IN THIS OPERATING MODE THE FLAME SENSOR IS IGNORED AND THE CONTROLLER WILL
NOT DETECT THE PRESENCE/LACK OF FLAME, BEING ESSENTIAL FOR THE OPERATOR TO
PAY SPECIAL ATTENTION TO THE CONTROL OF THE OVEN IN ORDER TO PREVENT GAS
ACCIDENTS.
Use the < or > keys to select the desired function. The value can be edited with a quick touch on the key.dddd
Use the< ou > to change the value and press the key with a quick touch when ready to save the dsse
configured value and return to the functions menu. To leave the configuration menu and return to the normal
operating mode(temperature indication), press (press and hold) until [----] is displayed.dddd
Access the installation configuration menu by pressing the key for 4 seconds until dddd
[Func]is displayed. When [CoD] is displayed press the key again (quick touch). Use dsdet
the< or > keys to enter the access code 231 and press (quick touch) again when ready.dddd
SET
SET
SET
SET
SET
SET
Enable fan thermal protection
Enables stand-by oven
functionality
If enable, monitors fan temperature. In
case of overheating, enters error mode,
switching off the outputs of the controller.
[ON,]= Fan thermal protection enable
[OFF]= Fan thermal protection disable.
Enables stand-by mode (switching off
control functions)
[i08]
[i09]
OFF
NO
ON
YES
-
-
ON
NO
U n i t s e l e c t i o n o f
temperature
Selects the temperature unit the controller
will use for its operation
[i03] ºC ºF -°C
Language selection
Selects the language the controller will use
to display messages:
[Port]= Portuguese
[,EnG]= English
[,ESP]= Spanish
[i04] PORT ESP -PORT
Enables external sound
alarm (buzzer)
Enables or disables the external audible
alarm (buzzer). If enabled, the internal
audible alarm (buzzer) will be disabled.
[i05] OFF ON -OFF
DESCRIPTION
FUN MIN MAX UNIT
DEFA
FUNCTION
Access Code (231) Required when you want to change
installation setup parameters.
[CoD]
Temperature sensor type
[i02]
0 9999 -0
tc_J tc_H -tc_J
Oven type selection
Selects the control type of the oven:
[ELE,]= Electric Oven
[GAS,]= Gas-fired Oven
[LEN,]= Wood-fired Oven
[i01] ELE LEN -GAS
Door digital input signal type [,NO,]- normally open contact (NO)
[,NC,]- normally closed contact (NC)
[i07] NO NC -NO
[i06] I n t e r n a l au d i b l e a l a r m
(buzzer) volume
Selects the sound intensity of the internal
audible alarm (buzzer)
[Min,]= low volume
[Med,]= medium volume
[HiGh]= high volume
MIN HIGH -HIGH
Defines the type of temperature sensor to
be used with the controller.
6.1 Oven: electric
In this operating mode the controller keeps the heating output on until the oven reaches the oven temperature
setpoint (SP). The heating output will be activated again when the temperature drops below the setpoint minus
the hysteresis (F04).
6.2 Oven: gas
In this operating mode the controller automates / monitors the flame ignition and thus the heating of the oven
through the activation of the gas output, ignition module, and flame sensor input. The controller keeps the heating
on until the oves reaches the oven temperature setpoint (SP).
Heating will be activated again when the temperature drops below the setpoint minus the Hysteresis (F04).
The controller permanently monitors the flame sensor to ensure the safe operation of the gas-fired oven. In this
way, if there are any abnotmalities, errors Er4 - Flame Sensor shorted with the burner and Er5 - Lack of
Flame are indicated. For more information, check item 9 (Signaling).
6.3 Oven: wood
In this operating mode the heating output works as an upper threshold alarm, indicating when the temperature
exceeds the value adjusted in Oven Temperature setpoint (SP). The audible alarm is also activated to warn the
user about the overheating. The output and audible alarm are switched off when the temperature drops below the
Oven Temperature setpoint (SP) inus the Hysteresis (F05) or when the key in the controller’s front panel is dddd
pressed.
6.4 Default Mode (standard)
!In this operating mode the controller performs the gas type control, however the flame sensor is ignored and the
controller will not monitor flame presence. The controller will not detect errors Er4 - shorted flame sensor and
Er5 - out of gas, resulting in an operating with less safety. NOTE: The Default Mode (standard) of operation is
available only when the type of oven is adjusted as gas. To execute this operating mode, check item 7.5 Enable
Default (standard) Mode of operation.
SET
Operating temperature / Control temperature
0 to 131ºF (0 to 55°C) / 14 to 932°F (-10 to 500°C)
Operating humidity 10 to 90% UR (without condensation)
Type J or K thermocouple (sold separately)
Fan PTC (sold separately)
Resolution 1ºC / 1ºF
Digital Input
Flame sensor
E1: door micro switch input
E2 : flame sensor input
Product dimensions / Cutout dimensions (mm)
