Gantner GT7.2500 User manual

Typische Anwendung
1 ......Spannungsversorgung
2 ......Netzwerkkabel (Ethernet)
3 ......Netzwerk
4 ......zum Server
5 ......RFID Datenträger
6 ......elektronisches Schloss
7 ......Türkontakt
8 ......Netzwerk und Versorgung (PoE)
9 ......Elektronische Schrankschlösser
(Infoanzeige Schranknummer)
10 ...Solarium (Zeitsteuerung)
11 ...Relaisbox
Bestellhinweise
Beschreibung Art.Nr.
GT7.2500
Multifunktionales RFID Terminal, mit Basis Access App (andere
Apps siehe Artikel G7 Connect License Points), Ethernet, PoE,
1 Relaisausgang, 1 Statuseingang
919128
GT7.3500
Multifunktionales RFID Terminal, mit Basis Access App (andere Apps
siehe G7 Connect License Points), Ethernet, PoE, 2 Relaisausgänge,
1 Statuseingang, Wiegand-, RS-232- und RS-485-Schnittstellen
919229
GT7b.2000
Fingerabdrucklesermodul für das GT7.2500 und GT7.3500
982936
G7 Connect License Points
Lizenzpunkte für Apps (Time, Info, ...), um die gewünschte
Funktion des Terminals zu aktivieren
-
GAT NET.Power Supply 100-240V
Netzteil zur Spannungsversorgung des GT7.2500 und GT7.3500
369434
GAT NET.Power Cord EU
GAT NET.Power Cord UK
GAT NET.Power Cord AUS
GAT NET.Power Cord US
GAT NET.Power Cord IND
Netzkabel für verschiedene Steckersysteme
494181
494282
511474
636835
636734
Typical Application
1 ......Power supply
2 ......Network cable (Ethernet)
3 ......Network
4 ......To server
5 ......RFID data carrier
6 ......Electronic lock
7 ......Door contact
8 ......Network and supply (PoE)
9 ......Electronic locker locks
(info display of locker no.)
10 ..Sunbed (time control)
11 ..Relay box
Order Information
Description Part No.
GT7.2500
Multi-functional RFID terminal, with Basic Access App (other
apps see article G7 Connect License Points), Ethernet, PoE, 1
relay output, 1 status input
919128
GT7.3500
Multi-functional RFID terminal, without app (see G7 Connect
License Points), Ethernet, PoE, 2 relay outputs, 1 status input,
and with Wiegand, RS-232 and RS-485 interfaces
919229
GT7b.2000
Fingerprint module for the GT7.2500 and GT7.3500
982936
G7 Connect License Points
Licence points for apps (Time, Info, ...) to activate the desired
terminal functionality
-
GAT NET.Power Supply 100-240V
Power supply for supplying the GT7.2500 and GT7.3500
369434
GAT NET.Power Cord EU
GAT NET.Power Cord UK
GAT NET.Power Cord AUS
GAT NET.Power Cord US
GAT NET.Power Cord IND
Power supply cable suitable for different power plug standards
494181
494282
511474
636835
636734
GT7.2500, GT7.3500
Multifunktionales RFID Terminal
DE EN
DE
EN weiß
DE EN
GT7.2500, GT7.3500
Multifunctional RFID Terminal
DE EN
DE
EN
weiß
DE EN
www.gantner.com
Die multifunktionell einsetzbaren Terminals GT7.2500
und GT7.3500 ermöglichen durch die Ausführung einer
jeweiligen App auf dem Gerät unter anderem die Steuerung
von Drehkreuzen und Türen (Access App), die Anzeige von
Schrankinformationen oder Besucherinformationen (Info
App) oder die zeitgesteuerte Steuerung von Geräten wie
Solarien bzw. Whirlpools (Time App).
Benutzer identifizieren sich mit deren persönlichen
Datenträgern über RFID (Radio Frequency Identification,
NFC (Near Field Communication) oder Funkschnittstelle am
integrierten Leser. Die übersichtliche Oberfläche des Touch-
Displays begleiten den Anwender durch die verschiedenen,
klar strukturierten Ebenen. Die verschiedenen
Ausführungsarten erlauben einen flexiblen Einsatz des
Terminals. Die GT7 Terminals sind sowohl für den Einsatz in
Innen- als auch geschützten Außenbereichen geeignet.
The multipurpose configurable GT7.2500 and GT7.3500
terminals allow different functions to be implemented
through the installation of various apps on the device.
The functions available include the control of turnstiles
and doors (Access App), the display of locker information
or visitor information (Info App), or the timed control of
devices such as solariums or spas (Time App).
Users identify themselves at the integrated reader using
their personal data carriers and wireless transmission
via RFID (Radio Frequency Identification), NFC (Near
Field Communication) or wireless interface. The ultra-
clear touchscreen interface intelligently guides the user
through the various clearly structured levels. The range of
executable apps allow the flexible use of the terminal. The
GT7 terminals are suitable for both indoor and protected
outdoor use.
