Introduction: Safety nformation
Page 1 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSL BE - Lift System Light Box Enclosure
Warnings:
1. Read all technical instructions fully before installation and use. It is the installer’s responsibility to ensure that all
documentation is passed on the end user and read fully before operation.
2. Keep all documentation.
3. Heed all warnings.
4. Follow all technical specifications and instructions during installation.
5. Do not use near water unless the product has been specifically designed to do so.
6. Clean only with a dry cloth.
7. Do not defeat the purpose of the polarized or grounding type plug. A polarized plug has two blades, one wider
than the other. A grounding type plug has two blades and a grounding prong. The wide blade or third prong are
provided for your safety. If the provided plug does not fit your outlet, consult an electrician or contact the
manufacturer.
8. Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the
point where the exit from the apparatus.
9. Unplug the apparatus during lightning storms or when unused for long periods of time.
10. Only use attachments/accessories specified by the manufacturer.
11. Refer all servicing to qualified personnel. Servicing is required regularly on an annual basis, when the apparatus is
damaged in any way, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been
exposed to rain or moisture, does not operate normally, or has been dropped.
12. To completely disconnect the apparatus form the AC mains, disconnect the power cord plug from the AC
receptacle on the power control box.
13. To prevent overheating, do not cover the apparatus. Install in accordance with the instructions.
14. UK, Ireland and Hong Kong only – The power cord is supplied with a 13A plug having an earthing pin. The
apparatus is earthed and this pin is not required for safety, merely to operate the safety shutter of mains outlet.
15. No naked flames such as lit candles should be placed on the unit.
16. Observe and follow the local regulations when disposing of batteries.
17. Do not expose the unit to dripping or splashing fluids.
18. Do not place objects filled with liquid, such as vases, on the unit.
19. Do not expose the batteries to excessive heat such as sunshine, fire or the like.
20. For all mounted apparatus, the apparatus should be installed on solid wood, bricks, concrete or solid wood
columns and battens.
21. Always turn off power at source before putting on or taking off parts and cleaning.
22. Do not use outdoors unless marked for outdoor use.
23. Exceeding the weight capacity can result in serious personal injury or damage to equipment.
Future Sound & Vision trading as Future Automation intend to make this and all documentation as accurate as possible. However, Future
Automation makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every
possible contingency in connection with the installation or use of this product. The information contained in this document is subject to
change without prior notice or obligation of any kind. Future Automation makes no representation of warranty, expressed or implied,
regarding the information contained herein. Future Automation assumes no responsibility for accuracy, completeness or sufficiency of the
information contained in this document.
Safety Disclaimer
mportant Safety nstructions
Explanation of graphical symbols
-(Electric Shock Symbol) = The lightning flash within an equilateral triangle is intended to alert you to the presence of un-insulated
“dangerous voltage” within the products enclosure that may be of sufficient magnitude to constitute an electric shock to persons
-(Caution Symbol) = The exclamation point within an equilateral triangle is intended to alert you to the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the product
-(Tools Symbols) = The tools symbol within a coloured square are intended to highlight the required tools necessary for correct and
safe installation of the product. These are intended as a
guide only, and it is at the installer’s discretion as to which tools are used.
WARNING: R SK OF ELECTR C SHOCK, ONLY AUTHOR ZED NSTALLERS TO OPEN THE POWER CONTROL BOX.
WARNING: To reduce the risk of fire or electric shock, do not expose electrical parts to rain or moisture, unless the
product has been specifically designed to do so.
WARNING: Failure to provide adequate structural strengthening, prior to installation can result in serious personal injury or damage to the
equipment. t is the installer’s responsibility to ensure the structure to which the component is affixed can support the four times the
weight of the component.
WARNING: Do not exceed the weight capacity. This can result in serious personal injury or damage to the equipment. t is the installer’s
responsibility to ensure that the total combined weight of all attached components does not exceed that of the maximum figure stated.
WARNING: Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equip-
ment! t is the installer’s responsibility to make sure the structure to which this component is attached can support five times the combined
weight of all equipment. Reinforce the structure as required before installing the component.
Caution
Warning
Beware of
Moving Parts
Keep Hands
Clear
Danger
Electricity

