Asse ble the safety valve e.g. Zb9 by Orkli (Spain) on the cold water feed pipe according
to the arrow indicating the direction of water flow that is located on valve body. In the
heater, the safety valve enables to decrease the pressure without water outflow outside
through its flow to the feeding syste . It opens the outflow in case of differential pressure
in the heater and the syste a ounting to 0.07+0.03/-0.02 MPa; therefore, in the distance
of 5 eters fro the safety valve, the cold water feed pipe should endure te perature
+90°C (due to the possibility of hot water flow fro the container to the syste ). The
discharge hole of the safety valve needs to be constantly open - connected with the
at osphere.
4. Note !!!
1. Connect the external tank to the central heating syste after the internal tank is filled in
with water.
2. The safety valve hast to be asse bled directly before the heater on the cold water feed
pipe. Use only and solely valves adjusted to storage water heaters that also include a non-
return valve.
3. There can be no additional devices (e.g. a cut-off valve, a non-return valve etc.)
between the safety valve and the heater.
4. Do not use the heater without operational safety valve. Check operation of the safety
valve every 14 days by turning the hood right or left so that there is a discharge fro the
side external outlet. Then turn
the hood in the opposite direction until it clicks in the previous position and press it down
to the valve body. Note - there is a possibility of hot water discharge. The co pany
disclai s any responsibility for alfunctioning of the safety valve resulting fro incorrect
valve fitting. The axi u pressure of fully open safety valve cannot exceed 0.67 MPa.
for C/H containers however for buffer tank in syste closed 0.35 MPa..
5. Do not try to prevent water fro dripping fro the safety valve - do not plug the
discharge hole of the safety valve. If water constantly leaks out fro the safety valve, it
eans that the pressure in the water supply syste is too high or the safety valve is out of
order. The valve outlet should be directed downwards. It is reco enced that a funnel
that discharges water is placed under the valve. It is also possible to place a hose on the
outlet that discharges water leakage arising when opening the safety valve. The hose
should be resistant to te perature up to +80°C, have a 9 internal dia eter and 1.2
axi u length, led to the outlet with a downward slope ( in. 3%) in the environ ent in
which te perature does not fall below 0°C. The hose required protection against
decreasing opening area (folding, plugging) and its outlet should be visible (to check valve
operation).
6. There cannot by any devices that cause the so-called water ha er in the syste in
which the heater is fitted, e.g. a ball valve used as a flushing valve.
7. Switch the heater off i ediately if s oke co es out of any battery (notify the
anufacturer).
8. Check the protection of the heater by easuring neutral grounding effectiveness at
least once a year.
9. Connection of the heater to the ains without a grounding pin ay result in
electrocution in case of failure of electric equip ent.
10. At least once a year, replace the agnesiu anode in ena eled containers (excluded
fro the guarantee service).
11. To extend se vice life of the containe and ensu e effective ope ation of the safety
valve, use filte s