Questions? Please Contact Your Local Manufacturer’s Representative
EDR-IOM-2019-0212 TABLE OF CONTENTS
0-1
Introduction 1-1
Overview .............................................................................................................. 1-2
Warnings & Cautions............................................................................................ 1-2
Disclaimers and Local Codes ................................................................................ 1-2
Installation 2-1
Product Overview................................................................................................. 2-2
Placement & Rigging........................................................................................... 2-3
Clearances and Serviceability .............................................................................. 2-5
Install BoilerTrim ................................................................................................. 2-5
InstallWater Piping.............................................................................................. 2-6
VARIABLE PRIMARY PIPING ARRANGEMENT............................................................................27
PRIMARYSECONDARY PIPING ARRANGEMENT......................................................................210
MeetWater Chemistry Requirements................................................................ 2-10
PREVENT OXYGEN CONTAMINATION........................................................................................211
ELIMINATE SYSTEM AIR ............................................................................................................212
Fill the BoilerWithWater ................................................................................... 2-12
Gas Supply Piping .............................................................................................. 2-12
INLET GAS PRESSURE................................................................................................................213
GAS PRESSURE REQUIREMENTS...............................................................................................213
LINE GAS PRESSURE REGULATION............................................................................................213
COMPONENTS REQUIRING VENTILATIONTOTHE OUTDOORS ...............................................216
Install Condensate DrainTrap............................................................................. 2-16
SINGLE BOILER DRAINTRAP.....................................................................................................216
MULTIPLE BOILERS SHARING A COMMON DRAINTRAP .........................................................216
Install pH Neutralization Kit............................................................................... 2-19
Venting Requirements....................................................................................... 2-21
Combustion Air Intake ....................................................................................... 2-22
COMBUSTION AIR SUPPLY FROM THE BOILER ROOM..............................................................223
AIR PIPED FROM OUTSIDE BOILER ROOM................................................................................224
Air Filter.............................................................................................................. 2-25
ExhaustVenting ................................................................................................. 2-25
COMMONVENTING LAYOUTS FOR ENDURA.............................................................................228
VENTINGTERMINATIONS ..........................................................................................................232
WALLTHIMBLE INSTALLATION.................................................................................................232
ROOFVENTTERMINATION.........................................................................................................232
SIDEWALL VENT TERMINATION................................................................................................232
Removing an Existing Boiler ............................................................................. 2-33
Assembly of Fulton Multi-Skid Systems............................................................. 2-34
Electrical Connections and Devices.................................................................... 2-35
JUNCTION BOX LOCATIONS FOR FIELD WIRING .......................................................................240
ELECTRICAL AND CONTROLS OPTIONS.....................................................................................240
Operation 3-1
Perform Pre-Start-Up Inspection......................................................................... 3-2
Fill and Purge the System..................................................................................... 3-2
CommissionThe Boiler......................................................................................... 3-3
SYSTEM DESIGN AND BOILER OPERATION.................................................................................33
CommissionThe Boiler: Zero Governing GasValve .............................................. 3-4
TURNDOWN.................................................................................................................................37
SOLA Hydronic Controller - General Operation .................................................... 3-8
STATUS SUMMARY SCREEN.........................................................................................................38
CENTRAL HEAT OPERATION SCREEN...........................................................................................38
CENTRAL HEAT OPERATION SETPOINT SCREEN.....................................................................310
CENTRAL HEAT CONFIGURATION SETPOINT SCREEN ...........................................................310
CENTRAL HEAT CONFIGURATION MODULATION SCREEN ....................................................310
CHANGING HIGH LIMIT SETPOINT ANDVERIFYING CHANGE..................................................311
REVIEWING STATISTICS.............................................................................................................313
ACCESSING LOCKOUT HISTORY .................................................................................................314
SOLA DIAGNOSTICS...................................................................................................................316
SOLA Hydronic Controller - Options Conguration............................................ 3-17
LEAD/LAG INTEGRATED SEQUENCING .....................................................................................317
DOMESTIC HOTWATER DHW TEMPERATURE SENSOR..........................................................321
REMOTE 420 MA SIGNAL FOR SETPOINT ................................................................................322
SUPPLY HEADERTEMPERATURE SENSOR ................................................................................323
OUTDOOR AIRTEMPERATURE SENSOR ....................................................................................324
STACK LIMIT...............................................................................................................................326
DEDICATED BOILER PUMP.........................................................................................................327
MOTORIZED ISOLATION VALVE SET UP .....................................................................................328
ENABLING BURNER FIRE RATE OUTPUT ...................................................................................329
SYSTEM PUMP ENABLE/DISABLE SIGNAL ...............................................................................329
PerformTest of LowWater Cut O ..................................................................... 3-31
PerformTest of Limit Controls ........................................................................... 3-31
PerformTest of Low Gas Pressure Switch .......................................................... 3-31
PerformTest of High Gas Pressure Switch.......................................................... 3-31
General Operation of the Boiler ......................................................................... 3-31
Maintenance 4-1
General................................................................................................................. 4-2
Daily Inspection Schedule ................................................................................... 4-2
Weekly Maintenance Schedule ........................................................................... 4-2
Monthly Maintenance Schedule.......................................................................... 4-2
Procedure for Inspecting the Air Inlet Filter ....................................................... 4-3
Annual Maintenance Schedule............................................................................ 4-3
Replacing GasValve Internal Filter....................................................................... 4-4
Removing and Cleaning Burner Assembly .......................................................... 4-5
Verication of Ignition Gap.................................................................................. 4-6
After All Repairs and Maintenance ...................................................................... 4-7
Troubleshooting................................................................................................. 4-10