1
GT7.2500 / GT7.3500
(Access App)
GT7.2500 / GT7.3500
(Info App)
GT7.2500 / GT7.3500
(Time App)
2
8
9
10
8
3
4
6
5
7i
12 13 14 15
11

Technical Data
DE
EN
DE EN weiß
DE EN
DE
EN
DE EN weiß
DE EN
Gerätemerkmale und Abmessungen
1 ......Kamera (optional)
2 ......Anzeige
3 ......RFID-Leser mit Status LED
4 ......Unterteil
5 ......Oberteil
6 ......RFID-Leserabdeckung
Maße in mm
Device Features and Dimensions
1 ....... Camera (optional)
2 ....... Display
3 ....... RFID reader with status LED
4 ....... Rear part
5 ....... Front part
6 ....... RFID reader cover
Measurements in mm
Technische Daten
Nennspannung - Netzgerät:
- PoE:
DC 24 V (LPS/SELV)
PoE konf. zu IEEE 802.3af, Leistungsklasse 0
Zul. Spannungsbereich
- Netzgerät:
- PoE:
DC 10 - 26 V (LPS/SELV)
DC 36 - 57 V
Stromaufnahme - Netzgerät:
- PoE:
900 mA
300 mA
Ausgangsstrom - Vout 24V:
- Vout 5V:
max. 300 mA
max. 300 mA
Datenspeicher: Flashspeicher für Konfigurations- und
Buchungsdaten, Hintergrundbild, sowie
Bilder für Werbeanzeigen.
Interne Uhr: Zeiterhalt 1 Stunde
Lesertyp: - MIFARE: Classic (1k und 4k), Ultralight®,
DESFire EV1®und EV2®
- ISO 15693
- Gantner.Connect
Frequenz Lesefeld - RFID:
- Funkschnitt.:
13,56 MHz
2,4 GHz
Max. Sendeleistung - RFID:
- Funkschnitt.:
500 mW
3,7 dBm (2,344 mW)
Lesereichweite: 2 - 8 cm (je nach Datenträger)
WLAN Standard: IEEE 802.11b/g/n
Anzeigeelemente/Signalisierung
- Anzeige:
- RFID-Leser:
- Akustischer Signalgeber:
4,3“ Farbdisplay mit kapazitivem Touchscreen,
16,7 Millionen Farben, Auflösung 480 x 272
Pixel, sichtbarer Bereich 95,04 x 53,86 mm
LED Farbring, verschiedene Farben
Lautsprecher
Sensoren: - Kamera mit 5 Megapixel, RGB (GT7.3500)
- Mikrofon (GT7.3500)
Signaleingang
- Eingangsspannung:
1 x Optokoppler (Funktion konfigurierbar)
DC 0 bis 30 V (ULow <2 V, UHigh >6 V)
Signalausgang
- Schaltungsspannung DC:
- Schaltungsspannung AC:
- Dauerstrom:
- Schaltleistung:
GT7.2500 1 x Relais, GT7.3500 2 x Relais
(NO, Funktion/Zeitverhalten konfig.)
max. 30 V (SELV)
max. 15 V (SELV)
max. 1,8 A
max. 54 W, 27 VA
Host-Schnittstelle: - Ethernet 10/100 MBit/s, IPv4 und IPv6
- WLAN (bei GT7.3500)
Leserschnittstellen (GT7.3500): - RS-232 (Barcode)
- RS-485 (Gantner Erweiterungsbus)
- Wiegand
Anschluss: Schraubklemmen, 0,5 bis 1,5 mm
Softwareintegration: - JSON Schnittstelle
- Generation 6 Kompatibilitätsadapter
(eingeschränkte Funktionen)
Gehäuse - Unter-/Oberteil:
- Leserabdeckung:
- Front:
Kunststoff PC schwarzgrau
Kunststoff PC In-mould Technologie
gehärtetes Glas
Abmessungen: 127,1 x 151,1 x 24,7 mm
Gewicht: 370 g
Zul. Umgebungstemperatur: -10 bis +50 °C
Lagertemperatur: -25 bis +70 °C
Schutzart: IP 52 (eingebauter Zustand)
Schutzklasse: III (Schutz durch Kleinspannung)
Zulassungen CE
Umweltklasse in Anl. an VdS 2110: III (Bedingungen im Freien, witterungsgeschützt)
VB_GT7-2500-3500--DE+EN_11 • Art.Nr.: 1100341
Gültig ab 9. August 2018
Technische Änderungen vorbehalten!
Seite 2
VB_GT7-2500-3500--DE+EN_11 • Part No.: 1100341
Valid as of 9th August, 2018
Technical data subject to modification without notice!