Introduction: Contents
Page 2 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSL BE - Lift System Light Box Enclosure
Contents Page
ntroduction
Safety nformation 1
Contents 2
Contents 3
Tool ndicator cons 3
nstallation
Parts List
Package Contents 4
Stage 1
Before You Start 5
Remove KH Screen Mount 5
Stage 2
Fixing the Lift in the Cabinet 6
Stage 3
KH Upright Assembly 7
Stage 4
Mounting the Box Enclosure 8
Stage 5
Attaching the Enclosure 9
Stage 6
Routing the Cables & Screen Mount Plate Fixings 10
Stage 7
Screen & Box Enclosure Mounting 11
Stage 8
Switch Adjustments 12
Electrical Connections
Contact Closure 13
RS232 Controls 14
R Controls 15
Operations
R Control & Operation 15
Storing Positions 15
Changing Batteries 15
Trouble Shooting 16
Technical Overview 17
Notes 18

Introduction: Contents / Tool ndicator
Page 3 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSL BE - Lift System Light Box Enclosure
Tool Indicator Icons
1. 2. 3. 4. 5. 6.
1. - Drill 3. - Allen Keys 5. - Screwdrivers 7. - Pencil
2. - Tape measure 4. - Spirit Level 6. - Spanners 8. - Saw
7. 8.
Product Warranty
This product carries a warranty that covers the cost of labour and spare parts incurred by any defects in materials and workmanship under normal use
during a two year period from date of purchase. Support for any problems that are not hardware faults are excluded from the warranty entitlement.
This warranty does not affect your statutory consumer rights.
The following is excluded from warranty service:
• Malfunctioning caused by misuse or damage, accidental or otherwise, or service modification by persons not authorised by Future Automation,
or the use of any non Future Automation supplied parts;
• Any electrical, or other environmental work external to your Future Automation mechanism including power cuts, surges or lightning strikes;
• Additional items not supplied by Future Automation although they may have been supplied together by the retailer;
• Any 3rd party software products controlling your mechanism;
• Any transfer of ownership. Warranty is provided only to the initial purchaser;
• Compensation for loss of use of the product, and consequential loss of any kind;
• Use of the product over the specified weight capacity;
• Any damage to products during transit that is not checked and notified as “unchecked” or “damaged” upon receipt of delivery.
Any part of your system that needs to be replaced during a warranty repair becomes the property of Future Automation.
Contents Page

Installation: Parts List
Page 4 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSL BE - Lift System Light Box Enclosure
1.2
3
1.4
Nuts & Bolts ultipack:
A range of nuts, bolts, washers
and spacers to help add in the
mounting for your screen
Package Contents
1 - Mechanism
1.1 - Back Plate
1.2 - Lifting Drive
1.3 - Base Panel Brackets
1.4 - KH Lifting Plate
1.5 - Screen Mount
1.6 - Cable Management
1.7 - Lid Mount Bracket
1.8 - Adjustable N/OUT Switch
2 - Control Box
3 - Remote Control
Not Shown On Page
4 - x2 AAA Batteries
5 - Multi Pack Of Nuts,
Bolts & Washers
6 - Mains Power & Other
Leads
2
1
1.1
1.5
1.7
1.6
1.7
1.3
1.3
1.8
1.8

Installation: Stage 1
Page 5 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSL BE - Lift System Light Box Enclosure
Before You Start
Check the Operation of the Mechanism.
Firstly, remove all the red cable ties which keep the mechanism safe and secure during
transit.
Once they have all been removed, the mechanism can be powered up and tested.
Connect the supplied R lead and check that the mechanism operates correctly before
continuing with the installation.
KH LOCK NG
LEVER
L D MOUNT
BRACKET
Remove KH Screen ount
Un-lock the KH mount plate but turning the locking lever 90 dgrees and lift off the
hook toggles.
KH MOUNT PLATE
KH HOOK
TOGGLES

Installation: Stage 2
Page 6 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSL BE - Lift System Light Box Enclosure
Fixing the Lift in the Cabinet
Place the mechanism within the cabinet. Fix the lift where possible down the back face.
Make sure that the lifting plate is central by using the centre line marks on the back of
the back face.
CENTRE
MARKS

Installation: Stage 3
Page 7 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSL BE - Lift System Light Box Enclosure
KH Upright Assembly
Below shows the KH UPR GHT assembly. To release the SCREEN MOUNT PLATE rotate
the top LOCK NG LEVER and lift off the TOGGLES. The TOGGLES can adjust the height by
moving up or down the KH UPR GHT. The ENCLOSURE MOUNT BRACKETS fix to the side
of the KH UPR GHT and slide up and down to support the enclosure lid.
SCREEN
MOUNT PLATE
LOCK NG LEVER
TOGGLES
KH UPR GHT
ENCLOSURE
MOUNT BRACKET

