Questions? Call (315) 298-5121, or visit us online at www.fulton.com
VTG-IOM-2013-0815 TABLE OF CONTENTS
0-1
Introduction 1-1
Overview .............................................................................................................. 1-2
Warnings & Cautions............................................................................................ 1-2
Disclaimers and Local Codes ................................................................................ 1-2
Installation 2-1
Product Overview................................................................................................. 2-2
Placement & Rigging........................................................................................... 2-3
Clearances and Serviceability .............................................................................. 2-4
Install BoilerTrim ................................................................................................. 2-6
InstallWater Piping.............................................................................................. 2-6
MeetWater Chemistry Requirements.................................................................. 2-9
PREVENT OXYGEN CONTAMINATION..........................................................................................29
ELIMINATE SYSTEM AIR ............................................................................................................210
Fill the BoilerWithWater ................................................................................... 2-10
Install Gas Piping................................................................................................ 2-10
COMPONENTS REQUIRINGVENTILATION TOTHE OUTDOORS.................................................213
Install Condensate Drain.................................................................................... 2-14
Install pH Neutralization Kit............................................................................... 2-15
Install Oil Piping................................................................................................. 2-15
OIL PIPING FOR DUAL FUEL BOILERSWITH THE RIELLO BURNER .......................................215
Hydraulic Connections ....................................................................................... 2-18
Oil Pump Priming .............................................................................................. 2-18
Oil Filtration........................................................................................................ 2-18
Venting............................................................................................................... 2-18
COMBUSTION AIR SUPPLY FROM THE BOILER ROOM..............................................................221
AIR PIPED FROM OUTSIDE BOILER ROOM................................................................................221
ExhaustVenting ................................................................................................. 2-22
COMMONVENTING LAYOUTS FORVANTAGE............................................................................222
VENTINGTERMINATIONS..........................................................................................................225
WALL THIMBLE INSTALLATION.................................................................................................226
HORIZONTALVENTTERMINATION............................................................................................227
Removing an Existing Boiler ............................................................................. 2-27
Electrical Connections ....................................................................................... 2-28
Assembly of Fulton Multi-Skid Systems............................................................. 2-28
Operation 3-1
Perform Pre-Start-Up Inspection......................................................................... 3-2
Fill and Purge the System..................................................................................... 3-2
CommissionThe Boiler......................................................................................... 3-3
SYSTEM DESIGN AND BOILER OPERATION.................................................................................33
Siemens LMV36 and LMV37 Control.................................................................... 3-4
OPERATING POINTS ONTHE SIEMENS LMV CONTROL...............................................................34
NORMAL OPERATION ..................................................................................................................34
INITIAL PROGRAMMING .............................................................................................................34
COMMISSIONINGTHE UNIT.........................................................................................................35
Siemens LMV51 Control....................................................................................... 3-6
OPERATING POINTS ONTHE SIEMENS LMV CONTROL...............................................................36
NORMAL OPERATION ..................................................................................................................36
PREIGNITION .............................................................................................................................36
SETTING PILOT FOR BOILERS EQUIPPEDWITH A PILOT..........................................................37
SETTING MAIN BURNER IGNITION..............................................................................................38
RESETTING THE ALARM...............................................................................................................38
SETTING MODULATION ...............................................................................................................39
SETTING LOW FIRE.......................................................................................................................39
SETTING THE COMPLETE TURNDOWN RANGE .........................................................................310
OperatingTemperatures and Fuel Selection...................................................... 3-11
Temperature Controller Instructions.................................................................. 3-11
SC500 TEMPERATURE CONTROLLER BASIC PROGRAMMING ................................................311
YOKOGAWA UT 32A BASIC PROGRAMMING: ...........................................................................312
SIEMENS RWF40 BASIC PROGRAMMING.................................................................................313
Access toVariable Speed Drive Blower Motor .................................................. 3-14
TEST OF IGNITION SAFETY SYSTEM..........................................................................................315
PerformTest of LowWater Cut O ..................................................................... 3-15
PerformTest of Limit Controls ........................................................................... 3-15
PerformTest of Low Gas Pressure Switch .......................................................... 3-16
PerformTest of High Gas Pressure Switch.......................................................... 3-16
General Operation of the Boiler ......................................................................... 3-16
Maintenance 4-1
General................................................................................................................. 4-2
Daily Maintenance and Inspection Schedule ...................................................... 4-2
Weekly Maintenance and Inspection Schedule .................................................. 4-2
Monthly Maintenance and Inspection Schedule................................................. 4-2
PROCEDURE FOR CLEANINGTHE AIR INLET FILTER LOW EMISSIONS BURNERS ..................43
Annual Maintenance and Inspection Schedule................................................... 4-3
ANNUAL REMOVAL AND INSPECTION OF LE BEKAERT BURNER...............................................44
Verication ofTorque Settings on Fireside Access Doors ..................................... 4-4
Inspecting/Cleaning the Flue Passages ............................................................... 4-7
BOILERS FIRING ON #2 OIL, B100 BIODIESEL, DIGESTER GASES OR ANY OTHER SUBSTANCE
BESIDES NATURAL GAS OR PROPANE.........................................................................................47
PROCEDURE FOR ACCESSING THE DUPLEX STAINLESS STEEL FLUE PASSAGES........................47
Replacing a Servomotor and Related Components............................................. 4-7
Ignition Pilot Adjustment - Dual Fuel Burners..................................................... 4-8
FOR UNITSWITH RIELLO RLS100130E BURNER......................................................................48
FOR UNITSWITH RIELLO RLS160E BURNER ............................................................................48
After All Repairs and Maintenance ...................................................................... 4-8
Troubleshooting................................................................................................... 4-8