HDD-8RB HEAVY DUTY CYLINDER DRIER
INSTRUCTION MANUAL
~•I
GALISO
®
INCORPORATED
MAILING: P.O. BOX 1466 _MONTROSE. CO 61402
SHIPPING; 22 PONDEROSA COURT
MONTROSE. CO 81401
303)
.
249-0233
(6OO) 854-3789
TELEX: 6106018738
FAX 303-249-0607
FORM NO. GS08201-2
ISSUE DATE: 12/30/87
SUPERSEDES: 12/83

TABLE OF CONTENTS
PART TITLE
PAGE
1
Introduction 1
la
Specifications
2
2
Safety
.....................................................................................
3
3
Installation
4
4
Operation
5
5
Maintenance
.....................................................................................
6
PART TITLE
ILLUSTRATIONS
PAGE
1
HDD-8RB Heavy Duty Cylinder Drier
2
Copyright 1987, Galiso, Incorporated, Anaheim, California
Editor: Scott Mitchell
Production: Kelly Cuskelly
"Galiso", "Hydraclose", and 'Turnair" are registered trademarks of Galls°, Incorporated.

PART 1 INTRODUCTION
The Galiso HDD-8RB Heavy Duty Cylinder Drier is a hot air manifold type drier
designed to dry up to eight drained 9" by 51" cylinders in approximately 25 minutes.
The HDD-8RB Cylinder Drier features a thermostat controlled
8KW heating
element
and a 1.5 HP (1125 Watt) brushless regenerative blower motor which moves hot air
through cylinders at 106 cubic feet per minute. The brushless motor provides quiet,
maintenance free operation without the need to periodically replace worn brushes.
The blower assembly features a convenient 110 Volt electrical outlet, which is ideal
for operation of a cylinder inspection light.
The HDD-8RB Cylinder Drier includes "Quick Connect" drier tubes to speed the
process of loading and unloading cylinders. "Quick Connect" drier tubes easily snap
on or off, even when they are hot from the drying process. The first three drier tubes
have no checks to assure minimum air flow through the heater.
The HDD-8RB series drier is available for 220 Volt single phase, 220 Volt three
phase, or 440 Volt three phase operation to adapt to the power supply at your
facility. HDD driers are thermally insulated to assure maximum heating efficiency. All
cylinder driers are shipped partially disassembled with complete assembly and set-
up instructions provided.
In addition to the HDD series cylinder driers, Galiso also offers Medium Duty
Cylinder Driers (MDD) and Light Duty Cylinder Driers (LDD).
vcn
:
MOV$9$3Evom
1

CYLINDERS
I
NOT INCLUDED)
"QUICK- CONNECT" DRIER TUBES
S4
,3
PART
la SPECIFICATIONS
FIGURE 1) HDD-8RB HEAVY DUTY CYLINDER DRIER
SPECIFICATIONS
Power Requirements: 220 Volt,
single phase, 60 Hz.
220 Volt,
three phase, 60 Hz.
440
Volt, three phase,
60 Hz.
Blower Motor:
1.5 HP, 1125 Watt, Brushless, 106 cu. ft. per minute.
Heater Element:
8 KW, Thermostat controlled
Dimensions:
Height: 6 ft. 6 in. Length:
10
ft. 2 in. Width: 18 in.
Drier Tubes:
One half in. O.D. by 0.025 in. wall, "Quick Connect"
Warranty:
One year (see Galiso Warranty Terms, Form No. GS07805-1).
fefit
MA.***Sh,3%;%ti
(4:2R4V.

PART 2 SAFETY
1.
Read all instructions before attempting to install or operate the HDD-EMB Heavy
Duty Cylinder Drier. GALISO, INC. CANNOT BE RESPONSIBLE FOR DAMAGE
OR INJURY CAUSED BY UNSAFE USE, MAINTENANCE, OR APPLICATION
OF THIS MACHINE. Please contact Galiso for guidance when
you are in doubt
as to the proper safety precautions to be taken when Installing or operating this
machine.
2.
Take care to keep the work area around the HOD-8RB clean, dry and free of
debris. This will decrease the chance of operator injury due to slips or falls.
3.
The
HDD-8RB
drier is capable of producing considerable heat. Use insulating
gloves to protect hands against possible burns from
hot parts. Operator should
also wear eye, ear and foot protection when operating the HDD-SRB.
4.
Do not cover motor fan cowl, or drop screwdrivers, nails, etc., into openings of
fan cowl.
5.
Make sure the HDD-8RB is bolted securely to the floor.
1MAY1
MtkIRIARIZ.
.••••
.
.
. • . • .
•
.
.. .
.
.
.
. • . • .

