GasLab RAD-0302 User manual

Table of Contents
Product Overview ............................................... 3
LCD Display Symbol Description ...................... 3
Operation / Calibration ..................................... 4
Safety Instructions ............................................... 6
Product Care ....................................................... 6
Specifications...................................................... 6
Weight & Dimensions .......................................... 7
Installation Instructions ....................................... 7
Troubleshooting .................................................. 7
Warranty & Support ............................................. 7

Product Overview
Thank you for selecting the RAD-0302 IAQ Mini CO2 Monitor. This is a low cost, compact, and easy-to-use indoor air quality
monitor with the ability to measure Carbon Dioxide (CO2), Temperature, and Relative Humidity concentrations in indoor air
environments. This can be used to monitor indoor air quality in the home, in the bedroom, offices, classrooms, fitness areas
or anywhere where personal comfort and overall well-being is vital.
Features
Dual
Beam
NDIR
technology
is
used
to
measure,
monitor
and
track
CO
2
concentrations
to
improve
long
term
stability.
The
Large
LCD
clearly
displays
the
CO
2
concentration,
temperature,
relative
humidity
and
real-time
clock.
3-color
back
light
(green
/
yellow
/
red)
gradually
changes
color
with
CO
2
concentration.
“HISTORY”
with
3
emotions
indicates
the
status
of
CO
2
records
up
to
24
hours.
“ECO”
saving
power
function
darkens
the
LCD
back
light
during
the
period
from
10:00pm
to
6:00am.
7-color
back
light
for
options:
white
turquoise
blue
purple
red
yellow
green.
Warning:
This
CO
2
m
onitor
i
s
not
s
uitable
for
s
afety
appl
ications. The RAD-0102-6 or similar devices is required for CO2 safety.
Remove from power when storing for long periods of time
.
1.
LCD
Display
2.
Mode Key
3.
Select Key
4.
Power Inlet (Micro USB Socket)
5.
Screw Position 8. Ventilation
Slots
6.
Calibration
Gas
Entry
7.
Humidity Sensor
Key description:
Select backlight display mode or press and hold setting modes. (+) to cycle.
Adjust the parameters.
LCD Display Symbol Description
Symbol
Meaning
Description
CO2 concentration, parts per million (ppm)
ambient CO2 concentration
Ambient temperature Ambient temperature
Relative humidity Relative humidity
Real-time setting display Real-time 24-hour clock (hour/minute)
Three emoticons The status of recorded CO2 concentration
<800ppm
800ppm~1,400ppm
>1400ppm
HISTORY: 24-hour Historical Chart
Bar graph displays indicate the status of CO2 records up to 24
hours
LCD backlight color A total of 7 colors are optional.
CO2 concentration alarm CO2 concentration alarm settings
Energy-saving The LCD backlight will be dark during the specific period.