Page 2
GANTNER Electronic GmbH
Montafonerstr. 8 • 6780 Schruns/Austria
127.1
24.7
10.2
151.1
2
3
5
6
4
1
Nominal voltage - Power supply unit:
- PoE:
DC 24 V (LPS/SELV)
PoE conf. to IEEE 802.3af, performance class 0
Permitted voltage range
- Power supply unit:
- PoE:
DC 10 - 26 V (LPS/SELV)
DC 36 - 57 V
Power consump. - Power supply unit:
- PoE:
900 mA
300 mA
Ouput current - Vout 24V:
- Vout 5V:
max. 300 mA
max. 300 mA
Data storage: Flash memory for configuration and booking
data, wallpaper, and advertisement pictures.
Internal clock: Time saved 1 hour
Reader type: - MIFARE: Classic (1k and 4k), Ultralight®,
DESFire EV1®and EV2®
- ISO 15693
- Gantner.Connect
Reading field frequ. - RFID:
- Wireless int.:
13.56 MHz
2.4 GHz
Max. transm. power - RFID:
- Wireless int.:
500 mW
3.7 dBm (2.344 mW)
Reading range: 2 - 8 cm (depending on the data carrier)
WLAN standard: IEEE 802.11b/g/n
Display elements/signaling
- Display:
- RFID reader:
- Acoustic signaling:
4.3´´ color display with capacitive touch-
screen, 16.7 million colors, resolution 480 x
272 px, visible area 95.04 x 53.86 mm
LED color ring, different colors
Speaker
Sensors: - 5 megapixel RGB camera (GT7.3500)
- Microphone (GT7.3500)
Signal input
- Input voltage:
1 x optocoupler (function configurable)
DC 0 to 30 V (ULow <2 V, UHigh >6 V)
Signal output
- Circuit voltage DC:
- Circuit voltage AC:
- Continuous current:
- Switching capacity:
GT7.2500 1 x relay, GT7.3500 2 x relays
(NO, function/timing configurable)
max. 30 V (SELV)
max. 15 V (SELV)
max. 1.8 A
max. 54 W, 27 VA
Host interface: - Ethernet 10/100 Mbps, IPv4 and IPv6
- WLAN (with GT7.3500 variant)
Reader interfaces (GT7.3500): - RS-232 (barcode)
- RS-485 (Gantner expansion bus)
- Wiegand
Connection: Screw terminals, 0.5 - 1.5 mm
Software integration: - JSON interface
- Generation 6 compatibility adapter
(limited functions)
Housing - Front/rear part:
- Reader cover:
- Display:
Plastic PC black gray
Plastic PC In-mould technology
Hardened glass
Dimensions: 127.1 x 151.1 x 24.7 mm (5.0 x 5.9 x 0.97´´)
Weight: 370 g (13 oz)
Permitted ambient temperature: -10 to +50 °C (+14 to +122 °F)
Storage temperature: -25 to +70 °C (-13 to +158 °F)
Protection type: IP 52 (installed state)
Protection class: III (Safety Extra-Low Voltage)
Compliances: CE
Environment class based on VdS 2110:
III (conditions in outside area, protected
from weather)

Installation
Die GT7 Terminals sind für die Montage auf einer ebenen Fläche vorgesehen.
Sie können aufputz oder halbversenkt in einem Wandausschnitt montiert werden.
Weiters können die Terminals auch halbversenkt in einer Tischplatte installiert
werden.
Empfohlene Montagehöhe gemessen bis zur Displaymitte = 1,3 m.
Die Montage ist für das GT7.2500 und das GT7.3500 identisch.
Montage des Unterteils
Wird das GT7 im Außenbereich oder an einem Ort montiert, der nicht vor
Tropfwasser geschützt ist, muss die Wanddichtung (7) verwendet werden.
1. Ziehen Sie die Schutzfolie von der
Rückseite der Dichtung ab.
2. Kleben Sie die Wanddichtung wie im
Bild gezeigt auf der Rückseite des
Untereteils auf. Achten Sie darauf,
dass die Dichtung zwischen den Kuppen
des Gehäuses flach aufliegt.
4 ......Unterteil
7 ......Wanddichtung
Maße in mm
3. Bohren Sie zur Befestigung des Unterteils die entsprechenden Befestigungs-
löcher in der Wand oder Tischplatte. Folgende 3 Möglichkeiten stehen zur
Auswahl:
a) Aufputzmontage ohne UP-Dose (3 Bohrungen).
b) Montage auf eine Standard 60 mm UP-Dose (3 Bohrungen).
c) Halbversenkter Einbau (Ausschnitt ca. 118 x 136 mm und 4 Bohrungen).
Maße in mm
4. Setzen Sie das Unterteil auf die Bohrungen und führen Sie dabei die
Anschlusskabel durch die mittlere Öffnung im Unterteil.
5. Schrauben Sie das Unterteil auf die Wand oder in die Tischplatte.
Installation
The GT7 terminals are designed for mounting onto a flat surface. They can be
surface mounted or semi-flush mounted in a wall cutout or, alternatively, the
terminals can be semi-flush mounted in a desk top.
Recommended mounting height: 1.3 m to middle of device display.
The mounting procedure is identical for the GT7.2500 and the GT7.3500.