PART 3 INSTALLATION
1.
Read all instructions and familiarize yourself with the installation blueprints
before attempting to install or operate the HDD-8RB Cylinder Drier.
2.
Carefully uncrate the HDD-8RB Cylinder Drier and remove all packing materials.
3.
To facilitate assembly, lift upper body to install the three legs. Lower to the floor.
4.
Bolt the motor to the leg brackets and assemble the muffler.
5.
Take cover off the thermostat control box. Fasten conduit elbow to the control
box and connect lead wires to the magnetic starter, per schematic in the back
of this manual.
6. Position the drier in its permanent place and bolt to the floor.
7.
Connect to the power supply and test for proper direction of motor rotation by
checking for air exhaust at the manifold outlets.
8.
Close the control box cover.

PA!! 4) OPERA
TION..
1.
Set the thermostat at the desired temperature and switch the HDD-8RB on. Let
it
warm up while draining cylinders completely of water.
2. Insert the blower tube into the cylinder.
3.
Bring the cylinder into position below a manifold outlet. Connect the blower tube
by pushing up into the
quick connector.
CAUTION:
Avoid bending the tube or
otherwise damaging the tube or connector.
4.
After cylinders have been drying for about 25 minutes, check each cylinder for
dryness and hook up the next cylinder.
5.
The first three positions are always open to insure minimum of air flow. Use
these positions first when drying cylinders.
6.
To shut down at the end of the day, turn the thermostat to "OFF". Let the motor
run for an additional 15 minutes to cool the unit down.

PART MAINTENANCE
No regular maintenance is required except to check the air filter on top of the muffler
at least once a month. Replace if necessary.
FORM NO. GS08201-2
ISSUE DATE: 12/30/87
SUPERSEDES: 12/83

SHEET
DATE
1 OF 1
25-93-3089
DESC.
REDRAWN AUDIT #10288
oRAHavc maw:
OIMM.•■■1.1
1••••■•
■
HEATER ELEMENT
ASSEMBLY
25-44-31034
If-
OFF
SW
7-
11-000
MAGNETIC
STARTER
89-11-3001
HEA TERS
FH- ..33
89-11-5503
TRANSFORMER
93-11-0001
THERMOSTAT
PILOT UGH T
85-11-0501
T3
I.1
POWER
L2
I
L3 1N
ERMOS I A T
9-11-0004
RESET
SWITCH
'vX1011311•2"--
.E
T
PUS& 10 AMP
88-11-0051
Mt
Molm
■
■•••■
■■■•
CONNECTIONS
FOR BLOWER
MOTOR
A
MATERIAL
ELECTRICAL SCHEMATIC 220 V 30
THIS DOCUMENT CONTAVIS
1-1
0D-8RD-220-30
PROPRIETARY
"FORMATION
WIN ALL
RIGHTS AND
TITLES
DRANING NUMBER
NEXT ASSEMBL
Y
SHEET
ftEstviv
RESERVED
RID
MAY NOT DE
25-9.3-3089
N/A
1 OF 1
A
REPRODUCED IN NHOLE CR IN
PART nunour RTE ARMEN
iliSCESS
OTHERMSE
SF'ECtflat -
TOIERANCES
ARE
EaN
CONSENT OF CALM, INC.
X = 1
.
XX
.
XXX
()OAS
V
L.IOU
IDS
SCUDS
NOTES:
1.
— 14 GA. BLACK. P/N 91-11-0067;
=
14
GA. WHITE, P/N 91-11-0068;
DIPEOST
2.
CONNECT GROUND WIRES TO GREEN TERMINAL AT
am-mu
OF CASE.
CHECK ROTATION OF BLOWER MOTOR; TO REVERSE
ROTATION, SWITCH LEADS TI & T3,
4. UNIT DRAWS 256 AMPS.
DRAM
Q.A
TEAM EDR
S.BROWN
DATE
11/7/97
DATE
DATE
SCALE
j
ar NAME
NCWF
25q37nRo

