Furukawa OFS Slimbox 24 User manual

OFS
Installation Instructions
for Slimbox 24 Fiber
Indoor Enclosure
8/3/2016
This document describes the assembly instructions for the SlimBox-V, Indoor Enclosure –24
fiber.

C16AK0009 REV.1 SLIMBOX-V, INDOOR ENCLOSURE-24F
ISSUE DATE 8/5/2016 pg. 1
Contents
Contents.................................................................... 1
1. Products .............................................................. 2
2. Wall Installation Instructions ........................................ 2
3. Installation Type “Fan-out” ........................................... 3
4. Installation Type “Splitter” .......................................... 6
5. Installation Type “Splice Tray” ...................................... 11
6. Installation Type “Direct” ........................................... 17
7. Technical assistance ................................................. 20

C16AK0009 REV.1 SLIMBOX-V, INDOOR ENCLOSURE-24F
ISSUE DATE 8/5/2016 pg. 2
1. Products
There are four basic types of configuration of the product.
1. Fan-out
2. Splitter
3. Splice Tray
4. Direct
Wall mounting technique is the same for all configurations. Each configuration will be described
under a separate paragraph.
2. Wall Installation Instructions
1. Start by opening the accessories package and find the wood screws M3.5 x 19 mm (4x),
wall anchors S5 (4x) and T18R plastic ties (10x) included in the installation kit.
2. Use the drill template to mark the location of the mounting holes for the enclosure.
3. Use a 3/16 inch (approx. 5mm) drill bit to drill ¾ inch (19mm) deep holes for the wall
anchors. Insert the wall anchors flush with the mounting surface. You can use #6 x3/4 in
long wood screws for direct mount on plywood. In this case, pre-drill holes using a 3/32
inch (2.4 mm) drill bit.
4. Secure the enclosure base to the wall using provided Pan Head Recess Cross M3.5-
19mm long screws. If you direct mount the base to the board without using wall anchors,
drill pilot holes at the marked locations using a 3/32 inch drill bit and then use #6 x ¾ in
long wood screws (not included in the mounting kit) for securing the base to the board..

C16AK0009 REV.1 SLIMBOX-V, INDOOR ENCLOSURE-24F
ISSUE DATE 8/5/2016 pg. 3
3. Installation Type “Fan-out”
Typical application of a fan-out consists of up to 24 fiber input cable conectorized with two
MPO 12 fiber female connectors and twenty four (24) 1.6-2mm single fiber distribution cables
connectorized with SC/UPC connectors.
Other configurations are available upon request.
1. Complete wall installation per paragraph 2 “Wall installation Instruction”
2. Unscrew two (2) screws and temporally remove the holding plate to loosen the plastic
retainers. Lay down incoming 1.6 or 2 mm diameter cables in the retainer’s grooves.
Assemble approximately six (6) cable assemblies per retainer. Start laying the cables
from the bottom retainer and work your way up to the top one. Don’t put the holding
plate on back yet
3. Plug the cable connectorized ends (SC/UPC) into the adapters. Match the adapter number
with the appropriate cable number. Adjust the cable “free” length before tightening the
cable retainers
4. Put the holding plate back and tight up the screws. The cables should not move if you
gently tug on the cable
5. Cut the rubber grommet following the molded in notch until you reach the center of the
molded hole. Slide a 3 mm cable of the MPO connectorized cable assembly through the
opening.
6. Connect the MPO end to the appropriate MPO adapter port labeled F1 or F2
7. Secure the cable to the retaining “L” bracket with a cable tie
8. Fill in the provided destination sheet and insert it into the document holder, located on the
inside wall of the cover
9. Assemble the cover to the base

C16AK0009 REV.1 SLIMBOX-V, INDOOR ENCLOSURE-24F
ISSUE DATE 8/5/2016 pg. 4
MPO to 12 Fiber
SC/UPC Fan-Out
(2X)
Base
Cable Anchor
"L" Brkt.
Adapter Mtg. Brkt.®
w/adapt.
Rubber
Grommet
Plastic Retainer
Holding Plate
Fig. 1 “Fan-out” style
assembly (installation kit
and cover are not shown)

C16AK0009 REV.1 SLIMBOX-V, INDOOR ENCLOSURE-24F
ISSUE DATE 8/5/2016 pg. 5
Fig.2 Typical installation of the “Fan-out” assembly

C16AK0009 REV.1 SLIMBOX-V, INDOOR ENCLOSURE-24F
ISSUE DATE 8/5/2016 pg. 6
Fig. 3 Components of the “Fan-out” type enclosure
4. Installation Type “Splitter”
Typical application consists of 4 fiber input cable conectorized with SC/APC connectors, up to
four (4) PLC 1:32 splitters and up to 128 fiber distribution cable or cables connectorized with
and 16 MPO Female 8 Fiber connectors. Other splitter and connector configuration are available
upon request.
Cover
Cover, back view
Assy Top view
Exploded view of the assembly
(fan-outs not shown)