75 x 75 x 100 (WxHxD) / 67.2 x 67.2
7 relay outputs: 5 (3)A / 250Vac 1/8HP
12Vcc / 30mA (max)
Power supply / Approximate consumption TO711F: 85~240Vac ± 10% (*) (50-60Hz) / 10VA
TO711FL: 12~24Vac/Vdc + 10% / 10VA
Thermostat and timer for the automation of forced convection ovens. This model provides control over gas,
electric, or wood powered ovens, configured through the setup menu. The preset mode provides 20
configurations to control the temperature, cooking time, and steam injection, making the oven ready for the most
varied types of cooking. TO-711F allows reversing the rotation direction of the fan to improve the uniformity of
the roast. The instrument, however, controls steam injection and lighting in the oven, and has an internal audible
alarm (buzzer) that signals, for example, the end of the roasting process. It also allows for the use of an external
audible alarm and temperature sensor for thermal protection of the fan, preventing it from overheating. The
ThermOn line is developed and produced with high-quality raw materials and stands out for its unique and
distinctive design and intuitive, user-friendly interface to facilitate its operation and configuration. It offers a
functions lock feature to prevent third parties from changing the parameters, air-tight front panel that provides
high protection against the entry of dirt and moisture, and more. Product conforming to UL Inc. (United States and
Canada).
Baking ovens, stoves;
SET
TO-711F
REC
Quick touch: Increases parameter value
when in programming mode;
Upper display: Indicates the
temperature measured by the
sensor or parameter configuration;
Lower display: Indicates the cooking time or parameter
configuration;
Te m p e r a t u r e u n i t s L E D
indicator;
Quick touch: Temperature
a n d c o o k i n g t i m e
adjustment;
Press and Hold: Access to the
advanced configuration;
Quick touch: Preset selection;
Press and Hold: Preset configuration;
Quick touch: Decreases parameter
value when in programming mode;
Quick touch: Steam activation;
Press and Hold: Steam activation time
adjustment;
* When the stand-by mode is enabled (I09 = YES)
Quick touch: Timer activation;
Press and Hold: Activates or deactivates
turbine output;
Pre ss a nd H old: Act iva tes or
deactivates the controller stand-by;
Functions lock LED indicator;
Preset use LED indicator;
Steam output on LED
indicator;
Timer activated LED
indicator;
Heating on indication LED;
Fan on indication LED;
SET
REC
Each key has an LED to indicate its
function. When the LED is on, it
indicates that the key is active and
can be pressed.
KEY FUNCTIONS
SET
LED
KEY
Ratings outputs for UL Applications
1 A Resistive,100,000 Cycles 240 Vac 24Vac / Vdc
24Vac / Vdc
24Vac / Vdc
24Vac / Vdc
24Vac / Vdc
24Vac / Vdc
24Vac / Vdc
24Vac / Vdc
24Vac / Vdc
24Vac / Vdc
240 Vac
240 Vac
240 Vac
240 Vac
240 Vac
240 Vac
240 Vac
240 Vac
240 Vac
0.5 A Pilot load, 100,000 Cycles
1/8 HP, 100,000 Cycles
1 A General purpose, 100,000 Cycles
1/8 HP, 30,000 Cycles
0.5 A Pilot load, 30,000 Cycles
1 A General purpose, 100 Cycles
1 A Tungsten, 30,000 Cycles
1/8 HP, 30,000 Cycles
0.5 Pilot load, 30,000 Cycles
Resistance 1 / Gas 1 / Alarm 1
Resistance 2 / Gas 2 / Alarm 2
Steam valve / Ignition
Lightbulb
Fan 1 / Fan 2
TO711F TO711FL
BEFORE INSTALLING THE CONTROLLER, WE RECOMMEND THAT YOU FULLY READ THE INSTRUCTION
MANUAL TO PREVENT POSSIBLE DAMAGE TO THE PRODUCT.
THROUGH CONTINUOUS DEVELOPMENT, FULL GAUGE CONTROLS RESERVES THE RIGHT TO CHANGE
THIS MANUAL INFORMATION AT ANY TIME WITHOUT PRIOR NOTICE.
THIS CONTROLLER IS NOT RESPONSIBLE FOR SAFETY WITH RESPECT TO ANY FLAME SENSOR, GAS
VALVE, OR SPARK IGNITER OF WHICH NEED TO HAVE SAFETY CERTIFICATES (RECOGNIZED IGNITION AND
GAS MODULE) IN ITS APPLICATION FOR FINAL USE. THE FLAME SENSOR, THE GAS VALVE OR SPARK
IGNITER IN THIS CONTROL WILL BE CONSIDERED SEPARATELY FROM THE THERMON CONTROLLER.
Heating BuzzerSteam Lighting Fan Functions
Block
Serial
programming
Protection
level
IP 65
FRONT
PresetsTimer
OVEN TIME AND TEMPERATURE CONTROLLER
TO711FV02-01T-17368
TO-711F
Ver.02
Have this manual in your hand
using the FG Finder app.
6. OPERATION
1. DESCRIPTION
2. APPLICATIONS
5.1 Installation setup table
4. INTRODUCTION
5. INSTALLATION CONFIGURATION
3. TECHNICAL SPECIFICATIONS
E251415
Relay outputs
Temperature sensor
External audible alarm (buzzer) outputs
Thermal protection sensor
ADJUSTMENT OF THE DESIRED TEMPERATURE (SETPOINT) OF
THE OVEN:
Defines the working temperature of the oven. This parameter can be adjusted between the
values defined in F02- Minimum value allowed to configure the oven temperature setpoint and
F03 - Maximum value allowed to configure the oven temperature setpoint.
TIMER ADJUSTMENT:
Defines the cooking time. When the time expires, the audible alarm output is switched on
