J OIL-E-08 2008
SAFETY
The instructions provided for the operation and maintenance of the boiler MUST be observed.
Failure to do so could result in damage to the boiler and serious personal injury.
WARNING
Do not try to do repairs or any other maintenance
work you do not understand. Obtain a Service Manual
from Fulton or call a Fulton Service Engineer
WARNING
It is the responsibility of the installer to ensure all parts
suppliedwiththeboilerarettedinacorrectandsafe
manner.
WARNING
Understand the electrical circuit before connecting or
disconnecting an electrical component. A wrong con-
nection can cause injury and or damage.
WARNING
Adefective boiler caninjure youorothers.Donotoperate
a boiler which is defective or has missing parts. Make
sure that all maintenance procedures are completed
before using the boiler.
WARNING
Do not change the boiler fuel without consulting the
boiler manufacturer.
WARNING
LIFTING EQUIPMENT
Make sure that lifting tackle complies with all local
regulations and is suitable for the job
You can be injured if you use faulty lifting equipment.
Make sure the lifting equipment is in good condition.
WARNING
Operating the boiler beyond its design limits can dam-
age the boiler, it can also be dangerous. Do not operate
the boiler outside its limits. Do not try to up grade the
boilerperformancebyunapprovedmodications.
WARNING
Non-approved modications can cause injury and
damage. Contact your Fulton dealer before modifying
the boiler.
WARNING
Only qualied persons should be allowed to
operate and maintain the boiler and its
equipment. Boilers should always be drained through
an approved Blowdown Vessel.
WARNING
HYDRAULIC TEST -
RISK OF BRITTLE FRACTURE
Hydraulic testing requires specialist equipment and is
normally only required by engineering surveyors / in-
spectors. The material the boiler is manufactured from,
has not been impact tested, as it is not a requirement
of BS2790 (boiler construction standard). In order to
ensure the material / pressure vessel does not suffer
from brittle fracture, hydraulic testing should not be
carried out below 5OC.
WARNING
DANGER FROM HOT SURFACES
Steam Boilers have high temperature surfaces, that if
touched may cause serious burns. Only competent
andqualiedpersonnelshouldworkonorinthelocal-
ity of a steam boiler and ancillary equipment. Always
ensuretheworkingareaandoorareclearofpotential
hazards, work slowly and methodically.
WARNING
DANGER FROM INCOMPLETE COMBUSTION
The importance of correct burner adjustment to achieve
lowemissions,safe,cleanandefcientcombustionis
paramount. Poor combustion, where unburnt oil forms
carbon monoxide is both a health hazard, and the
potential risk to the boiler from overheating, caused
by re-burning of the unburnt gas in the secondary
uepasses.
WARNING
The importance of correct boiler water and feed water
cannot be over emphasised, see the relevant section
in this manual.
CAUTION
LOW FEED WATER TEMPERATURE
Low feed water temperature can result in thermal shock
to the boiler pressure vessel. Return the maximum
amount of condensate and if necessary pre-heat the
feed water. If in doubt consult FBW.
CAUTION
WATER SOFTENER and CHEMICAL TREATMENT
The chemicals required to operate the water softeners and
chemical treatment plants are NOT SUPPLIED by Fulton.
It is the responsibility of the operator to ensure adequate
supplies of chemical are available at all times (including
commissioning).
Costly repairs could be required should the plant
operate without chemicals or the wrong dosage of
chemicals.
CAUTION
Obey all laws and local regulations which affect you
and your boiler.