C16AK0009 REV.1 SLIMBOX-V, INDOOR ENCLOSURE-24F
ISSUE DATE 8/5/2016 pg. 7
Instructions
1. Open the closure and examine its content. Ref to Fig.3 and Fig. 5. All assemblies will
contain :
a. Fiber organizer spool
b. Three rubber grommets with tree cable retainers (“L” shape brkt. with rectangular
holes to pass plastic ties)
c. Metal adapter bracket with SC and adapters
d. One up to four (order dependent) ruggedized splitter housings each containing
one 1:32 PLC splitter. The splitter input fiber is connectorized with a SC/APC
connector. The output four-ribbon cables are connectorized with MPO female
connectors. The connectors are inserted into corresponding ports.
e. Two pivoting Splice trays are provided to hold splice protectors.
f. Cover
g. Mounting kit
Fig. 4 Enclosure type “Splitter”
(As received excluding installation kit)

C16AK0009 REV.1 SLIMBOX-V, INDOOR ENCLOSURE-24F
ISSUE DATE 8/5/2016 pg. 8
2. Follow the enclosure installation steps from the paragraph entitled “Wall installation
instructions (paragraph 2)
3. Cut the middle entry port rubber grommet following the molded in notch until you reach
the center of the molded hole. Thread drop cable through the he just created opening. Use
the cable aramid yarn, “L”bracket and cable ties to restrain the cable.
4. Splice provided SC/APC 900 µm pigtails with the drop cable fibers. Store the splice
protectors in the pivoting splice trays. Use the slack management spool and the splice trays
to manage fiber extra length.
5. Plug the spliced pigtail SC/APC ends into designated SC/APC adapters located in the
adapter bracket to mate with the splitter input fiber.
6. Use left and right entry port for drop cables installation. Choose the grommet hole to
match the cable size. Cut the rubber grommet following the molded in notch until you
reach the center of the molded hole. Thread the MPO connectorized drop cable through
the just created opening.
7. Attach the aramid yarn to the retaining” L” bracket with the provided plastic ties.
8. Record the connection information on the destination sheet and insert the sheet into the
document holder located on the inside wall of the cover
9. Assemble the cover to the base

C16AK0009 REV.1 SLIMBOX-V, INDOOR ENCLOSURE-24F
ISSUE DATE 8/5/2016 pg. 9
Adapter
bracket
Splitter
Fig. 5 Enclosure Type
“Splitter”
Splice tray
Entry/Exit
Port (3X)

C16AK0009 REV.1 SLIMBOX-V, INDOOR ENCLOSURE-24F
ISSUE DATE 8/5/2016 pg. 10
Fig.6 “Direct” style enclosure- typical installation
Note:
White multi-fiber drop outdoor –indoor cable is spliced to the optical splitter (s) input fiber(s)
and the splitter(s) outputs are spliced to the distribution cable(s). In Figure 6, the distribution
cables are yellow.

C16AK0009 REV.1 SLIMBOX-V, INDOOR ENCLOSURE-24F
ISSUE DATE 8/5/2016 pg. 11
Cover
Cover, back view
Assy Top view
Exploded view of the assembly
(fan-outs not shown)
Fig. 7 Components- Enclosure type “Splitter”
5. Installation Type “Splice Tray”
This type of installation provides ten splice trays. Each splice tray can accommodate 12
splice protectors or splitters. No optical connector or adapters are used.
Drop and drop cables are secured using either aramid yarn or/and the cable strain relief
member tied to anchor bracket located at the upper sections of the enclosure. If needed, the
bracket can be easily field relocated to the lower section of the enclosure.

C16AK0009 REV.1 SLIMBOX-V, INDOOR ENCLOSURE-24F
ISSUE DATE 8/5/2016 pg. 12
Instructions
1. Open the enclosure and examine its content. Refer to Fig. 6. All assemblies will
contain:
a. Fiber organizer
b. Three rubber grommets with tree cable retainers (“L” shape brkt. with
rectangular holes to pass plastic ties)
c. Ten (10) pivoting Splice trays to hold splice protectors (note: the splice trays
come in two colors: gray and black)
d. Two anchor bracket
e. Mounting kit
f. Cover
Anchor nut
Anchor
Brkt.
Fig. 8 Enclosure type “Splice”
w/o cover and installation
kit

C16AK0009 REV.1 SLIMBOX-V, INDOOR ENCLOSURE-24F
ISSUE DATE 8/5/2016 pg. 13
2. Follow the enclosure installation steps from the paragraph entitled “Wall installation
instructions (paragraph 2)
3. Cut an entry port rubber grommet following the molded in notch until you reach the
center of the molded hole. Thread drop cable through the he just created opening. Use
the cable aramid yarn, “L”bracket and cable ties to restrain the cable. If you use a cable
with a strength member, use the anchor brkt. to restrain the cable. You may move the
anchor bracket. to lower part of the enclosure base to comply with your installation
requirements
4. Store splice protectors and cable slack in the splice trays. If you use splitters, store them
in the splice trays as well.
5. Record the connection information on the destination sheet and insert the sheet into the
document holder located on the inside wall of the cover
6. Assemble the cover to the base

C16AK0009 REV.1 SLIMBOX-V, INDOOR ENCLOSURE-24F
ISSUE DATE 8/5/2016 pg. 14
Fig. 9 Securing cable to “L” bracket – enclosure type “Splice”
Aramid yarn
attached to
"L" brkt.