Installation: Stage 4
Page 8 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSL BE - Lift System Light Box Enclosure
ounting the Box Enclosure
After the mechanism is in the correct position the next step is to lower the BOX
ENCLOSURE into place and fix from the underside through the BASE PANEL
BRACKETS. A good tip is to place the BOX ENCLOSURE in place and draw
marks from the underside through the BASE PANEL BRACKETS, then fix using a
wood screw and a large penny washer, this will allow you to adjust the position.
BOX ENCLOSURE
BASE PANEL
BRACKETS
Page 12
Stage 8 - Details
on adjusting the
OUT position
ENCLOSURE L D
BRACKETS
BASE
ENCLOSURE

Installation: Stage 5
Page 9 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSL BE - Lift System Light Box Enclosure
Attaching the Enclosure
With the mechanism still in the UP position fix the base panel to the BASE PANEL
BRACKETS, adjust the height so the base panel sits flush to the cabinet top. Then
adjust the ENCLOSURE L D BRACKETS to the correct height to support the cabinet
lid and enclosure.
ENCLOSURE
BASE F X NG
ENCLOSURE
L D F X NG

Installation: Stage 6
Page 10 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSL BE - Lift System Light Box Enclosure
Hook the SCREEN MOUNT
PLATE on to the KH UPR GHT
over the TOGGLES and secure
using the LOCK NG LEVER.
SCREEN
MOUNT
PLATE
KH MOUNT
UPR GHT
Routing Cables & Screen ount Plate Fixing
Once the ENCLOSURE is fixed to
the mechanism thread the screen
and power cables through the
cable management chain and
then through the lifting beam
shown with the orange dotted line.

Installation: Stage 7
Page 11 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSL BE - Lift System Light Box Enclosure
Screen & Box Enclosure ounting
Finally offer the box enclosure back panel
and fix to the sides. This back panel needs
to be removable to take the screen off.
Slide the screen into the
enclosure and fix to the
SCREEN MOUNT PLATE.
A good tip is to use a
packer under the screen
and remove once fixed and
secure.

You can adjust the N and OUT position of the lifting beam. Detail 1shows how
to adjust the OUT position and detail 2shows how to adjust the N position.
The R sensor can be located anywhere outside of the cabinet.
Switch Adjustments
Installation: Stage 8
Page 12 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSL BE - Lift System Light Box Enclosure
1
2
1- The top switch can’t be
adjusted when the mechanism
is in the OUT position, because
the switch is active. Lower the
mechanism and press STOP
after about 100mm [4”]. Then
adjust the OUT switch plate by
loosening the bolts and sliding
the plate.
2- Bottom switch can be adjusted
by repeating the first procedure.

Installation: Electrical Connection
Page 13 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSL BE - Lift System Light Box Enclosure
SLQV
Contact Closure
- Use an RJ45 connector in the CC
socket on the control box to operate
via contact closure
LED 1
LED 2
LED 3
LED 4
LED 5
CONTACT CLOSURE NPUT
NOTE:
Earlier versions of the control board
may not have these contact closure
LED indicators.
568A 568B
1 12V SUPPLY 12V SUPPLY - CURRENT LIMITED W/G W/O
2 12V LATCH When 12V attached, device will go OUT. When
12V removed, device will go IN. GO
3GROUND GROUND W/OW/G
4 PIN 4 NOT USED BL BL
5 DEVICE LATCH Short to GROUND (pin 3), device will go OUT,
remove short device will go IN. W/BL W/BL LED 4
6 DEVICE STOP Momentary short to GROUND (pin 3), stops
device in current position. O G LED 3
7 DEVICE OUT Momentary short to GROUND (pin 3), makes
device go OUT. W/BR W/BR LED 2
8 DEVICE IN Momentary short to GROUND (pin 3), makes
device go IN. BR BR LED 1
PIN DESCRIPTION ACTION WIRE / CABLE CONTACT CLOSURE
LED INDICATOR

