FTE Maximal MSR A 05 SA Series User manual

MSR A 05X SA
USER’S MANUAL
Rev 1.1


User’s manual · MSR A-05X SA
- 1 - MSR A-05X SA Version_en_1.1 FTE Maximal
Chapter1. Installation.
1.1. Safety Rules
1.- Never place the equipment next to hot sources.
2.- Never undergo the equipment to temperatures that exceed the level of operation of the device.
3.- Do not expose the equipment to dripping or splashing.
4.- Do not place objects filled with liquids on the equipment.
5.- Respect ventilation slots of this equipment. Avoid covering them with any object.
6.- Keep clean and without obstacles a minimum radius of 40 cm around this equipment.
7.- Avoid locations with possibilities of spilling liquids on the inside of the device, and with important changes of
temperature.
8.- Use the equipment only in moderate climates (not in tropical climates).
9.- Never open the equipment yourself due to electric risk. In case of problems, go always to qualified technicians.
10.- Never, under no circumstances, open the equipment connected to the electrical net.
11.- During the handling it is better to disconnect the equipment of the electrical net.
12.- Respect the electricity security rules during the assembling. Use materials that obey the current law.
13.- The connecting plug must be accessible in a fast and simple way to have a fast disconnection.
14.- Never touch the plug with wet hands. Also, disconnect always the device before handling the connections.
15.- Never put any heavy object over the device, as it could get damaged.
16.- If the equipment is going to remain some time without use, it is recommendable to disconnect it from the electrical
net.
17.- The repairmen and the maintenance of the equipment must be done by TV and radio specialist technicians.
1.2. Box Content
User’s manual
Tooling for F connector
Depending on the model purchased, the box will contain one of the following multiswitches:
MSR A 0508 SA
MSR A 0512 SA
MSR A 0516 SA
MSR A 0524 SA
MSR A 0532 SA

User’s manual · MSR A-05X SA
- 2 - MSR A-05X SA Version_en_1.1 FTE Maximal
1.3. Description and connections
Description
This family of multiswitches is used to make installations with a certain number of connected users and it is compatible
with digital and analogical signals.
The models available allow us to distribute 4 polarities of a satellite for 8, 12, 16, 24 or 32 receivers making an
independent commutation in order to receive in each receiver the 4 polarities of satellite. The inputs are independent for
each polarity of the satellite.
All the models of this family are provided with an inner amplification in order to avoid the derivation loses and the
distribution of the terrestrial bans is active.
Switching criterion
Polarity / Band
13 V / 0kHz
Vertical / low
18 V / 0kHz
Horizontal / low
13 V / 22kHz
Vertical / high
18 V / 22kHz
H
orizontal / high
Connections
MSR A 0508 SA
1-8 REC1-REC8 47-2150 MHz: Outputs (SAT + TERR) *
9 H HIGH-BAND 950 – 2150 MHz 18V / 22 kHz : Satellite signal input
10 V HIGH-BAND 950 – 2150 MHz 13V / 22 kHz : Satellite signal input
11 TERR 47 – 862 MHz : Terrestrial signal input
12 H LOW-BAND 950 – 2150 MHz 18V / 0 kHz : Satellite signal input
13 V LOW-BAND 950 – 2150 MHz 13V / 0 kHz : Satellite signal input
(*) Note: In order to identify the outputs in the others models it is indicated with arrow in the direction of the connector and the number of the respective
output.
14
9
1
2
3 4
5
6
7
8
9
10
11
12
13

User’s manual · MSR A-05X SA
- 3 - MSR A-05X SA Version_en_1.1 FTE Maximal
1.4. Accesories and example of installation
Accesories
P
arab
olic antenna
LNC Universal Quattro
Terrestrial antenna
Example ofinstallation
Example of an installation for 8 users with 4 satellite polarities, distributed by a
MSR A 0508 SA multiswitch. It allows the full reception (analogical and digital)
of a satellite. The multiswitch does not introduce losses in the terrestrial output
therefore it does not need previous amplification. In this case in order to acces to
the different satellite polarities, the receiver must be provided with DiSEqC 1.0
standard commutation or upper.

User’s manual · MSR A-05X SA
- 4 - MSR A-05X SA Version_en_1.1 FTE Maximal
Chapter2. Technical features
Reference MSR A 0508 SAMSR A 0512 SAMSR A 0516 SAMSR A 0524 SA
MSR A 0532 SA
Code 0930180 0930182 0930184 0930186 0930188
Nº ofinputss 5 5 5 5 5
Subscriber outputs 8 12 16 24 32
Connectors F female F female F female F female F female
Frequency range
(MHz)
SAT: 950-2150
TER: 47-862
SAT: 950-2150
TER: 47-862
SAT: 950-2150
TER: 47-862
SAT: 950-2150
TER: 47-862
SAT: 950-2150
TER: 47-862
Satellite gain 5 ±1.5 dB 5 ±1.5 dB 5 ±1.5 dB 2 ±1.5 dB 2±1.5 dB
Terrestrial gain 7 ±1.5 dB 7 ±1.5 dB 7 ±1.5 dB 7 ±1.5 dB 7±1.5 dB
Isolation Ter - Sat 30 dB 30 dB 30 dB 30 dB 30 dB
Isolation Sat-Ter 28 dB 28 dB 28 dB 28 dB 28 dB
I
solation cross
polarisation H/V 25 dB 25 dB 25 dB 25 dB 25 dB
Isolation
Out-Out TER 28 dB 28 dB 28 dB 28 dB 28 dB
IsoIation
Out-Out SAT 35 dB 35 dB 35 dB 35 dB 35 dB
Return loss SAT
input 11 dB 11 dB 11 dB 10 dB 10 dB
Return loss SAT
output 9 dB 9 dB 9 dB 8 dB 8 dB
Return loss TER
input 11 dB 11 dB 11 dB 10 dB 10 dB
Return loss TER
output 9 dB 9 dB 9 dB 8 dB 8 dB
Output level SAT
(IMD3 - 35dB) 100 dBµV 100 dBµV 100 dBµV 100 dBµV 100 dBµV
Output level TER
(IMD3 - 60dB) 85 dBµV 85 dBµV 85 dBµV 85 dBµV 85 dBµV
Impedance
input/output 75 75 75 75 75
Switching (VDC) 13V/18V / 13V-22 kHz / 18V-22 kHz
22KHz generator No
Max LNB Current 13Vdc 400mA / 18Vdc 1000mA
Mains 230Vac ±15% 50-60Hz 3W
Temperature range -10ºC/50ºC
Dimensions 248x129x64 mm 288x129x64 mm 328x129x64 mm 408x129x64 mm 488x129x64 mm
Weight (g) 740 840 930 1120 1300
Chapter3. Conformity Declaration
CONFORMITY DECLARATION
“WE, FTE MAXIMAL, DECLARE THAT THE PRODUCTS
MSR A 0508 SA, MSR A 0512 SA, MSR A 0516 SA,
MSR A 0524 SA AND MSR A 0532 SA
ARE IN CONFORMITY WITH FOLLOWING DIRECTIVES
RED DIRECTIVE 2014/53/EU
RoHS2 2011/65/EU”
If you wish a copy of the conformity declaration, please contact to the company


BCN DISTRIBUCIONES S.A.U.
Agustí Pi i Sunyer, 15
08192 Sant Quirze del Vallès
(Barcelona) España
Tel. +34 93 729 27 00
Fax. +34 93 729 30 73
www.ftemaximal.com
This manual suits for next models
10
Table of contents
Other FTE Maximal Switch manuals