the viewing mode preference (Info button on many DSLRs) to ll the screen correctly.
In Focus Shot with Default Focus
Reference Value
Less Focused Shot with Default
Focus Reference Value
Example of Shot with Focus
Reference Value Turned Up

© 2015 Flanders Scientic, Inc.
17
Return to Table of Contents
Function Menu
DSLR Zoom (continued)
Safety Broadcast
Safety Broadcast is a special monitoring mode designed for Control Room and QC station environments. With Safety
Broadcast mode activated you can have simultaneous display of two audio level meters, Enhanced Source ID display (large
overlay, remotely or manually set), Enhanced Alarm Window Display (large window, red background), and
DSLR in 1080i Preview with DSLR Zoom feature Off DSLR in 1080i Preview with DSLR Zoom Feature On
DSLR in 480p Record Mode with DSLR Zoom feature off DSLR in 480p Record Mode with DSLR Zoom feature On
enhanced timecode display (large timecode overlay
window). Please note that as with the standard Alarm
Monitoring feature the monitor may respond slowly
to user toggles/inputs if a constant alarm condition is
occurring. Toggles for UMD Display, Color, and
Position are found in the Alarm Menu. Vertical or
Horizontal Safety Broadcast Audio Meter selection
is also found in the Alarm Menu.

© 2015 Flanders Scientic, Inc.
18
Return to Table of Contents
Function Menu
AFD (Active Format Description)
Anamorphic De-Squeeze
This feature gives you the ability to de-squeeze HD signals coming from cameras utilizing anamorphic lenses that may not
have a built in de-squeeze feature of their own. This can be particularly useful in applications outside of post production,
especially onset monitoring, where de-squeezing such signals in real-time may otherwise not be possible. The de-squeeze
modes available are 1.3, 2.0, and 2.0mag. This feature is in addition to, and not a substitute for, the SD Aspect Ratio function.
To use this feature set Anamorphic DeSqueeze to a function button, which will allow you to toggle the de-squeeze on and
off. To set the desqueeze ratio/magnication go to the Video Menu and select your desired Anamorphic De-Squeeze mode.
Anamorphic De-Squeeze Modes
Activating this function will enable an Active Format Description
reader on the monitor that will provide both a text readout of AFD
data and display corresponding markers onscreen indicating
the portions of the image described by the AFD code. If no AFD
data is present while this feature is active the monitor will show
AFD: NONE in its AFD readout window.
1.3x Anamorphic Original 1.3x Anamorphic De-Squeeze
2.0x Anamorphic Original 2.0x Anamorphic De-Squeeze
2.0x Anamorphic Original 2.0x mag Anamorphic De-Squeeze
AFD: 0x0d
code frame 16:9
active image 4:3
image position horizontal center
with alternative 14:9 center