Background calibration
Calibrate the sensor while the reading deviates from the actual gas
concentration.
Change
calibration
and
ABC
setting
parameter.
Automatic background calibration
Operation Instructions
1.
Power on and Measure:
Connect the USB cable to a PC or a USB to wall adapter to power on the device. After powered on, the bars on the LCD will decrease by
degrees
during warm-up. The device will start to measure CO2 concentration, ambient temperature and relative humidity after warm-up.
2.
Backlight Display Mode:
"
Auto
"
auto
backlight
is
the
default
mode.
Press
Mode
key
(
○
2
)
to
display
the
current
back-light
mode
and
then
press
Mode
key
(
○
2
)
to
select
setting modes in sequence: Auto AL on OFF. After selecting the mode, it is the confirmation mode. You do not need to press any
key to confirm it.
2.1
Auto: The backlight color varies with the CO2 concentration. <800ppm is green, good status; 950ppm~1,400ppm is yellow, okay
status,
>1400ppm is red, poor status – requires ventilation.
2.2
AL: The alarm level is exceeded and the backlight is displayed in red. The default alarm level is 1,400ppm. Please follow the alarm level
setting method to adjust the alarm level.
2.3
on: The LCD backlight is always on. It is only LCD backlight, without any prompt function. The backlight color depends on the color you
select. (please see the setting of COL).
2.4
OFF: Turn off all backlight functions.
3.
Setting:
Press and hold Mode key (○2 ) to enter the settings. And then press Mode key (○2 ) to select setting modes in sequence: COL (LCD backlight
color)
AL (alarm level setting) Real-time ECO (energy-saving mode). Press Select key (○3 ) to adjust the parameters.
3.1
COL: The default LCD backlight color is white. A total of 7 colors are optional. The color order is white turquoise blue purple red
yellow green. (Figure 1)
3.2
AL: The default alarm setting is 1,400ppm. The alarm value can be adjusted from 400ppm to 3,000ppm (the interval is 100ppm). (Figure 2)
3.3
Real-time:
3.3.1
Set “12 Hour (AM/PM)/24 Hour” by pressing Select key (○3 ).
3.3.2
The default real-time setting is 0:00(24 Hour Clock). The setting sequence is hour minute. After setting "hour", press Mode key
(○2 ) to
set
"minute"
(the
interval
is
1
hour
/
1
minute)
(Figure
3).
Press
Select
key
(
○
3
)
to
adjust
the
parameters.
Press
and
hold
Select
key
(
○
3
)
to quickly set the parameters.
3.4
ECO
:
The
default
ECO
setting
is
“OFF’.
Press
Select
key
(
○
3
)
to
select
“
on
’.
After
ECO
mode
is
turned
on,
the
LCD
backlight
will
be
dark
during the period from 22:00 pm to 6:00am for saving power. (Figure 4)
(Figure 1) (Figure 2) (Figure 3)
(Figure
4)
Note: During the setting process, the device will return to the main screen after 20 sec of
idle time.
4.
°C/°F switch: Press and hold Select key (+) to switch °C/°F.
4

5.
Calibration:
1.
Plug in and power your device outside.
***Note: Do not breathe directly on your device during the calibration process.
***Note: Do not place the device in direct sunlight.
2.
Allow your device to sit outside for 3 - 5 minutes to allow CO2 levels to adjust appropriately.
3.
Press and hold the Mode key (
MODE
) and then press Select key (
+
) together. When the CO2 calibration value flashes on the LCD, it
means
that the calibration mode has been entered.
Press Select Key (+) to adjust the CO2 calibration range 350ppm ~ 600 ppm, the interval is 10ppm. Set the calibration value to 400ppm.
4.
Press the Mode Key (MODE) to confirm the value, then "CAL" icon will begin to blink on the LCD.
5.
Press the Mode Key (MODE) to begin calibration. "CAL" will stop blinking. "St" will show up in the lower left section of the display
and the 10-minute countdown will begin.
6.
Once the calibration is complete, the display will show a "dn" in the place of the "St". This will indicate that the calibration is complete.
***Note: The device will return to the main screen after 20 sec of idle time.
5