Mounting the Rear Part
If the GT7 are being installed in an outdoor area or another location that is not
protected against dripping water, the wall gasket (7) must be used.
1. Remove the protective foil from the back of
the wall gasket.
2. Stick the wall gasket onto the back of the
rear part as shown in the picture to the left.
Ensure that the gasket sits flat between
the domes of the housing.
4 ......Rear part
7 ......Wall seal
Measurements in mm
3. To mount the rear part, drill the appropriate mounting holes in the wall or desk
top. The following 3 options are available:
a) Surface mounting without flush-mounted box (3 holes).
b) Mounting on a standard 60 mm flush-mounted box (3 holes).
c) Semi-flush mounting (approx. 118 x 136 mm cutout and 4 holes).
Measurements in mm
4. Align the rear part with the mounting holes while guiding the connection
cables through the central opening in the rear part.
5. Screw the rear part onto the wall or into the desk top.
Safety Instructions
- The installation and maintenance of this device must be performed
by trained, qualified personnel.
- All applicable safety and accident prevention regulations must be
observed.
- Safety devices must not be removed.
- Please observe the technical data of the device specified in this
datasheet.
- The device must be disconnected from the power supply prior to
installation, assembly, or disassemly.
Sicherheitshinweise
- Die Installation und Wartung dieses Gerätes darf nur durch
geschultes, fachkundiges Personal erfolgen.
- Die geltenden Sicherheits- und Unfallverhütungsvorschriften sind
zu beachten.
- Schutzeinrichtungen dürfen nicht entfernt werden.
- Beachten Sie die im Datenblatt angegebenen technischen Daten
des Geräts.
- Vor Arbeiten am Gerät oder Montage/Demontage muss das Gerät
spannungsfrei geschaltet werden.
DE
EN
DE EN weiß
DE EN
DE
EN
DE EN weiß
DE EN
VB_GT7-2500-3500--DE+EN_11 • Art.Nr.: 1100341
Gültig ab 9. August 2018
Technische Änderungen vorbehalten!
Seite 3
VB_GT7-2500-3500--DE+EN_11 • Part No.: 1100341
Valid as of 9th August, 2018
Technical data subject to modification without notice!
Page 3
GANTNER Electronic GmbH
Montafonerstr. 8 • 6780 Schruns/Austria
1.0
7
7
4 4
93.1
abc14.5
113.3
13.5
122.9
114.1
117.0
14.5
146.9
142.5
4.4
135.8
60.0
68.3
98.3

Befestigung des Oberteils
In diesem Abschnitt wird beschrieben, wie die Montage durch Aufstecken des
Oberteils und der RFID-Leserabdeckung abgeschlossen wird. Bevor Sie diese
Schritte ausführen, schließen Sie zuerst die Anschlusskabel an. Lesen Sie dazu
die Hinweise in Abschnitt “Elektrischer Anschluss“ auf Seite 5.
ACHTUNG! Elektrischer Schlag. Der Anschluss muss im spannungslosen
Zustand erfolgen.
HINWEIS! Achten Sie darauf, dass die Elektronik und Printplatte des GT7 bei
der Montage nicht beschädigt oder verkratzt wird.
1. Kontrollieren Sie, dass die am inneren Rand des Oberteils eingelegte
Dichtung (8) und der zentrale Verbindungsstecker (9) sauber und
unbeschädigt sind.
ACHTUNG! Benutzen Sie keine Flüssigkeiten zur Reinigung.
2. Haken Sie das Oberteil mit den 2 Laschen an der Oberseite des Unterteils
ein (10).
3. Klappen Sie das Oberteil auf das Unterteil (11).
4. Drücken Sie das Oberteil mit leichtem Druck auf das Unterteil, bis es in den
Laschen um den Rand des Unterteils einrastet (12).
Üben Sie nicht zu viel Druck aus. Sollte das Aufstecken nicht ohne starken
Krauftaufwand möglich sein, kontrollieren Sie die Laschen und den zentralen
Verbindungsstecker und wiederholen Sie den Vorgang.
HINWEIS! Mit diesem Prozess wird auch das Oberteil mit dem Unterteil
elektrisch über den zentralen Verbindungsstecker (9) verbunden.
HINWEIS! Das Oberteil muss bündig mit dem Unterteil abschließen (siehe
rechtes Bild oben) und festen Halt haben.
5. Drehen Sie die Befestigungsschraube (13) in das Oberteil, um dieses fest mit
dem Unterteil zu verbinden.
6. Stecken Sie die RFID-Leserabdeckung (6) auf das Oberteil auf. Es rastet mit
3 Laschen ein.
HINWEIS! Die Leserabdeckung muss bündig mit dem Oberteil ab-
schließen und festen Halt haben.
Öffnen des Gehäuses
Sollte das Gehäuse z. B. zur Verkabelungsänderung oder für Servicezwecke
geöffnet werden müssen, gehen Sie wie folgt vor:
1. Lösen Sie die RFID-Leserabdeckung mit einem Schlitz-Schraubendreher an
den 3 seitlichen Laschen und nehmen Sie die Abdeckung ab.