© 2015 Flanders Scientic, Inc.
19
Return to Table of Contents
Function Menu
Invert Screen (LM-0950W Only)
Allows the image to be ipped onscreen in real-time. This function only works on the LM-0950W.
CX Scale
This scaling mode was designed specically to allow the scaled down and top centered ’gate check’ output from Codex™
ARRIRAW Recorders to be scaled full screen. Once assigned to a function key you can quickly enter or exit this custom
scaling mode with a single button press. Please note that some functions, such as markers, will not work while this mode is
active. However, other useful functions such as Waveform and Vector Scope will continue to operate normally.
C-Log, S-Log, S-Log2, S-Log 3 and BMD-Log Modes (Also selectable via Video Menu)
These modes allow for easier on-set monitoring of uncorrected of C-Log, S-Log, S-Log2, or BMD Cinema Camera Film
Mode Output by roughly normalizing the footage. For all Log modes there is both a Standard and Full selection. The
Standard selection is suitable for most applications, but does clip highlights to allow for a brighter overall image. The Full
mode is best used for scenes with extremely wide latitude or scenes that are just very bright overall. Full mode preserves
the entire native latitude of the signal (nothing is clipped), but this can result in a rather dark image in many applications.
We provide both for this reason and you can quickly toggle between them as needed for different applications by assigning
these modes to function keys. These modes should only be used to offer on set viewers a rough normilization of the footage
to give them an idea of what the content might look like as a starting point in post production. In other words, it provides you
with a helpful tool to show on set viewers something that does not look ‘at’. These modes are not a replacement for full 3D
LUT transforms and not a substitution for proper color correction in post production applications. For more advanced Log
mode normalization use a custom 3D DIT LUT.
Rec. Status Tally
This function is designed for use with cameras that output Start/Stop Record ags in the ancillary data of their serial digital
output. To activate this function set Rec. Status Tally to a function button and press that function button once. While active
the monitor’s red tally light will turn on when the Start Record SDI ag is detected and will turn the red tally light off when the
Stop Record SDI ag is detected.
On-Screen Tally
When activated this function will generate an onscreen box that mirrors the status of the physical tally on the monitor’s bezel.
This can be particularly useful in applications where the physical tally may be obscured.
Picture In Picture (PIP) - Live Side by Side and Picture In Picture Viewing
On BM and CM series monitors (excluding CM-170W), the Picture In Picture function will allow you to toggle Picture In
Picture. Corresponding controls can be found in the System Menu to change your PIP Secondary Input and PIP Mode,
allowing you to select Picture In Picture, Picture And Picture (Side-By-Side Monitoring), Picture On Picture, Vertical Split
Screen, or Horizontal Split Screen. You can use the Variable Wipe function in conjuction with the Vertical and Horizontal Split
modes to set a custom split position other than the default of center screen.
Max Sharpness
In addition to the Sharnpess Level Setting found on the Video Menu there is an assignable function called Max Sharpness
that will allow you to use a function button to toggle in/out of maxium sharpness mode quickly.
Dual Link
CM & BM sereies units equipped with FSI’s second generation Color Fidelity Engine (CFE2) can support Dual Link SDI
(2 x 1.5Gpbs SDI) in addition to single link 3Gbps SDI for advanced signal format support. 3Gbps SDI is the preferred
connectivity method if available, but if single link 3Gbps SDI output from your source is not available you can use the Dual
Link funciton to activate Dual Link SDI support. To activate this capability rst select SDI 1 as your input. Then set Dual Link
to a function button. Then press that designated function button to to turn on Dual Link mode. Once active you may need to
set your SDI format manually if no payload ID is present in the signal. To do this go to the SDI format section of the Video
Menu and select the appropriate format.

© 2015 Flanders Scientic, Inc.
20
Return to Table of Contents
Marker Menu
Main Menu Marker
Function Marker Select Prole 1
Scopes & Audio Meters Area Marker 4:3
Video Safety Marker 90%
Audio Marker BG. Normal
Marker Center Marker On
System Marker Color White
Alarm Safety in Area On
OSD Active Boundary Off
GPI Graticules Off
Color Management
System Status
Support
Marker Select
Toggles between three Marker Proles. Each prole stores all marker preferences and can be recalled from the function
menu by assigning a function button to a specic marker prole.
Area Marker
Use the Area Marker function to select what type of marker is displayed when the marker function is active. The marker
selections available from this option include most commonly used markers and more complex user designed custom
markers. Area Markers and Safety Markers may be displayed simultaneously provided that the Marker Background function
(described below) is set to Normal.
Safety Marker
Use the Safety Marker function to toggle the size, in percentage, of the safety marker displayed. This option can be used by
itself or in conjunction with the Area Marker function provided that the Marker Background function (described below) is set
to Normal. The Safety Marker may be displayed relative to the incoming source or the Area Marker by toggling the Safety
in Area option on the Marker Menu.
Marker BG.
The Marker Background setting can be used to toggle how the area that lies outside of the Area Marker or Safety Marker
boundaries is represented. You can select from Normal, Transparent, or Solid.
Center Marker
Toggles whether the center marker (crosshair) is displayed when the marker is activated.
Marker Color
This setting allows you to select the color of the marker being used. This can be especially useful when one color dominates
the screen and an easily visible high contrast marker is desired.
Active Boundary
When turned on, the Active Boundary marker will highlight the edges of any active video area not directly bordering the
monitor’s bezel. This is useful for detecting missing lines in the active video area.
Safety in Area
Toggles whether Safety Marker is shown relative to incoming source or relative to Area Marker (i.e. 4:3)
Graticules & Graticules Info
Toggles Custom Marker Feature On/Off. Use rotary knobs to adjust line positioning. Set Graticules Info to Off to clear line
position and span size readouts.
NOTE: The Marker Menu only sets
your marker preferences. To toggle the
onscreen display of your congured
marker assign the Marker function to one
of the function keys. See the Function
Menu section of this manual for more
details.
This manual suits for next models
12
Table of contents
Other FSI Monitor manuals