6. HISTORY:
Bar graph displays indicate the status of CO2 records up to 24 hours (Figure 13)
(Figure 13)
6.
1
"0h"
bar
graph
displays
the
current
CO
2
concentration
and
it
is updated
every
10
seconds.
6.2 "-3~-24" bar graphs display the average CO2 concentration and it is updated every 10 minutes.
"-3" is the average CO2 concentration of the latest 3 hours.
"-6” In past 6 hours, the average CO2 concentration of the first 3-hours.
"-12" In past 12 hours, the average CO2 concentration of the first 6-hours.
"-18" In past 18 hours, the average CO2 concentration of the first 6-hour.
"-24" In past 24 hours, the average CO2 concentration of the first 6-hour.
E.g. It is now 12:00 noon on 12/01. “-3” = 09:00~12:00 (12/01); “-6” = 06:00~09:00 (12/01); “-12” =
00:00~06:00 (12 /01) ; “-18” = 18:00 ~24:00 (11/30) ; “-24” = 12:00~18:00 (11/30)
Safety Instructions
Warning: Your safety is very important to us. To ensure to use the device correctly and safely, we would like to draw your attention to
read the warning and entire User Manual before using the device. These are important safety information and should always be
observed.
1.
Please handle the device lightly, do not subject the device to impact or shock.
2.
Do not immerse the device in water. Water can cause electric shock, fire or malfunction which may result in damage.
3.
Do not keep the device under a hot or moist environment. Keep the device away from the heat source or near water.
4.
Please use a standard USB power supply (such as PC's USB port, universal AC adapter with USB port). Improper power supply
can cause serious damage to the device or result in injury or death to the user.
Product Care
To ensure you receive the maximum benefit from using this device, please observe the follow guidelines.
1.
Cleaning---Disconnect the power before clean. Use a damp cloth, do not use the liquid cleaning agent, such as benzene, thinner or aerosols.
2.
Repair---Do not attempt to repair the device or modify the circuitry by yourself. Please contact with the local dealer or a qualified
repairman if the device needs servicing.
3.
Air circulation---The vents allow the air circulation liquid for measurement of the CO2 concentration and the ventilation should not be blocked.
CO2 & Temperature Specifications
Method – Dual Beam NDIR (Non-Dispersive-Infrared)
LCD Display – the current CO2 concentration, temperature, relative humidity, real-time and history of CO2 records.
Sample Method – Diffusion
CO2 Specification:
Measurement Range 0-9,999ppm
Accuracy 0~3,000ppm: ±100ppm or ±7% of reading, whichever is greater; over 3000ppm: ±10%
Display Resolution 1ppm
Warm-Up Time 10 sec
Response Time About 1min
Temperature Range 0°C~50°C (32°F~122°F)
Temperature Accuracy ±1°C (±2°F)
Temperature Display Resolution
0.1°C (0.1°F)
%RH Measurement Range 0%~99% RH
%RH Accuracy ±
3%@25°C
(20%
RH~80%
RH),
other
±5%
%RH
Display
Resolution
1%RH
Operating Conditions:
Operating Temperature 0°C~50°C (32°F~122°F)
Humidity Range 0~95% RH non-condensing 0%~99%
Storage Temperature -20°C~60°C (-4°F~140°F)
6

Power Supply Requirements:
Power Supply
USB
or
5
VDC
from
external
AC/DC
adapter
which
is
not
included
in
package
(Please
use
a
standard
USB power supply)
DC Output Voltage 5VDC / ≥300mA
EMC/RFI
Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per meter, but
the performance of the instrument will not be permanently affected.
Note: Under the electromagnetic field of 3V/m, the reading will not meet the specification.
Weight & Dimensions
Weight: 86g
Dimensions: 4.13 x 2.18 x 1.28
Installation Instructions
1.
You can put the RAD-0302 CO2Mini IAQ Monitor on the table or hang it on the wall.
2.
Please note the following when hanging it on the wall: Choose a suitable location to install the RAD-0302, fix the screws to the wall. See the
Dimensions section to check the distance between the screws.
Fault Codes & Troubleshooting Guide
This section includes a list of Frequently Asked Questions for problems you may encounter with the RAD-0302 CO2Mini IAQ monitor.
Fault Icon
Description
of
The
Fault
Suggested
Actions
This
device
of
CO
2
measurement
abnormality.
The
display
is fixed at 9999 and cannot be recovered, the calibration
data has been destroyed.
The device needs to be returned to the factory for repair.
Package Contents
-
Mini 3 IN 1 CO2 Monitor
-
Manual
-
USB cable
Support & Warranty
Contact Us: We are here to help!
For more information, please contact us using the information below.
Support@GasLab.com
(386) 256-4910 (M-F) 9:00am – 5:00pm
www.GasLab.com
See GasLab, Inc. Terms & Conditions: www.GasLab.com/pages/terms-conditions
Ref.No.: 112019
Table of contents
Popular Security Sensor manuals by other brands

Niko
Niko 351-25458 quick start guide

New Cosmos Electric
New Cosmos Electric PS-7 Operation manual

B.E.G.
B.E.G. LUXOMAT PD4-M-DIM-Corridor Installation and operating instruction

ClareOne
ClareOne CLR-C1-GB-10 installation manual

B.E.G.
B.E.G. Luxomat PICO-M-1C-FC Installation and operating instruction

DPM
DPM V31 manual