Gallagher C300698 User manual

3E4465 Gallagher HBUS 8 Port Hub Installation Note | Edition 4 | January 2021
Copyright © Gallagher Group Limited Page 1
Gallagher
HBUS 8 Port Hub
Installation Note
Gallagher HBUS 8 Port Hub: C300698

3E4465 Gallagher HBUS 8 Port Hub Installation Note | Edition 4 | January 2021
Copyright © Gallagher Group Limited Page 2
Disclaimer
This document gives certain information about products and/or services provided by Gallagher Group Limited
or its related companies (referred to as "Gallagher Group").
The information is indicative only and is subject to change without notice meaning it may be out of date at any
given time. Although every commercially reasonable effort has been taken to ensure the quality and accuracy
of the information, Gallagher Group makes no representation as to its accuracy or completeness and it should
not be relied on as such. To the extent permitted by law, all express or implied, or other representations or
warranties in relation to the information are expressly excluded.
Neither Gallagher Group nor any of its directors, employees or other representatives shall be responsible for
any loss that you may incur, either directly or indirectly, arising from any use or decisions based on the
information provided.
Except where stated otherwise, the information is subject to copyright owned by Gallagher Group and you
may not sell it without permission. Gallagher Group is the owner of all trademarks reproduced in this
information. All trademarks which are not the property of Gallagher Group, are acknowledged.
Copyright © Gallagher Group Ltd 2021. All rights reserved.

3E4465 Gallagher HBUS 8 Port Hub Installation Note | Edition 4 | January 2021
Copyright © Gallagher Group Limited Page 3
Contents
1Introduction ......................................................................................................................................... 4
2Before you begin.................................................................................................................................. 4
2.1 Shipment contents.................................................................................................................... 4
2.2 Power supply ............................................................................................................................ 4
2.3 Cabling ...................................................................................................................................... 4
2.4 Connections .............................................................................................................................. 5
2.5 Component layout.................................................................................................................... 5
2.6 HBUS device limits .................................................................................................................... 6
2.7 HBUS LED diagnostic indications .............................................................................................. 6
3Installation ........................................................................................................................................... 6
4Command Centre configuration .......................................................................................................... 6
5Approvals and standards ..................................................................................................................... 7
6Technical specifications ....................................................................................................................... 8
7Unit dimensions ................................................................................................................................... 8

3E4465 Gallagher HBUS 8 Port Hub Installation Note | Edition 4 | January 2021
Copyright © Gallagher Group Limited Page 4
1Introduction
The Gallagher HBUS 8 Port Hub provides installers with the flexibility to re-use existing wiring on site,
allowing combinations of star/home run and daisy chain wiring to be used when connecting HBUS devices
back to a Gallagher Controller 6000. It utilises a FPGA (field programmable gate array) to allow for the
star wiring of devices.The HBUS 8 Port Hub is not a monitored device and therefore is transparent to the
Controller.
Note: UL have evaluated the 8 Port Hub with readers and alarm terminals only. Tension sensor and
Fence Controller equipment have not been evaluated as they are not subject to the UL294 listing.
2Before you begin
2.1 Shipment contents
Check the shipment contains the following items:
•1 x Gallagher HBUS 8 Port Hub
•1 x Gallagher HBUS 8 Port Hub Installation Note (this note)
•4 x 4G X 1/4" pan pozi screws
2.2 Power supply
The Gallagher HBUS 8 Port Hub requires a 13.6 Vdc + 15% power supply. This is connected
through the 2 pin connector labelled Vin. The 2 pins are labelled -and +.The terminals VOUT
and GND provide a 13.6 Vdc + 15% output suitable for HBUS connections, rated at 4A total from
all outputs.
2.3 Cabling
The end devices on the HBUS cable should be terminated using 120 Ωresistance. Termination is
already included at the HBUS Module out ports, (i.e. each HBUS out port is permanently
terminated at the module).

