manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. General Components
  6. •
  7. Timer
  8. •
  9. General Components GC0653 User manual

General Components GC0653 User manual

Menu Options
Time & Value
Day of Week
Scheduled Programs
1. LCD DISPLAY LAYOUT
2. SETTING TIME AND DAY OF WEEK
3. MANUAL VENTIALTION MODE
4. MANUAL HEAT MODE
5. SWITCHING BETWEEN SETPOINT
AND VARIABLE HEAT MODES
6. HIGH ELEVATION MODE
When heater is used at elevations between
1500m and 4000m above sea level, heater
should be operated in High Elevation Mode to
make sure enough oxygen is provided for
efficient combustion of fuel.
To toggle High Elevation Mode, press [<]
and Ok buttons simultaneously while in heating
mode. This works in both Setpoint and Variable
Heat modes.
It is not recommended using the heater at
more than 4000m above sea level.
Using [<] and [>] keys, navigate
to Clock Icon and press Ok.
Days of Week segment lights up.
Select current day using
[<] and [>] keys and press Ok.
Hours segment begins to flash.
Set hour (military time, 0-23) using
[<] and [>] keys and press Ok.
Minutes segment begins to flash.
Set minutes using
[<] and [>] keys and press Ok.
Day of week and time
are now set.
Timer LCD is comprised
of several distinct
segments, such as
Menu Options, Day of
Week, Scheduled
Programs and Time &
Value field.
Using [<] and [>] keys, navigate to
Fan Icon and press Ok.
Ventilation Mode started.
Select fan intensity between 01
and 07 using [<] and [>] keys
Press Power Button to exit
ventilation mode.
Fan will ramp down and stop.
Using [<] and [>] keys, navigate to
Heat Icon and press Ok.
Heating Mode started.
Select heat intensity between 01
and 07 using [<] and [>] keys
Please note, it takes approx. 2-3
minutes for the heater to start
heating or to come to a full stop.
Press Power Button to exit
manual heating mode.
Heater will cool down and stop.
While in heat mode, press and
hold Ok button for 3 seconds to
toggle between Variable Heat
and Setpoint (thermostatic)
modes.
In Setpoint Mode, heater will
maintain preset ambient
temperature (between 5°C and
35°C) based on the reading of
internal or external temperature
sensors.
In Variable Heat Mode, heater
will continuously produce heat
based on the setting 01 –07,
which translates into 0.5Kw –full
capacity (2, 4 or 5Kw, depending
on model).
QUICK START
GUIDE
GC0653
DIGITAL TIMER
FOR AIR HEATERS
7. SETTING SCHEDULED OPERATION
8. FUEL LINE PRIMING
This function enables fuel pump for a
short period of time to help get rid of air inside the
fuel lines after initial installation or if the fuel tank
ran out of fuel.
It is recommended to disconnect the fuel
line from the heater before using this function to
avoid flooding of the heater.
Refrain from using this function and refer
to the nearest dealer or experienced mechanic for
help if you don’t feel confident doing this.
Depending on length of your fuel line, you
may need to run priming cycle several times to
fully prime the line.
9. READING AND CLEARING ERRORS
10. FACTORY RESET
Following steps reset timer settings only. This
operation does not affect heater’s ECU.
Using [<] and [>] keys, navigate
to Program Icon and press Ok.
Program Number segment lights up.
Select program number using
[<] and [>] keys and press Ok.
Program Status screen comes up.
Select On to enable or Off to disable
the program and press Ok.
Program Duration screen comes up.
Select cycle duration between 50
and 800 minutes and press Ok.
Program Start screen comes up.
Select start time hour (military, 0-23
hours) and press Ok.
Select start time minutes and
press Ok.
Day of Week screen comes up.
Scroll through every day of the week
and select On or Off as needed.
The program is now set.
To set programs 2 and 3 repeat
the process, changing the
program number in step 3.
Using [<] and [>] keys, navigate
to Clock Icon and press
[<] and [>] keys simultaneously.
Using [<] and [>] keys, navigate
to Clock Icon.
Digital timer allows you to read
and clear six most recent faults
stored in heater’s ECU.
To display Error Screen while in
heat mode, press [<] and [>]
keys simultaneously.
Use [<] and [>] keys to scroll
through error codes 1E –6E.
To clear all errors, press
[<] and [>] simultaneously.
To go back to previous screen,
press Power or Ok button.
If the fault keeps coming up
after you reset it, please refer to
the nearest dealer to rectify the
cause of the problem.
P1 should appear on the screen.
Using [<] or [>] key, change P1
to P2 and press Ok.
Fuel pump starts pumping.
Pump will prime at frequency of
2.5Hz and stop after 90 seconds.
During this period, fuel pump
should deliver 15.5 ml of fuel.
Use any key to stop the pump
and exit Priming Mode.
Press [<] and [>] keys
simultaneously.
Using [<] or [>] key, select 01
and press Ok.
Timer is now reset to factory
settings.
11. °C/°F AND LANGUAGE
Using [<] and [>] keys, navigate
to Clock Icon and press
[<] and [>] keys simultaneously.
press Ok.
press Ok.
Select “on”for option “00”.
Option “01”switches between
Celsius (“on”) and Fahrenheit
(“of”)
Option “02”switches language:
“on”–English, “of”–Chinese.
If the fault keeps coming up
after you reset it, please refer to
the nearest dealer to rectify the
cause of the problem.

Popular Timer manuals by other brands

Woods 59018 instruction manual

Woods

Woods 59018 instruction manual

Auber Instruments JSL-74 instruction manual

Auber Instruments

Auber Instruments JSL-74 instruction manual

Grasslin tasu 472 1 plus instruction manual

Grasslin

Grasslin tasu 472 1 plus instruction manual

Leifheit 21351 operating instructions

Leifheit

Leifheit 21351 operating instructions

Intermatic Grasslin GM40 Series operating instructions

Intermatic

Intermatic Grasslin GM40 Series operating instructions

Plikc ASTRO WIFI instruction manual

Plikc

Plikc ASTRO WIFI instruction manual

Orbit 24713 user guide

Orbit

Orbit 24713 user guide

BAREBO 962270 user manual

BAREBO

BAREBO 962270 user manual

Tork DZS200 Installation & operation

Tork

Tork DZS200 Installation & operation

MULTISPAN DIN-63C operating manual

MULTISPAN

MULTISPAN DIN-63C operating manual

ELMARK VBRTV492 Operational guide

ELMARK

ELMARK VBRTV492 Operational guide

Elgo 1180 Operation instructions

Elgo

Elgo 1180 Operation instructions

Intermatic PB300E Series Installation, operation & service manual

Intermatic

Intermatic PB300E Series Installation, operation & service manual

Emos 15FD/3A manual

Emos

Emos 15FD/3A manual

Leviton ACT60 installation instructions

Leviton

Leviton ACT60 installation instructions

Robic M903 instructions

Robic

Robic M903 instructions

Wise Round - S1 quick start guide

Wise

Wise Round - S1 quick start guide

Hydrofarm TM01715D manual

Hydrofarm

Hydrofarm TM01715D manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.