HEATERS
FH-
89-17-550..3
i
1TRANSFORMER
93-
11-0001
MAGNETIC
STARTER
89-11-3001
TrIERMOSTA
T
P
g
_OT LIGHT
85-11-0501
I/
T2 T3
MAGNETIC
CONTACTOR
89-11-3002
RISE, 6A
88-114035
T
....
1
■■•
EM .M
•
■■•
m. m.
m,■,■,.
mg
m. ommym■gm ..
am
mmmmy■.
ma ■
MM
w. .... WM M•MMIMM•M •M• •M MIM.ii
■ M.
■
POWER
ON
PILOT LIGHT
85-11-0501
HEATER ELEMENT
ASSFIV%
Y
25-44-3103A
MN
ERMOSTAT
9-T1-000
RESET
SW:
TCH
OU -TLE
32 11 UZI
•
•
■••••.M.
MWMIMM
M. SEMEMMM nin
MN
.
11
■11=1.1M•
MME,■•••1
FUSE.
10 AMP
11.
— CONNECTIONS
83-17-0051
FOR BLOWER
MOTOR
POWER
iI
II
IN
i
Ll
L2
L3
:
NEVE104
r
•
Er...N
I
SCALE
FitE NAVE
I CNA
eANG
Numevi■
25-93-3089
REV
1
DESC.
j
REORA li
f
N
AUDI
T
#10288
NOTES:
—
14
GA. BLACK, P/N
91-11-0067;
—
4 GA.
WrI1
TE. FIN
51
-11 -0068;
0616104-
1
OF
1
Ira rE
BY:
I
APP.
2. CONNECT GROUND WIRES
.
TO GREEN TERMINAL AT BOTTOM
OF CASE
/
1
1.\
CHECK ROTATION OF BLOWER MOTOR; TO REVERSE ROTATION. SWITCH LEADS T1 & T3.
4. UNIT DRAWS 25.6 AMPS.
1
5fA
MWAL
<------
Cf)
)
i
rdiS DOCWENT CC;VTAAVS'
PA
.
SPRIErARY WFORMA
T
RUN ALL RiGlfri
AND RILES
PF-3ERVZ'
AND
ZLAY
NOT SE
•
1
:
65Va:AJDED il4
IP-
ME ON IN
o
7
ART
M77-10t r r TtiE WkoFffrtl
.
cor.r..r.,,p. or
r • •.• .K:,-: ;.r.,r•
BR
220—.30
DRAKINC NINEER
NEXT ASSEMBLY
sHrEr
25-93--3089
N/A
1-
1 or r
UNLESS
07^IL
L
IOFSF: LPEariED -
T E VCE5
ARE:
+
-,
.-
XXX
v
apAs v LK:4ms E5soLgais
1ELFCTRICAL SCHEMATIC 220V
301'
94
"
.1
,
ROWN .11/7/97
;
G
re