intermittently until any key on the controller’ s front panel is pressed. The timer can be adjusted
between 00:01 and 99:59. The time scale is adjusted in parameter F14 - Time base of the timer.
7.2 Steam activation
The steam operating mode is defined in parameter F18 - Steam Operating Mode. Steam activation depends on
parameters F20 - Time interval between steam activations and F21 - Minimum temperature to activate the steam,
available in the advanced configuration menu. These conditions must be met for the injection of steam in the oven
to occur.
7.2.1 Steam activation times
Press the % key and hold for 4 seconds to adjust. Use the < and > keys to adjust the value of the parameter.
To confirm, perform a quick touch on the%key.
STEAM OUTPUT ON TIME:
This parameter can be adjusted between 1 and 30 seconds, and the factory default is 5
seconds.
STEAM OUTPUT OFF TIME:
This parameter can be adjusted between 1 and 600 minutes, and the factory default is 3
minutes.
NOTE: This parameter is available for adjustment when the steam control mode selected is
cyclic [F18]=[CYC,].
7.3 Presets
A preset includes the configuration of oven temperature, timer, and steam operating mode. The controller has 20
presets that can be edited by the user, and the presets can be selected in a simplified way.
7.3.1 Preset selection
7.3.2 Preset configuration
To access the preset configuration menu, keep the key pressed down for 4 seconds. Then use < or > to ddddd
select the parameter to be adjusted, use the key to access the parameter, and then use < or > to adjust dddd
the value of the parameter. To leave the preset menu and return to the normal operating mode (temperature and
time indication), keep the key pressed down (press and hold) until [----]is displayed.ddddd
To select a preset in the controller, perform a quick touch on the key and then use < or ddddd
>to select the desired preset.
- QUICK TOUCH: cancel preset selection;
- PRESS AND HOLD: confirm preset selection;
The * icon indicates that the preset mode is active.
REC
REC
REC
REC
REC
REC
FAN CONTROL MODE:
Selects the control mode for the fan:
[ON,]= On, the fan is controlled via output FAN 1.
[ALT]= Alternated, reverses the rotation direction of the fan via outputs FAN 1 and FAN 2, in i
accordance with parameters F23 and F24.
Turbine shutdown option: If option I09 - Enable the stand-by oven function is set to ‘’YES’’, the turbine output
can be temporarily disabled in the following ways:
- Manual shutdown : Press the < key and hold for approx. 4 seconds.
- Automatic shutdown: Via function F26 - Automatic turbine shutdown after completion of the cooking
time the turbine can be temporarily disabled after completion of the cooking process timer;
The turbine output will remain deactivated respecting the time set in function F25 - Maximum turbine off time after
deactivation and while the timer is not activated, otherwise the turbine will also be activated again. While it is off, a
message will appear on the lower display informing that the turbine is off. You can activate the turbine output
again at any time by pressing < again for 4 seconds.
However, turning off the turbine is only allowed while the timer is deactivated, otherwise an error message will be
displayed indicating that the turbine cannot be switched off.
Selects the number of the preset to be
configured. There are 20 presets that can
be customized by the user.
Select the preset to be
configured 120 -1
7.3.2.1 Preset configuration table
8.2 Parameters table
8.1 Changing the controller parameters
MIN
MIN
MAX
MAX
UNIT
UNIT
DEFA
DEFAU
DESCRIPTION
DESCRIPTION
FUN
FUN
FUNCTION
FUNCTION
[rCnF]
Adjustment of the timer for the preset
selected by parameter [rCnF].
Defines the steam operating mode for the
selected preset [rCnF]:
[OFF,]Off: does not inject steam.
[MAN,]M anual: injects steam when the
%key is pressed.
[AUT,] Automatic: automatically injects
steam after the timer is activated. The
steam is activated after the time set in F19
has elapsed.
[CYC,]Cyclic: injects steam in cycles
using the times configured in[UAon]
and[UAof].
OFF CYC -MAN
Oven temperature setpoint
for the selected preset
Adjustment of the oven temperature
setpoint for the preset selected by
parameter [rCnF].
ºC
(ºF)
180
(356)
Timer adjustment for the
selected preset
[rtm,] 00:01 99:59 F14 18:00
Steam operating mode for
the selected preset
[rUa,]
[,rsP] (F02) (F03)
7.4 Functions lock
To enable / disable the function lock, press < and > and hold for the time configured in
parameter. F28 - Time for function lock.
When this configuration is active, the parameters cannot be changed, but they can be viewed.
When the lock is active, the parameters available for adjustment are defined in parameter F27
- Functions Lock.
