Fulcrum Torbal DRX-4 User manual

Instruction Manual Model:

Instruction Manual Model
Fulcrum Inc.
23 Carol Street.
Clifton, NJ 07014
(973) 473-6900
(973) 777-8302
http://www.fulcruminc.net


TABLE OF CONTENTS
0
0
0
0
0
0
0
0
0
1
1. Specifications......................................................................
2. Parts Description................................................................ 2
3. Keys and display indicators................................................... 3
4. Commands........................................................................ 4
5. Getting Started.................................................................. 5
6. Weighing........................................................................... 7
7. Zeroing the Scale................................................................ 8
8. Taring.............................................................................. 9
9. Clearing the Tare............................................................... 11
10. Printing............................................................................ 12
11. Calibration........................................................................ 14
12. Sealing the DRX-4............................................................. 17
Paper Seal..............................................................17
Wire Seal............................................................... 18
13. Setting the Time and Date .................................................. 19
14. Common Errors and Troubleshooting.....................................23
13.
14.


I n s t r u c t i o n M a n u a l M o d e l D R X - 4
Specifications:
1
C H A P T E R 1

Parts Description:
2
Front View Rear View
Pan Base Pan AC Adaptor Flush Sealing
Screw
Adjustable Legs
Wire Seal Screws AC Adaptor socket
RS232 Serial Port
Calibration Switch Level Indicator
I n s t r u c t i o n M a n u a l M o d e l D R X - 4
C H A P T E R 2

Keys and display indicators
3
Center of zero NET result indicator
Stabilization indicator Used Capacity Indicator
** In order for the scale to enter and remain in the Standby Mode, the power
supply must be plugged into the scale.
NOTE:
Tare button - used to tare the weighing pan and enter or accept
commands.
Function button - used to enable and disable the printing capability.
Power On/Off button.- when turned “Off” the scale enters Standby
Mode. **
Scale stabilization indicator - signals the weighing result has
stabilized and an accurate reading may be taken.
AZSM - indicates the Auto Zeroing Setting Mechanism (AZSM) is
active. AZSM maintains a center of zero condition within +/- .6d or
6mg
Dotted line on the display indicates the “T” or “0” buttons have been
pressed and the scale is taring or re-zeroing.
Weighing unit (grams).
Print button, used to print or send data to a PC.
Zero button, used to re-zero the scale.
I n s t r u c t i o n M a n u a l M o d e l D R X - 4
C H A P T E R 3

Commands
4
* These commands apply only to the Calibration Mode.
NOTE:
PRINT
CAL
TARING
LOAD 100g
C
CAL FIN
When pressing the “P” button, “PRINT” indicates data is
printing via the serial port.
Indicates the rear calibration switch has been toggled to the
ON position and the scale is in the Calibration Mode.*
Indicates the scale is taring for the calibration procedure to
begin.*
Indicates to load the calibration weight of 100 grams on the
pan to begin calibration.*
The scale is calibrating.*
Calibration procedure is finished.*
I n s t r u c t i o n M a n u a l M o d e l D R X - 4
C H A P T E R 4

Getting Started
5
1. Carefully remove the scale and all of its components from the packaging
and place it on a stable base where the scale will not be affected by any
mechanical vibrations or air movements.
2. After removing the pan base and the pan from its packaging, carefully
install the pan base onto the scale by placing it on the pan support located
in the middle of the scale. Once the pan base has been installed, carefully
place the pan on the base as shown below.
I n s t r u c t i o n M a n u a l M o d e l D R X - 4
C H A P T E R 5

6
3. Once the pan has been installed, level the scale by adjusting the rear feet
until the level indicator shows the “air bubble” is in the center position of the
sight glass. The level indicator is located in the rear left side of the scale.
4. After leveling the scale, plug in the AC adaptor to the AC adaptor socket
located in the rear of the scale.
Level Indicator Sight Glass:
Air Bubble
Incorrect Correct
I n s t r u c t i o n M a n u a l M o d e l D R X - 4

7
5. When the AC adaptor is plugged into the wall outlet, the scale will turn
“ON” automatically, go through its initiation process, and enter Weighing
Mode.
To put the scale into Standby Mode, leave the AC adaptor plugged into both
the scale and the wall outlet and press the Power “OFF” button ( ). The
“OFF” indicator will light up in the upper left corner of the display signaling
the scale is in Standby Mode, i.e.:
Weighing
Display in Standby
Mode
Display in Weighing
Mode
To begin weighing, press the power button ( ) to turn the scale ON. The
scale will go through its initialization procedure and automatically enter
Weighing Mode. The scale is ready to begin weighing as soon as the
stabilization ( ) and center of zero ( ) indicators appear on the display,
i.e.:
1.
I n s t r u c t i o n M a n u a l M o d e l D R X - 4
C H A P T E R 6