Installation: RS232 Control
Page 14 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSL BE - Lift System Light Box Enclosure
Connection Locations
ains Voltage Input
IR LED
IR Input Jack
RS232
Contact Closure
SLQV
RS232
- Use an RJ25 connector
in the socket marked
RS232 on the control box
to operate using RS232
Details
Baud rate: 9600
Stop bit: 1
Parity: None
Databits: 8
Pin 1: RX
Pin 6 : TX
Pin 3 & 4: GROUND Pin 2: TX
Pin 3: RX
Pin 5: GROUND
I PORTANT
Ensure protocol is entered exactly
as written, including Carriage Return
(Enter / ASC 13).
RJ25 9 PIN D
P N 1: RX TO P N 2: TX
P N 6: TX TO P N 3: RX
P N 3: GROUND TO P N 5: GROUND
P N 4: GROUND TO P N 5: GROUND
Protocol Action
fa_in Carriage Return (Enter ) Device N
fa_out Carriage Return (Enter ) Device OUT
fa_stop Carriage Return (Enter ) Device STOP (At any position)
Emergency Stop Connector

Installation: R Control
Page 15 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSL BE - Lift System Light Box Enclosure
Future Automation R
Remote Controller
needs x2 AAA batteries
which are provided
within the packaging
Replacing batteries
Out - Brings the
mechanism out of the
cabinet facing forward
In - Brings the mechanism
inside the cabinet
Stop - Will stop
the operation at
any position
Operation buttons for the IR remote
Note
Only buttons indicated are
functional with the product. Any
button pressed when in motion
will stop the mechanism.

Trouble Shooting:
Page 16 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSL BE - Lift System Light Box Enclosure
Lift System Light Box Enclosure - Trouble shooting guide
Lift System Light Box Enclosure - Trouble shooting
For information on our products please refer to our web site -
www.futureautomation.co.uk
or for questions on installations and our product range please
phone us on - +44(0) 1438 833577 and ask for our technical
support department

Technical Overview:
Page 17 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSL BE - Lift System Light Box Enclosure
Technical Overview
A general technical overview of the LSL BE lift mechanism range
Product Size Range LSL BE 1 LSL BE 2 LSL BE 3
Width - 394mm [15.5"] Width - 394mm [15.5"] Width - 394mm [15.5"]
Height - 580mm [22.8"] Height - 694mm [27.3"] Height - 769mm [30.3"]
Depth - 117mm [4.6] Depth - 117mm [4.6] Depth - 117mm [4.6]
Weight Approx 15Kg [33.0lb] 17Kg [37.5lb] 19Kg [41.9lb]
Power Consumption 250W - 500W 250W - 500W 250W - 500W
Power Consumption
On Standby
100mA 100mA 100mA
Lifting Capacity 25Kg [55lb] 25Kg [55lb] 25Kg [55lb]
Lifting Capacity Marine 16Kg [35lb] 16Kg [35lb] 16Kg [35lb]
Standard Screen Mount
Colour
Black Black Black
Max Television Size Height - 410mm [16.1"] Height - 524mm [20.6"] Height - 599mm [23.6"]
Control
IR Remote, RF Remote,
Contact Closure & RS232
IR Remote, RF Remote,
Contact Closure & RS232
IR Remote, RF Remote,
Contact Closure & RS232
Power Supply 240V or 110V 240V or 110V 240V or 110V
Control Of 3rd Party Product Yes Yes Yes
Output Power Supply Yes (12V) Yes (12V) Yes (12V)
Control Box Size (W,D,H)
150x210x52mm
[5.9x8.3x2.0"]
150x210x52mm
[5.9x8.3x2.0"]
150x210x52mm
[5.9x8.3x2.0"]
Shipping Details
Dimensions Approx (W,D,H)
Weight Approx 20Kg [44.1lb] 22Kg [48.5lb] 24Kg [52.9lb]
LSL BE RANGE
Product Dimensions
600x300x1000mm
[23.6x11.8x39.4"]
600x300x1000mm
[23.6x11.8x39.4"]
600x300x1000mm
[23.6x11.8x39.4"]

Page 18 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
LSL BE - Lift System Light Box Enclosure
Notes...

Future Automation
Unit 2 Kimpton Enterprise Park
Claggy Road
Kimpton
Hertfordshire
SG4 8HP
United Kingdom
Tel: +44 (0) 1438 833 577
Fax: +44 (0) 1438 833 565
Email: [email protected]
www.futureautomation.co.uk
This manual suits for next models
3
Table of contents
Other Future Automation Enclosure manuals