2. Drücken Sie an den vier im folgenden Bild gekennzeichneten Schlitzen im
Gehäuseoberteil die Ränder nach außen, so dass sich die Laschen darunter
lösen und nehmen Sie das Oberteil vom Unterteil ab.
RFID-Leserabdeckung lösen Oberteil lösen
Attaching the Front Part
This section describes how to complete the installation by attaching the front
part and RFID reader cover. Before completing these steps, first connect the
connection cables. For more information, read the “Electrical Connections” section
on page 5.
CAUTION! Electrical shock. The electrical connections must be made in a
de-energized state.
NOTE! Make sure that the electronics and printed circuit board of the GT7 are
not damaged or scratched during assembly.
1. Check that the gasket (8), which is inserted in the inner edge of the front
part, and the central connector (9) are clean and undamaged.
CAUTION! Do not use liquids for cleaning.
2. Hook the 2 tabs of the front part over the top of the rear part (10).
3. Swing the front part forward onto the rear part (11).
4. Gently press the front part onto the rear part until it snaps into the tabs
around the edge of the rear part (12).
Do not exert too much pressure. If the front part cannot be attached without
great effort, check the tabs and the central connector and repeat the process.
NOTE! Through this process, the front part is electrically connected to the
rear part via the central connector (9).
NOTE! The front part must sit flush with the rear part (see picture above)
and be securely attached.
5. Tighten the fixing screw (13) into the front part to firmly attach it to the rear
part.
6. Attach the RFID reader cover (6) to the front part. It locks into place via 3
tabs.
NOTE! The reader cover must sit flush with the front part and be securely
attached.
Opening the housing
Should the housing need to be opened, e.g., for cabling modifications or servicing,
proceed as follows:
1. Release the RFID reader cover using a flat-blade screwdriver on the 3 side
tabs and remove the cover.
2. On the 4 slots in the front part as indicated in the picture below right, press
the edges outwards so that the tabs underneath release and remove the front
part from the rear part.
Release RFID reader cover Release front part
DE
EN
DE EN weiß
DE EN
DE
EN
DE EN weiß
DE EN
VB_GT7-2500-3500--DE+EN_11 • Art.Nr.: 1100341
Gültig ab 9. August 2018
Technische Änderungen vorbehalten!
Seite 4
VB_GT7-2500-3500--DE+EN_11 • Part No.: 1100341
Valid as of 9th August, 2018
Technical data subject to modification without notice!
Page 4
GANTNER Electronic GmbH
Montafonerstr. 8 • 6780 Schruns/Austria
8
9
10
11
12 6
13
13

DE
EN
DE EN weiß
DE EN
DE
EN
DE EN weiß
DE EN
VB_GT7-2500-3500--DE+EN_11 • Art.Nr.: 1100341
Gültig ab 9. August 2018
Technische Änderungen vorbehalten!
Seite 5
VB_GT7-2500-3500--DE+EN_11 • Part No.: 1100341
Valid as of 9th August, 2018
Technical data subject to modification without notice!
Page 5
GANTNER Electronic GmbH
Montafonerstr. 8 • 6780 Schruns/Austria
Elektrischer Anschluss
ACHTUNG! Elektrischer Schlag. Trennen Sie immer die Versor-
gungsspannung, bevor Sie elektrische Verbindungen ändern.
Anschlussbeispiel GT7.2500
Anschlussbeispiel GT7.3500
1 ......Netzwerk (TCP/IP)
2 ......Ethernet-Switch
3 ......PoE-Switch
4 ......Netzteil
5 ......Netzspannungsanschluss
6 ......Elektrischer Rückmeldekontakt
7 ......Freilaufdiode
8 ......Motorsteurung mit externer Versorgung
9 ......Leserschnittstelle
10 ...busfähiger, externer Leser (z. B. GAT SR 7xxx oder GAT SLR 7xxx Serien)
Netzwerk (Ethernet)
Verbinden Sie das Ethernet-Kabel an einem eigenen Port des Netzwerk-Switch.
Der für alle Ethernet-Verbindungen empfohlene Kabeltyp ist min. CAT 5 (STP) für
100 MBit. Die Aderfarben sind wie folgt:
Klemme Signal Adernfarbe
TIA-568A
Adernfarbe
TIA-568B
RX
-
Empfangssignal RX
-
grün orange
RX+ Empfangssiganal RX+ grün/weiß orange/weiß
TX
-
Sendesignal TX
-
orange grün
TX+ Sendesignal TX+ orange/weiß grün/weiß
Shld Schirm - -
DC+ PoE Versorgung + blau/weiß blau/weiß
DC+ PoE Versorgung + blau blau
DC
-
PoE Versorgung - braun/weiß braun/weiß
DC
-
PoE Versorgung - braun braun
Electrical Connections
CAUTION! Electrical shock. Always disconnect the power supply
before altering electrical connections.