Icon& indicates the status of the lock. Icon lit indicates the functions lock is active.
To enable the Default (standard) operating mode of the oven, the controller must be powered
up with the $ and % keys pressed until the message appears on the display. This mode is
available when the type of oven selected is GAS. For more details about this operating mode
check item 6.4 Default Mode (standard).
7.5 Enable Default (standard) operating mode
IN THIS OPERATING MODE THE FLAME SENSOR IS IGNORED AND THE CONTROLLER WILL
NOT DETECT THE PRESENCE / LACK OF FLAME, BEING ESSENTIAL FOR THE OPERATOR TO
PAY SPECIAL ATTENTION TO THE CONTROL OF THE OVEN IN ORDER TO PREVENT GAS
ACCIDENTS
7.6 STAND-BY Function
When function I09 - Enable stand-by oven functionality is set to YES, the controller can be put on standby at
any time by the user. This functionality allows for the control to be kept disable (all outputs off). To put the
controller on stand-by mode, press > for approx. 4 seconds, until the message [OFF] is displayed.
While the controller is on stand-by, the display will flash the > key icon to indicate for the key to be pressed
againd for 4 seconds to reactivate the oven control.
Use the < or > keys to select the desired function. The value can be edited with a quick touch on the dddd
key. Use the < or > keys to change the value and press the key with a quick touch when ready to save the
configured value and return to the functions menu. To leave the configuration menu and return to the normal
operating mode (temperature and time indication), press (press and hold) until [----]is displayed.dddd
Access the advanced configuration menu by pressing the key for 4 seconds until dddd
[FuNc]is displayed. When [CoD] is displayed press the key again (quick touch). Use the <
or > keys to enter the access code 123 and press (quick touch) again when ready. dddd
8. OPERATIONS - ADVANCED LEVEL
SET
SET
SET
SET
Access Code (123) Required when you want to change the advanced
configuration parameters.
[CoD] 0 9999 -0
Temperature sensor indication
offset
Allows compensating deviations in the
sensor temperature reading.
[F01] -20
(-4)
20
(36)
°C
(°F)
0
(0)
These parameters serve as the lower and
upper thresholds for the adjustment of
parameter ‘’SP’’ - oven temperature
set point. Th ey a re used to block
temperature adjustments and to avoid an
improper configuration for the operation of
the oven.
Minimum value allowed to
c o n f i g u r e t h e o v e n
temperature setpoint
Maximum value allowed to
c o n f i g u r e t h e o v e n
temperature setpoint
[F02]
[F03]
-10
(14) F03 °C
(°F)
0
(32)
F02 500
(932)
°C
(°F)
230
(446)
Oven temperature differential
(Hysteresis)
The temperature difference to switch on
the heating output. This function allows
defining a temperature interval within
which the heating output will remain off.
[F04] 1
(1)
20
(36)
ºC
(ºF)
3
(5)
Delay to switch off the
temperature control
when the door of the
oven is opened
Defines the delay to switch off the
temperature control when the oven door is
opened to allow furnishing the oven without
switching off the control. To disable this
function, change the adjustment to the
minimum until [no,]is displayed. In this
case, the temperature control is switched
off as soon as the door is opened.
[F05] no(0) 180 sec.
Number of attempts to light the
flame (GAS-FIRED OVEN)
Defines the maximum number of attempts
the controller will try to ignite the flame.
After using up all attempts, the controller
will signal error [ER5]-Out of Gas.
Note: This parameter is used when the
type of oven selected is GAS.
[f06] 15-
Ignition output on time (GAS-
FIRED OVEN)
Defines the time the ignition output will stay
switched on to try to ignite the flame.
Note: This parameter is used when the
type of oven selected is GAS.
[f07] 115 sec.
90
3
3
Delay to activation of the
i g n i t i o n o u t p u t a f t e r
controller start up (GAS-
FIRED OVEN)
Defines the delay to activate the ignition
output after the gas output is activated in
the first attempt to ignite the flame. This
time is used so that the gas from the
cylinder reaches the burner and then the
ignition is activated.
Note: This parameter is used when the
type of oven selected is GAS.
[F09] no
(0) 15 sec. no(0)
Interval between activations
of the ignition output (GAS-
FIRED OVEN)
Defines the interval between attempts to
activate the flame.
Note: This parameter is used when the
type of oven selected is GAS
[f08] 115 sec. 3
Delay of the temperature
control after controller start
up (GAS-FIRED OVEN)
When the controller is powered up, the fan
is actived first and then the flame ignition
process commences after the time
adjusted in this parameter has elapsed.
Note: This parameter is used when the
type of oven selected is GAS.
[F10] no
(0) 30 sec. 1
