Leviton ACT60 User manual

Electronic Timer
(10, 20, 30, 60 minutes)
Cat No. ACT6
Ø
(Lighted)
1000W Incandescent – 20A-120VAC, 60Hz Inductive
1 hp-120VAC, 60Hz-UL – 3/4 hp-120VAC, 60Hz-CSA
INSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
Step 1 WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN
OFF POWER at circuit breaker or fuse and test that power is
off before wiring!
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&/./&&
/./&&
/./&&
/./&&
/./&&
2
4
3
1Single Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
DI-000-ACT60-00A-X0
INSTALLING YOUR TIMER
NOTE: Use check boxes when Steps are completed.
Identifying your wiring application (most common):
NOTE: If wiring in the wall box does not resemble this
configuration, consult a qualified electrician.
Preparing and connecting wires:
Strip Gage
(measure bare wire here)
5/8"
(1.6 cm)
Cut
(if necessary)
For non-standard wiring applications, refer
to Wire Nut and Conductor Size Chart
1 - #12 w/ 1 to 3 #14, #16 or #18
2 - #12 w/ 1 or 2 #16 or #18
1 - #14 w/ 1 to 4 #16 or #18
2 - #14 w/ 1 to 3 #16 or #18
WIRE NUT / # OF COND.
COMBINATION CHART
• Pull off pre-cut insulation from timer leads.
• Make sure the ends of the wires from the wall box are
straight (cut if necessary).
• Remove 5/8" (1.6 cm) of insulation from each wire in the
wall box as shown.
Important Notice for Installer
To achieve proper aesthetic installation of the Acenti products,
the wall surface surrounding the wall box opening must be fairly
flat and free of irregularities. The wall box must be level and
recessed or flush to the wall surface. The Acenti installation
system allows for adjustments that will correct minor flaws that
may be present in the installation area.
This device must be installed with the AcentiTM Alignment Plate.
The Alignment Plate is packaged with the AcentiTM Wallplate,
which is sold separately from this device.
The Alignment Plate will function properly only if it is mounted to
a flat wall surface as described above.
• Leviton recommends to temporarily position the Alignment
Plate prior to wiring the device. If the wall box wires extend at
least 6 inches out of the wall box, it is also possible to install
the Alignment Plate after the device has been wired (refer to
Wallplate instruction sheet).
• The Alignment Plate must be installed with the tab towards
the bottom.
• Leviton recommends the following methods to temporarily
hold the Alignment Plate – use of device mounting screw,
use of wall box wires, or use of electrical tape (refer to the
following figures):
Installing your Alignment Plate:
Alignment Plate Held
By Mounting Screw
TOP
A
Mounting
Screw
Alignment
Plate
C
TOP
Alignment Plate Held
By Tape
Electrical
Tape
B
TOP
Step 2
Step 3
Step 4 Step 4 cont’d
Alignment Plate Held
By Wires
Slotted/Phillips Screwdriver Electrical Tape
Pliers Pencil
Cutters Ruler
Tools needed to install your Timer:
MULTI-DEVICE APPLICATION:
NOTE: You only need to remove side sections if installing with other
timers/dimmers or if it does not fit in wall box – not when installing with
mechanical switches.
If installing Timer in a single device application, proceed with the
INSTALLING YOUR TIMER section. If installing Timer in a multi-device
application, proceed as follows:
Installing Timer by itself or with other devices:
Remove
all inner
side
sections
Do not
remove
outer
side
sections
Bend back and
forth to remove
side section

DI-000-ACT60-00A-X0
60 min.
30 min.
20 min.
10 min.
Locator Light
LED Indicator Timer Button
Wallplate Mounting:
Mounting: with notch facing down, press on AcentiTM wallplate
(sold separately).
Removal (if necessary): Using a small screwdriver, place in
notch in bottom of wallplate and gently lift up to remove.
To start the timer: Press the desired
timer button. The Blue LED indicator next
to the selected key turns ON. After the
selected period of time, the load shuts
OFF automatically. When the count down
reaches the time shown on the next key,
the LED next to that key turns ON, and
the first LED turns OFF.
To select another time when the
timer is already ON: Press the
desired timer button. The countdown
restarts with the new time selected.
• Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly with wire connectors.
• Light does not turn ON and Locator LED does not turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp Neutral connection is not wired.
For additional information, contact the AcentiTM
information hotline at 1-888-4-ACENTI or visit
Leviton’s website at www.leviton.com/acenti
U.S. & Foreign Patents Pending
Copyright©2004 Leviton Manufacturing Co., Inc.
All Rights Including Trade Dress Rights Reserved
Testing your Timer prior to completely mounting in
wall box:
NOTE: Dress wires with a bend as shown in diagram in order to relieve
stress when mounting device.
• Position all wires to provide room in outlet wall box for device.
• Ensure that the word “TOP” is facing up on both the alignment plate and
timer strap.
• Position device so that the alignment holes fit on alignment pins as
shown. Press switch onto alignment plate until strap sits flat.
Timer Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
• Re-position alignment plate for leveling.
• Tighten mounting screws into wall box so that device remains flat on
alignment plate.
CAUTION: DO NOT over-tighten device mounting screws. Over-
tightening will cause improper mounting and alignment. Using a high-
torque power screwdriver is not recommended. Alignment Plate must sit
flush on wall surface.
TOP
• Position adapter plate onto timer so that the
star pattern alignment holes also fit on the
alignment pins as shown. Press adapter plate
onto timer until strap sits flat.
• Partially screw in mounting screws in wall box
mounting holes.
TOP
Wall Surface
Alignment Pin
(2 places)
Alignment Hole
(2 places)
Mounting Screw
Adapter Plate
Installing your Timer –
Single Pole Wiring Application:
1
4
2
3
Black
Blue
Green
White
Hot (Black)
Neutral (White)
Load
Timer
Black
White
Black
White
Blue
Green
Ground
Line
120/277VAC, 60Hz
WIRING TIMER:
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green timer lead.
• Line Hot wall box wire to Black timer lead.
• Load wall box wire to Blue timer lead.
• Neutral wall box wire to White timer lead.
Step 5 Step 6
Step 7
Step 8
Restore Power: Restore power at circuit breaker or fuse.
Installation is complete.
Step 9
• Restore power at circuit breaker or fuse.
• Carefully holding device as shown,
tap any button other than OFF. Lights
should turn ON.
If lights do not turn ON, refer to the
TROUBLESHOOTING section.
Step 7 cont’d
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its
option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for
removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties
of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect,
special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
TOP
Wall Surface
Pin and alignment
hole engaged
Notch on bottom
WallPlate
OPERATION
TROUBLESHOOTING
OFF Button
Table of contents
Other Leviton Timer manuals

Leviton
Leviton Decora 6124H User manual

Leviton
Leviton Decora LTT15 User manual

Leviton
Leviton LT111 User manual

Leviton
Leviton decora User manual

Leviton
Leviton TS300 User manual

Leviton
Leviton Decora 6124H User manual

Leviton
Leviton Decora 6652 User manual

Leviton
Leviton Decora 6651 User manual

Leviton
Leviton Decora 6124H User manual

Leviton
Leviton VPT24 User manual