Connection example GT7.2500
Connection example GT7.3500
1 ......Network (TCP/IP)
2 ......Ethernet switch
3 ......PoE switch
4 ......Power supply
5 ......Mains voltage connection
6 ......Electric feedback contact
7 ......Freewheeling diode
8 ......Motor control with external supply
9 ......Reader interface
10 ...Bus-capable, external readers (e.g., GAT SR 7xxx or GAT SLR 7xxx Series )
Network (Ethernet)
Connect the Ethernet cable to a separate port on the network switch. The
recommended cable type for all Ethernet connections is min. CAT 5 (STP) for 100
Mbps. The wire colors are as follows:
Terminal Signal Wire Color
TIA-568A
Wire Color
TIA-568B
RX
-
Receive signal RX
-
green orange
RX+ Receive signal RX+ green/white orange/white
TX
-
Send signal TX
-
orange green
TX+ Send signal TX+ orange/white green/white
Shld Shield - -
DC+ PoE Supply + blue/white blue/white
DC+ PoE Supply + blue blue
DC
-
PoE Supply - brown/white brown/white
DC
-
PoE Supply - brown brown
ETHERNET
Shld
TX+
TX
-
RX+
RX
-
ETHERNET PoE
DC
-
DC
-
DC+
DC+
Rel. 2 VOut 2
NO
C
GND
24 V
Rel. 2 VOut 2
NO
C
GND
24 V
VOut 1Rel. 1
NO
C
GND
24 V
Opto VIn
IN
-
IN+
GND
24 V
Wieg.
5V
CLK
DATA
GND
RX
TX
RS-485RS-232
GND
B
VOUT
(24V)
A
Wieg.
5V
CLK
DATA
GND
RX
TX
RS-485RS-232
GND
B
OUT
(24V)
A
G7 ECO+
1
910
3
ETHERNET
Shld
TX+
TX
-
RX+
RX
-
VOut 1Rel. 1
NO
C
GND
24 V
Opto VIn
IN
-
IN+
GND
24 V
ETHERNET PoE
DC
-
DC
-
DC+
DC+
ETHERNET
Shld
TX+
TX
-
RX+
RX
-
VOut 1Rel. 1
NO
C
GND
24 V
Opto VIn
IN
-
IN+
GND
24 V
1N S
VOut+
GND
4 5
2
6
7
8
VOut 1Rel. 1
NO
C
GND
24 V
Opto VIn
IN
-
IN+
GND
24 V
M
ETHERNET PoE
DC
DC
DC+
DC+
ETHERNET
Shld
TX+
TX
-
RX+
RX
-
ETHERNET PoE
DC
-
DC
-
DC+
DC+

DE
EN
DE EN weiß
DE EN
DE
EN
DE EN weiß
DE EN
VB_GT7-2500-3500--DE+EN_11 • Art.Nr.: 1100341
Gültig ab 9. August 2018
Technische Änderungen vorbehalten!
Seite 6
VB_GT7-2500-3500--DE+EN_11 • Part No.: 1100341
Valid as of 9th August, 2018
Technical data subject to modification without notice!
Page 6
GANTNER Electronic GmbH
Montafonerstr. 8 • 6780 Schruns/Austria
Elektrischer Anschluss
Empfohlene Kabel / Leitungslängen für Ethernet
• Geschirmte und verdrillte Datenleitung (Empfehlung min. CAT 5).
• Versorgungsspannung über 2 Adernpaare
• Leitungslänge max. 100 m.
Spannungsversorgung
Beim GT7 Terminal kann die Versorgungsspannung von einem Netzgerät geliefert
werden (LPS und SELV - Limited Power Source und Sicherheitskleinspannung).
Es besteht außerdem die Möglichkeit, anstelle des Netzgeräts die Versorgung
über Ethernet zu nutzen (PoE).
Anschluss von Peripherigeräten (z. B. externer Leser)
Bei dem GT7.3500 Terminal können externe Geräte angeschlossen werden. Dazu
steht eine RS-232, eine RS-485 und eine Wiegand-Schnittstelle zur Verfügung.
- RS-485: Anschluss externer, busfähiger Leser der Serie GAT SR 7xxx und
GAT SLR 7xxx.
Gruppe Klemme Signal
RS-485
VOut Versorgungsspannung für Peripheriegerät (DC 24 V)
A Datenleitung A
B Datenleitung B
GND Masse
- RS-232: Anschluss externer Geräte wie z. B. Barcodescanner
Gruppe Klemme Signal
RS-232
5V DC 5 V RS-232
GND Masse
RX Sendeleitung
TX Empfangsleitung
- Wiegand: Anschluss externer Leser mit Wiegand-Protokoll
Gruppe Klemme Signal
Wieg. DATA Daten
CLK Takt
Relaisausgänge
Relaisausgänge (1 bei GT7.2500, 2 bei GT7.3500) für die Aktivierung von
externen Komponenten wie elektronischen Türöffnern. Funktion und Zeitverhalten
der Relais sind konfigurierbar. Freilaufdiode verwenden (falls notwendig, siehe
Abbildung Seite 5) und maximal zulässige Schaltspannungen und Ströme
beachten (siehe technische Daten). Angeschlossene Elemente müssen die
betreffenden Sicherheitsstandards erfüllen (IEC 60950-1 oder IEC 62368-1).