3E4465 Gallagher HBUS 8 Port Hub Installation Note | Edition 4 | January 2021
Copyright © Gallagher Group Limited Page 5
The In port has an optional termination jumper J2 TERM. Whether this jumper is used or not
should be based on the In port to Controller wiring.
2.4 Connections
Note: Run a common ground (-ve) from the HBUS 8 Port Hub for all RS485 devices.
2.5 Component layout

3E4465 Gallagher HBUS 8 Port Hub Installation Note | Edition 4 | January 2021
Copyright © Gallagher Group Limited Page 6
2.6 HBUS device limits
The RS485 device limits of the Controller 6000 must still be met.
2.7 HBUS LED diagnostic indications
The diagnostic LED is labelled “RUN” on the HBUS 8 Port Hub.
1 Flash (Red) indicates that it is functioning normally.
3Installation
ATTENTION: This equipment contains components that can be damaged by electrostatic
discharge. Ensure both you and the equipment are earthed before beginning any
servicing.
The Gallagher HBUS 8 Port Hub can be mounted in a Gallagher Starter Kit Cabinet (C300120), Gallagher
Cabinet (C200100) or Gallagher Dual Cabinet (C200104 or C200105).
Notes:
•The HBUS Hub should be located within an enclosure that has Tamper Detection.
•The wiring from the Controller HBUS Port to the HBUS Hub should comply with the cable
requirements of HBUS.
•The Power for the HBUS Hub should be provided from a fused source, and sufficient to supply the 8
outgoing Power Connections.
1. Refer to the appropriate Gallagher Cabinet installation note below for details regarding the
procedures involved when mounting the Gallagher Cabinet.
−Gallagher Starter Kit Cabinet Installation Note (3E3723)
−Gallagher Two Door Controller Cabinet Installation Note (3E3721)
−Gallagher Cabinet Installation Note (3C4513)
−Gallagher Dual Cabinet Installation Note (3E0694)
2. Install a Gallagher Mounting Plate (C200001, C200002 or C200003) directly into the cabinet.
3. Using the 4 pan pozi screws supplied, fit the HBUS 8 Port Hub to the installed Gallagher Mounting
Plate.
4. Connect the RS485 IN/OUT, inputs and outputs as detailed in the topic “Connections” earlier in this
note.
4Command Centre configuration
There is no Command Centre Configuration for the HBUS 8 Port Hub, if inserted into the wiring it is
invisible to the Controller and to the HBUS devices connected to that HBUS.

3E4465 Gallagher HBUS 8 Port Hub Installation Note | Edition 4 | January 2021
Copyright © Gallagher Group Limited Page 7
5Approvals and standards
FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
Note: Changes or modifications not expressly approved by Gallagher Limited could
void the user's authority to operate this equipment.
Note: This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This product complies with the environmental regulations for the Restriction of
Hazardous Substances in electrical and electronic equipment (RoHS). The RoHS
directive prohibits the use of electronic equipment containing certain hazardous
substances in the European Union.
This symbol on the product or its packaging indicates that this product must not be
disposed of with other waste. Instead, it is your responsibility to dispose of your waste
equipment by handing it over to a designated collection point for the recycling of
waste electrical and electronic equipment. The separate collection and recycling of
your waste equipment at the time of disposal will help conserve natural resources and
ensure that it is recycled in a manner that protects human health and the
environment. For more information about where you can drop off your waste
equipment for recycling, please contact your local city recycling office or the dealer
from whom you purchased the product.
AS/NZS IEC 60839.11.1:2019 Grade 4, Class II
EN50130-4
EN55022

3E4465 Gallagher HBUS 8 Port Hub Installation Note | Edition 4 | January 2021
Copyright © Gallagher Group Limited Page 8
6Technical specifications
Operating voltage (Vin): 13.6 Vdc + 15%
Operating current at 13.6 Volts: 20 mA
Available current from each HBUS
outgoing port:
1 x 4A resettable fuse supplying all output power ports
Temperature range: -10 °C to 50 °C (14 °F to 122 °F)
0 °C to 49 °C (32 °F to 120 °F)
(Independently verified)
(UL certified)
Humidity:95% non-condensing
85% non-condensing
(Independently verified)
(UL certified)
Power and Comms cable length: Depends on power requirements of end devices
Comms only cable length:up to 500m
Cable length using Gallagher HBUS Cable: up to 500m
Height:
Width:
Depth:
30 mm (1.2 in) with connectors
87 mm (3.4 in)
88 mm (3.5 in)
7Unit dimensions
IMPORTANT
This picture is not to scale, therefore use the measurements provided.
Table of contents
Popular Switch manuals by other brands

Soldo Controls
Soldo Controls SIS Series manual

Alcatel-Lucent
Alcatel-Lucent OmniSwitch 6850-48 Brochure & specs

Icy Box
Icy Box IB-HUB1410-C3 Quick installation guide

HP
HP 316095-B21 - StorageWorks Edge Switch 2/24 release note

Altusen
Altusen KH-88 user manual

Cisco
Cisco 2975 - Catalyst LAN Base Switch Hardware installation guide