The controller has easy access to resources that are relevant to the user of the oven.
7.1 Adjustment of oven temperature and timer
To adjust oven temperature and timer, perform a quick touch on the SET key. Use the < and > keys to adjust the
value of the parameter. To advance and/or terminate the adjustement, perform another quick touch on the SET
key.
7. OPERATIONS - BASIC LEVEL
Timer trigger mode
Defines the timer triggering mode:
[MAN]= Manual, through the $key.
[INI]= Start up, when the controller is
powered up.
[TMP]=Temperature, when the oven
working temperature is reached.
Note: In modes [INI] and [TMP] the$
key only cancels the timer.
[F12] MAN TMP -MAN
Timer counting direction
Defines the direction the timer counts:
[DEC] = time count down;
[CRE] = time count up;
[F13] DEC CRE -DEC
Timer time base
Defines the time base of the timer:
[MM:SS]= minutes, maximum time
99:59 minutes;
[HH:MM] = hours, maximum timer 99:59
hours.
[F14]
HH:MM
HH:MM
-
-
MM:SS
MM:SS
MM:SS
MM:SS
Timer reset mode
Defines the timer reset mode, essentially
wheter the audible alarm will be switched
off manually or by time:
[MAN]=Manually through the$key;
[AUT]=Automatically according to the
time defined in parameter F17;
Note: The timer also resets when the door
of the oven is opened, independently of the
mode defined in this parameter.
[F15] MAN AUT -MAN
Timer reset time base
Defines the time base when the timer is
reset:
[MM:SS]= minutes, maximum time 99:59
minutes;
[HH:MM]= hours, maximum time 99:59
hours.
[F16]
Time to reset the timer
(aut mode)
Defines the time to reset the timer if
automatic reset is selected in parameter
F15
[F17] 0:01 99:59 F16 0:05
MIN MIN
MAX MAX
UNIT UNIT
DEFAU
DEFA
DESCRIPTION DESCRIPTION
FUN FUN
FUNCTION FUNCTION
Steam working mode
Defines the steam operating mode for the
selected preset [rCnF]:
[OFF,]Off: does not inject steam.
[MAN,]M anual: injects steam when the
%key is pressed.
[AUT,] Automatic: automatically injects
steam after the timer is activated. The
steam is activated after the time set in F19
has elapsed.
[CYC,]Cyclic: injects steam in cycles
using the times configured in [UAon] and
[Uaof].
Note: When the preset mode is active, this
configuration is made in menu [rUa,].
[F18] OFF CYC -MAN
Delay to activate the
automatic steam
Defines the delay before injecting steam
into the oven after the timer is activated.
This parameter is valid when automatic
steam is adjusted in parameter F18.
[f19] 1180 sec. 5
Time interval between
steam activations
Defines the minimum time interval between
steam activations, i.e. once the steam
output is activated, the controller will not
activate it again before the time adjusted in
this parameter has elapsed. To disable this
function, change the adjustment to the
minimum until [no,]is displayed.
Note: This parameter is disregarded when
the type of steam selected is cyclic.
[f20] no(0) 30 min. no(0)
Minimum temperature to
activate the steam
Defines the minimum temperature in the
oven to allow activating the steam output.
To disable this function, change the
adjustment to the minimum until [no,]is
displayed.
[f21]
no(-10)
no(14)
500
(932)
ºC
(ºF)
100
(212)
Economic mode - oven idle
time to switch of the light
Defines the time the oven has to be idle
before the controller enters in Economic
Mode (ECO). When the lightbulb output is
switched off. Press to leave the ECO dddd
mode.
[f22] no(0) 60 min. 15
Fan output on time Defines the time the fan will stay active in
each direction.
[f23] 60 600 sec. 180
Fan output off time
It must be adjusted with the time required
for the fan to stop, so that the rotation
reversion can be performed smoothly.
[f24] 530 sec. 15
SET
Maximum turbine off time
after deactivation
Automatic shutdown of the
turbine after completion of
the cooking time
Set the maximum time that the turbine
output will stay off after being manually
deactivated by the user or automatically
deactivated (case F26 and I09 are set to
YES) after the time of the process timer has
elapsed.
Note:The turbine can be switched off
manually or automatically only after the
process time has elapsed and the timer is
reset. If the timer is activated, the turbine
will be restarted.
Enables the option to automatically switch
off the turbine output after the timer
process time has elapsed (case I09 is set
to YES).
Note: The turbine will only be switched off
after resetting the timer and the output will
remain off for the time set in function F25 or
until the timer is activated.
[f25]
[f26]
1
NO
60
YES
MIN.
-
20
NO
Defines the functions lock mode:
[OFF,]= functions lock disabled;
[LOC1]= partial functions lock 1 -
pr ev en ts adva nc ed c on fi gu ra tio n
parameters from being changed;
[LOC2]= partial functions lock 2 -
prevents controller parameters from being
changed, only allowing changing presets;