Der Versorgungsausgang Vout 1 (24 V Gleichspannung) kann für die Versorgung
der externen Komponenten verwendet werden, sofern die Leistungsdaten
eingehalten werden (siehe technische Daten Seite 2).
Gruppe Klemme Signal
Rel. 1/2 NO Schließerkontakt
C Common
VOut 1/2
24V Spannungsversorgung für ext. Komponenten (DC 24 V, max. 300 mA)
GND Masse für Spannungsversorgung
Optokopplereingang
Ein potentialfreier Eingang zur Statuserfassung. Funktion und Zeitverhalten
des Optokopplers sind konfigurierbar. Zur Aktivierung eines Eingangs muss
Spannung angelegt werden. Die Spannung kann von der GT7 Versorgung abge-
nommen werden oder von einer externen Quelle stammen. Beachten Sie die
max. zulässigen Eingangsspannungen und -ströme (siehe technische Daten).
Angeschlossene Elemente müssen die betreffenden Sicherheitsstandards erfüllen
(IEC 60950-1 oder IEC 62368-1).
Gruppe Klemme Signal
Opto IN+ Statuseingang +
IN
-
Statuseingang -
Electrical Connections
Recommended cabling / cable lengths for Ethernet
• Shielded and twisted data cable (min. CAT. 5 recommended).
• Supply voltage via 2 wire pairs.
• Cable length max. 100 m.
Power supply
For the GT7 terminal, voltage can be supplied by a separate power supply (LPS
and SELV - Limited Power Source and Safety Extra-Low Voltage) or alternatively
it is possible to supply the device via Ethernet (PoE) instead of using a separate
power supply.
Connection of peripheral devices (e.g., external reader)
Peripheral devices can be connected to the GT7.3500 terminal. An RS-232, RS-
485, and a Wiegand interface are available for this purpose.
- RS-485: Connection of external, bus-compatible readers of the series GAT SR
7xxx and GAT SLR 7xxx.
Group Terminal Signal
RS-485
VOut Supply voltage for peripheral device (DC 24 V)
A Data line A
B Data line B
GND Ground
- RS-232: Connection of external devices, e.g., barcode scanner
Group Terminal Signal
RS-232
5V DC 5 V RS-232
GND Ground
RX Send signal
TX Receive signal
- Wiegand: Connection of external readers with Wiegand protocol
Group Terminal Signal
Wieg. DATA Data
CLK Clock
Relay outputs
Relay outputs (1 on GT7.2500, 2 on GT7.3500) for activation of external
components such as electronic door openers. The function and timing of the
relays are configurable. Use a freewheeling diode (see figure on page 5 if
required) and observe the maximum permissible switching voltages and currents
(see technical data). Connected components must comply with the relevant safety
standards (IEC 60950-1 or IEC 62368-1). Supply output Vout 1 (24 V DC) can
be used to supply the external components provided that the performance data is
maintained (see Technical Data on page 2).
Group Terminal Signal
Rel. 1/2 NO Normally open contact
C Common
VOut 1/2
24V Power supply for external components (DC 24 V, max. 300 mA)
GND Ground for power supply
Optocoupler input
One potential-free input provided for status acquisition. The function and timing
of the optocoupler are configurable. Voltage must be applied to activate the
input, which can be taken from the GT7 supply or supplied by an external source.
Observe the maximum permissible input voltages and currents (see technical
data). Connected components must comply with the relevant safety standards
(IEC 60950-1 or IEC 62368-1).
Group Terminal Signal
Opto IN+ Status input +
IN
-
Status input -

Zulassungen Compliances
Dieses Produkt ist in Übereinstimmung mit den folgenden EU-Richtlinien,
einschließlich aller zutreffenden Ergänzungen:
- 2014/53/EU (Funkanlagen RED)
Dieses Produkt ist in Übereinstimmung mit den folgenden EU-Richtlinien,
einschließlich aller zutreffenden Ergänzungen:
- 2011/65/EU (RoHS)
Das WEEE-Symbol auf einem GANTNER Produkt oder dessen Verpackung weist
darauf hin, dass das Produkt nicht mit dem normalen Hausmüll entsorgt werden
darf. Sie müssen das so gekennzeichnete Altgerät an entsprechende Sammelstellen
zum Recycling elektrischer und elektronischer Geräte übergeben. Das Recycling von
Materialien hilft bei der Schonung natürlicher Ressourcen und gewährleistet eine für
die menschliche Gesundheit und Umwelt sichere Art der Wiederverwertung. Weitere
Informationen zum Recycling eines mit dem WEEE-Symbol gekennzeichneten
Geräts erhalten Sie bei Ihrer Stadtverwaltung oder Ihrem Entsorgungsbetrieb.
