5. Set blade alarm function by one of the following method
(1) Set [Blade Alarm Detection] to [Image Analysis]
(2) Set [Blade Rotation Link To Alarm] to [Auto Without Confirmation] or [Manual With
Confirmation]
At that time, it is automatically changed [Blade Alarm Detection] to [Image Analysis].
Auto Without Confirmation
When the splicer detect the cleaver blade worn, rotate
the cleaver blade automatically without any confirmation.
When the splicer detect the cleaver blade worn, show the
message whether change the blade position.
6. [Number of Cleaving Errors] and [Number of Cleaves] appear.
You can avail auto blade rotating function.
In this case, the splicer rotates the blade if the splicer detects error 3 times in last 10 times
gap set.
+++Issued by Engineering Division of Fusion Splicer Department+++