REMOTE CONTROL CANCELLATION
There are 2 cancellation procedures:
=> clears the entire Eeprom memory: all data will be lost.
=> only selected remote controls will be deleted.
Total cancellation
Partial cancellation
NB: If the Eeprom memory is full, the LED on the AC120 module will blink on
entering learn mode to indicate that no other device can be learned.
- Press the “LEARN” button (Fig.5) and keep it pressed until the LED turns
OFF (at least 10-15 sec.).
: Do not release the button before the LED turns OFF otherwise
will be invalidated.
NB the
procedure
If the module has 2 Eeproms, both will be cleared. To clear only one,
disconnect the module and remove the Eeprom that must not be erased.
If the Eeprom to be cleared is fitted on socket 2, move it to socket 1 and
proceed with cancellation:
TOTAL CANCELLATION
New Remote Control:
- Check dip-switches, the new remote control will be learned
according to settings.
- Press and release the “LEARN” button on AC120 module (Fig.5)
=> the LED will blink once.
- Press one of the buttons on the remote control to be learned => the
LED will blink again.
REMOTE CONTROL CONFIGURATION
MODE 1:
MODE 2: Previously Learned Remote Control:
-Check dip-switches , the new remote control will be learned
according to settings.
- Simultaneously press buttons 1-2 or 3-4 of a previously learned
remote control and hold for 1 to 2 sec. => the LED will initially flash
quickly and then give a long flash and turn OFF.
- Press one of the buttons on the remote to learn => the LED will blink.
a) Power the module and simultaneously press and hold the “LEARN” button
for 2 sec. The LED will blink once if there is 1Eeprom or twice if there are 2
Eeproms.
b) Release the LEARN button. The LED will give 5 long flashes.
c) Repeatedly press the “LEARN” button (1 to 12 times) to select the
required group. The LED will blink the number of times corresponding to
the selected group.
if the button is pressed once too many, procedure will be repeated from
point .
d) Press the “LEARN” button (1 to 10 times) to select the remote control to be
deleted. The LED will blink the number of times corresponding to the
deleted remote control.
e) Press the “LEARN” button. The LED will turn ON.
f) Hold the ”LEARN” button until the LED turns OFF. If the button is released
before the LED turns OFF, the remote control will not be deleted and the
procedure will start again from point .
When the selected remotes have been deleted, disconnect and reconnect the
module to restore normal operating mode.
NB:
b)
b)
LEDLED
OUT 2
“LEARN”
BUTTON
LED
OUT 1
12
-
24 V
ac/dc
--
ANT
+
12 3 45678910
NB: relay contact range
10A@12-24V
WIRING DIAGRAM
Fig. 5
INPUT / OUTPUT
Antenna positive pole
Antenna negative pole (gnd)
NA (normally opened) contact - relay channel 2
NC (normally closed) contact - relay channel 2
Common - relay channel 2
Common - relay channel 1
POS.
1
2
3
4
5
6
7
8
9
10
NC (normally closed) - relay channel 1
NA (normally opened) contact - relay channel 1
Module AC120 p ( 12-30 Vac/dc )ower supply
Module AC120 power supply ( 12-30 Vac/dc )
ANT
gnd
Page 3 Page 4
NB: When learning remote controls, we recommend you write down the
device position in order to select it when it needs to be deleted.
Remote controls are divided into groups. Identify the group and the remote
control to be deleted:
- Group 1 => 1 to 10
- Group 2 => 11 to 20
- Group 3 => 21 to 30 => up to group 12 (remote control n. 120).
PARTIAL CANCELLATION