RoHS
COMPLIANT
RoHS
COMPLIANT
This product is in conformity with the following EU directives, including all
applicable amendments:
- 2014/53/EU (Radio Equipment Directive)
This product is in conformity with the following EU directives, including all
applicable amendments:
- 2011/65/EU (RoHS)
The WEEE symbol on GANTNER products and their packaging indicates that the
corresponding material must not be disposed of with normal household waste.
Instead, such marked waste equipment must be disposed of by a designated
electronic waste recycling facility. Separating and recycling this waste equipment
at the time of disposal will help to conserve natural resources and ensure that it
is recycled in a manner that protects human health and the environment. For more
information on recycling an item marked with the WEEE symbol, please contact your
local city office or your household waste disposal operation.
RoHS
COMPLIANT
DE
EN
DE EN weiß
DE EN
DE
EN
DE EN weiß
DE EN
VB_GT7-2500-3500--DE+EN_11 • Art.Nr.: 1100341
Gültig ab 9. August 2018
Technische Änderungen vorbehalten!
Seite 7
VB_GT7-2500-3500--DE+EN_11 • Part No.: 1100341
Valid as of 9th August, 2018
Technical data subject to modification without notice!
Page 7
GANTNER Electronic GmbH
Montafonerstr. 8 • 6780 Schruns/Austria
Konfiguration
Die GT7 Terminals werden mit vorinstallierter Basis Access App ausgeliefert.
Nach der Montage und dem elektrischen Anschluss kann jedes Terminal mit
dieser App betrieben oder, falls gewünscht, eine andere App geladen werden, um
die gewünschte Funktion zu aktivieren. Weiters kann jede App entsprechend der
gewünschten Anwendung konfiguriert werden.
Der App Download und Konfiguration erfolgt in der G7 Connect oder über das in
den GT7 Terminals integrierte Webinterface.
1. Öffnen Sie einen Webbrowser auf einem PC oder mobilen Gerät und rufen
Sie folgende Adresse auf:
https://gantner.cloud
2. Loggen Sie sich mit ihrem Benutzernamen und Passwort in G7 Connect ein.
3. Sie sehen Ihre Terminals, die ihr Vertriebspartner oder GANTNER für Sie
angelegt hat. Alternativ können Sie auch Terminals eigenständig hinzufügen.
4. Wählen Sie hier für Ihre Terminals die gewünschten Apps aus und bearbeiten
Sie deren Konfiguration.
5. Bei Abschluss der Konfiguration werden Apps und Konfigurationen
automatisch in Ihre GT7.2500 und GT7.3500 Terminals geladen. Die
Terminals müssen dafür online und gestartet sein (Spannungsversorgung
angeschlossen).
Nähere Informationen zur Konfiguration und über die Apps finden Sie im
Handbuch des GT7.2500 and GT7.3500.
Configuration
The GT7 terminals are delivered with the preinstalled Basic Access App. After
installing a terminal and completing the electrical connections, the terminal
can be operated with the Basic Access App or another app can be loaded into
the terminal to implement the desired function. Furthermore, each app can be
configured according to the desired application.
The download and configuration of apps takes place in the G7 Connect or via the
web interface integrated in the GT7 terminals.
1. Open a web browser on a computer or mobile device and enter the following
address:
https://gantner.cloud
2. Log in to G7 Connect with your username and password.
3. All your terminals that your sales partner or GANTNER has created for you
are displayed. You can also add terminals manually.
4. Select the desired apps for your terminals and edit their configuration
settings.
5. When the configuration is complete, the configured apps are automatically
loaded into your GT7.2500 und GT7.3500 terminals. The terminals must be
online and started (power supply connected).
For more information regarding apps and the configuration process, refer to the
user manual uf the GT7.2500 and GT7.3500 terminals.
Installations- und Bedienungsanleitung
Weitere Informationen zum GT7.2500 und GT7.3500 wie z. B. Datenblätter oder die
CE-Konformitätserklärung finden Sie auf der GANTNER Internetseite unter folgendem
Link:
https://www.gantner.com/de/downloads-gt7-x500_1k3rfp49s2
Installation and Operating Instructions
Further information about the GT7.2500 and GT7.3500 like, for example, the data
sheet and CE declaration of conformity is available on the GANTNER website
via the following link:
https://www.gantner.com/en/downloads-gt7-x500_1k3rfp49s2
This manual suits for next models
1
Table of contents
Other Gantner Other manuals
Popular Other manuals by other brands

Torklift
Torklift A7200 Important owner-operator installation instructions

Siemens
Siemens 549-506 installation instructions

ThermoWorks
ThermoWorks ThermaData quick start guide

SMA
SMA SUNNY WEBBOX with Bluetooth Quick reference guide for commissioning

HQ
HQ CorTemp HT130003 user manual

Oase
Oase AquaOxy 4800 CWS operating instructions