74FS
DOCA;-Ze7 GATArty'S
.--/ID
D— ERG-380-30, (N)
a
RCPRZTAPY
ii•,:
,,!.,. ■TON
i
'
14'17H
I :,:.
...7:
c=ir,.: AL
9
1:
=
t..,
7fE.
D
NOTES.
REV .
5E3C
4PF.
A '
P
PROD RELEASE
1.
CONNECT GROUND AIRES
TO GREEN
TERMINAL Ar
T OM OF CASE.
2.
CHECK
ROTA17014
OF
SLOttER
MOTOR; TO REVERSE
ROTA
ra
y
.
Siff
TCH LEADS
Ti.
T2
:
7.
:
1.
3.
IM
M•-•■••••••:[•■ ••••■••••■•••=■•••■••••■••~ •
NM
•
•
..1••••MI
414
•/••••••■
••
M•1•15
C••••••• Ea.
• ••••• •
NI•
•
••
a
R4•1
•• ••••••
twee
&VIM
ot•Vrk•rt•r•••• a•••••TS i
■ •
• ••••• • •
• • em• • •
Mt,
■•
WW..
1,7.
•
1•
••1
PIPL
IPURT
5.5-1-
4-E1
50
HEA
?ER
ELDAENT
25-44— 3104
ASSEMBLY'
AcK
fik)
sum.
eV
tc.Aa;
w,••••
1 ea
1
EM
1
aii—rFF
SWAN
320-1
ar
41
MAGNE
TIC
CON T A C TOR
89--11-3002
I
HEArgt ON
PROT
1-
'T
I;
-a5o7
TRANSFORMER
93-11-0001
MAGNETO
STARTER
99-11— 3001
HEAT ERS
F11-27
89•11-5517
i
1!
INSTALLAPC.:11
CONNECTIONS
SUPPL Y HAS
TO BE 390V ME
C Cti;:,
=
= C T CAS
x
(=la% 1=3
BLOWER.
■
I
FUG $.25
ASP
35-11-0001
L
..
_
In
■.a•
1.,•• •■••••••••••••••• n•
-
■
•
••
•■•••
■•••-
••••••.•
••••••• •••••• •rm•M••••••••• •••••• ••••• •-•1.= • 1•1EM II •
•
••I- • ••■•..
•••• Es •,•■•
• M te••
Otamm. • w
• l
■ VS
.
MND • ••••■• • ••••• • • •.• a • ••••-• •
j
wy
wew
E're
:814.12.2t--
-1
—
.--------
(c-■
L

NOTES:
REV.
DESC. DATE
BY-
APP.
1.
— 12 GA. BLACK, P/N 97 —11 —0004;
12 GA.
WM 7E,
P/N
91—
11-0005;
NAM*
8 GA.
BLACK, P/N 91-11-0096.
2.
CONNECT GROUND *WES TO GREEN TERMINAL
AT BOTTOM
OF
CASE.
3.
CHECK ROTATION OF BLOWER MOTOR; TO REVERSE
ROTATION, SWITCH LEADS T1, T2 ee T3.
4. UNIT DRAWS 12.6 AMPS.
PO
PILOT
85-11-0501
LIGHT
1- f
EA TER ELEMENT
ASSEMBL
Y
25-44-3104
i
a.
(W—OFT
MAGNETIC
8
7-11-000
CONTACTOR
89-11-3002
L1
L2
POWER
FUSE,
le-11-000J
6A
I
IN
n
L3
11
MAGNETIC
STARTER
IERMOSTA T
9-11-00'64 89-11-3007
■tonimir
HEATERS
Fl-f-26
TRANSFORMER
89-11— 5501
THERMOSTAT
93-11-0001
PILOT LIGHT
85-11-0501
Ti
T2
T3
RESET
SWITCH
OUTLET
92-11-
aimin
Dairla
A
NPR #4
FUSE, 70 AMP
88-11 — 0002
CONNECTIONS
FOR BLOWER
MOTOR
MATERIAL
ORA
*I
DATE
ELECTRICAL SCHEMATIC
T.
REY
8— 7-89
D
A
HDD— 8RE3
,
— 440-30, (N)
W. O. 508907—25
51:74rag
--
1551/
.1]
s
MIS DOCUMENT CONTAINS
PROPRIETARY
INFORMATION
MTH ALL RIGHTS AND TITLES
RESERVED AND MA
Y
NOT HE
RE
pp
000=
NY
iifiOLE
OR IN
PART MIHOUT THE AR MEN
cpckAs
YU:WENS OSOLIDS
DRAWS HUMBER
25-91-3130
NEXT ASSEMEIL
Y
SHEET
25-54-3128A
1
OF I
REIRSION
A
UNLESS OTHERWISE SPECIFIED
TOLERANCES ARE:
EC.
N
SCALE NAVE
CONSENT Of GALJSO INC.
.
X =
.
XX = *
.
XXX =
1r/LE
NONE
5
1
.
5 1.3r]
Other manuals for HDD-8RB
1
Table of contents
Other Galiso Dryer manuals
Popular Dryer manuals by other brands

Bosch
Bosch WTH83F80CH Installation and operating instructions

Whirlpool
Whirlpool LE6805XP Use & care guide

Bosch
Bosch WTR85VP8SN Installation and operating instructions

Frigidaire
Frigidaire GLGR331D Factory parts catalog

Cissell
Cissell C30STG owner's manual

Bosch
Bosch WTW8M549SN Installation and operating instructions