[FULL] = full functions lock, does not
allow any parameter adjustment.
Timer for function lock
Defines the time to lock / unlock the
functions. For more information, see item
7.4 - Functions Lock.
[f28] 130 sec. 10
Functions lock
[f27] -
OFF FULL -LOC1
9. SIGNALING
Upon power up the controller indicates the operating mode of the oven.
9.1 Operating mode signaling
9.2 Programming signaling
Eletric Oven
Controller configured with the electric oven logic.
Gas-fired Oven
Controller configured with the gas-fired oven logic.
Wood-fired Oven
Controller configured with the wood-fired oven logic.
Controller configured with gas-fired oven logic with Default (standard) mode enabled,
without flame sensor monitoring. For more information, see item 7.5 Enable Default
(standard) operating mode.
Default Mode (standard)
Functions lock active
Does not allow adjusting the parameter
To deactive functions lock, see item 7.4 - Functions lock.
Parameter adjustment denied
Enter access code in parameter [Cod]to adjust the parameter value.
Receiving data via EasyProg* (programming key)
Updating the parameter table via EasyProg*.
*sold separately
9.3 Process signaling
If the controller detects an error that interferes in the operation of the system, the controller switches off the
outputs, switches on the audible alarm intermittently, and indicates the detected failure on the display. To leave
error mode, the controller must be switched off, the fault corrected, and the controller switched on again.
Note: In case the I09 -Enable stand-by oven functionality function has been set as YES, press the>key
during the error signaling to put the controller in stand-by and reboot it after the informed error is corrected.
Measure:
Contact Full Gauge Controls.
Measure:
Contact Full Gauge Controls.
Reason: Temperature sensor disconnected or out of range.
Measure: Check sensor connections and operation.
Reason: Flame sensor shorted with the burner.
Measure: Check wheter the flame sensor is making contact with the burner.
Delay of the temperature
control (GAS-FIRED OVEN)
When the controller tries to ignite the flame,
for example after the door is opened, the fan
is activated first and then the flame ignition
process commences after the time adjusted
in this parameter has elapsed.
Note: This parameter is used when the type
of oven selected is GAS.
[F11] no
(0) 30 sec. 5
Reason: Out of gas, the controller does not detect a flame.
Measure: First check if there is gas available for the oven to operate.
Check the presence of flame and the distance between the flame sensor and the burner.
Other possibilities for this failure are: flame sensor disconnected or dirty / oxidized, damaged
ignition module or gas valve.
9.4 Other signaling
Controller in Economic mode. The controller was idle for the time adjusted in F22 - Economic
Mode. To leave this mode, press or open the oven door.dddd
Note: This message is displayed alternately with the oven temperature.
Indicates that the oven door is open.
Note: The message keeps flashing on the lower display.
Requests for the operator to close the oven door. Indicates that the
door remained open for the time configured in parameter F05. In
this mode the controller switches off the heating and activates the
audible alarm.
Note: The message keeps flashing on the lower display.
SET
Reason: Fan overheating, its temperature has exceeded the rated temperature of the termal
protection PTC sensor.
Measure: Check the operation of the fan and respective temperature sensor.
Note: If the thermal protection sensor is not used, connect terminals 3 and 4 with a
connection and / or deactivation parameter [i08] - Enable fan thermal protection.
Manual turbine shutdown not allowed.
The message will be displayed if turbine shutdown is attempted while the timer is active.
Indicates that the turbine of the oven is temporarily off. To restart
the turbine, press < for 4 seconds or activate the timer.
Note: The message keeps flashing on the lower display.
10.1.2 Oven: gas
10.1.3 Oven: wood
PRECAUTIONS WHEN INSTALLING THE PRODUCT:
10.1.1 Oven: eletric
Before performing any procedure on this instrument, disconnect it from the power grid;
Ensure that it has adequate ventilation, avoid installation on control panels containing devices that could
cause it to operate outside its specified temperature range;
Install the product away from sources that may generate electromagnetic disturbances, such as:
motors, contactors, relays, solenoid valves, etc.
IMPORTANT:
It is crucial to install the ignition module next to the burner and as far as possible from the electronic
controller;
The ignition electrode must be installed at a distance of 5 mm from the burner;
The flame sensor must be installed at a distance of 5 mm from the burner and at least 5 mm from the
ignition electrode.