C16AK0009 REV.1 SLIMBOX-V, INDOOR ENCLOSURE-24F
ISSUE DATE 8/5/2016 pg. 15
Fig. 10 Typical “Splice” style installation
Note:
There are ten splice trays each capable of holding six splitters or twelve splice protectors.
Usually, first two trays contain splitters and splice protectors and the remaining eight hold only
splice protectors. The splices are made between splitter inputs and the drop cable (white) and the
splitter outputs fibers and distribution cables(s).
Distribution cable
Splice
protector
Drop cable
Splitter

C16AK0009 REV.1 SLIMBOX-V, INDOOR ENCLOSURE-24F
ISSUE DATE 8/5/2016 pg. 16
Cover
Cover, back view
Assy Top view
Exploded view of the assembly
Fig. 11 Components –Enclosure type “Splice” w/o mounting kit

C16AK0009 REV.1 SLIMBOX-V, INDOOR ENCLOSURE-24F
ISSUE DATE 8/5/2016 pg. 17
6. Installation Type “Direct”
This type of installation uses 12 or 24 fiber cables or multiple of them to the total of 48
connectorized ends. The acceptable cable sizes are up to 15 mm (0.6 in). The cables are either
connectorized with SCA, SCU, LCA or LCU connector or not. In the case of using not
connectorized cable, use pigtails to splice them onto the cable. Match the connector plug type
with the adapter type of the adapter bracket.
The 24 position adapter bracket comes populated with the adapters which match the type of
connector the drop cable is terminated with. Alternatively, if a un-connectorized cable is used,
pigtails can be spliced to the cable and the splice protectors along with the cable slack stored in
the provided pivoting splice trays.
The distribution cables, each in the range 1.6 -2mm in diameter, leave the enclosure through the
port having 5 plastic retainers. It is important to not use the cables having diameter outside of the
1.6-2.0 mm range since it may result in the cable damage and high optical losses or not sufficient
retention if smaller size cable is used. The port equipped with plastic retainers can accommodate
40 of 1.6-2.0mm cables. If you have more cable leaving the enclosure, use unused ports of two
rubber grommets.
Installation steps
1. Open the package and examine the content. You should receive:
a. Base with oval fiber organizer
b. Two pivoting splice tray
c. Adapter bracket with appropriate type of adapters
d. Two ports with rubber grommets and “L” mounting brackets
e. One port with five plastic retainers and securing “L” bracket
f. Cover with destination sheet
g. Mounting template
h. Installation kit
2. Complete wall installation per paragraph 2 “Wall installation Instruction”
3. Bring the drop cable through one of the rubber grommet port. For this purpose, cut the
rubber grommet following the mold-in cut line until you reach the center of the mold-in

C16AK0009 REV.1 SLIMBOX-V, INDOOR ENCLOSURE-24F
ISSUE DATE 8/5/2016 pg. 18
hole. Slide the cable trough just made opening and replace the grommet. Tie the cable
aramid yarn to the “L” bracket with a plastic tie. If the cable has a strength member, tie it
to the one of the anchor bracket located at the top left and right of the base
4. Plug the cable connectorized ends into the designed adapter ports. If you use un-
connectorized cable, splice the pigtails and store the splice protector and extra cable
length in the splice trays. Plug the cable connectorized ends into the designed adapter
ports.
5. Unscrew two (2) screws and temporally remove the holding plate to loosen up the plastic
retainers. Lay down distribution 1.6 to 2 mm diameter cables in the retainer’s grooves.
Assemble approximately six (6) cable assemblies per retainer. Start laying the cables
from the bottom retainer and work your way up to the top one. Don’t put the holding
plate on back yet
6. Plug the cable connectorized ends into the adapters. Match the adapter number with the
appropriate cable number. Adjust the cable “free” length before tightening the cable
retainers.
7. Put the holding plate back and tight up the screws. The cables should not move if you
gently tug on the cable.
8. Secure the cable to the retaining “L” bracket with a cable tie
9. Fill in the provided destination sheet and insert it into the document holder, located on the
inside wall of the cover
10. Assemble the cover to the base

C16AK0009 REV.1 SLIMBOX-V, INDOOR ENCLOSURE-24F
ISSUE DATE 8/5/2016 pg. 19
Fig. 12 Enclosure Installation type “Direct”
(w/o cover and mounting kit)
Strain
member
anchor
brkt
Adapter plate
with adapters
Splice Tray
Fiber
organizer
Plastic
Retainer
Rubber Grommet
“L” Brkt
This manual suits for next models
2
Table of contents
Other Furukawa Enclosure manuals
Popular Enclosure manuals by other brands

Watts
Watts HIU2VSA-2 Installation and operating manual

Thecus
Thecus Thecus N199 Quick installation guide

Geeek
Geeek A40 V3 installation guide

Safe-t-Cover
Safe-t-Cover HCF600DS Series Assembly instructions

StarTech.com
StarTech.com 4POSTRACK36 instruction manual

RIHO
RIHO HAMAR 2.0 R207 Square installation manual