8
2. When weighing, always place the mass in the middle of the pan. The
weighed result may be taken when the stabilization indicator appears on
the display, i.e.:
Zeroing the scale
Display indicating an
accurate 4g result
1. The DRX-4 is armed with AZSM, the “Auto Zero Setting Mechanism.”
AZSM automatically maintains a “center of zero” condition within +/- .6d
or 6mg
2. The scale may be re-zeroed manually to obtain a new “center of zero.” To
re-zero the scale manually with a weight that is out of the AZSM range,
make sure the weight and the stabilization indicator are shown on the
display, i.e.:
3. Re-zero the scale by pressing the zero button.
4. The display will show a dotted line, which indicates the scale has begun
the re-zeroing process, i.e.:
WARNING: Do not touch or move the scale during the
re-zeroing process.
Display in the
re-zeroing process
I n s t r u c t i o n M a n u a l M o d e l D R X - 4
C H A P T E R 7

9
5. When finished re-zeroing, the scale will return to Weighing Mode and the
display will indicate 0. A new center of zero has been set, and the scale is
ready for weighing.
Taring
Display in the
Weighing Mode
after it has been
re-zeroed
1. If a container is used for weighing, it may be tared. In taring the container,
the scale subtracts the weight of the container from the gross weight to
obtain the net weight.
2.
To tare the weighing container, place it in the middle of the pan. The
container’s weight will be shown on the display, i.e.:
Note: Re-zeroing the scale will reduce the capacity of the scale by the re-
zeroed weight. The remaining capacity is displayed as a percentage on the
right side of the display.
Display indicating
the weight of the
container
I n s t r u c t i o n M a n u a l M o d e l D R X - 4
C H A P T E R 8

10
3. Once the stabilization indicator appears on the display, the container is
ready to be tared. To tare the container, press the “T” button. The display
will show a dotted line which indicates the scale has begun the taring
process, i.e.:
4. When finished taring, the balance will return to Weighing Mode. The
display will indicate 0, and the NET indicator will be shown on the display
signaling the next weight taken is a NET result.
WARNING: Do not touch or move the scale during the taring process.
Display in the taring
process
Display after the
scale has been
tared
Note: Taring and re-zeroing are two completely separate functions. Once
the scale has been tared, it may not be re-zeroed until the tare is cleared.
I n s t r u c t i o n M a n u a l M o d e l D R X - 4

11
Clearing the Tare
1. To clear the tare, remove the tared object along with the NET weight from
the pan. The scale will then display a negative NET tare result.
2.
To clear the tare, press the T button.
Display indicating a
negative tare result
3.
The display will show dashed lines indicating the tare is clearing.
Display in the tare
clearing process
4.
When finished clearing the tare, the scale will return to Weighing Mode.
Display in Weighing
Mode after the tare
has been cleared
I n s t r u c t i o n M a n u a l M o d e l D R X - 4
C H A P T E R 9

12
Printing
1. Enter the Function menu by pressing the “F” key located on the front panel
of the scale.
2. The scale will display PRINT
Display indicating
the PRINT
command
3. To enter the Print Function press the “T” key while the command PRINT is
displayed.
Display indicating
the PRINT ON
command
4. The scale will display commands PR ON and PR OFF, appearing
sequentially every two (2) seconds, i.e.:
Display indicating
the PRINT OFF
command
The printing function is used to print data via the RS232 port. Data may be
printed via a printer or sent to PC software. The printing function is pre-set; it
is automatically enabled each time the scale is turned ON. To turn the printing
function OFF or ON, follow the steps below:
I n s t r u c t i o n M a n u a l M o d e l D R X - 4
C H A P T E R 1 0

13
6. To turn the Printing function “OFF”, press the “T” key while command
PR OFF is displayed.
5. To turn the Printing function “ON”, press the “T” key while command
PR ON is displayed.
Display indicating
the PRINT function
is enabled when
the “P” key is
pressed
After you have made your selection, the scale will automatically return to
Weighing Mode. Printing or Sending Data is initialized by pressing the “P” key
located on the front panel of the scale. If the Printing function is enabled, the
scale will display “PRINT” when the “P” key is pressed. If the printing function is
disabled, “PR OFF” will be displayed.
Display indicating
the PRINT function
is disabled when
the “P” key is
pressed
I n s t r u c t i o n M a n u a l M o d e l D R X - 4

14
Calibration
1. Once the scale has its power ON and is in Weighing Mode, use a flathead
screwdriver to gently remove the Calibration Seal Screw located in the
rear of the scale.
Display in
Calibration Mode
Calibration of the DRX-4 should be performed with a single accurate 100g
weight. To Calibrate the scale follow the directions below:
2. Once the screw has been removed and the calibration switch exposed,
use a pen or another pointing device to toggle the calibration switch to the
right (which is the ON position.)
3. Upon toggling of the calibration switch, the balance will go into Calibration
Mode. For approximately five (5) seconds the display will read CAL,
indicating the scale is in Calibration Mode.
I n s t r u c t i o n M a n u a l M o d e l D R X - 4
C H A P T E R 1 1

15
4. The scale will then automatically begin its taring procedure, and the word
“Taring” will appear on the display.
Display while taring
in Calibration Mode
5. Once the scale has finished taring, the display will read “Load, 100g” which
indicates a single 100-gram calibration weight should be loaded. “Load,
100g” appears sequentially every two (2) seconds.
WARNING: Do not touch or move the scale during the
taring process.
Display indicates to
“Load, 100g”
I n s t r u c t i o n M a n u a l M o d e l D R X - 4