123 4
Fan
PTC
J or K
Thermocouple
E1: Door micro switch input
B1: External audible alarm (buzzer)
18 17 16 15 14 13 12 11 10
9 8 7 6 54 3 21
Check the controller model
RESISTANCE 2
FAN 2
FAN 1
LIGHTBULB
STEAM
E1
B1
RESISTANCE 1
* Fan PTC:
RTN = 1000Ω
RTN (TN - 5K) = max 550Ω
RTN = Resistance at rated
temperature
P+
12~24Vac / Vdc
-
85~240Vac
N
123 4
Fan
PTC
J or K
Thermocouple
E1: Door micro switch input
E2: Flame sensor
B1: External audible alarm (buzzer)
Q: Burner
18 17 16 15 14 13 12 11 10
9 8 7 6 54 3 21
GAS 2
FAN 2
FAN 1
LIGHTBULB
IGNITION
STEAM
GAS 1
E1
Q
E2
B1
Check the controller model
* Fan PTC:
RTN = 1000Ω
RTN (TN - 5K) = máx 550Ω
RTN = Resistance at rated
temperature
+
12~24Vac / Vdc
-
P
85~240Vac
N
123 4
Fan
PTC
J or K
Thermocouple
18 17 16 15 14 13 12 11 10
9 8 7 6 54 3 21
ALARM 2
FAN 2
FAN 1
LIGHTBULB
STEAM
ALARM1
Check the controller model
* Fan PTC:
RTN = 1000Ω
RTN (TN - 5K) = máx 550Ω
RTN = Resistance at rated
temperature
+
12~24Vac / Vdc
-
P
85~240Vac
N
E1
B1 E1: Door micro switch input
B1: External audible alarm (buzzer)
10. INSTALLATION
12. EasyProg* - version 02 or later
11. DIMENSIONS
10.1 Electrical connections
75,6
75,4
Panel openings
67,2 mm
67,2 mm
25 mm
10 mm
Packaging:
Materials used in the packaging of the Full Gauge products are 100% recyclable. Be sure to dispose of using specialized recycling
facilities.
Product:
The components used in the Full Gauge controllers may be recycled and reused if disassembled by specialized companies.
Disposal:
Do not incinerate or dispose of the controllers that reached the end of their service life in household waste. Be sure to comply with
the existing legislation in your area relating to disposal of electronic waste. In the event of doubt, please contact Full Gauge
Controls.
ENVIRONMENTAL INFORMATION
67
100,3
75
80
84,8
Side view
Front view
WARRANTY - FULL GAUGE CONTROLS
Products manufactured by Full Gauge Controls, as of May 2005, have a two (2) - year waranty directly with the factory and
one (1) year before the reseller network, counted as of the date of consigned sale as stated on the invoice. After this said year
before the reseller network, the warranty shall continue to be executed if the instrument is sent directly to Full Gauge Controls.
The products are warranted in case of defects in workmanship making them unsuitable or inadequate to the intended
applications. The warranty is limited to maintenance of instruments manufactured by Full Gauge Controls, disregarding other
kinds of expenses, such as indemnity for damages caused to other equipment.
EXCEPTIONS TO WARRANTY
The Warranty does not cover expenses incurred for freight and / or insurance for sending the products with signs of defect
or malfunctioning to the provider of technical support services. The following events are also excluded from warranty: natural
wear and tear of parts, external damages caused by falls or inadequate packaging of products.
INVALIDATION OF WARRANTY
The product warranty shall lose validity, automatically, if:
- The instructions for use and assembly contained in the technical description and the installation procedures described in
Standard NBR5410 are not followed;
- The product is submitted to conditions beyond the limits specified in its technical description;
- The product is violated or repaired by a person not integrating the technical team of Full Gauge;
- The damages are due to a fall, blow and / or impact, water damage, overload and / or atmospheric discharge.
USE OF WARRANTY
For use of the warranty, the customer should send the adequately packaged product, along with the respective Invoice to
Full Gauge Controls. The customer will bear the freight cost for sending of the products. Also, as much information as possible
with regard to the defect verified should be sent, in order to facilitate the analysis, the testing and the performance of the
service.
These processes and any product maintenance shall only be performed by the Technical Support Services of Full Gauge
Controls, at the Company headquarters - Street Júlio de Castilhos, 250 - CEP 92120-030 - Canoas - Rio Grande do Sul - Brazil.
Rev. 03
Copyright 2018
It is an accessory the main function of which is to store the parameters of
controllers. At any time you can load new parameters of a controller and unload
them on a production line (of the same controller), for example.
It is provided with three types of connections for loading or unloading the
parameters:
- Serial RS-485: It is connected via RS-485 network to the controller (only for those
controllers provided with RS-485).
- USB: It is connected to the computer via USB port, using the Sitrad Preset Editor.
- Serial TTL: The controller may be connected directly to EasyProg via Serial TTL
connection.
EASYPROG
*sold separately

Other Full Gauge Controls Thermostat manuals

Full Gauge Controls RT-607Ri plus User manual

Full Gauge Controls

Full Gauge Controls RT-607Ri plus User manual

Full Gauge Controls Microsol BMP Advanced User manual

Full Gauge Controls

Full Gauge Controls Microsol BMP Advanced User manual

Full Gauge Controls Microsol SWP Advanced User manual

Full Gauge Controls

Full Gauge Controls Microsol SWP Advanced User manual

Full Gauge Controls Microsol BMP Advanced c-o-n-n-e-c-t User manual

Full Gauge Controls

Full Gauge Controls Microsol BMP Advanced c-o-n-n-e-c-t User manual

Full Gauge Controls Microsol RST Advanced User manual

Full Gauge Controls

Full Gauge Controls Microsol RST Advanced User manual

Full Gauge Controls Microsol SWP Advanced c-o-n-n-e-c-t User manual

Full Gauge Controls

Full Gauge Controls Microsol SWP Advanced c-o-n-n-e-c-t User manual

Full Gauge Controls RT-607RiL power User manual

Full Gauge Controls

Full Gauge Controls RT-607RiL power User manual

Full Gauge Controls Microsol FLT Advanced User manual

Full Gauge Controls

Full Gauge Controls Microsol FLT Advanced User manual

Full Gauge Controls Microsol RST Advanced c-o-n-n-e-c-t User manual

Full Gauge Controls

Full Gauge Controls Microsol RST Advanced c-o-n-n-e-c-t User manual

Full Gauge Controls Microsol Ri User manual

Full Gauge Controls

Full Gauge Controls Microsol Ri User manual

Full Gauge Controls Microsol Ri User manual

Full Gauge Controls

Full Gauge Controls Microsol Ri User manual

Full Gauge Controls ANASOL 115vac Operator's manual

Full Gauge Controls

Full Gauge Controls ANASOL 115vac Operator's manual

Popular Thermostat manuals by other brands

Carrier N-MC-FC Product data sheet

Carrier

Carrier N-MC-FC Product data sheet

Tekmar tekmarNet 552 user manual

Tekmar

Tekmar tekmarNet 552 user manual

Namron 4512752 instruction manual

Namron

Namron 4512752 instruction manual

ICM Controls SC3000L user manual

ICM Controls

ICM Controls SC3000L user manual

Honeywell RET97B5D user guide

Honeywell

Honeywell RET97B5D user guide

EWC Controls EWT-3900 Ultra-Zone Technical bulletin

EWC Controls

EWC Controls EWT-3900 Ultra-Zone Technical bulletin

Honeywell T7047C installation instructions

Honeywell

Honeywell T7047C installation instructions

Aprilaire 8533 owner's manual

Aprilaire

Aprilaire 8533 owner's manual

Bpt TH 450 Instructions for use

Bpt

Bpt TH 450 Instructions for use

TCS Basys Controls SZ1017a product manual

TCS Basys Controls

TCS Basys Controls SZ1017a product manual

Crestron CHV-TSTAT Operation and installation guide

Crestron

Crestron CHV-TSTAT Operation and installation guide

Honeywell Y87RFC user guide

Honeywell

Honeywell Y87RFC user guide

INSTEON 2441ZTH quick start guide

INSTEON

INSTEON 2441ZTH quick start guide

Johnson Controls T7000e installation guide

Johnson Controls

Johnson Controls T7000e installation guide

Emerson White-Rodgers 1E78 installation instructions

Emerson

Emerson White-Rodgers 1E78 installation instructions

Salus iT500 manual

Salus

Salus iT500 manual

American Standard ASYSTAT300C owner's guide

American Standard

American Standard ASYSTAT300C owner's guide

ELEKTROBOCK BPT22 manual

ELEKTROBOCK

ELEKTROBOCK BPT22 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.